MAURY USCG vessel records Sign in
← All vessels

R/V ADAM HYLER

R/V ADAM HYLER is a 1953 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 1985, most recently in March 2000, along with 57 deficiencies — 3 with no resolution recorded —.

Records from 1985 to 2000. Most recent: inspection, 27 March 2000.

Built
1953
Last inspected
27 March 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ2971
Flag
UNITED STATES
366767080 (licence lapsed)
Maury page id
psix-41161

Inspections, by type

…with no type recorded2
Years with a record 13 calendar years (1985–2000)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it46 - Simplified, Gross Ton
37 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCZ2971MMSI 366767080 · expired · voluntarily equipped · granted 26 May 1999, cancelled 1 August 2009
WCY4689MMSI not assigned · expired · voluntarily equipped · granted 16 June 1998, cancelled 16 August 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 24

27 March 2000 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1421968
1 February 2000 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1432237
15 July 1998 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 794581
22 April 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 778477
28 October 1997 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1437315
2 December 1996 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1183846
28 September 1994 COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1181198
27 September 1994 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1183105
10 February 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853998
2 December 1992 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 831476
1 October 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944856
29 April 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 947588
3 February 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1259313
8 October 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258517
21 September 1990 COI Inspection · Plan Review "T" Boat · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1217376
30 August 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1217374
29 August 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328496
23 February 1988 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024424
20 January 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337845
19 December 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327872
21 October 1986 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1325513
24 September 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1325515
10 October 1985 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 988596
28 June 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1291522

Deficiency record · 57

Construction/Loadline
Issued 1 February 2000 Resolved
Audio gauge the lower half of the collision bulkhead from the forepeak side.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Construction/Loadline
Issued 1 February 2000 Resolved
Replace all missing deck plates in compartment #2.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Stability › Incline Test › General
Issued 1 February 2000 Resolved
Submit a ballast plan; showing the amount, location, and method of securingballast to be returned the vessel. Ballast must be secure and up off of the hull plating in a tray or similar arrangement._x001C_ All ballast must be in place prior to conducting the stability test.
Condition: Unknown
Due 12 February 2000
Resolved 26 October 2004
Resolution: CLEARED FOR ADMIN CLEAN UP.
Construction/Loadline
Issued 1 February 2000 Resolved
Crop to good metal and renew the cut frames in the bilge in compartment #2 as marked.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Construction/Loadline
Issued 1 February 2000 Resolved
Crop to good metal and renew the improper repair to shower overboard discharge with an 18"x18" insert.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Engineering
Issued 1 February 2000 Resolved
Empty, clean, and make available for internal inspection: both main fuel tanks.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Construction/Loadline
Issued 1 February 2000 Resolved
Crop to good metal and renew the hull plating from transom, the aft 6 frames as marked. Plating to be renewed as original.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Accommodation/Occupational Safety
Issued 1 February 2000 Resolved
Repair aft life line.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Construction/Loadline
Issued 1 February 2000 Resolved
Crop to good metal and renew hole in Garboard hull plate on STBD side between keel and keel cooler as marked.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Construction/Loadline
Issued 1 February 2000 Resolved
C&R centerline longitudinal between rudder post and transom.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Construction/Loadline
Issued 1 February 2000 Resolved
Remove all ballast material from fore peak and compartment #2 for further inspection and stability test. (Note the amount of ballast and it's location)
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Stability › Incline Test › General
Issued 1 February 2000 Resolved
Conduct a simplified stability test in the presence of the attending USCG Marine Inspector.
Condition: Unknown
Due 12 February 2000
Resolved 26 October 2004
Resolution: CLEARED FOR ADMIN CLEAN UP.
Construction/Loadline
Issued 1 February 2000 Resolved
C&R #3 from aft, the transverse frame on the port side and intersecting longitudinal #3 from port as marked.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Documentation
Issued 22 April 1998 Resolved
OBTAIN A NEW FCC RADIO SAFETY TELEPHONY CERTIFICATE. VESSEL RESTRICTED TO NMT 1000 FEET FROM SHORE UNTIL CLEARED.
Condition: Unknown
Due 31 August 1998
Resolved 15 July 1998
Operations/Management › Drills/Instruction › Fire
Issued 22 April 1998 No resolution recorded
PROVIDE PROOF OF CREW TRAINING AND DRILLS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 22 April 1998 No resolution recorded
SHOW PROOF OF COMPLIANCE W/ CG DRUG TESTING REGULATIONS PRIOR TO CARRYING PASSENGERS FOR HIRE,
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline
Issued 22 April 1998 Resolved
CROP AND RENEW WASTED AREAS BELOW PASSENGER SEATING IWO PFD STORAGE AREAS.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Personnel › Certificates/Documents/Licenses › License, Master
Issued 22 April 1998 No resolution recorded
PROVIDE A COPY OF MASTERS LICENSE PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting
Issued 22 April 1998 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Electrical
Issued 3 February 1992 Resolved
PROVIDE AN ACID RESISTANT TRAY/ LINING FOR STARTING BATTERY CONTAINER FOR 110 VAC GENERATOR.
Condition: Unknown
Due 3 February 1992
Resolved 3 February 1992
Engineering
Issued 3 February 1992 Resolved
REPLACE NON-MARINE FUEL FILTER ON 110 VAC GENERATOR WITH A FLAME SHIELDED MARINE FUEL FILTER. NOTE PET COCKS ARE NOT PERMITTED IN FUEL SYSTEMS. FILTER INSTALLED IS FOR AUTOMOTIVE USE.
Condition: Unknown
Due 3 February 1992
Resolved 3 February 1992
Engineering
Issued 3 February 1992 Resolved
REPLACE FLEXIBLE FUEL HOSES FOR 110 VAC GENERATOR FUEL SUPPLY WITH FLAME SHIELDED (SHELF EXTINGUISHING OUTER JACKET) HOSES.
Condition: Unknown
Due 3 February 1992
Resolved 3 February 1992
Construction/Loadline
Issued 3 February 1992 Resolved
CLEAN FORE PEAK, REMOVE ICE AND WATER INSURE PROPER OPERATION OF BILGE SUCTION AND VALVE CONTROLS.
Condition: Unknown
Due 3 February 1992
Resolved 3 February 1992
Deck/Cargo
Issued 3 February 1992 Resolved
PROVIDE A PLAN / SKETCH SHOWING INSTALLATION DETAILS OF NEW DECK MACHINERY.SHOW MOUNTAINS AND FOUNDATIONS, SOURCE OF POWER AND SPECIFICATIONS FOR HYDRALLIC PIPING AND CONTROL, ALL DECK AND BHD PENETRATIONS.
Condition: Unknown
Due 3 February 1992
Resolved 3 February 1992
Navigation
Issued 3 February 1992 Resolved
CLEAN & LUBRICATE STEERING CABLE IN SPACE BELOW AFT HATCH.
Condition: Unknown
Due 3 February 1992
Resolved 3 February 1992
Engineering
Issued 8 October 1991 Resolved
RECHARGE 50# CYL FOR FIXED CO2 SYSTEM PRIOR TO SAILING WITH PASSENGERS.
Condition: Unknown
Due 24 February 1992
Resolved 24 February 1992
Fire Fighting
Issued 8 October 1991 Resolved
HYDROTEST 2 BII FIRE EXTINGUISHERS PRIOR TO SAILING.
Condition: Unknown
Due 24 February 1992
Resolved 24 February 1992
Electrical
Issued 21 September 1990 Resolved
WIRING AND PIPING INSTALLATION FOR NEW TYPE II MSD EXAMINE AND APPROVED BY INSPECTOR. APPROVED PLAN NOT REQUIRED DUE TO SIMPLICITY OF INSTALLTION.
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Construction/Loadline
Issued 21 September 1990 Resolved
CLEANED AND LAPPED SEAT ON SANITARY DISCHARGE SEA GLOBE VALVE
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Construction/Loadline
Issued 21 September 1990 Resolved
REPLACED HATCH SECURING CHAINS
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Engineering
Issued 21 September 1990 Resolved
TESTED ALL OPERATIONAL EQUIPMENT
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Lifesaving
Issued 21 September 1990 Resolved
RENEWED OUTDATED DISTRESS SIGNALS
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Lifesaving
Issued 21 September 1990 Resolved
BROKE OUT ALL LIFE SAVING AND FIRE PROTECTION EQUIPMENT FOR EXAMINATION, CLEANED ALL STORAGE AREAS AND EQUIPMENT. TESTED /WEIGHED EQUIPMENT AS REQ._x001C__x001C_ _x001C_
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Lifesaving
Issued 21 September 1990 Resolved
MOUNTED BUOYANT APPARATUS AND WATER LIGHTS ON WEATHER DECK IN READY FOR USEPOSITION.
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Lifesaving
Issued 21 September 1990 Resolved
PROVIDED 6 CHILD PFDS, MAKE STORAGE FOR CHILD PFDS
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Lifesaving
Issued 21 September 1990 Resolved
PROVIDED 2 ADULTS PFDS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Lifesaving
Issued 21 September 1990 Resolved
MARKED CAPACITY ON BUOYANT APPARATUS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Documentation
Issued 21 September 1990 Resolved
PROVIDED FCC RADIOTELEPHONE SAFETY CERT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Lifesaving
Issued 21 September 1990 Resolved
MARKED ALL PFD STORAGE
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Construction/Loadline
Issued 21 September 1990 Resolved
CROPPED AND RENEWED WASTED BOTTOM FRAME BELOW AFT HATCH
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Electrical
Issued 21 September 1990 Resolved
INSTALLED A MAIN DISCONNECT SWITCH FOR THE STARTING BATTERY OF THE DISEL GENERATOR
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Accommodation/Occupational Safety
Issued 21 September 1990 Resolved
SECURED MSD TANKS TO FOUNDATION_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Construction/Loadline
Issued 21 September 1990 Resolved
COMPLETED WELDING AND AIR/HOSE TEST OF INSERT ON FWD BHD ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Lifesaving
Issued 21 September 1990 Resolved
RENEWED LIFE LINES ON BUOYANT APPARATUS AND REINSTALLED W/ FLOAT FREE LINK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Documentation
Issued 21 September 1990 Resolved
PROVIDED CHARTS, TIDE TABLES, COAST PILOT, CURRENT TABLES, NOTICE TO MARINERS, COMPASS DEVIATION CARD.
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Accommodation/Occupational Safety
Issued 21 September 1990 Resolved
REPAIRED LIFE LINES AND REINSTALLED MISSING SECTIONS.
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Documentation
Issued 21 September 1990 Resolved
POSTED REQUIRED SAFETY AND EMERGENCY INSTRUCTIONS THROUGH OUT THE VESSEL _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Engineering
Issued 21 September 1990 Resolved
OPENED AIR RECEIVER FOR INTERNAL EXAM.
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Navigation
Issued 21 September 1990 Resolved
REPAIRED AND PROVED OPERATION OF NAV LIGHTS, GENERAL ALARM, AND EMERGENCY LIGHTING
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Electrical
Issued 21 September 1990 Resolved
TESTED DIESEL AUX GENERATOR UNDER FULL LOAD OF EQUIPMENT ABOARD
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Accommodation/Occupational Safety
Issued 21 September 1990 Resolved
TESTED OPERATION OF MSD_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Construction/Loadline
Issued 20 January 1988 Resolved
REPAIR OR REPLACE THE CRACKED PORT HOLE IN THE SECOND COMPARTMENT.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Electrical
Issued 20 January 1988 Resolved
PROVIDE GLOBES ON LIGHT FIXTURES IN SECOND COMPARTMENT.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Accommodation/Occupational Safety
Issued 20 January 1988 Resolved
PROVIDE PROTECTIVE GUARD FOR THE SPACE HEATER IN THE FWD PASSENGER CABIN.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Lifesaving
Issued 20 January 1988 Resolved
PROVIDE 6 HAND HELD RED FLARES AND 6 HAND HELD ORANGE SMOKE FLARES.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Accommodation/Occupational Safety
Issued 20 January 1988 Resolved
REMOVE OR PROPERLY REWIRE STOVE IN THE SECOND COMPARTMENT.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Lifesaving
Issued 10 October 1985 Resolved
PROVIDE AN APPROVED FLOAT-FREE LINK AND 100 FT PAINTER FOR BUOYANT APPARAT-US PRIOR TO 24 OCT 85.
Condition: Unknown
Due 10 October 1985
Resolved 10 October 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.