MAURY USCG vessel records
← All vessels

DANCER

DANCER is a 1968 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2016, most recently in October 2019, along with 14 deficiencies.

Records from 2016 to 2019. Most recent: inspection, 24 October 2019.

Built
1968
Last inspected
24 October 2019
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 October 2019
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ2208
411158
Flag
UNITED STATES
Maury page id
psix-411158

Documentation record

Registered dimensions (L × B × D)37.0 ft × 12.0 ft × 6.0 ft
Registered tonnagegross 17 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPOST MARINE CO., INC. · MAYS LANDING, NJ, UNITED STATES · built 1968
Hull materialWood
PropulsionGasoline Inboard
Hull shapeShip
Hull configurationMonohull
Hailing portGALESVILLE, MD
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

24 October 2019 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6839318
11 April 2019 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6663288
25 March 2019 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6648347
24 January 2019 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6615760
22 January 2019 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6663733
11 April 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6390007
9 April 2018 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6388073
27 November 2017 Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6320962
27 June 2017 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6188398
26 September 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6009669

Deficiency record · 14

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 January 2019 Resolved
Provide this office with a repair proposal for Cabin area restoration - POST fire damage. Repair proposal should include materials list; and material list should identify all marine-grade and fire-rated specific materials (ex. marine-grade plywood, fire-rated floor coverings).
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2019
Resolved 25 March 2019
Resolution: Verified and approve the Repair Proposal submitted by the vessel owner. Verified that the material was of marine-grade specifications, ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 January 2019 Resolved
Renew the portable fire extinguisher that was damaged during the recent fire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2019
Resolved 11 April 2019
Resolution: Verified renewed portable fire extinguisher, ALL SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 January 2019 Resolved
Renew portside scupper to its original design and intended functionality. Vessel Owner is utilizing a hard piece of plastic to replace the scupper's flapper device.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2019
Resolved 11 April 2019
Resolution: Verified renewed Portside scupper, ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 January 2019 Resolved
Vessel is required to be dry-dock so that attending Coast Guard Marine Inspectors can inspect the repairs that were performed as a result of the damages that were caused when the vessel hit a log. This incident occurred in mid-October 2018; and the repair process lasted until late December 2018. Throughout this time, the Vessel Owner failed to notify this office of the repairs. This office was not notified of the repairs until January 24, 2019. The Vessel Owner stated that repairs were made to the existing Port & Starboard propellers and a new shaft log and coupler that were installed for the Starboard shaft. Vessel Owner is required to provide documentation attesting to the repairs to the both props and the newly installed Starboard shaft log and coupler.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2019
Resolved 11 April 2019
Resolution: Verified repairs made to the Port and Starboard propellers and the starboard shaft log and coupler, ALL SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019 Resolved
Provide this office with a plan to address the excessive water intrusion that is resulting in auto-bilges pumping water every 15 to 20 minutes. This office has determined this issue to be more than a weepage issue. Plan must include the causative factor as well as corrective action.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2019
Resolved 25 March 2019
Resolution: Verified satisfactory repairs that resulted in water intrusion. Vessel Owner stated that the causative factor was rain water entering into the vessel through poor deck seams on the aft fantail. Vessel Owner used marine-grade sealant to reseal the compromi
Construction/Loadline › Penetrations › Bottom Plug
Issued 27 November 2017 Resolved
Sewage overboard discharge and intake thru-hull valves were not available for inspection. Ensure valves are availabel for inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2018
Resolved 9 April 2018
Resolution: Verified proper operation of overboar sewage valves, ALL SAT.
Construction/Loadline › Penetrations › Bottom Plug
Issued 27 November 2017 Resolved
A/C intake thru-hull valve not available for inspection, Make valve available for inspection or permanently cap thru-hull penetration. 46 CFR 176.610
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2018
Resolved 7 December 2017
Resolution: Vessel owner permanently capped thru-hull and overboard discharge.
Construction/Loadline › Penetrations › Bottom Plug
Issued 27 November 2017 Resolved
STBD raw water valve handle cotter pin assembly broken. Remove old cotter pin and install new assembly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2018
Resolved 7 December 2017
Resolution: Vessel owner replaced valve with new ball valve type.
Construction/Loadline › Penetrations › Bottom Plug Seat
Issued 27 November 2017 Resolved
STBD raw water valve overboard discharge opening worn. Repair/Replace as needed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2018
Resolved 7 December 2017
Resolution: Shipayrd replaced old cock style valve with a new ball valve type. Operated ball valve and it was sat.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 27 November 2017 Resolved
Stbd prop. has small fracture repair or renew propeller.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2018
Resolved 8 December 2017
Resolution: Stbd prop was ground down and cleaned up removing small fracture.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 September 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 4 October 2016
Resolution: Received via email.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 September 2016 Resolved
Provide on board Marine Radio Operator's Permit (MROP)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 24 October 2016
Resolution: Received via email.
Construction/Loadline › Structures › Deck Plating
Issued 26 September 2016 Resolved
Repair aft deck IWO Port Steering compartment opening, wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 7 August 2017
Resolution: Repaired and verified at last inspection.
Lifesaving › Lifebuoys › Serviceable
Issued 26 September 2016 Resolved
Grab lines on Life Ring buoy wasted repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2016
Resolved 4 October 2016
Resolution: Picture received via email.

Ownership record