MAURY USCG vessel records
← All vessels

DOLE AFRICA

Built
1995
Last inspected
9 January 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 January 2026
…with no type recorded6
Operational controls 1 with no removal date recorded
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9046538
411809
Flag
LIBERIA
Maury page id
psix-411809

Documentation record

Tonnage as PSIX records it10584 - Convention (Subpart B), Gross Ton
5060 - Convention (Subpart B), Net Ton
10282 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; 1 operational control with no removal date recorded; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

9 January 2026 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8291245
5 December 2025 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8276841
2 June 2025 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8145932
4 November 2024 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8026414
10 July 2024 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7954991
6 May 2024 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7903817
9 October 2023 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7804164
23 March 2023 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7654282
30 January 2023 Appeal
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7715266
27 October 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7584682
9 September 2022 Appeal
Administrative · Commandant (CG-CVC) · Activity 7596478
4 September 2022 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7547020
12 August 2022 MARPOL Annex I Examination · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7530979
12 August 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7531706
8 April 2022 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7424156
25 August 2021 PSC B · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7292136
29 January 2021 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7129681
15 July 2020 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7002531
28 April 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6945483
22 April 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6942228
31 January 2020 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6900158
9 January 2020 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6882912
16 May 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6685656
13 March 2019 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6639884
21 February 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6627784
7 February 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6348332
24 November 2017 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6310607
23 November 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6044230
26 May 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5887604
12 May 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5871672

Deficiency record · 15

03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 September 2022 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed. The bottom knife edge of the paint locker door was found corroded and no longer creating a weathertight seal. 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2022
Resolved 23 September 2022
Resolution: Class follow up report clears deficiency.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 August 2022 Resolved
Every ship of 400 gross tons and above shall be provided with an Oil Record Book Part I which shall be in the form specified in Appendix III of MARPOL Annex I. The ship's Oil Record Book Part I was missing the required (Code C 11) weekly soundings of oil residues (sludge) tanks listed in the IOPP. MARPOL 73/78 (2020) Annex I 17.1 (MARPOL 73/78 (2020)Annex I 17.1 APPENDIX III C.11)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 28 September 2022
Resolution: Received follow-up report showing deficiency has been cleared. See RINA PSC Follw-Up Report dated 04SEP22 (w/in documents).
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 14 August 2022 Resolved
Oil filtering equpment leading to the overboard discharge was found with an oil like substance within it. Conduct thorough cleaning of contaminated piping.
Action required: 10 - Deficiency Rectified
Resolved 16 August 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 August 2022 Resolved
Structural fire protection missing on machinery space boundary and the Tk 18 PS.
Action required: 10 - Deficiency Rectified
Resolved 16 August 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 August 2022 Resolved
The supply valve fitted on the the incinerator diesel tank was leaking from the valve stem.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2022
Resolution: Leak was fixed.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 12 August 2022 Resolved
Any ship of 10,000 gross tons and above shall be fitted with oil filtering equipment that is provided with arrangements to insure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 ppm.During testing of the OWS the sampling/freshwater manual three-way valve was positioned in a way that there was not flow of sampling water or fresh water through the OCM, thus the automatic three way valve would not activate and deliver the oily water back to the bilge tank when required. MARPOL I/14.7
Action required: 30 - Ship detained
Due 12 August 2022
Resolved 16 August 2022
14 - Pollution Prevention › 141 - MARPOL Annex I › Pollution report-MARPOL Annex I
Issued 12 August 2022 Resolved
The Oil Record Book Part I shall be kept in such place as to be readily available for inspection at all reasonable times and shall be kept on board the ship. It shall be preserved for a period of three years after the last entry has been made. August 2019 – January 2020 Oil Record Book was not found onboard. MARPOL I/17.6
Action required: 30 - Ship detained
Due 12 August 2022
Resolved 13 August 2022
Resolution: Vessel Chief Engineer located the record book after the intial inspection and the first inspection team had departed the vessel.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 12 August 2022 Resolved
Each incinerator on a ship constructed on or after 1 January 2000 shall meet the requirements in Appendix IV to this Annex. Each incinerator approved by the administration taking into account the standard specifications found in MEPC.76 (40). The aforementioned MEPC states that an incinerator walls are to be protected with insulated fire bricks / refractory and a cooling system. PSCO found that the refractory bricks were missing and others were found deteriorated. MARPOL VI/16.6.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 16 August 2022
Resolution: Fixed leak and patched area with cement
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 August 2022 Resolved
The following Protection Systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarms systems. PSCO found that the fire smoke detectors above the oily water separator has been temporary repaired and held in place by the use of electrical tape. 74 SOLAS 14 II-2 / 14.2.1.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 13 August 2022
Resolution: A new smoke detector has been installed and tested satisfactorily.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 12 August 2022 Resolved
The Oil Record Book Part I shall be completed on each occasion whenever bilge water which has accumulated in machinery spaces is disposed of. The PSCOs noted that the Oil Record Book Part I is missing the bilge water transfer operations from the engine room bilge wells and the recess under the main engine to bilge water holding tank no. 5. MARPOL 73/78 (2020) Annex I 17.2 Specifically, (MARPOL 73/78 (2020) Annex I 17.1 Appendix III D. 13
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 28 September 2022
Resolution: Received follow-up report showing deficiency has been cleared. See RINA PSC Follw-Up Report dated 04SEP22 (w/in documents).
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 January 2020 Resolved
The steering gear compartment shall be provided with suitable arrangements to ensure working access to steering gear machinery and controls. The arrangements shall include handrails and gratings or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. The nonslip surface in the steering gear compartment has worn down making it no longer suitable in the event of a hydraulic fluid leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 31 January 2020
Resolution: Statement from DNV-GL received rectifying the deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 February 2019 Resolved
Where gaseous fuel is used for domestic purposes the arrangements for the storage, distribution and utilization of the fuel shall be such that, having regard to the hazards of fire and explosion which the use of such fuel may entail, the safety of the ship and the persons on board is preserved. Multiple oxygen and acetylene cylinders were over running the assigned space, and not bracketed. 97 SOLAS Ch. II-2/Reg. 51
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 March 2019
Resolution: pictures and documents uploaded in docs section
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 21 February 2019 Resolved
Every ship of 100 gross tonnage and above, shall carry a Garbage Management Plan which the crew shall follow. This plan shall provide written procedures for minimizing, collecting,storing, processing, and disposing of garbage, including the use of equipment on board. Garbage bags were found stacked in incinerator space, and not in proper recepticles, as per Garbage Management Plan. MARPOL V/Reg. 10.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 March 2019
Resolution: pictures and documents uploaded in docs section
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 November 2016 Resolved
Alleyways, stairways, and exists giving access to the muster stations shall be lighted. Port side emergency lighting is not working.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2016
Resolved 23 November 2016
Resolution: Cleared by SecSJ Duty Marine Inspector ([name withheld]).
Lifesaving › Lifeboat › Hatches
Issued 12 May 2016 Resolved
0610-Every totally enclosed lifeboat shall be provided with a rigid watertight enclosure so arranged that hatches can be closed to make watertight. Aft door seal on free fall lifeboat was detached. Vessel made temporary repairs until new seal can be purchased. 74SOLAS(09)III/34, LSA Code 4.6.2.2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 26 May 2016
Resolution: Received email from Class attesting to the proper repairs of the rear hatch seal on free fall lifeboat.

Ownership record