Records from 1981 to 1996. Most recent: inspection, 29 October 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
29 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 42403
24 September 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 22672
9 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878925
15 August 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 182289
7 June 1994
Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 827066
6 June 1994
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1012975
31 May 1994
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1463828
28 January 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1162254
19 July 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 224244
29 May 1992
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1257539
22 April 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1254917
12 December 1991
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 946273
25 May 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1323421
26 June 1990
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 901477
27 May 1990
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 926539
25 October 1989
Deadweight Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1210273
10 August 1989
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1040083
26 May 1989
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1038201
15 May 1989
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1206552
12 April 1989
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1206295
25 January 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1040579
28 May 1988
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 886583
28 May 1988
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1193858
8 April 1988
Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1352714
4 June 1987
Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1006630
29 May 1987
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1333931
30 May 1986
Deficiency Check · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 989432
25 May 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1295475
10 August 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1281854
2 June 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 973664
3 June 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 968987
5 June 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 963631
6 June 1981
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1277104
Electrical
Issued 31 May 1994
Resolved
PROVE PROPER OPERATION OF #2 SSTG, REVERSE POWER RELAY, AND OVERSPEED TRIP_x001C_PRIOR TO COMMENCING SUMMER CRUISE.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994
Documentation
Issued 26 May 1989
Resolved
RESUBMIT REVISED STABILITY BOOKLET TO COMMANDANT, MARINE SAFETY CENTER, INCLUDING FUEL OIL STORAGE TANK INSTALLATION FOR APPROVAL.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Navigation
Issued 26 May 1989
Resolved
MAKE REPAIRS AND PROVE PROPER OPERATION OF THE 3CM RADAR.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Construction/Loadline
Issued 29 May 1987
Resolved
MAKE PERM.REPAIRS TO THE DRAINS @ THE EVAPORATOR FLAT TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE NLT 28JUN87
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Construction/Loadline
Issued 30 May 1986
Resolved
MAKE REPAIRS TO #8 SLIDING WATERTIGHT DOOR DISENGAGING CLUTCH TO DISENGAGE HAND WHEELS DURING AUTOMATIC OPERATION.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Construction/Loadline
Issued 30 May 1986
Resolved
MAKE REPAIRS TO REMOVE OPEN/CLOSE INDICATORS FOR SLIDING WATER TIGHT DOORS #5,7 AND 8.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Accommodation/Occupational Safety
Issued 25 May 1985
Resolved
REPAIR TO PROPER WORKING CONDITION THE VENTILATION IN THE AFT COMMUNITY HEADS.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Construction/Loadline
Issued 25 May 1985
Resolved
RENEW AS ORIGINAL THE JOINER BULKHEAD INBOARD OF ROOM #227.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Engineering
Issued 25 May 1985
Resolved
CONDUCT A 1.5 MAWP HYDRO OF ALL OIL TRANSFER PIPING.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Fire Fighting
Issued 25 May 1985
Resolved
INSTALL A FIXED CO2 FIRE FIGHTING SYSTEM ON THE FWD JPAINT LOCKER.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Engineering
Issued 25 May 1985
Resolved
MAKE BOILER AVAILABLE FOR A WATERSIDE INSPECTION.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Accommodation/Occupational Safety
Issued 25 May 1985
Resolved
MAKE PRESSURE VESSELS AVAILABLE FOR AN INTERNAL EXAMINATION.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Lifesaving
Issued 25 May 1985
Resolved
INSTALL LIMIT SWITCHES ON BOAT DAVITS SWITCHES #1 AND #2.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Engineering
Issued 25 May 1985
Resolved
MAKE BOILER MOUNTS AVAILABLE FOR INTERNAL INSPECTIONS BEFORE THE VESSEL SAILS AGAIN, BUT NOT LATER THAN 01MAY86.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Construction/Loadline
Issued 25 May 1985
Resolved
MAKE PERMANENT REPAIRS TO THE BRIG PORTLIGHT GLASS.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Construction/Loadline
Issued 25 May 1985
Resolved
MAKE PORT AND STARBOARD QUARTER DECK SIDE PORT DOORS WEATHERTIGHT. THE ABOVE TO BE DONE PRIOR TO SUMMER CRUISE 1986 BUT NO LATER THAN 01MAY86.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Lifesaving
Issued 2 June 1984
Resolved
REPLACE THE HOIST SWITCHES TO THE #3, #4 AND #5 LIFEBOAT WINCHES
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Fire Fighting
Issued 2 June 1984
Resolved
HYDROSTATICALLY TEST ALL PORTABLE FIRE EXTINGUISHERS THAT HAVE NOT BEEN TESTED FOR THE LAST THREE (3) YEARS
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Fire Fighting
Issued 2 June 1984
Resolved
TEST THE GALLEY RANGE FIRE HOOD FOR PROPER OPERATION.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Electrical
Issued 2 June 1984
Resolved
REMOVE ALL JURY RIG WIRING FROM THE ENGIEROOM, PROPERLY SECURE ALL DEAD ENDED CABLES.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Electrical
Issued 2 June 1984
Resolved
REMOVE ALL ITEMS STORED INMOTOR CONTROLLER BOXES, STOW PROPERLY.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Electrical
Issued 2 June 1984
Resolved
PROPERLY STENCIL ALL EMERGENCY LIGHTS.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Electrical
Issued 2 June 1984
Resolved
REPLACE ALL BURNT OUT LIGHT BULBS.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Fire Fighting
Issued 2 June 1984
Resolved
TEST THE ZONE 1 FIRE SENSOR FOR PROPER OPERATION.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Fire Fighting
Issued 2 June 1984
Resolved
REPAIR TO PROPER WORKING CONDITON 2 STBD MAIN DECK AFT MAIN HOUSE FIRE SCREEN DOORS, AND FSD # A-3 AND #P-4
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Construction/Loadline
Issued 2 June 1984
Resolved
REPAIR THE FOREPEAK HATCH KNIFE EDGE AND REPLACE THE GASKET.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Construction/Loadline
Issued 2 June 1984
Resolved
REPAIR THE FWD PORT AFTR HOUSE, FWD WATERTIGHT DOOR TO PROPER WORKING CONDITION.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Construction/Loadline
Issued 2 June 1984
Resolved
REPLACE THE GASKET TO THE PORT FWD MAIN HOUSE MAIN DECK WTD.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Construction/Loadline
Issued 2 June 1984
Resolved
REPLACE THE PORTABLE GLASS TO THE PORTHOLES STBD MAIN MESS DECK, AND CARPENTER SHOP.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Electrical
Issued 2 June 1984
Resolved
INSTALL FLOODLIGHTS FOR NIGHT LIFEBOAT OPERATIONS ON THE LIFEBOAT AND EMBARKCATION DECKS.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Fire Fighting
Issued 2 June 1984
Resolved
REPLACE THE FIRELINE GASKET AT STATION #9.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Construction/Loadline
Issued 2 June 1984
Resolved
REPLACE THE PRIMING LINE TO THE BALLAST PUMP.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Electrical
Issued 2 June 1984
Resolved
REPLACE THE PROTECTIVE WIRE CAGE TO THE SANITARY PUMP MOTOR.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Engineering
Issued 2 June 1984
Resolved
CALIBRATE ALL ENGINE ROOM GAUGES NOT CLIBRATED IN THE LAST TWELVE (12) MONTHS.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Fire Fighting
Issued 2 June 1984
Resolved
PLACE PROTECTIVE SCREWS OR PANELS OVER ALL FUSE PANELS IN THE ENGINEROOM AND EMERGENCY DIESEL ROOM.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Electrical
Issued 2 June 1984
Resolved
REPALCE THE PLEXIGLASS INSPECTION COVERS TO ALL MOTORS.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Engineering
Issued 2 June 1984
Resolved
LABEL ALL GAUGES AND VALVES LEGIBLY.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Engineering
Issued 2 June 1984
Resolved
REPLACE THE GLASS BROKEN ON GAUGE FACES.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984
Electrical
Issued 2 June 1984
Resolved
PLACE LEGIBLE WIRING DIAGRAMS IN ALL MOTOR CONTROLLERS.
Condition: Unknown
Due 2 June 1984
Resolved 2 June 1984