Records from 1993 to 2025. Most recent: inspection, 16 July 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
16 July 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8185560
21 May 2024
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7912837
9 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7893571
20 June 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7721279
12 October 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7576192
1 October 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7336788
27 September 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7066111
19 October 2019
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6837635
16 April 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6663679
18 July 2018
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6476854
27 October 2017
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6294155
18 October 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6026681
15 October 2015
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5743162
7 May 2014
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4869886
8 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4204245
21 September 2010
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3706636
5 August 2008
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3289567
26 September 2007
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3066665
4 September 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3044159
21 August 2006
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2755098
3 August 2005
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2450048
10 June 2005
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2386162
13 October 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2285975
14 September 2004
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2195761
16 July 2003
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1840034
25 September 2002
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1678203
16 January 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1481868
23 May 2001
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1070548
23 October 2000
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1462911
8 November 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1432215
18 November 1998
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1418429
4 November 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 803919
6 November 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1436010
25 November 1996
Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392576
5 December 1995
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 873294
16 November 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1405807
21 November 1994
COI Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 862017
28 June 1993
Plan Review "T" Boat · Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1428257
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2024
Resolved
46 CFR 182.01-5; All machinery be installed and maintained in such a manner as to afford adequate protection against fire. Diesel fuel fill piping and surrounding area showed signs of leaking fuel. Informed owner, vessel not to take on additional fuel until source of leak secured.
Action required: 703 - Prior to bunkering operations
Due 24 May 2024
Resolved 23 May 2024
Resolution: O/O tightened all fittings, no indications of further leaks.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 May 2024
Resolved
A vessel on lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals [...], and Three hand orange smoke distress signals. Vessel only had 03 hand red flare distress signals on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 22 May 2024
Resolution: Purchased additional flares
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 21 May 2024
Resolved
All unfired pressure vessels must be installed to the satisfaction of the cognizant [name withheld] compressor was secured to bulkhead with elastic cording.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 31 May 2024
Resolution: Replaced bungie cords with straps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2022
Resolved
All safety and relief valves shall be set to relieve at a pressure which does not exceed the "maximum allowable working pressure" of the pressure vessel. Vessel's air compressor safety valve is set at a pressure above the "maximum allowable working pressure" of the pressure vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 18 October 2022
Resolution: Vessel representative provided evidence that the air compressor relief valve is set correctly as it relates to the air compressor receiver's Max Allowable Working Pressure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2022
Resolved
Each item of lifesaving equipment must be maintained in a serviceable condition. The Life Ring Buoy on board the vessel was not determined to be in a serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2022
Resolved 18 October 2022
Resolution: Vessel representative provided evidence of the replacement of the old life ring buoy with a new life ring buoy.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 1 October 2021
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Section of deck on the starboard/forward side of the vessel (adjacent to the beginning of the superstructure) has a broken stitch weld on the overhead stiffener beneath the deck.
705 - C: Next Scheduled Dry Dock
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 12 October 2022
Resolution: Repair was made to fix broken stitch weld on the overhead stiffener beneath the deck on the starboard side (adjacent to the beginning of the superstructure).
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 27 September 2020
Resolved
Vessels Certificiate of Documentation was expired.
Action required: 60 - Rectify deficiencies prior to movement
Due 29 October 2020
Resolved 2 October 2020
Resolution: COD renewed and validated in MISLE.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 September 2020
Resolved
Placards containing instructions for the donning and use of life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passangers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2020
Resolved 29 September 2020
Resolution: Master posted instructions IVO life jacket container on second deck which allows passangers to quickly reference instructions.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 September 2020
Resolved
Diesel leak discovered
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2020
Resolved 2 October 2020
Resolution: Pipe union on fuel tank fill pipe tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 October 2019
Resolved
Gauge on air receiver does not reach at least 1.2 times the pressure that the pressure relief valve is set to function.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 28 October 2019
Resolution: Gauge was replaced with 160 psi gauge.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 19 October 2019
Resolved
Owner/operator was not conducting monthly inspections on fire protection equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 28 October 2019
Resolution: All fire extinguishers were inspected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2019
Resolved
Lifeline was not fitted onto ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 28 October 2019
Resolution: Lifeline was fitted onto ring buoy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 19 October 2019
Resolved
Railings are not securely attached to hull structure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 28 October 2019
Resolution: Railings were secured to hull structure.
Lifesaving › Lifebuoys › Serviceable
Issued 27 October 2017
Resolved
Ring lifebuoy was unserviceable due to cracking and sun wear, light attached to buoy was also inoperable. Replace prior to carrying passengers.
Due 27 October 2017
Resolved 27 October 2017
Resolution: Master and Crew purchased new ring buoy and water light to Subchapter T standards.
Engineering › Pressure Vessel › Shell Plate
Issued 27 October 2017
Resolved
80 gallon air receiver atop the pilot house showed significant scaling on internal examination and deterioration on external examination. Prove satisfactory condition of receiver prior to use.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 30 November 2017
Resolution: Procured new pressure vessel
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 October 2015
Resolved
Provide means for port and starboard crew access only gates forward of engine room to be secured in the closed position preventing passengers to proceed aft on vessel, iaw 46 cfr 177.35-1 OLD T.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2015
Resolution: Installed latches to secure doors in the closed position.
Documentation › Markings/Placards › Warning Signs
Issued 20 October 2015
Resolved
Provide placards to prevent passenger access through port and starboard crew access only gates forward of engine room, IAW 46 CFR 176.25-1(A) OLD T.
Action required: 705 - Other - as specified
Due 20 November 2015
Resolved 26 October 2015
Resolution: Installed placards stating CREW ONLY on port and starboard access gates leading aft towards engine room.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 October 2015
Resolved
Battery must be secured to protect against shifting with motion of the vessel, IAW 46 CFR 183.05-20 (b) OLD T.
Action required: 705 - Other - as specified
Due 20 November 2015
Resolved 26 October 2015
Resolution: Installed strap around battery and secured to engine frame mount.
Engineering › Thrusters › Tunnel
Issued 7 May 2014
Resolved
Provide repair proposal and properly repair bow and stern thruster tunnel; significant cavitation and pinholes prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2014
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 May 2014
Resolved
Remove and replace wooden toprails rotted out and water logged from aft #3 & #5 rail and starboard top aft rail #1 IAW 177.900.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2014
Resolved 5 June 2014
Stability › Weathertight Integrity › General
Issued 7 May 2014
Resolved
Remove and replace frames 1 thru 8 due to water intrusion port aft pilot house IAW 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 31 July 2014
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 August 2008
Resolved
Vessel failed to conduct an inspection for renewal of a Certificate of Inspection prior to the July 16, 2008 expiration date, as required by 46 CFR 176.107(b). In addition, vessel operated as a small passenger vessel beyond the 5 year period of validity; thereby, in violation of 46 CFR 100.
Due 8 August 2008
Resolved 15 October 2009
Resolution: Closed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 September 2007
Resolved
Relocate masthead light and demonstrate ability to display light 225 degrees prior to night operations.
Due 8 September 2007
Resolved 7 September 2007
Engineering › Bilge Water Management System › Pump
Issued 4 September 2007
Resolved
Supply portable hand pump capable of getting water from space out to over the side of vessel.
Due 4 October 2007
Resolved 26 September 2007
Resolution: Vessel now has portable hand pump with sufficient hose length to dewater all spaces in vessel.
Engineering › Bilge Water Management System › Piping
Issued 4 September 2007
Resolved
Provide line diagram of bilge piping in engine space.
Due 4 October 2007
Resolved 26 September 2007
Resolution: Line diagram provided and posted.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 September 2007
Resolved
Reduce openings in forward railing to 4 inches or less by next dry dock.
Due 14 September 2009
Resolved 21 October 2011
Resolution: Added webbed netting to current railing to be in compliance with regulations.
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 September 2007
Resolved
Provide proper bilge alarms in spaces with thru-hull fittins by next dry dock.
Due 14 September 2009
Resolved 16 June 2009
Resolution: Provided proper bilge alarms within spaces with thru-hull fittings
Electrical › Electric Generation Source (emergency) › Generator Cable
Issued 4 September 2007
Resolved
Properly cover exposed battery terminals.
Due 4 October 2007
Resolved 26 September 2007
Resolution: Caps were placed over battery terminals.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 4 September 2007
Resolved
Renew or replace bolts and washers on paddle wheel.
Due 4 October 2007
Resolved 26 September 2007
Resolution: All missing or worn bolts and washers were replaced and tightened.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 August 2005
Resolved
Replace stern light light bulb prior to operating at night.
Due 16 August 2005
Resolved 15 August 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 August 2005
Resolved
Repair lagging on main engine exhaust
Due 16 August 2005
Resolved 24 August 2005
Lifesaving › Visual Distress Signals (General) › Storage
Issued 2 August 2005
Resolved
Obtain container for distress flares IAW 46 CFR 185.614
Due 16 August 2005
Resolved 15 August 2005
Documentation › Certificates/Documents
Issued 16 July 2003
Resolved
Vessel did no thave current COD on board due to sale of vessel and processing jam at NVDC. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 16 August 2003
Resolved 19 August 2003
Resolution: Attended vsl and observed valid COD on board.
Lifesaving › Lifejacket/PFD (General)
Issued 16 July 2003
Resolved
Donning placards not provided for type o PFD carried.
Action required: 705 - Other - as specified
Due 16 August 2003
Resolved 19 August 2003
Resolution: Attended vsl and observed donning placards for PFD posted throughout passenger spaces.
Lifesaving › Lifebuoys
Issued 16 July 2003
Resolved
Buoy not provided with buoyant line. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 705 - Other - as specified
Due 16 August 2003
Resolved 19 August 2003
Resolution: Attended vsl and observed new buoyant line attached to buoy.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 16 July 2003
Resolved
Provide guard for moving parts on diesel engine.
Action required: 705 - Other - as specified
Due 16 August 2003
Resolved 19 August 2003
Resolution: Attended vsl and observed newly installed guard to adequately shield moving parts from human contact.
Engineering › Fuel Oil Service System
Issued 16 July 2003
Resolved
Replace fuel supply and return piping due to deteoriation and cracking. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 16 August 2003
Resolved 19 August 2003
Resolution: Attended vsl and observed new tubing for fuel supply and return.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 July 2003
Resolved
Provide additional lagging on exposed portions of exhaust. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 705 - Other - as specified
Due 16 August 2003
Resolved 19 August 2003
Resolution: Attended vsl and observed adequate lagging newly installed on exhaust.
Construction/Loadline › Hull
Issued 25 September 2002
Resolved
Crop and renew port and bow rub rail.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2002
Resolved 4 November 2002
Resolution: Rub rail replaced.
Construction/Loadline › Hull › Hull Plating
Issued 25 September 2002
Resolved
Scrape, clean, treat, paint noted rusted areas in bow compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2002
Resolved 4 November 2002
Resolution: Rusted areas scraped, clean, treated and painted satisfactorily.
Fire Fighting › Fire Main › Condition
Issued 25 September 2002
Resolved
Replace deteriorated fire pump suction pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2002
Resolved 25 September 2002
Resolution: Pipe replaced.
Navigation › Piloting/Steering › Marine Charts
Issued 16 January 2002
Resolved
Update Charts, Lightlist and Coast Pilot
Action required: 705 - Other - as specified
Resolved 16 January 2002
Resolution: Nav Charts and Pubs updated.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 January 2002
Resolved
Provide retroflective tape for Ring Buoy.
Action required: 705 - Other - as specified
Resolved 16 January 2002
Resolution: Retroflective tape provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 January 2002
Resolved
Renew all expired items in first aid kit.
Action required: 705 - Other - as specified
Resolved 16 January 2002
Resolution: First aid kit expired items renewed.
Fire Fighting
Issued 16 November 1995
Resolved
Prior to operating, service portable fire extinguishers.
Condition: Unknown
Due 16 November 1995
Resolved 16 November 1995
Navigation
Issued 16 November 1995
Resolved
Provide compass deviation card for the vessel.
Condition: Unknown
Due 16 November 1995
Resolved 16 November 1995
Navigation
Issued 16 November 1995
Resolved
Provide proper charts and publications appropriate to the vessel's route.
Condition: Unknown
Due 16 November 1995
Resolved 16 November 1995
Lifesaving
Issued 28 June 1993
Resolved
Provide vessel name on all life jackets prior to placing vsl into commercial service.
Condition: Unknown
Due 28 June 1993
Resolved 28 June 1993
Lifesaving
Issued 28 June 1993
Resolved
Conduct fire, man overboard, and flooding drills of crew prior to operationof vessel for carriage of passengers for hire.
Condition: Unknown
Due 28 June 1993
Resolved 28 June 1993
Construction/Loadline
Issued 28 June 1993
Resolved
Provide vessel name placard on Port and Starboard panels.
Condition: Unknown
Due 28 June 1993
Resolved 28 June 1993