Records from 1996 to 2026. Most recent: inspection, 26 May 2026.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 18.7 ft × 7.0 ft
Registered tonnagegross 52 / net 42
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · THOMPSON, NY, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCAPE VINCENT, NY
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Simplified, Net Ton
52 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
26 May 2026
Administrative Inspection · Vessel Attendance · COI Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8380839
22 January 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8290085
6 October 2025
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8239129
13 December 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8047020
16 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7866117
5 October 2022
Deficiency Check · Initial Certification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7557371
18 July 2022
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7509900
30 September 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6825241
30 September 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6828070
31 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6571739
1 September 2018
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6533887
12 June 2013
Deficiency Check · Industry Initiated Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4638510
10 February 2012
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4242028
29 December 2010
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 4095858
2 April 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3175865
22 October 2007
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3093987
17 January 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2574758
27 October 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2523616
3 March 2000
Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1046910
30 April 1998
Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1126913
25 March 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 640275
9 January 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 92681
30 December 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 70743
3 November 1996
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 116636
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 January 2026
Resolved
Replace the grab lines on all ring life buoys. Some have frayed or deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2026
Resolved 20 March 2026
Resolution: Sent pictures of def corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 January 2026
Resolved
Label the stowage compartment with 1 inch letters where the life jackets are stored.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2026
Resolved 20 March 2026
Resolution: Sent picture of labeling.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 December 2024
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet. Vessel had an incomplete first aid cabinet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2025
Resolved 13 January 2025
Resolution: completed
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 13 December 2024
Resolved
There must be installed bilge pump for emergency dewatering. The pipe connection for the portside bilge overboard is corroded and needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2025
Resolved 13 January 2025
Resolution: replaced
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 13 December 2024
Resolved
EPIRB Hydrostatic Release is expired. Replace with new hydro and mark expiry date.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2025
Resolved 13 January 2025
Resolution: Provided new
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 February 2024
Resolved
Vessel is on Lakes, Bays and Sounds route beyond 3 miles from shore is required 6 day, and 6 night flares. Flares on board were expired. Provide 12 flares (6 hand red, and 6 smoke, or 12 hand red).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2024
Resolution: Vessel provided new flares on board
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 February 2024
Resolved
Fire Detection Panel was in "trouble" mode. After re-set, did not go away. Provide evidence showing panel is no longer in "trouble" mode.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2024
Resolved 27 February 2024
Resolution: Peace of Mind Fire out to check. Loose connection found to be the problem. Connection tightened. all clear
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 February 2024
Resolved
Bilge alarm visual and audible signal in the wheelhouse was not working when test was conducted. Provide audible and visual alarm for bilge high level in the wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2024
Resolved 6 March 2024
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 October 2022
Resolved
Main diesel engines are requires lube oil PSI, jacket
water temperature high water alarm and RPM gauges in the
engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2022
Resolved 8 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 October 2022
Resolved
Auxiliary generator engines are requires lube oil PSI,
jacket water temperature high water alarm and RPM gauges
in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2022
Resolved 8 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 October 2022
Resolved
Hydraulic steering fluid pressure gauge is required for
steering.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2022
Resolved 8 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 October 2022
Resolved
Summary alarm on the bridge must indicate what alarms is
sounding from the main engines and aux generator
engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2022
Resolved 8 November 2022
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 October 2022
Resolved
Fire detection panel has trouble alarms that won't
clear. Panel needs to be tested with an inspector or a
technical report stating everything is operating/tested.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2022
Resolved 8 November 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 October 2022
Resolved
Vsl is required a FCC bridge to bridge certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2022
Resolved 8 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 October 2022
Resolved
All life ring buoys are required retro reflective tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2022
Resolved 8 November 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 July 2022
Resolved
All owners and operators of an existing towing vessel must have onboard a valid COI prior to the specified phase-in period. This vessel has not scheduled an inspection or obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection prior to operation.
Action required: 60 - Rectify deficiencies prior to movement
Due 19 July 2022
Resolved 5 October 2022
Resolution: Vsl has completed an inital COI.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 31 October 2018
Resolved
Vsl is broadcasting invalid IMO # and Vsl is broadcasting incomplete dimension information (AIS Antenna Position "X" equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 January 2025
Resolution: completed