Records from 2016 to 2025. Most recent: inspection, 10 July 2025.
Inspection history · 20
10 July 2025
Annual Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8160456
16 July 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7959354
15 May 2024
Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7912716
6 December 2023
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7835836
19 July 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7746457
13 July 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7504899
6 December 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7362942
19 July 2021
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7260680
10 August 2020
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7028896
15 July 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7007878
10 September 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6808104
9 October 2018
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6553905
27 August 2018
Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6524413
16 August 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6513688
9 November 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6304010
28 August 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6253665
3 November 2016
Hull Examination · Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6034389
28 July 2016
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5956858
19 July 2016
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5948142
27 June 2016
Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5921470
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2025
Resolved
In the inspection of hulls, boilers, and machinery of vessels, the standards established by the American Bureau of Shipping, see part 90, subpart 90.35 of this chapter, respecting material and inspection of hulls, boilers, and machinery, and the certificate of classification referring thereto, except where otherwise provided for by the rules and regulations in this subchapter, subchapter E (Load Lines), subchapter F (Marine Engineering), subchapter J (Electrical Engineering).
Boiler inspection is overdue.
46CFR91.15
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2025
Resolved 30 July 2025
Resolution: Conducted inspection and tested all safeties, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 July 2025
Resolved
All electrical engineering details and installations shall be designed and installed in accordance with subchapter J (Electrical Engineering) of this chapter.
Engine Room emergency lighting is inadequate.
46 CFR 90.25-1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2025
Resolved 13 March 2026
Resolution: New lighting fixtures installed
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 19 July 2021
Resolved
The keeper nut on the anchor swivel is at the end of the threads, tighten up the nut as discussed.
Action required: 10 - Deficiency Rectified
Resolved 19 July 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 July 2021
Resolved
The pressure switch for the CO2 is not operating properly, demonstrate proper operation.
Action required: 10 - Deficiency Rectified
Resolved 19 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 19 July 2021
Resolved
Provide the proper signage for operation (46 CFR 95.15-10(h) of the CO2 system and warnings
(46 CFR 97.37-11)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2021
Resolved 19 July 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 July 2020
Resolved
Refs: 46 CFR 91.25-20 / NFPA 10
CO2 bottles were not weighed by Sea Safety at annual servicing IAW 46 CFR and NFPA 10. Vessel must prove the bottles are in compliance with annual servicing requirements of all applicable regulations. Ambient temp and liquid level indicator accepted no longer accepted.
**BOTTLES MUST BE WEIGHED AT COI IN 2021**
Action required: 10 - Deficiency Rectified
Due 15 July 2020
Resolved 15 July 2020
Resolution: Alternative means of determining serviceability accepted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 July 2020
Resolved
46 CFR 95.05-1 / Sub H
Galley smoke detector expired. Independent device was installed in 2000; sensor life cycle 10 years. Detector expired 2010. Must replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 21 July 2020
Resolution: Replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 July 2020
Resolved
46 CFR 91.25-35 / Sub F
Port-side engine shift cable severely chaffed. Must replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 27 July 2020
Resolution: Replaced
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 July 2016
Resolved
Rubber hose on the S/W OVBD for the STBD main needs to be replaced. Prior to going back in service after upcoming dry-dock.
Action required: 705 - Other - as specified
Resolved 28 July 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 July 2016
Resolved
Replace the S/W hoses on both mains from the strainer to the pump inlet. Prior to going back in service after upcoming dry-dock.
Action required: 705 - Other - as specified
Resolved 28 July 2016
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 19 July 2016
Resolved
Prove proper operation of the low L/O alarm for the STBD main.
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 19 July 2016
Resolution: (Cleared on site)
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 19 July 2016
Resolved
The relief valve on the boiler did not relieve at the proper PSI. Need to prove proper operation of the relieving device. Prior to going back in service after upcoming dry-dock.
Action required: 705 - Other - as specified
Resolved 28 July 2016
Engineering › Pressure Vessel › Pressure Gauge
Issued 19 July 2016
Resolved
Perform hydro test on the boiler. Prior to going back in service after upcoming dry-dock.
Action required: 705 - Other - as specified
Resolved 28 July 2016