Records from 1999 to 2019. Most recent: inspection, 24 October 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 29
24 October 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6839318
11 April 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6663288
25 March 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6648347
24 January 2019
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6615760
22 January 2019
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6663733
11 April 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6390007
9 April 2018
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6388073
27 November 2017
Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6320962
27 June 2017
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6188398
26 September 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6009669
14 December 2015
Internal Structural Exam · Drydock Exam · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5781800
29 September 2015
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5803343
3 July 2012
COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4365621
27 September 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4155518
12 September 2011
Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4143824
4 February 2011
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3942982
2 September 2010
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3854243
30 September 2008
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3335887
29 January 2008
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3140095
30 July 2007
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2973331
27 July 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2727756
9 January 2006
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2563596
25 October 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2522576
25 March 2005
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2319578
27 October 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2229613
30 October 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1938939
28 April 2003
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1794771
8 August 2002
Simplified Stability Test · Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1658304
27 May 1999
Uninspected Other
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 879723
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 January 2019
Resolved
Provide this office with a repair proposal for Cabin area restoration - POST fire damage. Repair proposal should include materials list; and material list should identify all marine-grade and fire-rated specific materials (ex. marine-grade plywood, fire-rated floor coverings).
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2019
Resolved 25 March 2019
Resolution: Verified and approve the Repair Proposal submitted by the vessel owner. Verified that the material was of marine-grade specifications, ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 January 2019
Resolved
Renew the portable fire extinguisher that was damaged during the recent fire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2019
Resolved 11 April 2019
Resolution: Verified renewed portable fire extinguisher, ALL SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 January 2019
Resolved
Renew portside scupper to its original design and intended functionality. Vessel Owner is utilizing a hard piece of plastic to replace the scupper's flapper device.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2019
Resolved 11 April 2019
Resolution: Verified renewed Portside scupper, ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 January 2019
Resolved
Vessel is required to be dry-dock so that attending Coast Guard Marine Inspectors can inspect the repairs that were performed as a result of the damages that were caused when the vessel hit a log. This incident occurred in mid-October 2018; and the repair process lasted until late December 2018. Throughout this time, the Vessel Owner failed to notify this office of the repairs. This office was not notified of the repairs until January 24, 2019. The Vessel Owner stated that repairs were made to the existing Port & Starboard propellers and a new shaft log and coupler that were installed for the Starboard shaft. Vessel Owner is required to provide documentation attesting to the repairs to the both props and the newly installed Starboard shaft log and coupler.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2019
Resolved 11 April 2019
Resolution: Verified repairs made to the Port and Starboard propellers and the starboard shaft log and coupler, ALL SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019
Resolved
Provide this office with a plan to address the excessive water intrusion that is resulting in auto-bilges pumping water every 15 to 20 minutes. This office has determined this issue to be more than a weepage issue. Plan must include the causative factor as well as corrective action.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2019
Resolved 25 March 2019
Resolution: Verified satisfactory repairs that resulted in water intrusion. Vessel Owner stated that the causative factor was rain water entering into the vessel through poor deck seams on the aft fantail. Vessel Owner used marine-grade sealant to reseal the compromi
Construction/Loadline › Penetrations › Bottom Plug
Issued 27 November 2017
Resolved
Sewage overboard discharge and intake thru-hull valves were not available for inspection. Ensure valves are availabel for inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2018
Resolved 9 April 2018
Resolution: Verified proper operation of overboar sewage valves, ALL SAT.
Construction/Loadline › Penetrations › Bottom Plug
Issued 27 November 2017
Resolved
A/C intake thru-hull valve not available for inspection, Make valve available for inspection or permanently cap thru-hull penetration. 46 CFR 176.610
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2018
Resolved 7 December 2017
Resolution: Vessel owner permanently capped thru-hull and overboard discharge.
Construction/Loadline › Penetrations › Bottom Plug
Issued 27 November 2017
Resolved
STBD raw water valve handle cotter pin assembly broken. Remove old cotter pin and install new assembly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2018
Resolved 7 December 2017
Resolution: Vessel owner replaced valve with new ball valve type.
Construction/Loadline › Penetrations › Bottom Plug Seat
Issued 27 November 2017
Resolved
STBD raw water valve overboard discharge opening worn. Repair/Replace as needed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2018
Resolved 7 December 2017
Resolution: Shipayrd replaced old cock style valve with a new ball valve type. Operated ball valve and it was sat.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 27 November 2017
Resolved
Stbd prop. has small fracture repair or renew propeller.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2018
Resolved 8 December 2017
Resolution: Stbd prop was ground down and cleaned up removing small fracture.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 September 2016
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 4 October 2016
Resolution: Received via email.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 September 2016
Resolved
Provide on board Marine Radio Operator's Permit (MROP)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 24 October 2016
Resolution: Received via email.
Construction/Loadline › Structures › Deck Plating
Issued 26 September 2016
Resolved
Repair aft deck IWO Port Steering compartment opening, wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 7 August 2017
Resolution: Repaired and verified at last inspection.
Lifesaving › Lifebuoys › Serviceable
Issued 26 September 2016
Resolved
Grab lines on Life Ring buoy wasted repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2016
Resolved 4 October 2016
Resolution: Picture received via email.
Construction/Loadline › Hull › Bottom Plating
Issued 14 December 2015
Resolved
Fasteners pulled on Port & STBD side in way of In/Out Toilet Thru-holes wasted. Removed fasteners forward, Aft, Top & Bottom of area around through-holes until good screws are located. Area includes Port & STBD side from Stem to Amidships through-holes from chine to keel. Approximately 15’ Aft of Stern.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2015
Resolved 21 January 2016
Resolution: Compromised fasteners were replaced/renewed. Additional fasteners were pulled, with no apparent wear or deterioration.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 14 December 2015
Resolved
Provide proof of operation of through hull valve for sewage overboard valve.
Due 28 December 2015
Resolved 7 March 2016
Resolution: Verified proper operation of the sewage overboard through-hole valve.
Engineering › Bilge Water Management System › Valve
Issued 14 December 2015
Resolved
Repair or Replace through-hull valve for bilge on transom.
Due 28 December 2015
Resolved 21 January 2016
Resolution: New through-hull valve for bilge on transom was installed and tested.
Engineering › Diesel Engine (propulsion-electric) › Valve
Issued 14 December 2015
Resolved
Remove sea water inlet "plug" valves for engines to be inspected by attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2015
Resolved 21 January 2016
Resolution: The sea water inlet "plug" valves for engines were removed by vessel owner and inspected by the attending Marine Inspector. ALL SAT
Construction/Loadline › Hull › Hull Plating
Issued 14 December 2015
Resolved
Determine source of stray current in forepeak bilge area and correct.
Due 28 December 2015
Resolved 15 April 2016
Resolution: Received report conducted by shipyard.
Construction/Loadline › Hull › Hull Plating
Issued 14 December 2015
Resolved
Clean up and repair /replace soft wood at centerline on floor frame #3.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2015
Resolved 15 April 2016
Resolution: Examined sisters frames.
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 December 2015
Resolved
Replace wasted/corroded hydraulic lines on steering system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2015
Resolved 26 February 2016
Resolution: New hydraulic hoses were installed on the steering system that meet the requirements of SAE J 1942.
Engineering › Steering Gear System › Linkage
Issued 14 December 2015
Resolved
Replace wasted steering linkage on Port side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2015
Resolved 21 January 2016
Resolution: The wasted steering linkage on Port side has been replaced. All SAT
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 14 December 2015
Resolved
Conduct sea trials to check for leaking once vessel is put back into water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2015
Resolved 15 April 2016
Resolution: Conducted sea trials.
Construction/Loadline › Hull › Stringer
Issued 14 December 2015
Resolved
Replace bolts in vicinity of bilge pumps in frames 4, 7-10. Provide written plan for alternate replacement as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2015
Resolved 7 March 2016
Resolution: Replaced bolts and sistered framing members in the vicinity of bilge pumps in frames 4, 7-10. All repairs were completed IAW the alternate Repair Proposal that was submitted to and approved by this office.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 September 2015
Resolved
Provide valid COD, vessels original owner passed away and left vessel to deckhand. New owner not able to provide valid COD.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2016
Resolution: Attended veseel and cleared above deficiency.
Engineering › Bilge Water Management System › Pump
Issued 29 September 2015
Resolved
Prove proper opertion of fwd and aft bilge pumps. Pumps were not operational at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2016
Resolution: Attended veseel and cleared above deficiency.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 September 2015
Resolved
Prove proper opertion of Port Navigational running light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2016
Resolution: Attended veseel and cleared above deficiency.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 July 2007
Resolved
Life ring line wasted. Replace with approved U/V protected floatable line (60ft).
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2007
Resolved 1 August 2007
Resolution: Attended vessel and examined life line.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 July 2007
Resolved
Life ring line to light missing. Replace with approved U/V protected floatable line, (3-6ft).
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2007
Resolved 1 August 2007
Resolution: Attended vessel and examined new lanyard for life ring buoy.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 30 July 2007
Resolved
Flammable vapor detector system not operating . Repair/replace prior to carrying passengers for hire and prove proper operation prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2007
Resolved 1 August 2007
Resolution: Attended vessel and tested newly installed vapor detection system.
Construction/Loadline › Hull › Transverse Frame
Issued 9 January 2006
Resolved
Submit repair proposal for transverse frame l;ocated in center and Stbd steering compartment. Frame in center compartment wasted. Frame in Stbd compartment holed/wasted with smaller sub-frame wasted. As marked.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2006
Resolved 17 January 2006
Lifesaving › Lifebuoys › Serviceable
Issued 25 October 2005
Resolved
Replace/repair grab lines on both Life buoys.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2005
Resolved 1 November 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 October 2005
Resolved
Repair port running light. Light not operating properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2005
Resolved 1 November 2005
Lifesaving › Hand Flares › Expired
Issued 25 October 2005
Resolved
Replace expired/missing flares, either 3 red hand held or three orange smoke flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2005
Resolved 1 November 2005
Lifesaving › Lifejacket/PFD (Type I)
Issued 30 October 2003
Resolved
Missing 1 adult life jacket. Required to carry 14. Only had 13 on hand at time of inspection. Issued 835. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 14 November 2003
Resolved 24 November 2003
Lifesaving › Hand Flares
Issued 30 October 2003
Resolved
Provide water tight container to store hand flares. LEGACY COMPONENT DESC: Storage
Due 21 November 2003
Resolved 24 November 2003
Engineering › Fuel Oil Service System
Issued 30 October 2003
Resolved
Label Fuel Oil Cut Off Valves. LEGACY COMPONENT DESC: Valve
Due 21 November 2003
Resolved 24 November 2003
Deck/Cargo
Issued 30 October 2003
Resolved
Replace aft port hatch. Wood becoming worn and weak causing hazard when steped upon.
Due 21 November 2003
Resolved 24 November 2003