← All vessels
DOLE AFRICA
DOLE AFRICA is a 1995 freight ship. The Coast Guard has recorded 59 inspections since 1995, most recently in January 2026, along with 23 deficiencies and 4 operational controls, 1 with no removal date recorded.
Records from 1995 to 2026. Most recent: inspection, 9 January 2026.
- Built
- 1995
- Last inspected
- 9 January 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 23 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9046538 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6FS3
411809
Flag
LIBERIA
—
Maury page id
psix-411809
Inspections, by type
…with no type recorded18
Years with a record
29 calendar years (1995–2026)
The 59 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it10584 - Convention (Subpart B), Gross Ton
5060 - Convention (Subpart B), Net Ton
10282 - Dead Weight, Ton
5060 - Convention (Subpart B), Net Ton
10282 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 59
9 January 2026
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8291245
5 December 2025
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8276841
2 June 2025
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8145932
4 November 2024
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8026414
10 July 2024
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7954991
6 May 2024
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7903817
9 October 2023
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7804164
23 March 2023
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7654282
30 January 2023
Appeal
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7715266
27 October 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7584682
9 September 2022
Appeal
Administrative · Commandant (CG-CVC) · Activity 7596478
4 September 2022
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7547020
12 August 2022
MARPOL Annex I Examination · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7530979
12 August 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7531706
8 April 2022
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7424156
25 August 2021
PSC B · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7292136
29 January 2021
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7129681
15 July 2020
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7002531
28 April 2020
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6945483
22 April 2020
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6942228
31 January 2020
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6900158
9 January 2020
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6882912
16 May 2019
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6685656
13 March 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6639884
21 February 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6627784
7 February 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6348332
24 November 2017
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6310607
23 November 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6044230
26 May 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5887604
12 May 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5871672
28 August 2015
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5226717
22 August 2014
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4961591
18 July 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4381926
29 December 2011
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4215526
8 December 2011
MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4204162
11 November 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3889379
13 January 2008
MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · ILO-147 Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3129681
12 January 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2854644
15 September 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2779190
5 January 2006
Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2561331
3 March 2005
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2300127
10 January 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2272143
8 December 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2255648
17 June 2004
ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2087292
6 November 2003
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1943307
3 October 2001
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1077157
26 September 2001
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1077112
7 September 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 294376
30 August 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 281716
11 August 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 821598
5 July 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1051490
19 May 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1049488
6 May 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 428454
13 March 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 413731
22 February 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 400453
26 August 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 394704
7 February 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 387727
24 February 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 375477
3 February 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 374853
Deficiency record · 23
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 September 2022
Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed. The bottom knife edge of the paint locker door was found corroded and no longer creating a weathertight seal. 50ac
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 August 2022
Resolved
Every ship of 400 gross tons and above shall be provided with an Oil Record Book Part I which shall be in the form specified in Appendix III of MARPOL Annex I. The ship's Oil Record Book Part I was missing the required (Code C 11) weekly soundings of oil residues (sludge) tanks listed in the IOPP. MARPOL 73/78 (2020) Annex I 17.1 (MARPOL 73/78 (2020)Annex I 17.1 APPENDIX III C.11)
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 14 August 2022
Resolved
Oil filtering equpment leading to the overboard discharge was found with an oil like substance within it. Conduct thorough cleaning of contaminated piping.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 August 2022
Resolved
Structural fire protection missing on machinery space boundary and the Tk 18 PS.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 August 2022
Resolved
The supply valve fitted on the the incinerator diesel tank was leaking from the valve stem.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 12 August 2022
Resolved
Any ship of 10,000 gross tons and above shall be fitted with oil filtering equipment that is provided with arrangements to insure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 ppm.During testing of the OWS the sampling/freshwater manual three-way valve was positioned in a way that there was not flow of sampling water or fresh water through the OCM, thus the automatic three way valve would not activate and deliver the oily water back to the bilge tank when required.
MARPOL I/14.7
14 - Pollution Prevention › 141 - MARPOL Annex I › Pollution report-MARPOL Annex I
Issued 12 August 2022
Resolved
The Oil Record Book Part I shall be kept in such place as to be readily available for inspection at all reasonable times and shall be kept on board the ship. It shall be preserved for a period of three years after the last entry has been made. August 2019 – January 2020 Oil Record Book was not found onboard.
MARPOL I/17.6
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 12 August 2022
Resolved
Each incinerator on a ship constructed on or after 1 January 2000 shall meet the requirements in Appendix IV to this Annex. Each incinerator approved by the administration taking into account the standard specifications found in MEPC.76 (40). The aforementioned MEPC states that an incinerator walls are to be protected with insulated fire bricks / refractory and a cooling system. PSCO found that the refractory bricks were missing and others were found deteriorated.
MARPOL VI/16.6.1
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 August 2022
Resolved
The following Protection Systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarms systems. PSCO found that the fire smoke detectors above the oily water separator has been temporary repaired and held in place by the use of electrical tape.
74 SOLAS 14 II-2 / 14.2.1.1.2
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 12 August 2022
Resolved
The Oil Record Book Part I shall be completed on each occasion whenever bilge water which has accumulated in machinery spaces is disposed of. The PSCOs noted that the Oil Record Book Part I is missing the bilge water transfer operations from the engine room bilge wells and the recess under the main engine to bilge water holding tank no. 5. MARPOL 73/78 (2020) Annex I 17.2 Specifically, (MARPOL 73/78 (2020) Annex I 17.1 Appendix III D. 13
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 January 2020
Resolved
The steering gear compartment shall be provided with suitable arrangements to ensure working access to steering gear machinery and controls. The arrangements shall include handrails and gratings or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. The nonslip surface in the steering gear compartment has worn down making it no longer suitable in the event of a hydraulic fluid leak.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 February 2019
Resolved
Where gaseous fuel is used for domestic purposes the arrangements for the storage, distribution and utilization of the fuel shall be such that, having regard to the hazards of fire and explosion which the use of such fuel may entail, the safety of the ship and the persons on board is preserved. Multiple oxygen and acetylene cylinders were over running the assigned space, and not bracketed. 97 SOLAS Ch. II-2/Reg. 51
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 21 February 2019
Resolved
Every ship of 100 gross tonnage and above, shall carry a Garbage Management Plan which the crew shall follow. This plan shall provide written procedures for minimizing, collecting,storing, processing, and disposing of garbage, including the use of equipment on board. Garbage bags were found stacked in incinerator space, and not in proper recepticles, as per Garbage Management Plan. MARPOL V/Reg. 10.2
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 November 2016
Resolved
Alleyways, stairways, and exists giving access to the muster stations shall be lighted. Port side emergency lighting is not working.
Lifesaving › Lifeboat › Hatches
Issued 12 May 2016
Resolved
0610-Every totally enclosed lifeboat shall be provided with a rigid watertight enclosure so arranged that hatches can be closed to make watertight. Aft door seal on free fall lifeboat was detached. Vessel made temporary repairs until new seal can be purchased.
74SOLAS(09)III/34, LSA Code 4.6.2.2.
Engineering › Freshwater Generation System › Ejector
Issued 8 December 2011
Resolved
Brine discharge valve from water maker is corroded and patched with tape below the waterline.
Engineering › Diesel Engine (propulsion-direct drive) › Crosshead Assembly
Issued 8 December 2011
Resolved
The port-aft MDE stay-bolt is broken.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 8 December 2011
Resolved
Incinerator sludge pump was inoperable, though endorsed on the IOPP.
Engineering › Bilge Water Management System › Piping
Issued 8 December 2011
Resolved
Organization shall verify proper OWS system configuration and design, and endorse drawings. PSCO observed recirculation line going to tank #5 not listed on piping diagramfor engine room.
Engineering
Issued 3 February 1995
Resolved
NO OIL TRANSFER PROCEDURES.
Fire Fighting
Issued 3 February 1995
Resolved
EVERY FIRE STATION DOES NOT CONTAIN SPANNER WRENCHES._x001C_ SOLAS CH II-2, REG 4.7.1
Lifesaving
Issued 3 February 1995
Resolved
VESSEL REQUIRED TWO LIFEBOUYS WITH AT LEAST 30 METERS OF LINE. AT TIME OF BOARDING ONLY ONE ONBOARD._x001C_ SOLAS CH III, REG 7.1.2
Unknown
Issued 3 February 1995
Resolved
REPAIR HYDRAULIC LEAK ON PORT BOAT DAVIT._x001C_ COTP.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.