USNS PATHFINDER is a 1994 research vessel. The Coast Guard has recorded 108 inspections since 1994, most recently in April 2026, along with 88 deficiencies.

Records from 1994 to 2026. Most recent: inspection, 28 April 2026.

Built
1994
Last inspected
28 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9075199 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
410762
Flag
UNITED STATES
—
Maury page id
psix-410762

Inspections, by type

…with no type recorded24
Years with a record 31 calendar years (1994–2026)
The 108 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4260 - Convention (Subpart B), Gross Ton
1278 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 108

28 April 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8357165
6 February 2026 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8307029
1 February 2026 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8304950
21 October 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8289397
7 October 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8259443
6 October 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8259234
11 August 2025 Excursion Permit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8208382
10 July 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8187122
14 April 2025 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8113831
10 March 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8095548
7 March 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8090181
10 February 2025 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8078179
4 April 2024 ACP Drydock Oversight · Re-Inspection · ACP COI Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7888594
8 December 2023 Administrative Inspection · Excursion Permit
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7836665
15 August 2023 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 7768721
1 May 2023 Excursion Permit
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7678552
11 January 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7720870
11 July 2022 Administrative Inspection · ACP Annual Oversight · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7587873
28 January 2022 Special · Administrative Inspection · ACP Drydock Oversight
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7387312
26 August 2021 Periodic Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 7300081
2 March 2021 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7149454
12 August 2020 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7043601
28 May 2019 Annual Inspection · ACP Drydock Oversight · Deficiency Check · ACP COI Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6696740
11 April 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6664197
14 August 2018 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 6487837
4 May 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6405670
1 December 2017 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6322624
5 July 2017 Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6198056
19 August 2016 ACP Annual Oversight
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5976981
21 July 2016 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5948271
8 February 2016 Excursion Permit
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5811567
10 August 2015 Type not recorded
No type recorded · Activities Europe · Activity 5213554
26 August 2014 Annual Inspection · DAPI Audit · ACP Annual Oversight · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4965726
24 March 2014 Excursion Permit
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4821720
13 June 2012 Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4342711
3 June 2012 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4344672
23 May 2012 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 4319361
9 December 2011 Excursion Permit
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4204858
13 January 2011 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 3925773
16 September 2010 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3870448
9 October 2008 Underwater Inspection in lieu of Drydock · Internal Structural Exam · ACP Periodic Oversight
Physical examination · Activities Europe · Activity 3394492
14 September 2008 Type not recorded
No type recorded · Activities Europe · Activity 3383570
28 May 2008 Administrative Inspection
Administrative · Activities Europe · Activity 3219933
19 April 2007 Excursion Permit
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2911056
11 February 2007 Administrative Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2870998
21 June 2006 Excursion Permit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2687529
7 June 2006 Excursion Permit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2673377
9 January 2006 In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2576695
14 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2535901
27 September 2005 COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2493931
15 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293068
9 February 2005 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2289398
8 February 2005 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2295072
7 November 2004 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2234376
28 September 2004 Excursion Permit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2209179
23 August 2004 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2174116
22 June 2004 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2109088
20 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104734
29 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996892
16 December 2003 ACP COI Oversight
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1964941
18 November 2003 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1950696
17 October 2003 Excursion Permit
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1930435
12 June 2003 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1815714
20 March 2003 Excursion Permit
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1763669
31 January 2002 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1482962
7 November 2001 Annual Inspection · Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1466256
14 April 2001 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1465632
31 October 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1055015
30 September 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389213
15 September 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1054632
6 April 2000 Excursion Permit
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 816747
13 October 1999 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1413628
26 July 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 224172
26 July 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1488245
31 January 1999 Hull Examination
Physical examination · Activities Europe · Activity 1365027
31 December 1998 Deficiency Check
Physical examination · Activities Europe · Activity 810372
29 October 1998 COI Inspection
Physical examination · Activities Europe · Activity 1364907
8 July 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 222657
19 May 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438732
13 December 1997 Re-Inspection
Physical examination · Activities Europe · Activity 1364503
6 December 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 72646
3 October 1997 Administrative
Administrative · Activities Europe · Activity 1121290
3 September 1997 Deficiency Check
Physical examination · Activities Europe · Activity 1119862
23 July 1997 Administrative
Administrative · Activities Europe · Activity 1459330
20 June 1997 Administrative
Administrative · Activities Europe · Activity 1112146
2 June 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447718
30 May 1997 Excursion Permit
Administrative · Activities Europe · Activity 1108567
21 May 1997 Administrative
Administrative · Activities Europe · Activity 1098419
3 April 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1103058
26 March 1997 Administrative
Administrative · Activities Europe · Activity 1091680
10 February 1997 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1104397
31 December 1996 Deficiency Check
Physical examination · Activities Europe · Activity 1096929
26 November 1996 Type not recorded
No type recorded · Activities Europe · Activity 86648
6 November 1996 COI Inspection
Physical examination · Activities Europe · Activity 1357777
23 October 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1159438
13 September 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 954217
24 June 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1082350
23 May 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1084098
20 May 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1447588
17 May 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1084049
22 March 1996 Re-Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1402214
28 December 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 875003
29 November 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 886102
25 August 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 879737
19 June 1995 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1439636
15 May 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 66913
5 December 1994 COI Inspection · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1163465
30 July 1994 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 867642

Deficiency record · 88

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2026 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Master reported the loss of the starboard propulsion motor (azimuth Z-Drive). Affect repairs to the satisfaction of the RO / Coast Guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2026
Resolved 11 May 2026
Resolution: Received ABS Class Report detailing affected repairs and satisfactory testing.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 February 2026 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Crew discovered a quarter-size hole in a flange downstream of the emergency fire pump and made temporary repairs. Affect repairs to the satisfaction of the RO/Coast Guard prior to departing Port Everglades. SOLAS (2020) II-2 /Reg 14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2026
Resolved 6 February 2026
Resolution: ABS attended vessel and verified corrected. Report added.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 August 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if fire occurs: fire detection and fire alarm systems. Interview with the crew indicates that the system is fully operational but is unable to clear the “trouble” in the system. Hiller System provided report 08May2023 with no indication of “trouble” in system. Cite: SOLAS II-2 (2020)/Reg 14.2.1.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Received finding number 1242.0 from ABS Jacksonville.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 23 August 2023 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensure reliability of such appliances. Identified steel plate corrosion in both lifeboat internal release mechanism support system. The annual inspection was completed by Palfinger in Apr 2023, with no noted concerns or notation of condition of these areas. Cite: SOLAS (2020) III/Reg 20.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1243.0 issued by ABS Jacksonville.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 August 2023 Resolved
Spares and repair equipment shall be provided for lifesaving appliances and their components which are subject to excessive wear or consumption and need to be replaced regularly. Noted cracking in port lifeboat (stbd/inboard side) gel coating and the ship does not maintain a repair kit to address this area. Cite: SOLAS (2020) III/Reg 20.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1243.0 issued by ABS Jacksonville.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 August 2023 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. •During fire drill, galley door was found locked, and crew unable to enter through this door. Door is a selfclosing door, with closing hinge disconnected from door frame. Also, found hook tie-back attached to door/ bulkhead. •Adjust self-closing door to pump room 3-73-0. Cite: SOLAS (1997) II-2/Reg 47.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1244.0 issued by ABS Jacksonville.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 August 2023 Resolved
Crowns and casing of machinery spaces of category A shall be of steel construction adequately insulated and openings… shall be suitably arranged and protected to prevent the spread of fire. • At MVZ-24 overhead (BOSN stores) two sections of insulation missing. • Tape missing in overhead in fwd pump room. Cite: SOLAS II-2 (1997) / Reg 42.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1245.0 issued by ABS Jacksonville.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2023 Resolved
Electrical Installations shall be such that the safety of crew and ship from electrical hazards will be ensured. The following light fixtures were found with broken diffusers (IEEE: 33.14): • Bosn store room (x3 lights) • Pump room • Throughout High Density room • Fan space by library • Stairway (2nd platform) above door to Passage 3-65-0 • Fix lights in overhead in linen locker and adj cleaning gear locker The following improper electrical connections were identified (IEEE 23.6): •Replace/repair electrical cable for lights on stbd bridge wing and other light fixtures on deck •Junction box cover detached by light in stairwell (near Bow Thruster control panel -Bosn stores?) •SOPEP locker (above light) has cable terminations with wire nuts not in junction box •In High Density room, junction box by emergency escape hatch has wire backing out •Improper electrical connection for special winch system• Cable penetration on bottom right side of MSD control panel • GMDSS battery cable insulation is deteriorated and shows signs of possible splice (46 CFR 111.60-19) Cite: SOLAS (1997) II-1/Reg 40.1.3; 46 CFR 110.10-1(b)(4)(iii) (old J); IEEE-45-1983
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1246.0 issued by ABS Jacksonville.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2023 Resolved
The Administration shall take appropriate steps to ensure uniformity in the implementation and application of the provisions of this part in respect of electrical installations. The following items were identified using daisy chains and portable cables (extension cords), which should be permanently wired (IEEE 19.6.1) •Daisy chain and splice in cable for intrinsically safe lights in fwd fire locker. •Daisy chain in Bosn locker. The following wiring items were identified (IEEE: 20.2): • Dead end wires on stbd side bridge (external windows) • Dead end wire in deck penetration on aft port side between rail course and conex box • Cable termination for freezer fan unit not in junction box (IEEE: 21.43) Cite: SOLAS (1997) II- 1/Reg 40.2; 46 CFR 110.10-1(b)(4)(iii) (old J); IEEE-45-1983
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1246.0 issued by ABS Jacksonville.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 August 2023 Resolved
The Administration shall take appropriate steps to ensure uniformity in the implementation and application of the provisions of this part in respect of electrical installations. The following items for unsupported electrical cables were identified (IEEE 23.9): • Unsupported cables in aft part of aft fire locker, and cables resting on edge of metal cabinet. • Electrical cables running from conex boxes on aft deck are not properly secured and are improperly connected to service panel box in aft vestibule [and also IEEE 23.9/23.10, 46 CFR 195.11-25(a)(1)] • Electrical cables are not properly supported in wire run above Main deck stairway Passage 1-24-1 (including dead end wires) and also FSD 1-72-1. Cite: SOLAS (1997) II- 1/Reg 40.2; 46 CFR 110.10-1(b)(4)(iii) (old J); IEEE-45-1983
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1246.0 issued by ABS Jacksonville.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 August 2023 Resolved
Guard rails or bulwarks shall be fitted around all exposed decks. Rail courses were missing between newly installed Conex Box (port side aft) and port beam/ fantail railing. Cite: ILLC Reg 25(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1247.0 issued by ABS Jacksonville.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 August 2023 Resolved
All waste receptacles shall be constructed of noncombustible materials with no openings in the sides or bottom. Plastic trash cans, including plastic waste receptacle were used for oily rags. Cite: SOLAS (1997) II-2/Reg 18.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 1 September 2023
Resolution: Finding # 1245.0 issued by ABS Jacksonville.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 23 August 2023 Resolved
Medical waivers may be granted with specific conditions to which the applicant must adhere, such as more frequent monitoring of the medical conditions, submission of medical exams and/or tests at varying intervals to track the ongoing status of the medical condition, or operational limitations in the manner the mariner may serve under the MMC. • 03 crew members were missing medical certificate waivers. • Current steward med certificate indicated not fit for food handling. Steward recently received new medical certificate and provided documentation supporting no medical issues. Provide supporting documentation from NMC of updated medical certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 22 September 2023
Resolution: The crewmembers with missing medical waivers were located for two crew members 2AE and 3AE) and two crew members departed (MED and STU).
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 17 August 2023 Resolved
The training manual…shall contain instructions and information, in easily understood term illustrated wherever possible, on the lifesaving appliances provided in the ship and ton the best methos of survival. The immersion suits found in the SOLAS training manual were for a different model than crew had on board. Cite: SOLAS (2020) III/Reg 35.3
Action required: 10 - Deficiency Rectified
Resolved 18 August 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 August 2023 Resolved
Two means of escape shall be provided from each machinery space of category A. A box was stored in emergency escape ladder. Cite: SOLAS (1997) II-2/Reg 45
Action required: 10 - Deficiency Rectified
Resolved 18 August 2023
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 26 August 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. There is a steady drip of hydraulic oil from a linkage between the pump motors on the tank top.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 13 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 August 2021 Resolved
The following fire protection systems shall be kept in good order so as to endure their required performance if a fire occurs: structural fire protection including fire resisting divisions, and protection of openings and penetrations in these divisions. A rock block type multi-cable transit installation in the steering gear room is not installed correctly, pieces are protruding or recessed and should be installed as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 13 October 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 August 2021 Resolved
Doors provided to ensure the watertight integrity of internal openings which are used while at sea are to be sliding watertight doors capable of being remotely closed from the bridge and are also to be operable locally from each side of the bulkhead. The WTD on winch room fwd bulkhead has a faulty power switch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 13 October 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 August 2021 Resolved
Power control systems shall close doors at an approximate uniform rate of closure, but in no case shall the closure time, from the time a door begins to move to the time it reaches the fully closed position, be less than 20 s or more than 40 s. Vsl's Class 3 WTDs reached complete closure after 1 minute.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 13 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2021 Resolved
Maintenance of conditions after survey. On 3/2/2021 at approximately 2330 Sector Virginia Command Center received a report of a fire in the starboard thruster room that occurred at 2130 in the brake band of the starboard thruster. 74 SOLAS (14) I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 4 March 2021
Resolution: ABS provided class report
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 26 August 2019 Resolved
Vessel has posted through-out the ship Fire Control Plans (FCP) that are Revision "A". The most current revision on the bridge is Revision "D". Plans shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. The total number of FCPs on-board shall be the amount as indicated on the FCP Revision "D".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 29 August 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 August 2019 Resolved
The Recognized Organization is in the process of issuing certificates; the certificates issued shall be readily available on board for examination. The RO shall emails electronic copies to USCG before departure CLEARED
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2019
Resolved 26 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 August 2019 Resolved
The following fire doors are not closing on their own: laundry room doors / door leading into draft room from main lab: fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 26 August 2019
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 26 August 2019 Resolved
The following flood/over the side lights need to be properly mounted; starboard bridge wing light is secured with a line, port side at bottom of ladder light is just laying on the deck; electrical apparatus shall be installed as not to cause injury when handled or touched in the normal manner
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 26 August 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 August 2019 Resolved
Make repairs to the small oil leak on the #1 ship service diesel generator turbo flange. Means shall be provided to control leaks of flammable liquids; The arrangements of distribution and utilization of oils shall be such as to ensure the safety of the ship and persons on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 26 August 2019
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 May 2019 Resolved
The port outboard steering pump is acting and making a abnormally loud noise,the pump needs to be investigate /trouble shoot to see the cause of the noise and make repairs as needed. The ships equipment shall be maintained to conform with the present regulations to ensure that the ship may fit to proceed to sea.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2019
Resolved 26 August 2019
Navigation › Collision/Grounding Avoidance › Radar
Issued 26 August 2014 Resolved
Prove operation of all radars for class surveyor.
Action required: 705 - Other - as specified
Resolved 28 August 2014
Lifesaving › Lifebuoys › Serviceable
Issued 26 August 2014 Resolved
Replace plugs in life rings as marked.
Action required: 705 - Other - as specified
Resolved 28 August 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 August 2014 Resolved
Repalce lifering light on port side 02 deck.
Action required: 705 - Other - as specified
Resolved 28 August 2014
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 June 2012 Resolved
OWS inop at time of inspection due to failed part; Tech rep repaired prior to vessel sailing.
Condition: Improper/Lack of Maintenance
Due 28 July 2012
Resolved 27 July 2012
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 October 2008 Resolved
Proved proof of the OWS content meter being reinstalled and a operational test conducted.
Condition: Unknown
Due 31 October 2008
Resolved 3 November 2008
Resolution: Email received 05Dec2008 from [name withheld] advising done.
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 October 2008 Resolved
All vent closures are to be renewed or repair to be effectively functional.
Condition: Improper/Lack of Maintenance
Due 28 December 2008
Resolved 30 November 2008
Resolution: Email received 05Dec2008 from [name withheld] advise done.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 9 October 2008 Resolved
Proved proof of required equipment to conduct to High Oil temp test as described in the Coast Guard approved Test procedure is onboard.
Condition: Improper/Lack of Maintenance
Due 28 November 2008
Resolved 3 November 2008
Resolution: Email received 05Dec2008 from [name withheld] advise done.
Communications › Alarms/Indicators › High Water Alarm
Issued 9 October 2008 Resolved
. Proved proof of required equipment to conduct to High Jacket water a test as described in the Coast Guard approved Test procedure is onboard.
Condition: Unknown
Due 28 November 2008
Resolved 3 November 2008
Resolution: Email received 05Dec2008 from [name withheld] advise done.
Lifesaving › Launching Appliances › Falls
Issued 9 October 2008 Resolved
Conduct weight test after falls have been renewed.
Condition: Unknown
Due 28 October 2008
Resolved 28 October 2008
Resolution: Weight test Conduct, Sat.
Lifesaving › Lifeboat › Exhaust Pipe
Issued 27 September 2005 Resolved
Repair engines on both Lifeboats to prevent iol discharge through exhaust.
Action required: 705 - Other - as specified
Due 27 October 2005
Resolved 14 November 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 September 2005 Resolved
Repair Lifeboat embarkation light located on port side aft.
Action required: 705 - Other - as specified
Due 27 October 2005
Resolved 14 November 2005
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Foam Generator
Issued 27 September 2005 Resolved
Provide copy of firefighting foam analysis report.
Action required: 705 - Other - as specified
Due 27 October 2005
Resolved 14 November 2005
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 27 September 2005 Resolved
Repair and prove proper operation of ARPA.
Action required: 705 - Other - as specified
Due 27 October 2005
Resolved 14 November 2005
Construction/Loadline › Structures › Door
Issued 27 September 2005 Resolved
Repair and prove proper operation of "Master mode switch" so that all power operated watertight doors close simultaneously.
Action required: 705 - Other - as specified
Due 27 October 2005
Resolved 14 November 2005
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 27 September 2005 Resolved
Renew wire & plug for security light located on starboard side.
Action required: 705 - Other - as specified
Due 27 October 2005
Resolved 14 November 2005
Electrical › Electric Generation Source (emergency) › Switch
Issued 27 September 2005 Resolved
Label emer. generator shut-off switch on deck.
Action required: 705 - Other - as specified
Due 27 October 2005
Resolved 14 November 2005
Engineering › Bilge Water Management System › Manifold
Issued 27 September 2005 Resolved
Label forward bilge manifold.
Action required: 705 - Other - as specified
Due 27 October 2005
Resolved 14 November 2005
Lifesaving › Lifebuoys
Issued 7 November 2001 Resolved
Port/Stbd ring buoys not approved type.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Resolution: Replaced with approved ring buoys
Lifesaving › Lifeboat Equipment
Issued 7 November 2001 Resolved
Numerous water bags in both P/S lifeboats not approved type
Condition: Placed in Improper Service
Due 7 November 2001
Resolved 7 November 2001
Resolution: Replaced water bags with approved type
Lifesaving › Lifeboat
Issued 7 November 2001 Resolved
Retro-reflective tape missing from bottom side of both P/S lifeboats
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Resolution: replaced
Accommodation/Occupational Safety › Ventilation
Issued 7 November 2001 Resolved
Overhead fans in accomodation space missing protective guard LEGACY COMPONENT DESC: fan
Condition: Improper/Lack of Maintenance
Due 7 November 2001
Resolved 7 November 2001
Resolution: Replaced
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 7 November 2001 Resolved
Protective light globe cage missing on overhead light in freezer LEGACY COMPONENT DESC: LIGHT COVER
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Resolution: Replaced
Accommodation/Occupational Safety › Occupational Safety
Issued 7 November 2001 Resolved
Lable emergency escape areas in MSD space LEGACY COMPONENT DESC: Markings
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Resolution: Labled
Accommodation/Occupational Safety › Occupational Safety
Issued 7 November 2001 Resolved
Lable stove disconnect at distribution panel in galley LEGACY COMPONENT DESC: Markings
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Resolution: Labled
Accommodation/Occupational Safety › Occupational Safety
Issued 7 November 2001 Resolved
General alarm bell and fire alarm bell are mislabled LEGACY COMPONENT DESC: Lable
Condition: Improper Installation
Due 7 November 2001
Resolved 7 November 2001
Resolution: Corrected
Navigation
Issued 14 April 2001 Resolved
Provide corrected plans to indicate approved horizontal spacing in accordance with CCGD7(m) ltr 16703, dtd Apr 19, 2001.
Condition: Unknown
Due 19 July 2001
Resolved 31 January 2002
Resolution: Received revised nav. light drawings.
Navigation
Issued 15 September 2000 Resolved
Repair Stbd steering azimuth motor and bull gear for LIPPS Z drive system at next yard period but no later than 15OCT00.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Engineering
Issued 13 October 1999 Resolved
Provide heat shield bowls to rayco filters to EMD engines._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 November 1999
Resolved 2 November 1999
Fire Fighting
Issued 13 October 1999 Resolved
Provide Unitor service report to MSO San Juan._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 November 1999
Resolved 2 November 1999
Lifesaving
Issued 29 October 1998 Resolved
HYDROSTATICALLY TEST ALL OVERDUE SCBA AIR BOTTLES AT AN APPROVED U.S. DOT FACILITY.
Condition: Unknown
Due 29 October 1998
Resolved 29 October 1998
Engineering
Issued 29 October 1998 Resolved
PROVIDE TWO SHIPS SERVICE AIR RECIEVER AND ONE SHIPS WHISTLE AIR RECIEVER RELIEF VALVES WITH HAND RELIEVING GEAR.
Condition: Unknown
Due 29 October 1998
Resolved 29 October 1998
Documentation
Issued 13 December 1997 Resolved
PROVIDE STCW DOCUMENTATION FOR THE CHIEF MATE PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Electrical
Issued 13 December 1997 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY DIESEL GENERATOR AUTOMATIC TRANSFER. THIS REQUIREMENT MUST BE COMPLETED TO THE SATISFACTION OF THE ATTENDING CG OR ABS SURVEYOR PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Fire Fighting
Issued 13 December 1997 Resolved
PROVIDE TEST RESULTS OF THE FOAM ANALYSIS REPORT (SAMPLE TAKEN BY HILLER REP.).
Condition: Unknown
Due 6 January 1998
Resolved 6 January 1998
Documentation
Issued 13 December 1997 Resolved
PROPERLY LABEL THE LOADLINE HULL MARKINGS IN ACCORDANCE WITH ABS LOADLINE CERTIFICATE DATED 13 MAY 1997.
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Electrical
Issued 13 December 1997 Resolved
PROPERLY INSTALL STUFFING BOX WITH APPROVED MATERIAL AT BULKHEAD 1-120-0.
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Lifesaving
Issued 13 December 1997 Resolved
END-FOR-END THE FALLS IN WAY OF LIFEBOATS ONE AND TWO AND PERFORM WEIGHT TEST AND RELEASING GEAR TEST TO THE SATISFACTION OF THE ATTENDING CG OR ABSSURVEYOR.
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Construction/Loadline
Issued 6 November 1996 Resolved
Provide statement form Master that a new oil content meter has been installed on OWS and tested statifactorily.
Condition: Unknown
Due 6 November 1996
Resolved 6 November 1996
Electrical
Issued 6 November 1996 Resolved
Provide manufacturer's technical specifications indicating that shallac wood is authorized for use as structural support in the Interphase reactor.
Condition: Unknown
Due 6 November 1996
Resolved 6 November 1996
Construction/Loadline
Issued 6 November 1996 Resolved
Renew leaking hydraulic hose on hydraulicly controled WTD 2-120-1 in way ofthe winch room.
Condition: Unknown
Due 6 January 1997
Resolved 3 December 1996
Lifesaving
Issued 6 November 1996 Resolved
Provide statement from Master that remote launching device for STBD lifeboat has been renewed and tested statisfactorily.
Condition: Unknown
Due 6 November 1996
Resolved 20 November 1996
Engineering
Issued 6 November 1996 Resolved
Provide statement from Master indicating that the low oil shutdown system for the #2Main Generator has been tested satisfactorly.
Condition: Unknown
Due 6 January 1997
Resolved 3 December 1996
Electrical
Issued 6 November 1996 Resolved
Provide statement from Master indicating that the reverse power relays on all generators have been tested satisfactorily.
Condition: Unknown
Due 6 January 1997
Resolved 3 December 1996
Engineering
Issued 22 March 1996 Resolved
MAKE THE SHIPS WHISTLE AIR RECEIVER AVAILABLE FOR AN INTERNAL INSPECTION ORHYDRO TO 1 1/4 TIMES MAWP.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Fire Fighting
Issued 22 March 1996 Resolved
INSTALL INSTRUCTIONS/SCHEMATIC FOR BOW THRUSTER CO2 INSTALLATION IN ACCORDANCE WITH 46 CFR 193.15-10(A).
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Fire Fighting
Issued 22 March 1996 Resolved
SUPPLY APPROVED PLANS FOR THE BOW THRUSTER CO2 INSTALLATION IN ACCORDANCE WITH 46 CFR 189.20-10.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Accommodation/Occupational Safety
Issued 22 March 1996 Resolved
PROVIDE EMBARKATION LADDERS FOR THE PORT AND STARBOARD LIFEBOATS IN ACCORDANCE WITH 46 CFR 192.50-5.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Construction/Loadline
Issued 22 March 1996 Resolved
PROVIDE PLANS TO THE MARINE SAFETY CENTER FOR ALTERATIONS IN THE SALT WATERCOOLING LINES PENETRATING FUEL OIL TANKS IN ACCORDANCE WITH 46 CFR 189.45- 1.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Lifesaving
Issued 22 March 1996 Resolved
PROVE PROPER OPERATON OF THE RELEASING GEAR IN THE PORT LIFEBOAT.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Fire Fighting
Issued 22 March 1996 Resolved
UPDATE VESSEL FIRE CONTROL PLANS TO REFLECT BOW THRUSTER CO2 INSTALLATION.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Accommodation/Occupational Safety
Issued 22 March 1996 Resolved
PROVIDE EMBARKATION LADDERS FOR THE PORT AAND STARBOARD LIFERAFTS IN ACCORDANCE WITH 46 CFR 192.50-7.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Engineering
Issued 25 August 1995 Resolved
LIMIT VESSEL OPERATION TO THE PROPULSION SYSTEM PARAMETERS ESTABLISHED IN [name withheld] LETTER SER: CU-9/656 DATED 23AUG95.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Engineering
Issued 25 August 1995 Resolved
PROVIDE FULLY FUNCTIONAL AND SATISFACTORILY TESTED PORT AND STBD PHASE_x001C_ SHIFT TRANSFORMERS TO FURNISH FULL PROPULSION SYSTEM CAPABILITIES AS ORIGINALLY INTENDED.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Electrical
Issued 25 August 1995 Resolved
PROVIDE COMPLETE PROTECTIVE DEVICE COORDINATION STUDY FOR THE ELECTRICAL PROPULSION SYSTEM INCLUDING CIRCUIT BREAKER CURVES, SHORT CIRCUIT CURRENT AVAILABLE GRAPHS AND RELATED INTERRELATIONSHIPS. THIS INFORMATION MUST BE PROVIDED TO THE USCG MARINE SAFETY CENTER FOR REVIEW AND ACCEPTANCE.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Engineering
Issued 25 August 1995 Resolved
THE PHASE SHIFT TRANSFORMERS NOTED IN ITEM #1 SHALL BE PROVIDED WITH ENCLOSURES OF A MARINE TYPE DRIP PROOF DESIGN FOLLOWING ACCEPTED GOOD MARINE PRACTICES.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Engineering
Issued 19 June 1995 Resolved
PRIOR TO DEPARTING THE PORT OF PASCAGOULA THE CAUSE OF THE CASUALTY OF THE PORT PHASE SHIFT TRANSFROMER MUST BE FULLY RESOLVED TO THE SATISFACTION OF THE COGNIZANT [name withheld] ARE AUTHORIZED.
Condition: Unknown
Due 19 June 1995
Resolved 19 June 1995
Navigation
Issued 5 December 1994 Resolved
PROVE FUSE RATING OF LIPPS CONTROLS AT MCC.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Engineering
Issued 5 December 1994 Resolved
COMPLETE DEMONSTRATION OF DESIGN VERIFICATION WHEN APPROVED.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Engineering
Issued 5 December 1994 Resolved
COMPLETE DEMONSTRATION OF PERIODIC TEST PROCEDURE WHEN APPROVED AND PRIOR TO DEPARTING THE PORT OF PASCAGOULA, MISSISSIPPI.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Navigation
Issued 5 December 1994 Resolved
PROVIDE MANUVERING DATA IN WHEELHOUSE.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Fire Fighting
Issued 5 December 1994 Resolved
FIRE AND BOAT DRILLS MUST BE CONDUCTED WHEN THE CREW IS ON BOARD PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Fire Fighting
Issued 5 December 1994 Resolved
POST STATION BILL PRIOR TO CONDUCTING USCG WITNESSED DRILLS.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995

Ownership record