MAURY USCG vessel records
← All vessels

INVESTIGATOR

Built
1981
Last inspected
13 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCQ4938
411751
Flag
UNITED STATES
Maury page id
psix-411751

Documentation record

Registered dimensions (L × B × D)36.0 ft × 15.0 ft × 6.0 ft
Registered tonnagegross 21 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDAVID A LAUX BOATBUILDERS · GEORGETOWN, DE, UNITED STATES · built 1981
Hull materialAluminum
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portPORT CLINTON, OH
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 14 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

13 April 2026 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8346931
22 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8191925
12 November 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8108537
17 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7896947
18 April 2023 Internal Structural Exam · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7675424
4 May 2022 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7444008
26 April 2022 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7439241
15 April 2021 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7174080
12 May 2020 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6951973
28 February 2020 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6917633
24 April 2019 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6670859
25 April 2018 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6399298
19 April 2017 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6132197
18 April 2016 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5854102

Deficiency record · 16

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 April 2026 Resolved
(a)Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative (c)The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel has not been conducting or logging monthly tests. Tested and logged while onboard. 46 CFR 185.728 (a)(c)
Action required: 10 - Deficiency Rectified
Resolved 14 April 2026
Resolution: Tested and logged while onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2026 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (ii)Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.(iv)The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel has not been conducting or logging monthly fire extinguisher inspections. Inspected and logged while onboard. 46 CFR 176.810(b)(ii)(iv)
Action required: 10 - Deficiency Rectified
Resolved 14 April 2026
Resolution: Inspected and logged while onboard.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 April 2026 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. (f)Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Vessel has not been logging drills. Ran man overboard and fire drill underway. Logged. 46 CFR 185.520(a)(f)
Action required: 10 - Deficiency Rectified
Resolved 14 April 2026
Resolution: Ran man overboard and fire drill underway. Logged.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 May 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 19 May 2022
Resolution: New EPIRB was purchased and properly installed on the vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 April 2022 Resolved
EPIRB Battery found to be expired as of 2021. Vessel restricted to operations within 3 miles from Coastline on the Great Lakes. Replace battery per manufacturers specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 4 May 2022
Resolution: O/O tried to replace the battery with an aftermarket, not approved battery. A new 835 was issued requiring replacement EPIRB or approved battery to be installed and manufacturer's tests to be performed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 April 2022 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. EPIRB hydrostatic release marked for 3 year to expire in 2025. Unit will expire in 2024. [name withheld] release unit with the correct expiration date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 19 May 2022
Resolution: Proper year was marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 April 2022 Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose which: Do not rely on spring tension of the clamp for compressive force. All flexible cooling water hoses should be installed with two hose clamps on each end of the hose before and after strainer for MDE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 19 May 2022
Resolution: Felx hose for MDE was double clampd on each end before nad after the strainer.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 April 2022 Resolved
STBD Navigation light did not activate upon operation of switch. Light would illuminate after housing was moved. Repair STBD Navigation light so that it remains illuminated when activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 19 May 2022
Resolution: Nav light operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2021 Resolved
14 Lifejackets were removed from the vessel. Lifejackets were worn/damaged and no longer serviceable. Manning will be reduced from 19 passengers to 5 passengers and 2 crew until new lifejackets are available.
Action required: 705 - Other - as specified
Resolved 16 April 2021
Resolution: Vessel provided 14 new Type I PFD's with reflective tape and proper labeling.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 May 2020 Resolved
Emergency Fuel Shut-off was not labeled. Vessel owner shall label the location of the Emergency fuel shut-off location on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2020
Resolved 21 May 2020
Resolution: Vessel operator sent photo of the emergency shut off placard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 February 2020 Resolved
Shaft Bearing (Cutlass) worn past 50%. Vessel owner shall replace the bearing prior to vessel being placed back into service from DryDock.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2020
Resolved 20 March 2020
Resolution: Vessel replaced shaft bearing
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 February 2020 Resolved
Weld on the Star board side approx. 16" aft of the bow the weld is cracked.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2020
Resolved 19 April 2021
Resolution: Repair made to satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 February 2020 Resolved
Welds at collision bulk head fram cracked. Vessel owner shall repair prior to dry dock completion.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2020
Resolved 20 March 2020
Resolution: Welds repaired and inspected
Construction/Loadline › Hull › Transverse Frame
Issued 19 April 2017 Resolved
Frame just under helm fractured at intersection of floor to side frame, drill stop for temp repair effect permanent repair at dry dock in winter
Action required: 705 - Other - as specified
Due 2 October 2017
Resolved 25 April 2018
Resolution: Frame repaired.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 18 April 2016 Resolved
The buoyant apparatus waterlight lanyard was found in deteriorated condition. Replace lanyard IAW 46 CFR 180.175(f)(4).
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 28 April 2016
Resolution: Waterlight lanyard was replaced as original; all sat.
Lifesaving › Buoyant Apparatus › Painter
Issued 18 April 2016 Resolved
The buoyant apparatus painter was found in deteriorated condition. Replace painter IAW 46 CFR 180.175(f)(3).
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 28 April 2016
Resolution: Painter was replaced as original; all sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.