Documentation record
Registered dimensions (L × B × D)46.0 ft × 17.0 ft × 6.0 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMIDSHIP MARINE INC · HARVEY, LA, UNITED STATES · built 1994
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portHYANNIS, MA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 24 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
19 - Simplified, Net Ton
18 - Dead Weight, Ton
21 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 21 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 21
20 April 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8352707
22 January 2026
Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8300797
2 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8119967
2 April 2024
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7888140
18 January 2024
Internal Structural Exam · Examination of Repairs · Deficiency Check · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7848264
27 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7815199
12 June 2023
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7703836
3 April 2023
Deadweight Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7662509
18 January 2023
Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7622354
23 May 2022
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7455252
14 December 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7368026
18 October 2021
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7337161
4 September 2020
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7049222
23 January 2020
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6891327
26 September 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6816507
16 October 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6560056
18 January 2018
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6339729
21 July 2017
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6219568
20 July 2017
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6199843
22 June 2016
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5916886
15 January 2016
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5798326
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 May 2025
Resolved
Vessels on oceans route are required an interconnected fire detection system. No interconnected fire detection system was onboard.
Action required: 10 - Deficiency Rectified
Due 2 May 2025
Resolved 2 May 2025
Resolution: Blue tooth connected smoke detectors were installed on the bridge, passenger area and both engine rooms. System was tested with smoke.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2023
Resolved
Alterations to the hull shall not be made without the approval of the [name withheld] modifications were made without MSC approval of structural plans. Submit plans to MSC for review and approval. 46CFR176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 January 2024
Resolution: Received a copy of MSC approval
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 January 2023
Resolved
Alterations to the hull must not be made without the approval of the [name withheld] modifications were made without prior approval of plans. Submit plans to MSC for approval. Provide copy of approved plans.
Prior to Certification.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 June 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 January 2023
Resolved
Alterations to the hull must not be made without the approval of the OCMI. All bow modification were completed without CG oversight. Attending Marine Inspector to verify work was completed per approved plans.
Prior to Certification.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 June 2023
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 18 January 2023
Resolved
All calculations must be submitted with the required plans. Calculations must account for the weight of all loads. Vessel completed modifications to bow, removed existing life floats and installed new IBA. Submit weight change calculations IAW MTN 04-95 to MSC for stability review. Provide copy of new stability letter or MSC response letter indicating current stability letter is still valid.
Prior to Certification.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 18 January 2023
Resolved
Alterations to equipment must not be made without the approval of the OCMI. 03 life floats were removed and 01 life raft was installed without CG oversight. Installation of IBA needs to be verified by attending MI.
Prior to Certification.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 June 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 July 2022
Resolved
COI is not valid due to vessel being sold. Conduct COI inspection for re-issuance of COI with updated name and vessel owner/operator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2022
Resolved 13 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2021
Resolved
Bilge system needs to be re-labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2021
Resolved 18 October 2021
Resolution: Captain re-labeled bilge system.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 4 September 2020
Resolved
Vessel is restricted to 3 miles due to buoyant apparatus being wasted. Vessel must replace lifesaving equipment prior to operating oceans as indicated on the COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2020
Resolved 2 May 2021
Resolution: Vessel obtained new lifesaving equipment to replace the non-serviceable items.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 September 2019
Resolved
Provide Documentation of the new life floats prior to next operating season.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 October 2020
Resolved 2 May 2021
Resolution: Appropriate documentation regarding new lifesaving equipment was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 September 2019
Resolved
Several life jacket lights are not working. Rpelace lights prior to sailing at night or oceans route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2019
Resolved 30 October 2019
Resolution: Jackets have been cleared
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 September 2019
Resolved
Vessel shall have 6 orange smoke distress signals while operating oceans.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2019
Resolved 30 October 2019
Resolution: Flares have been updated.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 July 2017
Resolved
Vessel's bilge high water alarms do not operate. Vessel is to repair or replace prior to taking passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2017
Resolved 21 July 2017
Resolution: Vessel was able to repair the alarms and demostrate to CG; all sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 July 2017
Resolved
Vessel's waterlight battery for the lifebouy waterlight does not work. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 25 July 2017
Resolution: Vessel rep provide evidence of replacing the waterlight battery; all sat.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 15 January 2016
Resolved
Port prop is damaged and the key is covered by the zinc. Remove
zinc and check the key way.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2016
Resolution: Props are in good condition.
Engineering › Fuel Oil Service System › Piping
Issued 15 January 2016
Resolved
Stbd side fuel tank fitting is leaking. Most likely needs to be
tightened up
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2016
Resolution: Fitting has been tightened and is no longer leaking.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 15 January 2016
Resolved
Red electronic device in stbd space is partically disconnected and wires
are exposed. Reapir device or remove it
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2016
Resolution: Electroninc device has been repaired.
Engineering › Steering Gear System › Piping
Issued 15 January 2016
Resolved
Stbd laz piping is disconnected and the fittings are wasted. Secure
piping and replace fittings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2016
Resolution: Piping and fitting have been repaired.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 January 2016
Resolved
05: Stbd side electrical outlet broken. Repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2016
Resolution: Otlet box has been repaired.
Construction/Loadline › Hull › Girder
Issued 15 January 2016
Resolved
Port skirt weld is cracked approximately 5 feet in length. V and Weld.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 April 2016
Resolution: Fractured weld has been repaired satisfactory.