Records from 1994 to 2010. Most recent: inspection, 12 January 2010.
Inspection history · 110
12 January 2010
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3659388
22 July 2009
MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3499354
16 July 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3536438
13 April 2009
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3444186
15 January 2009
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3381229
16 October 2008
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3331822
22 July 2008
COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3242418
29 April 2008
Periodic Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3166705
29 January 2008
Periodic Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3117428
29 October 2007
Re-Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3070478
23 July 2007
MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2973759
25 June 2007
Administrative Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2933837
25 April 2007
Periodic Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2915620
22 January 2007
Administrative Inspection · Re-Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2859878
26 October 2006
Administrative Inspection · Re-Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2808414
27 July 2006
MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2723587
20 April 2006
Administrative Inspection · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2628227
31 January 2006
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2576918
6 October 2005
Deadweight Survey · Re-Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2507929
27 July 2005
COI Inspection · MTSA Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2440225
11 April 2005
Periodic Inspection · MTSA Verification · Deficiency Check
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2331226
11 January 2005
Re-Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2272487
12 October 2004
MTSA Verification · Re-Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2219271
17 August 2004
MTSA Verification
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2173866
28 July 2004
COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2147647
8 June 2004
Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2092275
7 May 2004
Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2061874
12 February 2004
Quarterly Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2005195
4 November 2003
Quarterly Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1941619
28 July 2003
Deficiency Check · COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1855982
15 April 2003
Quarterly Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1773931
28 January 2003
Quarterly Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1736233
4 November 2002
Quarterly Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1700548
30 July 2002
COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1653661
30 July 2002
COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1702852
18 June 2002
Hull Examination · Internal Structural Exam
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1632520
1 May 2002
Quarterly Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1611354
29 January 2002
Deficiency Check · Quarterly Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1382450
30 October 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401585
12 October 2001
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1077161
27 September 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1074468
28 August 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1072766
31 July 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1473421
8 June 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1471422
22 May 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1432506
13 February 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361966
29 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771775
25 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 206964
1 August 2000
Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420376
16 May 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1369677
24 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458753
29 March 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410269
16 February 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1468114
24 January 2000
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 813926
4 January 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 813723
9 December 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 812342
3 November 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1378850
10 August 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447992
21 June 1999
Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410004
25 May 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420142
23 February 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1473505
4 December 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1418442
5 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 801845
18 August 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1472000
10 August 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1455599
8 August 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 53312
4 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 794472
12 May 1998
Damage Survey · Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1375363
3 March 1998
Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1408059
9 February 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 773982
25 November 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1390652
16 October 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 718287
15 October 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1109375
19 September 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 786240
19 August 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445263
16 June 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 774958
12 May 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419772
28 April 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458407
18 February 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1371674
7 February 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1104399
22 November 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435835
20 August 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413038
17 June 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1421182
20 March 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1078480
9 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441075
17 February 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411312
12 February 1996
Initial Construction-Excluding Oversight
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414544
16 November 1995
Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1430126
14 November 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431573
18 October 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412876
15 September 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377516
22 August 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439645
17 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 77259
30 June 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355352
23 May 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1357198
14 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 704141
27 February 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1163177
22 February 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1436954
17 January 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380129
11 January 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 859941
20 December 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1154608
13 December 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1145423
28 November 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467885
25 November 1994
Type not recorded
No type recorded · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 704142
10 November 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1180706
8 November 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 868663
18 October 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 871512
19 September 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1178494
12 September 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 866581
1 September 1994
Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422418
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 15 January 2009
Resolved
Inventory all lifejackets and determine how many have flotation material problems, currently numerous jackets when squeezed have had ther flotation crush, and turn to powder. Hold all damaged jackets for the CG, and note the MFG, Lot #, and date on all jackets that fail.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 January 2009
Resolved 19 January 2009
Electrical › Electric Generation Source (emergency) › Generator
Issued 23 July 2007
Resolved
Emergency generator, when shut down by activation of CO2 fixed firefighting system, will try to start itself and continues to try until stopped by crew. Starter runs continuously. Provide manufacturing report on this sytem to determine whether this is correct.
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 27 July 2007
Resolution: Determined cause to be that starter circuit was not breaking when the CO2 activated shutdown. Installed extra switch & tested sat.
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 25 June 2007
Resolved
Provide Detailed Hull Exam Report (Gauge Readings).
Condition: Unknown
Due 25 July 2007
Resolved 23 July 2007
Resolution: Satisfactory Hull Gauging Report provided.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 26 October 2006
Resolved
5. To be completed no later than 30NOV06: Elevator room Electrical cabinet, house keeping in cabinet, clean inside cabinet remove all old cables, metal shavings, and old parts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 26 October 2006
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 26 October 2006
Resolved
1. To be completed no later than 30NOV06: Provide proper embarkation ladder for aft rescue boat. Current ladder set up is not satisfactory.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 24 January 2007
Electrical › Electric Supply System (service) › Cable
Issued 26 October 2006
Resolved
2. To be completed no later than 30NOV06: Stand pipe for both fwd and aft newly installed rescue boat davits currently threaded into the deck instead of properly welded. Weld same.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 24 January 2007
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 26 October 2006
Resolved
3. To be completed no later than 30NOV06: Port side AC Room overhead insulation missing/incomplete where removed previously, install proper insulation for the A-60Overhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 24 January 2007
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 26 October 2006
Resolved
4. To be completed no later than 30NOV06: For both rescue boat davits provide clarification on actual load rates for davits.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 24 January 2007
Electrical › Lighting (service) › Lighting Feeder
Issued 20 April 2006
Resolved
Remove all wires from discontinued lighting on both stacks.
Due 20 May 2006
Resolved 27 July 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 20 April 2006
Resolved
Fabricate covers for electrical cables on the bridge deck.
Due 20 May 2006
Resolved 27 July 2006
Fire Fighting › Ventilation Systems › Fans
Issued 20 April 2006
Resolved
Lubricate and free up engineroom ventilation louvers on Texas deck aft starboard side.
Due 20 May 2006
Resolved 27 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2006
Resolved
Remove extension cord to ATM money machine on upper deck.
Due 20 May 2006
Resolved 27 July 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 April 2006
Resolved
Replace drink machine outlet plug at upper deck bar (Texas).
Due 20 May 2006
Resolved 27 July 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 April 2006
Resolved
Replace plug receptacle at the mini bar on the main deck.
Due 20 May 2006
Resolved 27 July 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 20 April 2006
Resolved
Repair exhaust leak on #2 generator prior to using generator for supplying power.
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 27 July 2006
Stability › Watertight Integrity › General
Issued 11 April 2005
Resolved
Demonstrate proper operation of the No. 1 sliding watertight door in emergency mode.(using the systems accumulator).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 20 April 2005
Resolution: Door was repaired and tested, test satisfactory.
Construction/Loadline › Structures
Issued 28 July 2003
Resolved
Repair or replace FWD stbd escape hatch.
LEGACY COMPONENT DESC: Scuttle
Condition: Unknown
Due 29 September 2003
Resolved 2 September 2003
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 28 July 2003
Resolved
Repair or replace wasted and rotten paddle wheel boards.
Condition: Unknown
Due 29 September 2003
Resolved 2 September 2003
Electrical › Electrical Distribution System (service)
Issued 28 July 2003
Resolved
Provide proof that the current wiring in the elevator room hyd oil tanks are approved by code. Specifically the butt splices and wire running through the flex conduit. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 15 August 2003
Resolved 2 September 2003
Lifesaving › Inflatable Liferafts
Issued 30 July 2002
Resolved
Prior to vessel getting underway, provide liferaft servicing reports for all life rafts.
Due 30 September 2002
Resolved 4 November 2002
Resolution: Vessel allowed to remove the liferats totally.
Engineering › Diesel Engine (auxiliary)
Issued 30 July 2002
Resolved
Prior to getting vessel underway, repair exhaust leaks at the turbo charger and the exhaust pipe in the overhead.
LEGACY COMPONENT DESC: Turbocharger
Condition: Unknown
Due 30 August 2002
Resolved 19 August 2002
Fire Fighting › Fire Pumps
Issued 1 May 2002
Resolved
Main fire pump discharge voulte assy. holed and leaking IWO discharge port. Make temp. repairs (soft patch) to control leakage. Make permanent repairs to fire pump and prove proper operation to attending marine inspector. LEGACY COMPONENT DESC: Casing
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 30 July 2002
Engineering › Non-conventional Propulsion/Steering › Control Systems (Azipod)
Issued 29 January 2002
Resolved
Prior to vessel getting underway with passengers install interlock controls for bow thruster steerting control stations.
Condition: Improper Installation
Due 29 January 2007
Resolved 24 January 2007
Accommodation/Occupational Safety
Issued 31 July 2001
Resolved
INSTALL PROPER RELIEF VALVES FOR AC CONDENSERS, CURRENTLY WRONG SIZE.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Documentation
Issued 31 July 2001
Resolved
PROVIDE AUTOMATION PROCEDURES IAW 46 CFR 61.40-1C, 61.40-6, AND 61.40-10, AND DEMONSTRATE PROCEDURES. PRIOR TO VESSEL GETTING UNDERWAY.
Condition: Unknown
Due 28 March 2003
Resolved 30 July 2002
Fire Fighting
Issued 31 July 2001
Resolved
RE-PACK FIRE STATION VALVE #5. CURRENTLY LEAKING.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Fire Fighting
Issued 31 July 2001
Resolved
RE-PACK SPRINKLER PUMP, PACKING LEAKING, SYSTEM DID PASS ALL REQUIRED TESTS.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Fire Fighting
Issued 31 July 2001
Resolved
AUDIO GAUGE F/O AND FIREMAIN LINE UNDER FIRE PUMP IN ENGINE ROOM STBD SIDE.CURRENTLY HEAVILY RUSTED AND PITTED, BUT NOT LEAKING. REPAIRS TO BE COMPLETED IAW AUDIO GAUGE RESULTS.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Construction/Loadline
Issued 1 August 2000
Resolved
OPEN VOID SPACES TO ALL BILGE ALARMS AND ENSURE SAFE FOR ENTRY IN ORDER TO TEST BILGE ALARMS.
Condition: Unknown
Due 14 August 2000
Resolved 16 August 2000
Navigation
Issued 1 August 2000
Resolved
OPEN VOID SPACES, ENSURE SAFE FOR ENTRY AND HAVE PRESSURE VESSELS OPEN AND READY FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 14 August 2000
Resolved 16 August 2000
Electrical
Issued 1 August 2000
Resolved
REPLACE BROKEN SIGHT GLASS ON EXPANSION TANK ON PORT S/S GENERATOR.
Condition: Unknown
Due 14 August 2000
Resolved 16 August 2000
Electrical
Issued 1 August 2000
Resolved
REPAIR OIL LEAK IN STBD S/S GEN IN FRONT OF ENGINE.
Condition: Unknown
Due 14 August 2000
Resolved 16 August 2000
Electrical
Issued 1 August 2000
Resolved
REPAIR/REPLACE HIGH OIL TEMP SENDING UNIT ON STBD S/S GENERATOR.
Condition: Unknown
Due 14 August 2000
Resolved 16 August 2000
Electrical
Issued 1 August 2000
Resolved
INSTALL PROPER OUTLET FOR TV IN ENGINE ROOM AND REMOVE EXTENSION CORD.
Condition: Unknown
Due 14 August 2000
Resolved 16 August 2000
Electrical
Issued 1 August 2000
Resolved
REPAIR EXHAUST LEAKS ON BOTH S/S GENERATORS.
Condition: Unknown
Due 14 August 2000
Resolved 16 August 2000
Unknown
Issued 4 December 1998
Resolved
Clean engine room bilges of all rags, currently areas of concentrated rag pile ups.
Condition: Unknown
Due 16 December 1998
Resolved 16 December 1998
Engineering
Issued 4 December 1998
Resolved
REPAIR STBD GEN OIL TEMP ALARM PANEL CURRENTLY MALFUNCTIONING. SENSOR HAS BEEN TESTED AND PROBLEM DETERMINED TO BE ALARM PANEL. BY CAT. ENG MECHANICS. PROPER REPAIRS REQUIRED.
Condition: Unknown
Due 16 December 1998
Resolved 16 December 1998
Engineering
Issued 10 August 1998
Resolved
PROVIDE APPROVAL FOR INSTALLING 2 PIECE (LENGTH WISE) PADDLE WHEEL BOARDS VICE ORIGINAL CONSTRUCTION OF ONE PIECE. PROVIDE ORIGINAL APPROVED PLANS, SUBMITT TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Lifesaving
Issued 10 August 1998
Resolved
PROVE COMPLIANCE W/LIFESAVING REQS OF 46 CFR TABLE 75.10-20(A) SPECIFICALLYWORKING BOAT. VSL TO PROVIDE ANY AVAIL INFO REGARDING REASON FOR 5 RAFTS ORIGINALLY INSTALLED VICE 4. PERMITTED TO OPERATE W/4 - 50 MAN RAFTS IN INTERIM AS NECESSARY FOR LIFERAFT SERVICING. WILL EVAL 19AUG98 AT COI.
Condition: Unknown
Due 19 August 1998
Resolved 10 August 1998
Engineering
Issued 12 May 1998
Resolved
REPLACE PADDLEWHEEL PLANKS AS NECESSARY TO THE SATISFACTION OF THE [name withheld].
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Engineering
Issued 12 May 1998
Resolved
PROVIDE PROPOSAL TO EFFECT PROPER REPAIRS TO PADDLEWHEEL PLANKS.
Condition: Unknown
Due 4 June 1998
Resolved 1 July 1998
Lifesaving
Issued 3 March 1998
Resolved
PROVIDE SAT. EGRESS RAMP AT AFT MAIN DECK EXIT TO LANDSIDE. CURRENTLY RAMPPROHIBITS EGRESS THROUGH DOOR AT LOW WATER. WHILE PASENGERS ON BOARD AT DOCK, AFIX EGRESS RAMP AT AFT UPPERDECK GOING LANDSIDE, POST CREW MEMBER ATUPPER AND LOWER EGRSS POINTS TO DIRECT TRAFFIC, POST SIGNS AT STATIONS.
Condition: Unknown
Due 10 March 1998
Resolved 12 March 1998
Unknown
Issued 3 March 1998
Resolved
MOVE AND RE-MOUNT AIR OIL/WATER SEP. IN EMERGENCY GEN ROOM. CURRENTLY MOUNTED BEHIND AND SLIGHTLY ABOVE A TRANSFORMER, AND BEING BLED RIGHT ON THE TRANSFORMER. DO NOT USE THIS STATION UNTIL MOVED.
Condition: Unknown
Due 17 March 1998
Resolved 12 March 1998
Electrical
Issued 3 March 1998
Resolved
PROPERLY RE-INSTALL STUFFING TUBE CONNECTORS ON ALL BRIDGE DECK LARGE FLOODLIGHTS. CURRENTLY MANY NOT PROPERLY INSTALLED, AND 2 MISSING STUFFING TUBEGROMMETS AND NUTS.
Condition: Unknown
Due 17 March 1998
Resolved 12 March 1998
Documentation
Issued 15 October 1997
Resolved
VESSEL HAS 24 HOURS TO PRODUCE PROOF OF A NEW COFR, CURRENT ONE HAS EXPIRED ON THE 8TH OF SEP97.
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997
Fire Fighting
Issued 12 May 1997
Resolved
Clean/Service all smoke detectors, conduct test, and provide evidence of successful test conducted by certified fire protection company._x001C_ *Master shall provide active fire watch until smoke detection system servicing is complete and inspected by cognizant OCMI.
Condition: Unknown
Due 22 May 1997
Resolved 14 May 1997
Fire Fighting
Issued 20 August 1996
Resolved
Prior to vessel cetting underway make temp repairs to sprinkler pump systemby installing a temp pump. To be completed to satisfaction of USCG Marine Inspector.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Fire Fighting
Issued 20 August 1996
Resolved
Make proper and permenant repairs to the sprinkler pump system. Current pump unable to meet requirements.
Condition: Unknown
Due 26 August 1996
Resolved 21 August 1996
Documentation
Issued 12 February 1996
Resolved
REDUCE TOTAL NUMBER OF PASSENGERS PERMITTED ONBOARD FROM 2,000 TO 1650 UNTIL QUALIFIED REFUGE AREA ON TEXAS DECK IS RESTORED.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Lifesaving
Issued 12 February 1996
Resolved
PROVIDE STANDBY FIRE TRUCK SUPPORT ON DOCK WHEN FIREMAIN OR SPRINKLER SYSTEMS ARE SECURED FOR CONNECTION.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Construction/Loadline
Issued 12 February 1996
Resolved
DO NOT CUT OR BURN ON VESSEL WHEN UNDERWAY OR AWAY FROM DOCK. FIRE WATCHES WILL BE POSTED WHEN CUTTING OR BURNING. ALL PASSENGERS & UNNECESSARY PERSONNEL WILL BE CLEAR OF COMPARTMENT WHEN FIRE WATCHES ARE POSTED.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Lifesaving
Issued 12 February 1996
Resolved
ENSURE PASSENGERS HAVE A CLEAR EGRESS PATH THROUGH CONSTRUCTION AREA DURINGMODIFICATIONS TO TEXAS DECK.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Fire Fighting
Issued 22 August 1995
Resolved
REPLACE ALL FADED LABELING ON EXTERIOR OF VESSEL FOR EMERGENCY LIGHTS, FIRESTATIONS AND LIFE JACKET STORAGE.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Accommodation/Occupational Safety
Issued 22 August 1995
Resolved
PROPERLY SECURE CIGARETTE MACHINE ON MAIN DECK.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Construction/Loadline
Issued 22 August 1995
Resolved
PROVIDE AN ACCESS PLATE TO THE PACKING GLAND ON THE SPRINKLER PUMP.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Fire Fighting
Issued 22 August 1995
Resolved
PROVE PROPER OPERATION OF SPRINKLER LEVEL ALARM. IN ADDITION, EVERY FOUR (4) HOURS THE ENGINEER ON WATCH SHALL OBSERVE THE LEVEL OF THE PRESSURE TANK AND LOG IN THE OFFICIAL LOGBOOK THAT THIS WAS ACCOMPLISHED.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Accommodation/Occupational Safety
Issued 22 August 1995
Resolved
PROVIDE PERMANENT SECURING SYSTEM FOR SODA SYSTEM CO2 CYLINDERS IN SODA ROOM AND CREW BREAKROOM.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Lifesaving
Issued 22 August 1995
Resolved
PROVIDE PERMANENT, SECURED SHELVING FOR STORAGE OF LIQUOR AND SODA IN LIQUOR AND SODA DISTRIBUTION ROOMS. UNTIL SHELVING IS INSTALLED, ONLY A DAILY SUPPLY OF LIQUOR TO BE CARRIED ON BOARD.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Fire Fighting
Issued 22 August 1995
Resolved
REPLACE BROKEN BRACKET FOR FIRE EXTINGUISHER NUMBER 13- IN FIRE STATION.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Accommodation/Occupational Safety
Issued 22 August 1995
Resolved
CLEAN OUT THE PASSENGER ELEVATOR PITS OF OIL SOAKED ABSORBENT.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Construction/Loadline
Issued 22 August 1995
Resolved
PROVIDE QUICK CLOSING VALVES ON SOUNDING TUBES BELOW THE MAIN DECK.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Lifesaving
Issued 22 August 1995
Resolved
INSTALL PROPER LIFTING PADEYES FOR HARNESSES ON BOTH RESCUE BOATS.
Condition: Unknown
Due 22 August 1995
Resolved 22 August 1995
Fire Fighting
Issued 22 August 1995
Resolved
PROVIDE A FIRE MAIN PRESSURE GAUGE ON THE BRIDGE.
Condition: Unknown
Due 22 August 1995
Resolved 22 August 1995
Engineering
Issued 22 August 1995
Resolved
PROVE PROPER OPERATION OF BOTH AIR RECEIVERS RELIEF VALVES, AS WELL AS THE RELIEF VALVE ON THE INBOARD SPRINKLER PRESSURE TANK.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Electrical
Issued 23 May 1995
Resolved
PROVE PROPER OPERATION OF REVERSE POWER TRIP ON #2 SSDG
Condition: Unknown
Due 6 June 1995
Resolved 31 May 1995
Fire Fighting
Issued 23 May 1995
Resolved
REPLACE/REPAIR INSULATION SPEED CLIPS WITH 1 1/4" CLIPS IAW NVIC 6-80
Condition: Unknown
Due 30 June 1995
Resolved 19 July 1995
Accommodation/Occupational Safety
Issued 17 January 1995
Resolved
PROVIDE MEANS OF LOCKING PORT SIDE AFT ENTRY DOOR. KEY FOR LOCK MUST BE ENCASED IN GLASS IN VICINITY OF THE DOOR.
Condition: Unknown
Due 5 February 1995
Resolved 31 January 1995
Engineering
Issued 28 November 1994
Resolved
Make repairs to engine room alarm console including: False indication on bow thruster room bilge level, stbd steering pump power failure, and 24 VDCsteering control power failure.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994
Electrical
Issued 28 November 1994
Resolved
Make repairs/modifications to No. 2 generator reverse power relay.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994
Electrical
Issued 28 November 1994
Resolved
Move radio repeater power source to emergency circuit to provide for emergency radio communications.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994
Electrical
Issued 28 November 1994
Resolved
Install electric safety mats in front of all major switchboards. (Engine room & Emergency generator room). Present mats are not di-electric or are missing altogether.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994
Fire Fighting
Issued 28 November 1994
Resolved
Correct alarm trouble light at fire panel to allow audible alarm of sprinkler system.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994
Construction/Loadline
Issued 28 November 1994
Resolved
Correct malfunction in all outer casino door latches to allow opening from inside as well as outside.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994
Accommodation/Occupational Safety
Issued 1 September 1994
Resolved
INSTALL SELF CLOSING DEVICES ON UPPER DECK (PADDLE WHEEL OBSERVATION AREA) DOORS PORT AND STBD. CREW MEMBER TO BE ON WATCH AT DOORS UNTIL REPAIRS HAVE BEEN MADE.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Electrical
Issued 1 September 1994
Resolved
REPLACE EXISTING DUCT HEATERS WITH U.L. 1096 APPROVED UNITS IAW 46 CFR 111.87 (SEE ABS COMMENT LETTER). ALL HEATERS ARE TO REMAIN DISCONNECTED UNTIL NEW HEATERS ARE INSTALLED AND APPROVED BY [name withheld].
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Fire Fighting
Issued 1 September 1994
Resolved
PROVIDE INSULATION IAW 46 CFR 72.05-5(a)(1) FOR ENGINE CONTROL SPACE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Documentation
Issued 1 September 1994
Resolved
SUBMIT SIX (6) COPIES OF UPDATED FIRE CONTROL PLAN TO [name withheld] FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 11 September 1994
Resolved 19 September 1994
Accommodation/Occupational Safety
Issued 1 September 1994
Resolved
RENEW MAIN DECK PORT SIDE AFT ENTRY DOOR AND FRAME. CREW MEMBER MUST BE ONWATCH AT DOOR UNTIL REPAIRS HAVE BEEN MADE.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Documentation
Issued 1 September 1994
Resolved
COMPLETE ALL OUTSTANDING ABS COMMENTS.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Lifesaving
Issued 1 September 1994
Resolved
REPLACE ALL TECH SCREWS WITH COUNTER SUNK SCREWS IN "BOTH" MACHINERY SPACES.
Condition: Unknown
Due 11 September 1994
Resolved 19 September 1994