Records from 2016 to 2026. Most recent: inspection, 3 March 2026.
Inspection history · 22
3 March 2026
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8318410
27 August 2025
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8219473
26 February 2025
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8084752
12 February 2024
Annual Inspection · Damage Survey · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7851756
7 September 2023
Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7734769
12 April 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7667062
14 September 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7559068
16 January 2022
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7381126
18 November 2021
Deficiency Check · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7353373
15 October 2021
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7345184
4 December 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7106463
27 January 2020
DAPI Audit · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6896079
23 December 2019
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6878584
18 September 2019
Examination of Repairs · Hull Examination · Drydock Exam · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6790384
12 February 2019
Examination of Repairs · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6624197
10 February 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6623227
4 February 2019
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6774876
14 January 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6610017
30 October 2017
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6297323
4 October 2017
Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6286101
25 October 2016
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6029090
12 February 2016
Annual Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5819862
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 26 February 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Post emergency instructions in main deck visible to passengers and crew. 46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 10 March 2025
Resolution: Emergency instructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 26 February 2025
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Life float painter line was found kinked, not able to be release free. 46 CFR 180.175 (d).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 10 March 2025
Resolution: Line was unkinked and rearanged for easy release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 February 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 19 adult-sized life-jackets retro-reflective material was found worn and deteriorated. 46 CFR 180.71.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 10 March 2025
Resolution: New retro-reflective material was installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 February 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Repair wood rot found above the center window, main deck forward. 46 CFR 177.100.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 10 March 2025
Resolution: Wood rot was repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2025
Resolved
Nonmetallic flexible hoses conforming to SAE J1942 may be used without length limitations provided they do not penetrate watertight bulkheads and decks. Flexible fuel hoses were found penetrating watertight bulkheads both port and starboard side hulls. 46 CFR 46.60-25
46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2025
Resolved 8 April 2025
Resolution: Vessel was repaired as it was original, penetration of the WTD were removed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 12 February 2024
Resolved
A vessel must comply with the structural design standards listed in the standards for the hull material of the vessel. Cracks in wood ring frames or composite resin attaching ring frames by tabbed in method in port side hull. Frame #6 from FWD, cracked at sistered transverse frames forming floor. Both sistered transverse frames are cracked. Upper ring frame tabs at frame #6 from FWD disbonded from deck clamp/shelf at deck joint. Ring frame #8 from forward cracked full thickness in starboard bilge to floor. Provide repair proposal.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2024
Resolved 7 May 2024
Resolution: Ring frames repaired as per proposal.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 February 2024
Resolved
Bilges may be examined to see there is no excessive accumulation of oil, trash, debris, or other matter that might clog bilge pumping systems. Limber holes clogged with debris in both hulls.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2024
Resolved 7 May 2024
Resolution: Bilges limber hole were cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 February 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets are stowed on top of adult life jackets without life jacket location markings.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2024
Resolved 7 May 2024
Resolution: Bag for children's lifejackets added to the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 February 2024
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. Several jackets are either missing vessel name marking or are severely faded.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 February 2024
Resolution: All life jackets were marked with permanent black marker with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 February 2024
Resolved
Each life jacket must be marked with type 1 retroreflective material. Several life jackets had deteriorated retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 February 2024
Resolution: New retroreflective tape applied to jackets requiring tape replacement.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 February 2024
Resolved
Starboard hull, frame 21-4 overhead transverse deck beam framing cut out. Provide plan to reinstall to plan scantling or equivalent structural strength.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 May 2024
Resolution: Overhead transverse deck beam restored to original design.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 20 January 2022
Resolved
Vessel needs to complete first aid kit according to the requirements listed in 46 CFR 106.041-4. Ammonia tablets needed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 28 January 2022
Resolution: Vessel attained the reqired ammount of ammonia capsules for the first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 January 2022
Resolved
Life float paddles were not lashed to the life float. Paddle should be lashed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 25 January 2022
Resolution: Life paddles fastened with a yellow line to the life raft.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 4 December 2020
Resolved
When life floats are stowed in tiers, the separate units must be kept apart by spacers. The life floats were not separated by any type of spacer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2020
Resolved 8 January 2021
Resolution: Image sent to office.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 4 December 2020
Resolved
Life floats must have a float-free link formed from a single salt water corrosion-resistant wire with a waterproof identification tag attached. The identification tag was deteriorated and buried underneath the spool.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2020
Resolved 14 December 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 December 2020
Resolved
Each vessel must be equipped with at least two operable portable battery lights. The vessel only had one flashlight on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2020
Resolved 14 December 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 December 2020
Resolved
Drills shall be documented with the date of the drill, and a general description of the scenario and training topics. Vessel logs did not include sufficient detail for drill scenarios.
Action required: 10 - Deficiency Rectified
Resolved 4 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 January 2020
Resolved
Life floats must be separated by spacers. The two life floats were not separated by a spacer. IAW 46 CFR 180.137(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2020
Resolved 27 January 2020
Resolution: Spacers were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 January 2020
Resolved
Life floats must be inspected to ensure its readiness for use. Net and wire are damaged. Total POB reduced to 16 until repairs are completed. IAW 46 CFR 185.720
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2020
Resolution: Repairs have been made.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 January 2020
Resolved
A vessel must have current tables on board. The vessel did not have current tables on board. IAW 46 CFR 184.420
Action required: 10 - Deficiency Rectified
Resolved 27 January 2020
Resolution: Current table printed out and on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 January 2020
Resolved
A ring buoy must be installed with a corrosion resistant clip. Ring buoy did not have clip. IAW 46 CFR 180.70.
Action required: 10 - Deficiency Rectified
Resolved 27 January 2020
Resolution: New ring buoy installed on boat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 January 2020
Resolved
A vessel must have (06) hand orange and (06) hand red flares. The vessel is missing (02) red flares. IAW 46 CFR 180.68(a)
Action required: 10 - Deficiency Rectified
Resolved 27 January 2020
Resolution: Two additional red flares purchased.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 February 2019
Resolved
Repair damaged to starboard transom and midsection cleat that was pulled out. As per repair propolsal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2019
Resolution: All repairs have been completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 February 2019
Resolved
There must be a means of accurately determining the amount of fuel in each fuel tank either by sounding, through a separate sounding pipe or a fill pipe, or by an installed marine type fuel gauge. The fuel gauge was stuck on "F", therefore not providing an accurate reading, resulting in the boat running out of fuel.
Action required: 10 - Deficiency Rectified
Resolved 13 February 2019
Resolution: the mechanic adjusted the float switch and the gauge showed the proper reading.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 January 2019
Resolved
Provide maintenance to both life floats. Several life lines were dry-rotted and needs replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2019
Resolved 15 March 2019
Resolution: Replaced all lines on life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 January 2019
Resolved
Repair/Replace painter line container. Container has several broken spot welds.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2019
Resolved 13 February 2019
Resolution: Replaced container.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 15 January 2019
Resolved
Properly stow and attached life floats to be float-free.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2019
Resolved 13 February 2019
Resolution: Completed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 January 2019
Resolved
Provide 2 more 2 1/2 gal. fire buckets and properly label.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2019
Resolved 13 February 2019
Resolution: Completed
Stability › Weathertight Integrity › General
Issued 30 October 2017
Resolved
Forward windows must be installed to the satifaction of the attending marine inspector.
46 CFR 177.1020
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2017
Lifesaving › Lifefloat › Serviceable
Issued 30 October 2017
Resolved
Repair coating on the underside of the top lifefloat.
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 8 November 2017
Engineering › Bilge Water Management System › Not Operational
Issued 25 October 2016
Resolved
Prove proper operation of port bilge high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2017
Resolution: Operator proved operation of the alarm.
Fire Fighting › Fire Bucket › Quantity
Issued 25 October 2016
Resolved
Replace missing fire bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2017
Resolution: Operator provided the additional fire bucket onboard.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 25 October 2016
Resolved
Replace ring buoy battery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: The vessel representative replaced the battery during the inspection.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 25 October 2016
Resolved
Mark the vessel name on port and starboard bow.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2017