MAURY USCG vessel records
← All vessels

GULF RAIN

GULF RAIN is a 1993 freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in March 2018, along with 13 deficiencies and 3 operational controls.

Records from 2016 to 2018. Most recent: inspection, 28 March 2018.

Built
1993
Last inspected
28 March 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9056052
410992
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-410992

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it2514 - Displacement, Metric Ton
1351 - Convention (Subpart B), Net Ton
2514 - Convention (Subpart B), Gross Ton
3560 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 8

28 March 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6376507
7 September 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6260726
2 September 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam · COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6251225
19 May 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6150161
19 May 2017 In-Service Inspection · Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6150265
7 April 2017 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6119725
21 February 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6092081
17 May 2016 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5876153

Deficiency record · 13

Communications › Visual Communication › Signalling Lamp
Issued 28 March 2018 Resolved
All ships of 150 gross tonnnage and upwards must be fitted with a daylight signalling lamp, or other means to communicate by light during day and night using an energy source of electrical power not solely dependent on the ships power supply. Vessel did not have an alternate source of power for daylight signalling lamp. 74 SOLAS (2014) Ch.V/ Reg. 2.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2018
Resolved 9 April 2018
Resolution: Received satisfactory report and verified the deficiency was corrected.
Construction/Loadline › Hull › Bracket
Issued 2 September 2017 Resolved
0938: PSCO noted damage to the bow including tripped framing and brackets, cracked welds and hull plating. 74SOLAS(14)1/11
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 28 March 2018
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 2 September 2017 Resolved
1499: PSCO noted that the starter leaked oil. 74SOLAS(97)II-2/15.2.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2017
Resolution: PSCO verified and received a class report from DNV-GL attesting to proper repairs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 September 2017 Resolved
0999: PSCO noted dead ended wires coming out of port bulkhead and overhead of the bridge. 74SOLAS(04) II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2017
Resolution: PSCO verified and received a class report from DNV-GL attesting to proper repairs.
Lifesaving › Immersion Suits › General
Issued 2 September 2017 Resolved
0663: PSCO noted that there are no immersion suits on bridge or in ECR. 74SOLAS(14)III/32.3.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 September 2017
Resolution: One immersion suit was placed on the bridge and in the ECR
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 2 September 2017 Resolved
0999: PSCO noted that the fire control plan was out of date. 74SOLAS(14) II-2/15.2.4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2017
Resolution: PSCO verified and received a class report from DNV-GL attesting to proper repairs.
Construction/Loadline › Penetrations › Pipe Flange
Issued 2 September 2017 Resolved
1299: PSCO noted that cable penetration in the aft bulkhead of bridge is not weathertight. ICLL 66 Article 15
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2017
Resolution: PSCO verified and received a class report from DNV-GL attesting to proper repairs.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 September 2017 Resolved
1299: PSCO noted chain in openings along periphery had opening larger than 230mm at bottom.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2017
Resolution: PSCO verified and received a class report from DNV-GL attesting to proper repairs.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 2 September 2017 Resolved
0999: PSCO noted transfer procedures not in compliance.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 October 2017
Resolved 28 March 2018
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 19 May 2017 Resolved
Whenever an accident occurs to a ship or a defect is discovered, the master shall report to the Administration or recognized organization responsible for issuing the relevant certificate, who shall cause investigations to be initated to determine whether a survey is necessary. The master has not notified the Flag State nor the local port State. 17bc
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2017
Resolved 21 May 2017
Resolution: Report from flag was provided, and verified by [name withheld], USCG.
Engineering › Thrusters › Motor
Issued 19 May 2017 Resolved
Following pier allision... Bow thruster remains inooperable. Vessel required to have tug assistance, of sufficient size and horsepower to the satisfaction of the pilot, for all ports within the Captain of the Port San [name withheld] until bow thruster is repaired and fully functional. To remove these restrictions, this office must receive and accept a report from the vessel's classif
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 11 September 2017
Resolution: Received Class Report attesting to the repairs made to ship;s bow thruster.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 May 2016 Resolved
Cargo and other hatchways construction shall provide the means for securing the weathertightness of cargo. Port State Control examiners observed deteriorated rubber gasket for forward hatch covers. ICLL 2005 Annex I Reg 14 Action 50.b
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 22 February 2017
Resolution: DNV-GL class surveyor verified a new rubber gasket was fitted to forward hatch covers. Deficiency rectified.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 17 May 2016 Resolved
The condition of the ship shall be maintained to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Port State Control examiners observed the starboard side anchor chain showing major signs of corrosion and wastage. SOLAS 2004 Chap. 1 Reg 11(a) Action 50.b
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 22 February 2017
Resolution: Condition of class was issued for new certified anchor chain. DNV-GL class surveyor verified and deficiency was rectified. See survey report (Activity No. 6092081)

Ownership record