MAURY USCG vessel records
← All vessels

USNS PATHFINDER

USNS PATHFINDER is a 1994 research vessel. The Coast Guard has recorded 31 inspections since 2016, most recently in April 2026, along with 26 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 28 April 2026.

Built
1994
Last inspected
28 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 April 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9075199
410762
Flag
UNITED STATES
Maury page id
psix-410762

Documentation record

Tonnage as PSIX records it4260 - Convention (Subpart B), Gross Ton
1278 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 31

28 April 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8357165
6 February 2026 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8307029
1 February 2026 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8304950
21 October 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8289397
7 October 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8259443
6 October 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8259234
11 August 2025 Excursion Permit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8208382
10 July 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8187122
14 April 2025 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8113831
10 March 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8095548
7 March 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8090181
10 February 2025 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8078179
4 April 2024 ACP Drydock Oversight · Re-Inspection · ACP COI Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7888594
8 December 2023 Administrative Inspection · Excursion Permit
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7836665
15 August 2023 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 7768721
1 May 2023 Excursion Permit
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7678552
11 January 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7720870
11 July 2022 Administrative Inspection · ACP Annual Oversight · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7587873
28 January 2022 Special · Administrative Inspection · ACP Drydock Oversight
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7387312
26 August 2021 Periodic Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 7300081
2 March 2021 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7149454
12 August 2020 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7043601
28 May 2019 Annual Inspection · ACP Drydock Oversight · Deficiency Check · ACP COI Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6696740
11 April 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6664197
14 August 2018 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 6487837
4 May 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6405670
1 December 2017 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6322624
5 July 2017 Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6198056
19 August 2016 ACP Annual Oversight
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5976981
21 July 2016 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5948271
8 February 2016 Excursion Permit
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5811567

Deficiency record · 26

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2026 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Master reported the loss of the starboard propulsion motor (azimuth Z-Drive). Affect repairs to the satisfaction of the RO / Coast Guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2026
Resolved 11 May 2026
Resolution: Received ABS Class Report detailing affected repairs and satisfactory testing.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 February 2026 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Crew discovered a quarter-size hole in a flange downstream of the emergency fire pump and made temporary repairs. Affect repairs to the satisfaction of the RO/Coast Guard prior to departing Port Everglades. SOLAS (2020) II-2 /Reg 14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2026
Resolved 6 February 2026
Resolution: ABS attended vessel and verified corrected. Report added.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 August 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if fire occurs: fire detection and fire alarm systems. Interview with the crew indicates that the system is fully operational but is unable to clear the “trouble” in the system. Hiller System provided report 08May2023 with no indication of “trouble” in system. Cite: SOLAS II-2 (2020)/Reg 14.2.1.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Received finding number 1242.0 from ABS Jacksonville.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 23 August 2023 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensure reliability of such appliances. Identified steel plate corrosion in both lifeboat internal release mechanism support system. The annual inspection was completed by Palfinger in Apr 2023, with no noted concerns or notation of condition of these areas. Cite: SOLAS (2020) III/Reg 20.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1243.0 issued by ABS Jacksonville.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 August 2023 Resolved
Spares and repair equipment shall be provided for lifesaving appliances and their components which are subject to excessive wear or consumption and need to be replaced regularly. Noted cracking in port lifeboat (stbd/inboard side) gel coating and the ship does not maintain a repair kit to address this area. Cite: SOLAS (2020) III/Reg 20.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1243.0 issued by ABS Jacksonville.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 August 2023 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. •During fire drill, galley door was found locked, and crew unable to enter through this door. Door is a selfclosing door, with closing hinge disconnected from door frame. Also, found hook tie-back attached to door/ bulkhead. •Adjust self-closing door to pump room 3-73-0. Cite: SOLAS (1997) II-2/Reg 47.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1244.0 issued by ABS Jacksonville.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 August 2023 Resolved
Crowns and casing of machinery spaces of category A shall be of steel construction adequately insulated and openings… shall be suitably arranged and protected to prevent the spread of fire. • At MVZ-24 overhead (BOSN stores) two sections of insulation missing. • Tape missing in overhead in fwd pump room. Cite: SOLAS II-2 (1997) / Reg 42.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1245.0 issued by ABS Jacksonville.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2023 Resolved
Electrical Installations shall be such that the safety of crew and ship from electrical hazards will be ensured. The following light fixtures were found with broken diffusers (IEEE: 33.14): • Bosn store room (x3 lights) • Pump room • Throughout High Density room • Fan space by library • Stairway (2nd platform) above door to Passage 3-65-0 • Fix lights in overhead in linen locker and adj cleaning gear locker The following improper electrical connections were identified (IEEE 23.6): •Replace/repair electrical cable for lights on stbd bridge wing and other light fixtures on deck •Junction box cover detached by light in stairwell (near Bow Thruster control panel -Bosn stores?) •SOPEP locker (above light) has cable terminations with wire nuts not in junction box •In High Density room, junction box by emergency escape hatch has wire backing out •Improper electrical connection for special winch system• Cable penetration on bottom right side of MSD control panel • GMDSS battery cable insulation is deteriorated and shows signs of possible splice (46 CFR 111.60-19) Cite: SOLAS (1997) II-1/Reg 40.1.3; 46 CFR 110.10-1(b)(4)(iii) (old J); IEEE-45-1983
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1246.0 issued by ABS Jacksonville.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2023 Resolved
The Administration shall take appropriate steps to ensure uniformity in the implementation and application of the provisions of this part in respect of electrical installations. The following items were identified using daisy chains and portable cables (extension cords), which should be permanently wired (IEEE 19.6.1) •Daisy chain and splice in cable for intrinsically safe lights in fwd fire locker. •Daisy chain in Bosn locker. The following wiring items were identified (IEEE: 20.2): • Dead end wires on stbd side bridge (external windows) • Dead end wire in deck penetration on aft port side between rail course and conex box • Cable termination for freezer fan unit not in junction box (IEEE: 21.43) Cite: SOLAS (1997) II- 1/Reg 40.2; 46 CFR 110.10-1(b)(4)(iii) (old J); IEEE-45-1983
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1246.0 issued by ABS Jacksonville.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 August 2023 Resolved
The Administration shall take appropriate steps to ensure uniformity in the implementation and application of the provisions of this part in respect of electrical installations. The following items for unsupported electrical cables were identified (IEEE 23.9): • Unsupported cables in aft part of aft fire locker, and cables resting on edge of metal cabinet. • Electrical cables running from conex boxes on aft deck are not properly secured and are improperly connected to service panel box in aft vestibule [and also IEEE 23.9/23.10, 46 CFR 195.11-25(a)(1)] • Electrical cables are not properly supported in wire run above Main deck stairway Passage 1-24-1 (including dead end wires) and also FSD 1-72-1. Cite: SOLAS (1997) II- 1/Reg 40.2; 46 CFR 110.10-1(b)(4)(iii) (old J); IEEE-45-1983
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1246.0 issued by ABS Jacksonville.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 August 2023 Resolved
Guard rails or bulwarks shall be fitted around all exposed decks. Rail courses were missing between newly installed Conex Box (port side aft) and port beam/ fantail railing. Cite: ILLC Reg 25(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1247.0 issued by ABS Jacksonville.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 August 2023 Resolved
All waste receptacles shall be constructed of noncombustible materials with no openings in the sides or bottom. Plastic trash cans, including plastic waste receptacle were used for oily rags. Cite: SOLAS (1997) II-2/Reg 18.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1245.0 issued by ABS Jacksonville.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 23 August 2023 Resolved
Medical waivers may be granted with specific conditions to which the applicant must adhere, such as more frequent monitoring of the medical conditions, submission of medical exams and/or tests at varying intervals to track the ongoing status of the medical condition, or operational limitations in the manner the mariner may serve under the MMC. • 03 crew members were missing medical certificate waivers. • Current steward med certificate indicated not fit for food handling. Steward recently received new medical certificate and provided documentation supporting no medical issues. Provide supporting documentation from NMC of updated medical certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 22 September 2023
Resolution: The crewmembers with missing medical waivers were located for two crew members 2AE and 3AE) and two crew members departed (MED and STU).
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 17 August 2023 Resolved
The training manual…shall contain instructions and information, in easily understood term illustrated wherever possible, on the lifesaving appliances provided in the ship and ton the best methos of survival. The immersion suits found in the SOLAS training manual were for a different model than crew had on board. Cite: SOLAS (2020) III/Reg 35.3
Action required: 10 - Deficiency Rectified
Resolved 18 August 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 August 2023 Resolved
Two means of escape shall be provided from each machinery space of category A. A box was stored in emergency escape ladder. Cite: SOLAS (1997) II-2/Reg 45
Action required: 10 - Deficiency Rectified
Resolved 18 August 2023
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 26 August 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. There is a steady drip of hydraulic oil from a linkage between the pump motors on the tank top.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 13 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 August 2021 Resolved
The following fire protection systems shall be kept in good order so as to endure their required performance if a fire occurs: structural fire protection including fire resisting divisions, and protection of openings and penetrations in these divisions. A rock block type multi-cable transit installation in the steering gear room is not installed correctly, pieces are protruding or recessed and should be installed as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 13 October 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 August 2021 Resolved
Doors provided to ensure the watertight integrity of internal openings which are used while at sea are to be sliding watertight doors capable of being remotely closed from the bridge and are also to be operable locally from each side of the bulkhead. The WTD on winch room fwd bulkhead has a faulty power switch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 13 October 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 August 2021 Resolved
Power control systems shall close doors at an approximate uniform rate of closure, but in no case shall the closure time, from the time a door begins to move to the time it reaches the fully closed position, be less than 20 s or more than 40 s. Vsl's Class 3 WTDs reached complete closure after 1 minute.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 13 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2021 Resolved
Maintenance of conditions after survey. On 3/2/2021 at approximately 2330 Sector Virginia Command Center received a report of a fire in the starboard thruster room that occurred at 2130 in the brake band of the starboard thruster. 74 SOLAS (14) I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 4 March 2021
Resolution: ABS provided class report
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 26 August 2019 Resolved
Vessel has posted through-out the ship Fire Control Plans (FCP) that are Revision "A". The most current revision on the bridge is Revision "D". Plans shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. The total number of FCPs on-board shall be the amount as indicated on the FCP Revision "D".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 29 August 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 August 2019 Resolved
The Recognized Organization is in the process of issuing certificates; the certificates issued shall be readily available on board for examination. The RO shall emails electronic copies to USCG before departure CLEARED
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2019
Resolved 26 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 August 2019 Resolved
The following fire doors are not closing on their own: laundry room doors / door leading into draft room from main lab: fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 26 August 2019
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 26 August 2019 Resolved
The following flood/over the side lights need to be properly mounted; starboard bridge wing light is secured with a line, port side at bottom of ladder light is just laying on the deck; electrical apparatus shall be installed as not to cause injury when handled or touched in the normal manner
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 26 August 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 August 2019 Resolved
Make repairs to the small oil leak on the #1 ship service diesel generator turbo flange. Means shall be provided to control leaks of flammable liquids; The arrangements of distribution and utilization of oils shall be such as to ensure the safety of the ship and persons on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 26 August 2019
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 May 2019 Resolved
The port outboard steering pump is acting and making a abnormally loud noise,the pump needs to be investigate /trouble shoot to see the cause of the noise and make repairs as needed. The ships equipment shall be maintained to conform with the present regulations to ensure that the ship may fit to proceed to sea.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2019
Resolved 26 August 2019

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.