Records from 1994 to 2026. Most recent: inspection, 13 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 47
13 April 2026
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8346715
9 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8323432
9 February 2026
Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8308425
4 March 2025
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8085866
12 November 2024
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8033927
21 June 2024
Internal Structural Exam · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7904963
15 February 2023
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7635252
18 May 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7454188
8 July 2021
Deficiency Check · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7239935
23 April 2020
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6945290
15 May 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6685994
20 March 2019
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6646249
1 May 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6410532
16 May 2017
Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6147812
12 April 2017
Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6123176
7 November 2016
Simplified Stability Test
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6049514
28 April 2016
COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5864665
3 November 2015
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5756583
27 March 2014
Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4824426
11 March 2010
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3693915
12 September 2008
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3323570
13 August 2008
Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3297572
12 March 2008
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3163062
26 July 2007
Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3013154
29 March 2007
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2897980
10 August 2006
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2743476
23 June 2006
COI Inspection · Deadweight Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2699884
19 June 2006
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2685131
8 February 2006
Hull Examination · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2584170
21 May 2003
Hull Examination · Administrative Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1797303
19 February 2003
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1745716
28 September 2001
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1425191
24 May 2001
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1401481
20 September 2000
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1053903
17 August 2000
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 822085
17 August 2000
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1420379
1 March 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1442971
9 July 1999
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1434922
28 May 1999
COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1427627
12 August 1998
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1130818
20 June 1998
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 795857
16 June 1997
Deficiency Check · Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1443887
3 July 1996
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1371470
11 June 1996
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1407700
20 June 1995
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1443593
14 June 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1181575
9 June 1994
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 866317
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 April 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI discovered an exposed live wire in vicinity of port side gasoline fuel tank. Remove to satisfaction of USCG.
46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 April 2026
Resolved
Flammable vapor detection systems. A sensor must be located above the expected bilge water level in the following locations:(2) The lowest part of a space containing a fuel tank when separate from the machinery space. Lower port side vapor detector as indicated by attending marine inspector.
46 CFR 182.480(e)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 April 2026
Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. STBD side vapor detector is not alarming at the operating station.
46 CFR 182.480(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 April 2026
Resolved
Each survival craft must be:(1) Secured to the vessel by a painter with a float-free link permanently attached to the vessel. Painter line not connected to weak link.
46 CFR 180.130 (a)(1)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 April 2026
Resolved
(p) The servicing facility must issue a certificate to the liferaft owner or owner's agent for each liferaft it services. The certificate must include—
(1) The name of the manufacturer of the liferaft;
(2) The serial number of the liferaft;
(3) The date of servicing and repacking;
(4) A record of the fifth-year gas-inflation test required in paragraph (g) of this section, whenever that test is performed;
(5) A record of the hydrostatic test of each inflation cylinder required in paragraph (e) of this section, whenever that test is performed. Provide liferaft servicing documentation to include hydrostatic release install date. Mark hydrostatic for two years from install date.
46 CFR 160.151-57(p)(5)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 April 2026
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that:(3) The pump is permanently mounted. STBD FWD bilge pump needs to be mounted.
46 CFR 182.520 (e)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2026
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 13 April 2026
Resolved
c) A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Medical certificates must be issued and will remain current for the following periods of time, unless otherwise noted on the certificate:
(2) Five years for all other mariners. Provide documentation of a valid medical certificate.
46 CFR 15.401(C)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 March 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Emergency fuel shut off valves not fully closing.
46 CFR 182.455 (b)(4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2025
Resolution: Rectified
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 March 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following:
(2) Inspection and operation of all watertight closures in the hull, decks, and bulkheads including through hull fittings and sea valves;Side shell fitting on the stbd
side quarter needs to be replaced.
46 CFR 176.802
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2025
Resolved 6 March 2025
Resolution: Rectified, thru hull and skin valve replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Aft deck light has exposed wireing.
46 CFR 183.200 (b)
Action required: 10 - Deficiency Rectified
Resolved 4 March 2025
Resolution: Rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 November 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an ergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the
OCMI before work is started.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2025
Resolution: Cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 November 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Fire in engine room reported.
1) Make full repairs and attest to serviceability of main propulsion engines and associated components. Conduct repair verification and sea trial with Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2025
Resolution: Cleared
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 June 2024
Resolved
Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout accommodation spaces. Adult and child PFDs are stored below vessel operating station, an area that is more conducive to being a fire source. Relocate PFDs to a different area that can be easily accessible by passengers. 46CFR180.78
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2024
Resolved 23 June 2024
Resolution: PFDs re-located to below pax seats; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 June 2024
Resolved
A sensor must be located above the expected bilge water level in the following locations:(2) The lowest part of a space containing a fuel tank when separate from the machinery space. Port and stbd gasoline fuel tank space flammable vapor detectors are not located at the lowest part of the space. Reposition detectors to lower portion of space. 46CFR182.480(e)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2024
Resolution: Vapor detectors were moved to a lower position; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 June 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Three fire buckets have capacity larger than 2.5 gallons. Replace or modify bucket to meet quantity amount. 46CFR181.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2024
Resolution: Fire buckets were adjusted to meet 2.5 gallon requierment.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 June 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Operator did not have servicing report for fixed fire suppression system. Provide report to Marine Inspector.46CFR810(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2024
Resolution: Fire servicing report was provided; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2024
Resolved
Each heater must be so constructed and installed as to prevent contact with combustible materials such
as towels and clothing. Heating unit in accommodation/vessel operating station area is in close proximity to combustible materials. Remove, tag out (take off-line) or reposition heating unit away from combustible materials. 46CFR184.210(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2024
Resolution: Heating unit was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 June 2024
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. Float light lanyard does not have a corrosion resistant clip. 46CFR180.70(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2024
Resolution: Corrosion resistant clip was installed; all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 June 2024
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating
Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Operator could not provide application completed for EPIRB registration. Provide documentation for EPIRB registration. 46CFR184.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2024
Resolution: Hydro unit was re-labeled.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 21 June 2024
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. An inspection of radio installation equipment was not conducted by a licensed FCC technician. Complete inspection of equipment no latter than 28JUN2024.47CFR80.903
Action required: 705 - Other - as specified
Due 28 June 2024
Resolved 27 June 2024
Resolution: Radio equipment inspected. FCC cert issued.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 21 June 2024
Resolved
Except as provided in §§ 80.177 and 80.179, operation of
transmitters of any ship station must be performed by a
person holding a commercial radio operator license or permit of the class required below. The operator is responsible for the proper operation of the station. Vessel master did not have marine operator permit. 47CFR80.155
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 4 March 2025
Resolution: Resolved
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 June 2024
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting
with the roll and pitch of the vessel, and free from exposure to water splash or spray. Batteries are not secured with a strap to prevent movement. 46CFR183.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 27 June 2024
Resolution: Battery was secured with strap.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 21 June 2024
Resolved
Pre-employment testing requirements. (a) No marine employer shall engage or employ any individual to serve as a crew-member unless the individual passes a chemical test for dangerous drugs for that employer. Perspective employee has not completed pre-employment testing and consortium enrollment. Provide evidence of new employee meeting requirements prior to filling safety sensitive position (crew member). 46CFR16.210
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 June 2024
Resolution: Crew member was not hired, due to refusing to take pre employment drug test.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 June 2024
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Light in compass unit is inoperable. Restricted to day light operations. 46CFR184.402(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 June 2024
Resolution: Verified compass light. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 June 2024
Resolved
A hatch cover must: (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices
of substantial strength to prevent its loss. Aft port
hatch is not secured with a device to prevent its loss. 46CFR179.360(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 June 2024
Resolution: Hatches secured with lanyard.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 21 June 2024
Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available. Operator did not have stability letter on-baord. Post letter at operating station. 46CFR178.210
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 June 2024
Resolution: Stability letter added to vessel and posted. Verified by attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 June 2024
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. IBA hydrostatic release unit was marked with installation date not expirations date. Re-stencil hydrostatic release unit with appropriate expirations date and provide evidence of change to Marine Inspector. 46CFR185.740(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 June 2024
Resolution: Hydrostatic release unit stenciled with appropriate expiration date. Verified by attending inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 21 June 2024
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Operator did not have any alcohol testing swabs onbaord. 46CFR185.212
Action required: 10 - Deficiency Rectified
Resolved 21 June 2024
Resolution: Testing swabs provided; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 February 2023
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. The OCMI may also decrease the drydock examination intervals to monitor the vessel's structural condition...Hull gauging report required on all bellow the water line hull plating prior to bringing vessel back into commercial service due to large amounts of corrosion and pitting noted during a non credit ise exam on 23-24 Feb 2023 in Petersburg,AK. The two generator voids require hull plate replacement at this time due to heaving pitting and corrosion beyond 50% wastage noted during this inspection. Submit hull gauging report and repair proposal to the local OCMI prior to completing any work.46 CFR 176.600 / (Old T) 46 CFR 176.25-5.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2024
Resolution: Repairs of affected hull completed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 July 2021
Resolved
Vessel is required to have x3 Day and x3 Night, CG Approved Visual Distress Signals. Vessel does not have the correct day/night VDS pyro.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2021
Resolved 8 July 2021
Resolution: Owner purchased and had onboard the appropriate day/night flares.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 July 2021
Resolved
Vessels IBA needs to be float free arrangement, discovered vessels IBA improperly installed, was not connected to the weak link on the hydrostatic release.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2021
Resolved 8 July 2021
Resolution: Owner connected the IBA's painter to the weak link with a stainless steel shackle.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 July 2021
Resolved
Vessel is required to have an anchor light and fwd mast head light while operating at night or reduced visibility, Found the anchor/fwd mast head light not working. Vessel restricted to daytime operations until the navigation lights are repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2021
Resolved 27 July 2021
Resolution: Owner replaced the navigation light with a new one.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2021
Resolved
Vessel is required to have bonding wire at the hose connections for the port and stbd metallic fuel fill pipes to the fuel tank. Bonding wires are missing on both fuel tanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 27 July 2021
Resolution: Owner installed a bonding wire onto the fuel tanks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2021
Resolved
Fuel tank voids, power ventilation fans have internal electric motors that are installed inside the the ventilation duct and have plastic vent hose, vent fan motors shall be external to the ventilation and have metallic ventilation hose.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2021
Resolved 14 September 2021
Resolution: Owner replaced with proper type of power exhaust fans and renewed ventilation hoses
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2021
Resolved
Fuel fill hoses installed over pipe must be double clamped. The port side fuel fill hose is missing double clamps.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 27 July 2021
Resolution: Owner installed double hose clamps on hose on pipe connection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 July 2021
Resolved
Vessels life ring buoy shall be CG Approved with x4 bans of retroflective tape. Vessels life ring buoy missing x3 bans of retro tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 27 July 2021
Resolution: Owner added missing SOLAS retroflective tape onto the ring buoy.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 July 2021
Resolved
Fuel tank voids, power ventilation system must shut down when the pre engineered fire extinguishing system discharges. Prove proper operation of power ventilation shut downs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2021
Resolved 14 September 2021
Resolution: Owner installed loose wire on pre engineered fire system for blower shut down.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 July 2021
Resolved
Hatches accessible to the weather deck must be watertight, the two aft deck hatch gaskets are worn out and partially missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 27 July 2021
Resolution: Owner installed new gaskets into the weather deck hatch covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2021
Resolved
Electrical installations shall be safe, hazard free, and prevent ignition source. Remove dead end wires in the port fuel tank void.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 27 July 2021
Resolution: Owner properly terminated loose wiring.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 July 2021
Resolved
Vessels EPIRB (NOAA)registration shall be onboard while operating, vessels name shall be marked onto the EPIRB. Vessels EPIRB registration and decal where not onboard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 27 July 2021
Resolution: Owner received new EPIRB registration documents and placed them onboard the vessel.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 8 July 2021
Resolved
Vessel must post emergency radio operating procedures close to the vessel's radiotelephone (VHF). Operating procedures are not present/missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 27 July 2021
Resolution: Owner placed emergency radio operating procedure sticket at the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 April 2020
Resolved
The required life raft was not installed. Prior to carrying passengers, the required IBA must be installed IAW 46 CFR 180.130.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2021
Resolution: The owner properly installed a 30 person IBA with good thru 04/2022.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 April 2020
Resolved
The hydrostatic release on the EPIRB was expired. Prior to carrying passengers, install a new hydrostatic release on the EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2021
Resolution: The owner installed a new EPIRB Hydrostatic Release Good thru 07/2023.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 April 2020
Resolved
Prior to carrying passengers, a fire drill must be completed in the presence of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2021
Resolution: Sucessfully completed drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 April 2020
Resolved
Prior to carrying passengers, prove proper operation of the ship’s machinery, to include propulsion, steering, bilge high level alarms and pumping, and main engine shut downs associated with the fixed extinguishing system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2021
Resolution: Completed satisfactory COI/DryDock/ISE inspection.
Communications › Radio Communications › EPIRB
Issued 1 May 2018
Resolved
Vessel is restricted to operating as an uninspected passenger vessel carrying no more than 6 passengers for hire. The vessel is restricted to no more than 6 passengers for hire until a properly registered EPIRB is placed in service on the vessel. The vessel’s current EPIRB’s battery expiration date cannot be determined.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2018
Resolved 8 May 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 1 May 2018
Resolved
Vessel’s Safety Radio Certificate is expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2018
Resolved 8 May 2018
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 May 2018
Resolved
Demonstrate man-overboard and fire drills to the attending Marine Inspector
Vessel owner/operator has been conducting drills with crews and has logged all drills.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2018
Resolved 8 May 2018
Resolution: Vessel owner/operator has been conducting drills with crews and has logged all drills.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 March 2014
Resolved
DEMONSTRATE A MAN OVERBOARD AND FIRE DRILL TO SATISFACTION OF USCG MARINE INSPECTOR. GET VESSEL UNDERWAY AND DEMONSTRATE OPERATION OF VESSEL.
Action required: 705 - Other - as specified
Due 6 May 2014
Resolved 15 May 2014
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 27 March 2014
Resolved
DEMONSTRATE OPERATION OF FUEL TANK SPACE BLOWERS.
Action required: 705 - Other - as specified
Due 6 May 2014
Resolved 15 May 2014
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 March 2010
Resolved
Two pipes are penetrating the traverse bulk heads on the starboard side. Pipes are not capped and would allow the free flow of water between spaces.
Due 22 April 2010
Resolved 15 June 2011
Engineering › Bilge Water Management System › Valve
Issued 11 March 2010
Resolved
Two valves would not fully close and need to be replaced
Due 22 April 2010
Resolved 15 June 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 August 2008
Resolved
Install battery covers over terminals on both batteries.
Due 13 September 2008
Resolved 12 September 2008
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 13 August 2008
Resolved
Plug holes in battery storage compartment to prevent fuel vapor from tank space to enter space.
Due 13 September 2008
Resolved 12 September 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 August 2008
Resolved
Demonstrate proper operation of vessels fixed fire extinguishing system. This includes ventilation shutdowns and audible alarm at operating station.
Action required: 705 - Other - as specified
Due 20 August 2008
Resolved 19 September 2008
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 13 August 2008
Resolved
Demonstrate operation of vapor detector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2008
Resolved 12 September 2008
Engineering › Bilge Water Management System › Hose
Issued 13 August 2008
Resolved
Un-kink bilge discharge line in port aft fuel compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2008
Resolved 12 September 2008
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 13 August 2008
Resolved
Label all bilge switches at helm to indicate location of pump.
Due 13 September 2008
Resolved 12 September 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 July 2007
Resolved
Demonstrate proper operation of fixed fire extinguisher discharge audible alarms and ventilation shutdowns for port and starboard fuel tank compartments.
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 12 September 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 26 July 2007
Resolved
Replace plastic duct hose with non combustible ducting. Also ensure ducting is split to opposite sides of the compartment IAW 46CFR 182.460
Action required: 705 - Other - as specified
Due 26 August 2007
Resolved 13 August 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 23 June 2006
Resolved
IAW 46 CFR 182.460, Install and prove proper operation of a mechanical exhaust system in both port and starboard compartments containing fuel tanks.
Action required: 705 - Other - as specified
Due 3 August 2006
Resolved 10 August 2006
Resolution: Owner properly installed power ventilation blowers in both required compartments. Both tested sat.
Communications › Radio Communications › EPIRB
Issued 23 June 2006
Resolved
Provide proof of EPIRB registration.
Due 3 August 2006
Resolved 10 August 2006
Resolution: Proof of EPIRB registration provided.
Engineering › Fuel Oil Service System › Discharge Strainer
Issued 23 June 2006
Resolved
Install drip pans with 30 x 30 mesh flame screens under both port and starboard fuel filters, and replace the non-metallic filter plug with a metallic plug.
Action required: 705 - Other - as specified
Due 3 August 2006
Resolved 29 March 2007
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 23 June 2006
Resolved
Relocate battery exhaust to vent into the atmosphere and not into the passenger accommodations.
Action required: 705 - Other - as specified
Due 3 August 2006
Resolved 10 August 2006
Resolution: Battery compartment received proper ventilation louver to outside main deck of vessel vice the passenger compartment.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 23 June 2006
Resolved
IAW 46CFR 181.400, Install and prove proper operation of a fixed fire extinguishing system in both port and starboard compartments containing fuel tanks. Installation shall be IAW 46CFR 181.400 and to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 3 August 2006
Resolved 10 August 2006
Resolution: Installation complete of required approved fixed fire extinguishing system in both compartments containing f/o service tanks (gasoline). Installation in accordance with applicable regs as well as manufacturer instructions.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 23 June 2006
Resolved
IAW 46CFR182.410(c), Install and prove proper operation of a flammable vapor detection device in both port and starboard compartments containing fuel tanks.
Action required: 705 - Other - as specified
Due 3 August 2006
Resolved 10 August 2006
Resolution: Satisfactory installation of vapor detection system was completed in both required compartments. Monitoring system located at operating station.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 8 February 2006
Resolved
Provide an underway test of vessel and exercise new outboard engine configuration.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 3 July 2006
Documentation › Certificates/Documents
Issued 23 August 2001
Resolved
Provide proof of enrollment in a drug testing program IAW 46 CFR 16.
Due 23 September 2001
Resolved 18 September 2001
Construction/Loadline
Issued 24 May 2001
Resolved
INSTALL CHECK VALVES, OR EQUIVALENCY, IN WAY OF THE PORT AND STARBOARD ENGINE COOLING COUPLINGS AT THE TRANSOM. ENSURE THE INSTALLATION MEETS THEMANUFACTURERS RECOMMENDATIONS.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Construction/Loadline
Issued 24 May 2001
Resolved
COMPLETE AN OPERATIONAL (UNDERWAY) TEST OF THE VESSEL UPON INSTALLATION OF THE PORT ENGINE AND PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Construction/Loadline
Issued 24 May 2001
Resolved
SUBMIT AN ESTIMATE OF ALL WEIGHT REMOVED/ADDED (E.G. GENERATOR AND AIR CONDITIONING UNIT/SAND BAGS IWO THE BOW) IN PREPARATION OF A NEW SIMPLIFIEDSTABILITY TEST.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Construction/Loadline
Issued 24 May 2001
Resolved
INSTALL ZINCS IN WAY OF THE OUTDRIVES.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Lifesaving
Issued 28 May 1999
Resolved
PROVIDE 6 RED AND 6 ORANGE VALID DATED FLARES.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Lifesaving
Issued 28 May 1999
Resolved
PROVIDE 2 PADDLES FOR THE LIFEFLOAT.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Lifesaving
Issued 28 May 1999
Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILLS.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Documentation
Issued 28 May 1999
Resolved
PROVIDE A VALID SOUTH CAROLINA STATE REGISTRATION CERTIFICATE.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Documentation
Issued 28 May 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Electrical
Issued 28 May 1999
Resolved
PROPERLY PROTECT ALL ELECTRICAL WIRES UNDER THE BRIDGE CONSOLE (DEAD END).
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Lifesaving
Issued 28 May 1999
Resolved
PROVIDE AN OPERABLE STROBE LIGHT FOR THE LIFEFLOAT.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Documentation
Issued 28 May 1999
Resolved
PROVIDE DRUG TESTING PROGRAM INFORMATION.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Engineering
Issued 16 June 1997
Resolved
Provide markings on emergency fuel oil shut off pull cables for both main diesel engines.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Lifesaving
Issued 16 June 1997
Resolved
Provide emergency broadcast placard.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Lifesaving
Issued 16 June 1997
Resolved
Provide emergency instructions as required by 46 CFR 185.510.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Navigation
Issued 16 June 1997
Resolved
Make repairs to Anchor light.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Documentation
Issued 3 July 1996
Resolved
Provide complete drug testing program as required by 46 CFR part 16.
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996