This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
1046 - Regulatory (Subpart C or D), Net Ton
1046 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-41128
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 33
25 February 1997Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1096677
1 May 1992Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1134360
9 December 1991Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 539087
5 September 1991Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1254039
15 August 1991Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 938034
7 August 1991Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1243701
9 April 1991Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 931800
5 April 1991COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231073
22 May 1990Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223709
17 October 1989Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043084
5 April 1989Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 896192
5 April 1989COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343364
10 June 1988Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 471560
Unload present cargo prior to leaving Port Arthur, Texas. Make permanent repairs to damaged sideshell, deck plating & assoc internal framing at no 3stbd cargo tank prior to loading next cargo.
Condition: Unknown
Due 7 August 1991
Resolved 7 August 1991
Deck/Cargo
Issued 5 April 1991Resolved
D1. RENEW ALL FLAME SCREENS ON ALL CARGO TANKS. MUST BE COMPLETED PRIOR TOCARRYING CARGO.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Deck/Cargo
Issued 5 April 1991Resolved
D2. PROVIDE ALL P/V VALVES FOR INTERNAL INSPECTION, (FREE-UP ALL WEIGHTS). MUST BE COMPLETED PRIOR TO CARRYING CARGO.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Navigation
Issued 5 April 1991Resolved
D3. PROVIDE APPROVED RUNNING LIGHTS FOR NIGHT TIME OPERATIONS- MUST MEET COLREG OPERATION.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Deck/Cargo
Issued 5 April 1991Resolved
D4. TIGHTEN LOOSE REACH ROD PACKINGS ON MAIN AND STRIPPING LINES FOR ALL TANKS. MUST BE COMPLETED PRIOR TO CARRYING CARGO.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Fire Fighting
Issued 5 April 1991Resolved
D5. PROVIDE SUITABLE FIRE EXTINGUISHERS, (2)-BII, DURING CARGO OPERATIONS. MUST BE COMPLETED PRIOR TO CARRYING CARGO.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Unknown
Issued 27 December 1984Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 27 December 1984
Resolved 27 December 1984
Construction/Loadline
Issued 27 December 1984Resolved
PROCEED TO HOUMA LA FOR REPAIRS. NO CARGO TO BE CARRIED. TEST ALL CARGO TANKS TO DETERMINE ANY LEAKAGE AND REPAIR AS NECESSARY. REPAIRS AND TESTINGTO BE TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR. REPAIRS TO BE COMPLETED BY 10JAN85.
Condition: Unknown
Due 27 December 1984
Resolved 27 December 1984
Documentation
Issued 7 December 1984Resolved
UPGRADE PRESENT OIL TRANSFER PROCEDURES TO COMPLY WITH 33 CFR 155.
Condition: Unknown
Due 7 December 1984
Resolved 7 December 1984
Unknown
Issued 7 December 1984Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL, T 160, CG011312.
Condition: Unknown
Due 7 December 1984
Resolved 7 December 1984