Records from 1997 to 1999. Most recent: inspection, 9 December 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Construction/Loadline
Issued 9 December 1999
No resolution recorded
Correct Loadlines to reflect Loadline Certificate - ICLL 1966, Reg 25
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Documentation
Issued 9 December 1999
Resolved
SOPEP does not have U.S. local contact information - 33 CFR 151.26(b)(iii)
Condition: Unknown
Due 9 December 1999
Resolved 12 December 1999
Lifesaving
Issued 9 December 1999
No resolution recorded
Port and starboard lifeboat davit arms and port side winch/brake foundationexcessively wasted - SOLAS 74 amended I/11
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Lifesaving
Issued 9 December 1999
No resolution recorded
Port and starboard side embarkation ladders inadequate; starboard side doesnot reach the waters edge, port side attachment wasted - SOLAS 74 amended I/11
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Deck/Cargo
Issued 9 December 1999
No resolution recorded
All cargo hold access covers and #3 main hatch cover wasted and not watertight - ICLL 1966 I/14
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 December 1999
No resolution recorded
Aft deckhouse superstructure holed in numerous locations at main deck level- ICLL 1966 Article 15
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 December 1999
No resolution recorded
Exterior watertight doors on forward and aft deckhouses are wasted and not watertight - ICLL 1966 I/12
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 December 1999
No resolution recorded
Forecastle hatch not watertight - ICLL 1966 I/14
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Fire Fighting
Issued 9 December 1999
No resolution recorded
Fire hose and nozzle is not available for immediate use at every fire hydrant - SOLAS 74, II-2/5
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Fire Fighting
Issued 9 December 1999
No resolution recorded
Firemain pressure inadequate due to holes in main deck piping - SOLAS 74 amended, I/11
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Engineering
Issued 9 December 1999
No resolution recorded
Fuel oil tank vent, mid-ships port side holed - SOLAS 74 amended, I/11
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Engineering
Issued 9 December 1999
No resolution recorded
Hatch to engine room, aft port side main deck, not watertight - ICLL 1966 I/14
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Lifesaving
Issued 9 December 1999
No resolution recorded
Numerous lifebuoy handlines dry-rotted - SOLAS 74 AM, I/11
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Unknown
Issued 9 December 1999
No resolution recorded
Vessel is to make all permanent repairs recommended by class survey record #99TK0749 dated 12DEC99, to be done prior to next U.S. port._x001C_
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 9 December 1999
No resolution recorded
Railing port side main deck broken - ICLL 1966 Reg 6 and 8
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Lifesaving
Issued 9 December 1999
No resolution recorded
Starboard lifeboat outboard fwd sheave stuck - SOLAS 74 AM I/11
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Electrical
Issued 9 December 1999
No resolution recorded
Open electrical wiring - bow thruster fan, SS forward; CO2 room fan, SS forward; drying room/laundry fan, SS forward; accommodation ladder winch motors, SS and PS. - SOLAS 74, II-1/27_x001C_
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Engineering
Issued 9 December 1999
No resolution recorded
Five soft patches, generator cooling water piping - SOLAS 74 AM I/11
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Documentation
Issued 9 December 1999
No resolution recorded
Conduct crew safety and familiarization training - SOLAS 74 AM III/18.4 and5; STCW 95 Reg I/14
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Lifesaving
Issued 9 December 1999
No resolution recorded
Provide sufficient number of liferafts as per SOLAS Safety Equipment Certificate - SOLAS 74 AM I/11
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Engineering
Issued 9 December 1999
No resolution recorded
Obtain operations manual for Oily-water Separator - MARPOL 73/78 I/16
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 9 December 1999
No resolution recorded
Obtain required chemicals for Marine Sanitation Device - 33 CFR 159.7(a)(1)
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Documentation
Issued 9 December 1999
Resolved
Oil Transfer Procedures incomplete - 33 CFR155.750
Condition: Unknown
Due 9 December 1999
Resolved 12 December 1999
Fire Fighting
Issued 9 December 1999
Resolved
Initial Fire Drill performed unsatisfactorily, second drill sat - SOLAS 74 Am, III/18
Condition: Unknown
Due 9 December 1999
Resolved 12 December 1999
Navigation
Issued 9 December 1999
No resolution recorded
Vessel must conduct pre-arrival tests - 33 CFR 164.25
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Navigation
Issued 9 December 1999
No resolution recorded
Correct Maneuvering Fact Sheet for bow thruster and warning statement - 33 CFR 164.35 (a)
Condition: Unknown
Due 13 December 1999 — due date passed with no resolution recorded
Construction/Loadline
Issued 14 March 1999
Resolved
Several dogs missing/broken on hatch located on focsle. Vessel is to correct prior to next U.S. port.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Engineering
Issued 14 March 1999
Resolved
Oily Water Separator is inoperable. Vessel is to repair prior to next U.S. port.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Electrical
Issued 14 March 1999
Resolved
Protective guards missing from overhead lighting in crew accomodation and forward hawser locker. Vessel is to correct prior to next U.S. port.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Lifesaving
Issued 14 March 1999
Resolved
Lifeboat embarkation lighting frozen in place and unable to pivot. Vessel to correct prior to next U.S. port.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Documentation
Issued 14 March 1999
Resolved
SOPEP missing Guam points of contact. Vessel to correct prior to next U.S.port.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Documentation
Issued 14 March 1999
Resolved
Vessel's bunker pipeline pressure tests not being recorded. Vessel to correct prior to next U.S. port.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Fire Fighting
Issued 16 August 1998
Resolved
Found that the door to CO2 room opens inward. Door should open outward in accordance with Solas 74 unammended II-2/5.1.13. Vsl shall correct this deficiency prior to next U.S. port.
Condition: Unknown
Due 7 September 1998
Resolved 7 September 1998
Engineering
Issued 16 August 1998
Resolved
Found that flame Screens missing from fuel oil tanks. Vsl shall install flame screens in accordance with Solas 74 unammended II-2/2. Vsl shall correct this deficiency prior to next U.S. port.
Condition: Unknown
Due 7 September 1998
Resolved 7 September 1998
Electrical
Issued 21 May 1998
Resolved
Lighting fixtures were missing covers and or guards. Areas of concern are:passageway to the engineroom, above emergency air compressor, and above lube settling tank. _x001C_ SOLAS 74 II-1/45.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Fire Fighting
Issued 21 May 1998
Resolved
While conducting a deck walk it was found that the fire hose boexes (stations) did not have the proper fire fighting nozzles. Nozzles found atthe stations, with the exception of two, were suicide nozzles._x001C_ SOLAS 74 (amended) II-2/21.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 21 May 1998
Resolved
Visual inspections of survival craft/rescue boats are being conducted monthly rather than mandated weekly frequency._x001C_ _x001C_ SOLAS 74 (amended) III/19.6.1
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 21 May 1998
Resolved
Operation of lifeboat engine was not being conducted weekly and logged as required._x001C_ _x001C_ SOLAS 74 (amended) III/19.6.2
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 21 May 1998
Resolved
Vessel did not test general alarm weekly as required._x001C_ _x001C_ _x001C_ SOLAS 74 (amended) III/19.6.3
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Navigation
Issued 21 May 1998
Resolved
The maneuvering fact sheet was missing bnow thruster information, and the warning statement._x001C_ _x001C_ SOLAS 74 (amended) V/12.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Documentation
Issued 21 May 1998
Resolved
Shipboard oil pollution emergency plan was outdated; e.g. contact information and not approved for the current owner/operator.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 21 May 1998
Resolved
The port lifeboat's center 3 wooden seats are deteriorated and in need of repair or replacement._x001C_ _x001C_ SOLAS 74 III/5 and I/11.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Accommodation/Occupational Safety
Issued 21 May 1998
Resolved
Vessel was unable to provide satisfactory evidence that plastic waste was being properly disposed of in nonadherence with 33 CFR 151.67 and MARPOL 73/78 V/3(1).
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 21 May 1998
Resolved
Port lifeboat embarkation ladder is ofinsufficient length; e.g. ladder did not reach the water during light condition of vessel.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Engineering
Issued 29 August 1997
Resolved
Oily water separator inoperable due to bad fuse. Corrected on scene.
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Lifesaving
Issued 29 August 1997
Resolved
Inadequate water supply on starboard lifeboat. SOLAS III/11.
Condition: Unknown
Due 30 August 1997
Resolved 6 October 1997
Lifesaving
Issued 29 August 1997
Resolved
PD-RC power distribution board deck locker used to inappropriately stow ships hazardous stores, such as flammable/combustable liquids and compressed gases thereby being in a condition of non-maintenance of the fullest practicable degree of fire protection.
Condition: Unknown
Due 30 August 1997
Resolved 6 October 1997
Fire Fighting
Issued 29 August 1997
Resolved
02 deck fire stations missing firefighting nozzles.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Electrical
Issued 29 August 1997
Resolved
Electrical lights in various areas,e.g; starboard lifeboat deck, A B oiler stateroom, and other internal spaces, not properly wired and/or protected to eliminate danger of injury during ordinary andling/usage. SOLAS 74 II- 1/27.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Accommodation/Occupational Safety
Issued 29 August 1997
Resolved
Hospital space is inappropriately being used as an equipment stowage area; e.g. deep chest freezer and numerous electronic consumer goods. ILO 147
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Fire Fighting
Issued 29 August 1997
Resolved
Firesystem piping IWO port side aft deck house holed, thereby reducing firefighting capabilities. SOLAS 74 II-2/21.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 29 August 1997
Resolved
Not all PFD's are equipped with whistles. SOLAS 74 III/22.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Deck/Cargo
Issued 29 August 1997
Resolved
Mooring winch foundations, port and starboard aft main deck, severely deteriorated as a result of corrosion. ICLL66.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Fire Fighting
Issued 29 August 1997
Resolved
Fire system piping support brackets deteriorated iwo of starboard hatch no.14-15. SOLAS 74 II-2/15.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 29 August 1997
Resolved
At next U.S. port conduct boat drill. None conducted at Guam due to inclement weather.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998