MAURY USCG vessel records Sign in
← All vessels

MARINEX

MARINEX is a 1994 tank ship. The Coast Guard has recorded 35 inspections since 1999, most recently in March 2016, along with 11 deficiencies and 8 operational controls.

Records from 1999 to 2016. Most recent: inspection, 15 March 2016.

Built
1994
Last inspected
15 March 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9074420 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
410446
Flag
NORWAY
—
Maury page id
psix-410446

Inspections, by type

…with no type recorded14
Years with a record 12 calendar years (1999–2016)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7649 - Convention (Subpart B), Net Ton
31206 - Dead Weight, Ton
38975 - Displacement, Ton
20593 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 35

15 March 2016 Ballast Water Examination · ISPS III Exam · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5829909
17 December 2015 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5783537
1 December 2015 Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5772817
5 December 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4201787
14 September 2011 ISPS II Exam · Ballast Water Examination · Deficiency Check · COC-CHEM Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4142753
15 September 2010 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3845924
30 November 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3371445
20 September 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3328927
6 September 2008 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3317189
20 June 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3242310
18 June 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3240758
18 June 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3241583
16 June 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3239154
12 January 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3129302
28 March 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2896889
14 March 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2888113
5 February 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2867360
10 October 2006 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2797930
11 August 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2744639
15 March 2006 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2603504
14 November 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2534881
30 October 2005 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2525041
21 October 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2519429
8 October 2005 Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2514888
20 September 2005 Ballast Water Examination · COC-CHEM Renew · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2496386
21 July 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2434159
7 June 2005 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2378311
22 March 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2316569
19 October 2004 COC-CHEM Annual
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2224223
24 July 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2143482
24 October 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1935386
6 October 2003 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1922247
20 February 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 287369
25 November 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 435120
25 November 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 811311

Deficiency record · 11

Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 12 September 2011 Resolved
A tank vessel with the capacity of 250 bbls carrying oil or HAZMAT as cargo must have a means of draining or removing discharged oil or HAZMAT from the enclosed deck containment area. The vessels discharge containment drainage valves on the port side are inoperable.
Action required: 705 - Other - as specified
Due 14 October 2011
Resolved 15 September 2011
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 12 September 2011 Resolved
Oil tankers of 150 gross tons and above shall be equipped with an oil discharge monitoring and control system. The vessel's ODME is currently inoperable. Vessel is prohibited from carrying Annex I cargoes until item is resolved.
Action required: 705 - Other - as specified
Due 14 October 2011
Resolved 28 October 2011
Resolution: Vessel has demonstrated proper operation of ODME.
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 12 September 2011 Resolved
Vessel is required to submit a VCS design for approval by the vessel's class society or USCG. Currently, vessel does not have a current VCS certification by its current Class society.
Action required: 705 - Other - as specified
Due 14 October 2011
Resolved 12 October 2011
Resolution: Received Certificate Marine Vapor Control System U.S. Regulations issued by DNV on 10/05/11 attesting to compliance with 46 CFR Part 39.
Construction/Loadline › Hull › Hull Plating
Issued 6 September 2008 Resolved
The vessel experience a grounding at IMTT St. Rose mm 118.5 LMR. A condition of class was issued for the vessel to repair a 1 x 1 meter indent of web frame 89 inside WBT no. stbd.
Due 18 September 2008
Resolved 6 September 2008
Resolution: Received message from class and class report satisfying requirement
Construction/Loadline › Hull › Hull Plating
Issued 20 June 2008 Resolved
The vessel experienced a grounding at IMTT St. Rose mm 118.5 LMR. A condition of class was issued for the vessel to repair a 1x1meter indent of web frame 89 inside WBT no.2 stbd.
Action required: 705 - Other - as specified
Due 18 September 2008
Resolved 6 September 2008
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 19 October 2004 Resolved
Second source of energy for emergency generating set not capable of starting the emergency generator. 74 Solas II-1/44.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2004
Resolution: Received Class report attesting to satisfactory replacement of second set of batteries for emergency generating set.
Deck/Cargo › Vapor Control Systems
Issued 6 October 2003 Resolved
VCS connections studs missing from port and starboard VCS lines. LEGACY COMPONENT DESC: Piping/Hoses
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 October 2003
Resolved 24 October 2003
Resolution: VAPOR RECOVERY CONNECTIONS STUDS INSTALLED ON PORT AND STARBOARD VCS LINE.
Lifesaving
Issued 20 February 2001 Resolved
Install flame screens on deck fuel oil and lube oil vents.
Condition: Unknown
Due 20 May 2001
Resolved 24 October 2003
Deck/Cargo
Issued 20 February 2001 Resolved
Prove proper operation od ODME to the satisfaction of class prior to returnfrom sailing foreign
Condition: Unknown
Due 20 May 2001
Resolved 24 October 2003
Lifesaving
Issued 25 November 1999 Resolved
Properly service SCBAS and EEBAS IBC 14.2.6.
Condition: Unknown
Due 25 December 1999
Resolved 14 December 1999
Fire Fighting
Issued 25 November 1999 Resolved
Properly service fixed CO2 system and provide servicing report from qualified servicing party SOLAS 74 II-2/21 prior to departure from the Portof Houston._x001C_
Condition: Unknown
Due 25 November 1999
Resolved 8 December 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.