Records from 1994 to 2022. Most recent: inspection, 8 February 2022.
Documentation record
Registered dimensions (L × B × D)131.5 ft × 28.0 ft × 10.5 ft
Registered tonnagegross 89 / net 68
ITC dimensions (L × B × D)131.5 ft × 28.0 ft × 10.5 ft
ITC tonnagegross 249 / net 74
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1994
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Regulatory (Subpart C or D), Net Ton
74 - Convention (Subpart B), Net Ton
89 - Regulatory (Subpart C or D), Gross Ton
249 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 50
8 February 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7392451
19 July 2021
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7260787
11 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110359
24 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7014832
10 July 2019
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6744399
19 April 2019
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6665896
9 April 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6674539
4 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6405497
25 September 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6274273
15 May 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6147001
6 October 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6021694
24 March 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5839509
24 September 2015
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5718047
21 October 2014
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5010148
27 June 2014
COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4901906
12 March 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4815400
19 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4227958
22 September 2011
Re-Inspection · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4152493
10 September 2010
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3846327
22 April 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3458145
20 March 2008
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3168031
17 April 2007
Hull Examination · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2909269
9 April 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2904160
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806441
24 April 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2629460
16 March 2005
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2309931
20 May 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2073329
19 February 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2016406
19 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1759483
5 March 2003
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1752851
29 July 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1653901
25 October 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384905
27 July 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389148
31 January 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 768411
26 January 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 196321
3 August 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458662
19 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 118099
17 July 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436105
4 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776703
6 August 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425947
2 July 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 64718
3 October 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764517
21 September 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 169166
21 September 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 196341
3 August 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459257
12 September 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405777
28 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 493681
21 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 482470
15 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1173010
15 September 1994
Hull Examination · Initial Certification · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396193
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 July 2019
Resolved
Vessel #5 MDE had fuel leak along injector. Service engine to correct fuel leak prior to operation of #5 MDE.
46CFR176.25-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 11 July 2019
Resolution: Rectified to the satisfaction of Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 July 2019
Resolved
Vessel #2 and #4 MDE's J/W piping leaking or cracked, and #3 MDE R/W piping was temporarily patched. Service J/W and R/W piping systems and provide permanent repairs in kind.
46CFR176.25-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 11 July 2019
Resolution: Rectified to the satisfaction of Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 July 2019
Resolved
Vessel starboard generator missing guard over rotating pully. Ensure guard is placed over hazardous rotating machinery.
46CFR176.25-107(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 11 July 2019
Resolution: Rectified to the satisfaction of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 July 2019
Resolved
Ring buoys did not have vessel name. All buoys shall be marked with vessel name.
46CFR185.30-5(c)
Action required: 10 - Deficiency Rectified
Due 10 July 2019
Resolved 10 July 2019
Resolution: Rectified to the satisfaction of Marine Inspector.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 10 September 2010
Resolved
RANGE SHUTOFF NOT READILY VISIBLE FROM RANGE AND ONE CREWMEMBER DID NOT KNOW LOCATION. INSTALL/PROVIDE RANGE SHUT-OFF PLAQUARD/MARKING.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 September 2010
Resolved 10 September 2010
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 10 September 2010
Resolved
EMERGENCY LIGHT LEADING FROM FORWARD ENGINE ROOM EXIT NEEDS TO BE INSTALLED.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 September 2010
Resolved 10 September 2010
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 10 September 2010
Resolved
RESCUE PLATFORM COULD NOT BE SECURED TO THE VESSEL AND CURRENT ARRANGEMENT MAKES IT UNSTABLE. PROVIDE/INSTALL MEANS TO SECURE RESCUE PLATFORM TO VSL.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 September 2010
Resolved 10 September 2010
Electrical › Electric Generation Source (service)
Issued 5 March 2003
Resolved
Both ship service generators were missing or had unreadable manufacturer data plates as required by 46 CFR 183.10-5. Issued 835 stating the need for vessel rep to provide required data plates with all pertinent information as per regulations. LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 14 April 2003
Resolved 18 March 2003
Resolution: Vessel rep acquired and provided manufacturer data plates. Data plates will be affixed to both ssg''s.