MAURY USCG vessel records Sign in
← All vessels

INVESTIGATOR

INVESTIGATOR is a 1981 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 1995, most recently in April 2026, along with 38 deficiencies, 1 operational control and 1 casualty investigation in 2008.

Records from 1995 to 2026. Most recent: inspection, 13 April 2026.

Built
1981
Last inspected
13 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCQ4938
411751
Flag
UNITED STATES
367009260
Maury page id
psix-411751

Inspections, by type

…with no type recorded1
Years with a record 27 calendar years (1995–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.0 ft × 15.0 ft × 6.0 ft
Registered tonnagegross 21 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDAVID A LAUX BOATBUILDERS · GEORGETOWN, DE, UNITED STATES · built 1981
Hull materialAluminum
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portPORT CLINTON, OH
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCQ4938MMSI 367009260 · active · compulsorily equipped · granted 20 February 2025, expires 28 March 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 37

13 April 2026 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8346931
22 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8191925
12 November 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8108537
17 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7896947
18 April 2023 Internal Structural Exam · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7675424
4 May 2022 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7444008
26 April 2022 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7439241
15 April 2021 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7174080
12 May 2020 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6951973
28 February 2020 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6917633
24 April 2019 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6670859
25 April 2018 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6399298
19 April 2017 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6132197
18 April 2016 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5854102
8 March 2010 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3691598
8 July 2009 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3527921
6 April 2009 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3447012
17 May 2008 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3240689
14 April 2008 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3183601
11 July 2007 Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2993728
27 April 2007 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2917075
30 March 2007 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2898336
23 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2656783
7 April 2006 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2619056
27 April 2005 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2343830
23 February 2005 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2295342
27 April 2004 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2049253
24 April 2003 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1779937
25 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1598172
13 March 2001 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1397595
5 April 2000 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1457776
3 March 2000 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1384387
14 April 1999 Plan Review "T" Boat · Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 787211
13 March 1998 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1386217
20 March 1997 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1442533
8 April 1996 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1079470
31 March 1995 Hull Examination · Initial Certification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1396248

Deficiency record · 38

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 April 2026 Resolved
(a)Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative (c)The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel has not been conducting or logging monthly tests. Tested and logged while onboard. 46 CFR 185.728 (a)(c)
Action required: 10 - Deficiency Rectified
Resolved 14 April 2026
Resolution: Tested and logged while onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2026 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (ii)Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.(iv)The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel has not been conducting or logging monthly fire extinguisher inspections. Inspected and logged while onboard. 46 CFR 176.810(b)(ii)(iv)
Action required: 10 - Deficiency Rectified
Resolved 14 April 2026
Resolution: Inspected and logged while onboard.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 April 2026 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. (f)Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Vessel has not been logging drills. Ran man overboard and fire drill underway. Logged. 46 CFR 185.520(a)(f)
Action required: 10 - Deficiency Rectified
Resolved 14 April 2026
Resolution: Ran man overboard and fire drill underway. Logged.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 May 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 19 May 2022
Resolution: New EPIRB was purchased and properly installed on the vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 April 2022 Resolved
EPIRB Battery found to be expired as of 2021. Vessel restricted to operations within 3 miles from Coastline on the Great Lakes. Replace battery per manufacturers specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 4 May 2022
Resolution: O/O tried to replace the battery with an aftermarket, not approved battery. A new 835 was issued requiring replacement EPIRB or approved battery to be installed and manufacturer's tests to be performed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 April 2022 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. EPIRB hydrostatic release marked for 3 year to expire in 2025. Unit will expire in 2024. [name withheld] release unit with the correct expiration date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 19 May 2022
Resolution: Proper year was marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 April 2022 Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose which: Do not rely on spring tension of the clamp for compressive force. All flexible cooling water hoses should be installed with two hose clamps on each end of the hose before and after strainer for MDE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 19 May 2022
Resolution: Felx hose for MDE was double clampd on each end before nad after the strainer.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 April 2022 Resolved
STBD Navigation light did not activate upon operation of switch. Light would illuminate after housing was moved. Repair STBD Navigation light so that it remains illuminated when activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 19 May 2022
Resolution: Nav light operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2021 Resolved
14 Lifejackets were removed from the vessel. Lifejackets were worn/damaged and no longer serviceable. Manning will be reduced from 19 passengers to 5 passengers and 2 crew until new lifejackets are available.
Action required: 705 - Other - as specified
Resolved 16 April 2021
Resolution: Vessel provided 14 new Type I PFD's with reflective tape and proper labeling.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 May 2020 Resolved
Emergency Fuel Shut-off was not labeled. Vessel owner shall label the location of the Emergency fuel shut-off location on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2020
Resolved 21 May 2020
Resolution: Vessel operator sent photo of the emergency shut off placard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 February 2020 Resolved
Shaft Bearing (Cutlass) worn past 50%. Vessel owner shall replace the bearing prior to vessel being placed back into service from DryDock.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2020
Resolved 20 March 2020
Resolution: Vessel replaced shaft bearing
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 February 2020 Resolved
Weld on the Star board side approx. 16" aft of the bow the weld is cracked.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2020
Resolved 19 April 2021
Resolution: Repair made to satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 February 2020 Resolved
Welds at collision bulk head fram cracked. Vessel owner shall repair prior to dry dock completion.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2020
Resolved 20 March 2020
Resolution: Welds repaired and inspected
Construction/Loadline › Hull › Transverse Frame
Issued 19 April 2017 Resolved
Frame just under helm fractured at intersection of floor to side frame, drill stop for temp repair effect permanent repair at dry dock in winter
Action required: 705 - Other - as specified
Due 2 October 2017
Resolved 25 April 2018
Resolution: Frame repaired.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 18 April 2016 Resolved
The buoyant apparatus waterlight lanyard was found in deteriorated condition. Replace lanyard IAW 46 CFR 180.175(f)(4).
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 28 April 2016
Resolution: Waterlight lanyard was replaced as original; all sat.
Lifesaving › Buoyant Apparatus › Painter
Issued 18 April 2016 Resolved
The buoyant apparatus painter was found in deteriorated condition. Replace painter IAW 46 CFR 180.175(f)(3).
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 28 April 2016
Resolution: Painter was replaced as original; all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 April 2009 Resolved
Provide proper supports on wiring in engine compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 8 July 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 April 2009 Resolved
Provide battery box for auxiliary battery
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 8 July 2009
Fire Fighting › Fire Main › Material
Issued 6 April 2009 Resolved
Remove installed garden type hose and replace with approved piping.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 8 July 2009
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 April 2009 Resolved
Conduct man overboard and fire drill
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 8 July 2009
Lifesaving › Buoyant Apparatus › Lifeline
Issued 30 March 2007 Resolved
Repair D-ring on Bouant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2007
Resolved 27 April 2007
Resolution: Vessels reps repaired damaged D ring on the B/A, all sat.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 7 April 2006 Resolved
Attach double hose clamps to three cooling water hoses.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 18 May 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 27 April 2005 Resolved
Need to replace the retro on the tops of two adults life jackets.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 27 April 2005
Resolution: Replaced the retro on the two life jackets.
Fire Fighting › Fire Bucket › Stenciling
Issued 27 April 2005 Resolved
Need to stensil the 3 fire buckets on board.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 27 April 2005
Resolution: The crew stensiled all the buckets while we were still on board.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 April 2005 Resolved
Vessels compass light does not turn on, the bulb looks sat.
Condition: Placed in Improper Service
Due 27 May 2005
Resolved 11 May 2005
Engineering › Steering Gear System › Rudder
Issued 23 February 2005 Resolved
Several cracks were found on the rudder along existing welds.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2005
Resolved 15 March 2005
Resolution: Rudder was welded using proper metal fillers and extra stiffeners were added to alleviate future stress cracks.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 February 2005 Resolved
Wiring was suspended in overhead of engine compartment with plastic ties.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2005
Resolved 27 April 2005
Resolution: Crew installed a hangor in the engine room with a steel/rubber wire tie to hang the wire harness. Looks sat.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 18 February 2005 Resolved
Hydraulic reservoir/seal ruptured during winter freeze placing all of the oil into the bilge.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2005
Resolved 27 April 2005
Resolution: Repaired the leak with sat results.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 February 2005 Resolved
Batteries did not have straps to hold them in palce.
Condition: Improper Installation
Due 27 April 2005
Resolved 27 April 2005
Resolution: Installed a strap for the batteries, looks sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 February 2005 Resolved
Exhaust lagging on turbocharger is wasted and worn. Replacement is needed as well as all the piping between the engine and the water injection point surrounding the turbo charger.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2005
Resolved 27 April 2005
Resolution: Replaced all the lagging on the turbo exhaust snail and the exhaust pipe that was missing lagging below the turbo.
Communications › Radio Communications
Issued 27 April 2004 Resolved
Ensure vessel's radios are serviced as per the Great Lakes Radio agreement.
Condition: Improper/Lack of Maintenance
Due 27 May 2004
Resolved 10 June 2004
Electrical › Electric Supply System (service)
Issued 27 April 2004 Resolved
Properly wire shore tie and A/C battery charger. LEGACY COMPONENT DESC: Battery Charger
Condition: Improper/Lack of Maintenance
Due 27 May 2004
Resolved 10 June 2004
Electrical › Electric Supply System (service)
Issued 27 April 2004 Resolved
Properly secure hanging wire in forward cabin.
Condition: Improper/Lack of Maintenance
Due 27 May 2004
Resolved 10 June 2004
Engineering › Steering Gear System
Issued 27 April 2004 Resolved
Tighten leaking hydraulic steering pump fittings. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 27 May 2004
Resolved 27 April 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 27 April 2004 Resolved
Replace or repair engine RPM gauge. LEGACY COMPONENT DESC: RPM Gauge
Condition: Unknown
Due 27 May 2004
Resolved 10 June 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 24 April 2003 Resolved
Removed one life jacket from service due to large gouge in head hole area.
Due 24 April 2003
Resolved 24 April 2003
Navigation
Issued 5 April 2000 Resolved
REPAIR OR REPLACE INOP HORN.
Condition: Unknown
Due 20 April 2000
Resolved 25 April 2000
Lifesaving
Issued 5 April 2000 Resolved
REPLACE TWO BROKEN CABIN WINDOWS.
Condition: Unknown
Due 20 April 2000
Resolved 18 April 2000

Casualty record · 1

17 May 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3240689
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.