A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting
Issued 25 February 1999
No resolution recorded
PROPERLY INSTALL MISSING POWER VENTILATION FAN LOCATED IN THE UPPER CARGO HOLD, AFT, PORT SIDE NEAR THE CARGO CONTROL ROOM. _x001C_ SOLAS 60 II/47(D).
Condition: Unknown
Due 5 April 1999 — due date passed with no resolution recorded
Electrical
Issued 25 February 1999
Resolved
IDENTIFY ALL BROKEN AND INOPERABLE OVERHEAD LIGHTS/LIGHT COVERS THROUGHOUT THE VESSEL'S CARGO HOLDS AND REPAIR/RENEW AS ORIGINAL AS APPROPRIATE. _x001C_ SOLAS 60 II/27(A)(V).
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Electrical
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL BROKEN LIGHT ON THE PORT SIDE OF THE AFTER LOWER CARGO HOLD._x001C_ SOLAS 60 II/27(A)(VI)
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Fire Fighting
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF FIREMAIN PIPING IN THE _x001C_ ENGINEROOM LOCATED NEAR THE BILGE PUMP WHERE TEMPORARY SOFT PATCH IS CURRENTLY INSTALLED._x001C_ SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Fire Fighting
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF FIXED FOAM PIPING IN THE _x001C_AFTER LOWER CARGO HOLD IN WAY OF THE STARBOARD SIDE OVERHEAD._x001C_ SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL DAMAGED FIREMAIN BRANCH PIPING IN THE LOWER AFTER CARGO HOLD STARBOARD SIDE._x001C_ SOLAS 74(AMENDED)II-2/21
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Electrical
Issued 25 February 1999
Resolved
PROPERLY INSTALL MISSING CONTROL SWITCH FOR THE VENTILATION FAN LOCATED ON THE STARBOARD SIDE FORWARD IN THE LOWER AFTER HOLD._x001C_ SOLAS 60 II/47(D)
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
IDENTIFY ALL MISSING/BROKEN FOAM SYSTEM NOZZLES AND REPLACE/RENEW AS_x001C_ APPROPRIATE._x001C_ SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Electrical
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL BROKEN WIRE SUPPORTS LOCATED ON THE PORT SIDE OF THE AFTER LOWER CARGO HOLD._x001C_ SOLAS 60 II/27(A)(VI)
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF FIREMAIN PIPING IN WAY OF_x001C_THE DISCHARGE FROM THE MAIN FIREPUMP WHERE TEMPORARY CEMENT AND SOFT PATCH_x001C_ARE LOCATED._x001C_ SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF FIREMAIN PIPING IN THE AFTER LOWER CARGO HOLD IN WAY OF THE STARBOARD SIDE OVERHEAD._x001C_ SOLAS 74(AMENDED)II-2/21
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL ALL DAMAGED FIXED SPRINKLING SYSTEM BRANCH LINES_x001C_ ON THE PORT SIDE OF THE AFTER LOWER CARGO HOLD._x001C_ SOLAS 74(AMENDED(II-2/21
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Lifesaving
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL ALL DETERIORATED GRAB LINES ON THE VESSEL'S LIFERING BUOYS._x001C_ SOLAS 74(AMENDED) III/20.2
Condition: Unknown
Due 26 February 1999
Resolved 10 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL FIXED SPRINKLING SYSTEM BRANCH LINE IN THE LOWER AFTER CARGO HOLD IN WAY OF CARGO RAMP SO THAT THE NOZZLES FACE DIRECTLY DOWNWARD. SOLAS 74 (AMENDED) II-2/21.
Condition: Unknown
Due 3 March 1999
Resolved 10 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS AT THE NEXT U.S. PORT, PROVE THE PROPER OPERATION OF THE VESSEL'S FIXED SPRINKLING SYSTEM TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR._x001C_ SOLAS 74 (AMENDED) II-2/21.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Fire Fighting
Issued 25 February 1999
Resolved
PROVE THE PROPER OPERATION OF THE VESSEL'S PERMANENT EMERGENCY FIRE PUMP. VESSEL HAS INSTALLED TEMPORARY PORTABLE FIRE PUMP TO THE SATISFACTION OF CLASS AND THE U.S. COAST GUARD. SEE SOLAS 74(AMENDED) II 2/21 AND SOLAS 60II/65(B)(II).
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Deck/Cargo
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL INOPERABLE POWER VENTILATION FAN LOCATED IN THE LOWER FORWARD CARGO HOLD STARBOARD SIDE._x001C_ SOLAS 60 II/47(D)
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Deck/Cargo
Issued 25 February 1999
No resolution recorded
PROPERLY INSTALL MISSING POWER VENTILATION FAN LOCATED IN THE LOWER FORWARDCARGO HOLD PORT SIDE._x001C_ SOLAS 60 II/47(D)_x001C_
Condition: Unknown
Due 5 April 1999 — due date passed with no resolution recorded
Deck/Cargo
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL INOPERABLE POWER VENTILATION FAN LOCATED IN THE BALLAST STABILIZATION ROOM._x001C_ SOLAS 60 II/47(D)
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Electrical
Issued 25 February 1999
Resolved
PROPERLY INSTALL A COVER OVER THE EXPOSED JUNCTION BOX LOCATED IN THE UPPERCARGO HOLD IN WAY OF THE LADDER LEADING TO THE LOWER AFTER CARGO HOLD._x001C_ SOLAS 60 II/27(A)(IV)(2)
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF FOAM PIPING LOCATED IN THEFOAM ROOM._x001C_ SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF EXHAUST PIPING FOR THE_x001C_ EMERGENCY FIREPUMP._x001C_ SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Fire Fighting
Issued 25 February 1999
Resolved
REPAIR/RENEW AS ORIGINAL DAMAGED SECTION OF FIREMAIN PIPING LOCATED NEAR THE STAIRWAY ON THE UPPER CARGO DECK._x001C_ SOLAS 74(AMENDED)II-2-21._x001C_
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
REMOVE PLUGS FROM THE FIXED FOAM SYSTEM NOZZLES LOCATED IN THE STOREROOM_x001C_ ON THE UPPER CARGO DECK._x001C_ SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
PROPERLY NOTE THE LOCATION OF ALL POWER VENTILATION FANS, FAN CONTROLS,_x001C_ AND THE IDENTIFICATION OF EACH FAN ON THE VESSEL'S FIRE CONTROL PLAN._x001C_ SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
PROPERLY PRESSURE TEST ALL DETERIORATED FIRE HOSES IDENTIFIED DURING INSPECTION USING THE VESSEL'S MAIN FIRE PUMP AND REPLACE ALL HOSES THAT FAIL THE TEST._x001C_ SOLAS 74(AMENDED)II-2/21
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Fire Fighting
Issued 25 February 1999
Resolved
PREFORM A FIRE DRILL TO THE SASTISFACTION OF THE ATTENDING U.S. COAST GUARDMARINE INSPECTOR._x001C_ SOLAS 74(AMENDED)III/19.3.4
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Lifesaving
Issued 25 February 1999
Resolved
PREFORM AN ABANDON SHIP DRILL TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR._x001C_ SOLAS 74(AMENDED)III/19.3.3
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999
Navigation
Issued 25 February 1999
Resolved
PREFORM AN EMERGENCY STEERING TEST TO THE SATISFACTION OF THE ATENDING U.S.COAST GUARD MARINE INSPECTOR._x001C_ SOLAS 60 II/29
Condition: Unknown
Due 26 February 1999
Resolved 8 March 1999