HARRAHS NORTH STAR

HARRAHS NORTH STAR is a 1994 passenger vessel (inspected). The Coast Guard has recorded 132 inspections since 1994, most recently in October 2014, along with 286 deficiencies and 2 casualty investigations between 2010 and 2014.

Records from 1994 to 2014. Most recent: inspection, 27 October 2014.

Built
1994
Last inspected
27 October 2014
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCP2205
411876
Flag
UNITED STATES
366993030 (licence lapsed)
Maury page id
psix-411876

Inspections, by type

…with no type recorded42
Years with a record 18 calendar years (1994–2014)
The 132 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)259.3 ft × 78.0 ft × 14.0 ft
Registered tonnagegross 2,170 / net 1,755
ITC dimensions (L × B × D)259.3 ft × 78.0 ft × 14.0 ft
ITC tonnagegross 7,291 / net 2,187
BuilderBENDER SHPBLDG & REPR CO · MOBILE, AL, UNITED STATES · built 1994
Hull materialSteel
PropulsionCombination Types
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORTH KANSAS CITY, MO
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1755 - Regulatory (Subpart C or D), Net Ton
2187 - Convention (Subpart B), Net Ton
2170 - Regulatory (Subpart C or D), Gross Ton
7291 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCP2205MMSI 366993030 · cancelled · compulsorily equipped · granted 29 November 2014, cancelled 20 April 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 132

27 October 2014 Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5012964
1 October 2014 Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4997241
1 October 2014 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5006195
24 August 2014 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4966346
13 August 2014 Type not recorded
No type recorded · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 4953995
30 May 2014 Administrative Inspection · Annual Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4893141
17 July 2012 Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4381650
17 July 2012 MTSA Verification · Administrative Inspection · COI Inspection · Underwater Inspection in lieu of Drydock · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4381717
13 January 2012 Administrative Inspection · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4224576
22 August 2011 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4124202
26 July 2011 COI Inspection · MTSA Verification · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4095677
15 February 2011 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3945833
16 February 2010 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3678580
16 February 2010 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3680980
12 May 2009 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3467261
12 February 2009 Re-Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3416827
10 November 2008 Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3370604
7 August 2008 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3292163
13 May 2008 Re-Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3295408
21 February 2008 Deadweight Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3152235
20 February 2008 Re-Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3150638
21 December 2007 Plan Review (Other than "T")
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3119314
19 November 2007 Re-Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3101065
18 October 2007 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3082548
26 July 2007 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3007985
21 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2969319
12 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2959242
22 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2936290
23 March 2007 In-Service Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2893631
8 March 2007 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2884060
12 February 2007 Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2869894
14 August 2006 COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2744017
6 June 2006 Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2672382
31 May 2006 Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2666398
22 February 2006 Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2590038
18 November 2005 Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2537205
17 August 2005 MARPOL Annex V Examination · COI Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2466128
6 June 2005 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2382271
7 March 2005 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2305675
23 November 2004 Re-Inspection · MTSA Verification
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2249719
27 August 2004 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2181036
2 June 2004 Quarterly Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2086662
1 March 2004 Quarterly Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2015850
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977885
25 November 2003 Quarterly Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1955154
28 August 2003 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1889491
11 June 2003 Quarterly Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1815032
11 March 2003 Quarterly Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1756755
16 December 2002 Quarterly Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1719592
5 September 2002 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1676695
18 June 2002 Quarterly Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1633033
31 May 2002 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1629091
12 March 2002 Quarterly Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1493184
6 March 2002 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1494120
28 December 2001 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1479822
11 December 2001 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1077237
12 November 2001 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1487310
10 October 2001 Deadweight Survey · Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1373639
12 September 2001 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1418969
17 August 2001 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420563
29 December 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 808746
19 August 1998 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 797112
6 August 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 804544
10 June 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1130085
4 May 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1427510
17 February 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1364583
16 December 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 781517
18 November 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1378209
3 September 1997 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1390614
1 September 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 75457
23 July 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 779855
14 July 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 4999
2 July 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 42652
2 July 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 777379
25 June 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1113882
10 June 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 124890
5 June 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 155247
2 June 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 42922
27 May 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1406135
12 May 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 104903
29 April 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 181356
19 March 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1099072
21 February 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435879
30 January 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 65781
23 January 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 122132
17 January 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1099352
10 January 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1096642
6 January 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1096713
19 December 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1094107
29 November 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 152014
20 November 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1430314
16 November 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 63821
17 October 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1157270
16 October 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 126989
23 September 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 103675
5 September 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1385813
21 August 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1394606
1 August 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1095467
23 July 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 152600
22 July 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1088331
12 July 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 758522
11 July 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 204150
10 July 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 18061
4 July 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 7828
3 July 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 136363
20 June 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1457368
14 June 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 40410
9 June 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 82305
22 April 1996 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1081190
4 April 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1078981
21 March 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1385663
19 January 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 878254
12 December 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1377566
19 October 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 129604
16 October 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1193215
23 September 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1380304
8 September 1995 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1432950
17 August 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1187016
5 July 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 885942
16 June 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1189029
6 June 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1184153
30 May 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 176367
15 May 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 80123
21 March 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1146803
28 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1168099
22 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 220225
16 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 228983
20 January 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1145396
23 December 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 853934
15 December 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 850041
16 September 1994 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 869873
16 September 1994 Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1363156

Deficiency record · 286

Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 30 May 2014 Resolved
Void aft of engine room had wastage approx 20" from top of bulkheasd x 18" from engine room bulkhead. Wastage was due to water leaking into void above ballast tank due to a poor hatch seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 June 2014
Resolution: A doubler was installed over wasted steel. Doubler accepted as vessel operator states they will scrap the vessel in December 2014. If vessel not scrapped permenant repairs will be required.
Construction/Loadline › Hull › Bottom Plating
Issued 24 July 2012 Resolved
Provide Uwild findings to MSU Paducah unop completion.
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 10 August 2012
Resolution: Received e-mail from Captain with the U-wild results.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 July 2012 Resolved
Paint navigaiton lights screening flat/matte black.
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Fire Fighting › Fire Hydrants › Condition
Issued 24 July 2012 Resolved
Repair/Replace leaking valve for fire station #3.
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 24 July 2012 Resolved
Replace batteries in all battery operated e-lights.
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 24 July 2012 Resolved
Properly repack rox blocks in e-gen room and e-gen CO2 room.
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 24 July 2012 Resolved
Install e-light in the CO2 room to permit local operation of CO2 during emernecy conditions.
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 July 2012 Resolved
label rotating lights in e-gen room to indicate their purpose.
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Communications › Alarms/Indicators › Fire Alarm
Issued 24 July 2012 Resolved
Label CO2 alrm siren in e-gen room.
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 July 2012 Resolved
Replace expired eyewash bottle in e-gen room. Must be the proper sized bottle for mount.
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Documentation › Markings/Placards › Warning Signs
Issued 24 July 2012 Resolved
Replace general alarm sign on second deck by fire station 12.
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 24 July 2012 Resolved
Repair hydrualic leak on stbd side motor for paddle wheel.
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 30 April 2013
Resolution: The seal was replaces to repair leak.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 24 July 2012 Resolved
Repair/Replace jacket water guage for stbd engine for the paddle wheel.
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Electrical › Electrical Distribution System (service) › Switch
Issued 17 July 2012 Resolved
Prove proper operation of e-gen breaker/main generator transfer
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 January 2012 Resolved
Properly label electric panel board in electrical space hold deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 January 2012
Resolution: Panel labeled properly
Stability › Watertight Integrity › General
Issued 13 January 2012 Resolved
Repair jammed door; starboard side Aux Machinery Room to wx deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 29 July 2011 Resolved
KW meter running backwards, trouble shoot and correct. Prove proper operation.
Action required: 705 - Other - as specified
Resolved 14 August 2012
Resolution: Attended vessel to clear discrepancy.
Engineering › Electric Propulsion System › Remote Control Circutry
Issued 27 July 2011 Resolved
Z-drive control system had alarm when operating. Trouble shoot and correct.
Action required: 705 - Other - as specified
Resolved 13 January 2012
Resolution: Tested SAT.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 February 2011 Resolved
Replace light cover stbd side 4th deck stair well.
Action required: 705 - Other - as specified
Resolved 10 June 2011
Resolution: Light cover replaced.
Fire Fighting › Means of Escape › Doorways
Issued 15 February 2011 Resolved
Ensure all fire doors shut properly.
Action required: 705 - Other - as specified
Resolved 10 June 2011
Resolution: All fire doors tested and shut properly.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 February 2011 Resolved
Ensure all e-lights are operational.
Action required: 705 - Other - as specified
Resolved 10 June 2011
Resolution: All E-lights operational.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 February 2011 Resolved
Ensure main roll-up door is incorporated into fire fighting procedures.
Action required: 705 - Other - as specified
Resolved 10 June 2011
Resolution: Main roll-up door incorporated into fire fighting procedures.
Electrical › Electric Generation Source (emergency) › Switch
Issued 15 February 2011 Resolved
Ensure EDG is operational, failed to take the load.
Action required: 705 - Other - as specified
Resolved 15 February 2011
Resolution: Shut down sequence not followed, corrected.
Fire Fighting › Means of Escape › Blocked
Issued 15 February 2011 Resolved
Remove straps from exterior doors on main deck forward and port side.
Action required: 705 - Other - as specified
Resolved 10 June 2011
Resolution: Straps removed.
Construction/Loadline › Structures › Manhole
Issued 15 February 2011 Resolved
Replace missing manhole cover in hold, and bolt in stbd manhole cover.
Action required: 705 - Other - as specified
Resolved 10 June 2011
Resolution: manhole covers replaced and bolted.
Electrical › Lighting (emergency) › Lighting Feeder
Issued 11 August 2008 Resolved
UPS for "E" lighting in soft count room inop. Repair/replace system.
Action required: 705 - Other - as specified
Resolved 1 December 2008
Resolution: Repaired.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 November 2007 Resolved
Check all Emergency light fixtures and renew all extinguished bulbs as required.
Due 20 November 2007
Resolved 20 November 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 November 2007 Resolved
Remove all combustible boxes and items from the 3rd deck aft passenger area and any other passenger accomodation area.
Due 20 November 2007
Resolved 20 November 2007
Construction/Loadline › Structures › Deck Plating
Issued 26 July 2007 Resolved
Provide a gauging report and repair proposal for the 2 inch wasted hole in the main deck on the port side weather deck at the #1 void access hatch.
Condition: Unknown
Due 24 August 2007
Resolved 6 August 2007
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 August 2006 Resolved
PROVIDE ALL DRUG AND ALCOHOL TESTING PROGRAM INFORMATION AS PER THE PROVIDED CHECKLIST.
Due 1 September 2006
Resolved 24 August 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 14 August 2006 Resolved
PRIOR TO GETTING VESSEL UNDERWAY WITH PASSENGERS ONBOARD CONDUCT ALL REQUIRED EMERGENCY DRILLS UNDERWAY TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Action required: 705 - Other - as specified
Resolved 14 August 2006
Lifesaving › Lifebuoys › Serviceable
Issued 22 February 2006 Resolved
Replace three life ring buoys
Due 22 February 2006
Resolved 22 February 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2006 Resolved
Properly dead-end all wires
Due 21 April 2006
Resolved 31 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2006 Resolved
Properly enclose all wire connections
Due 21 April 2006
Resolved 31 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2006 Resolved
Properly support all electrical wires throughout vessel
Due 21 April 2006
Resolved 31 May 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 February 2006 Resolved
Test Bilge alarm in Soft & Hard count rooms.
Due 28 February 2006
Resolved 31 May 2006
Communications › Alarms/Indicators › High Water Alarm
Issued 22 February 2006 Resolved
Replace AFT Lift Station High Level Sensor as noted in third party report
Due 28 February 2006
Resolved 31 May 2006
Engineering › Bilge Water Management System › Piping
Issued 17 November 2005 Resolved
Prove proper operation of installed bilge suction system. A portable pump must remain onboard until deficiency is cleared by CG MI.
Due 18 November 2005
Resolved 21 February 2006
Stability › Watertight Integrity › General
Issued 17 November 2005 Resolved
Install bolts in all deck covers, ensuring water tightness.
Action required: 705 - Other - as specified
Resolved 21 February 2006
Engineering › Diesel Engine (auxiliary) › Block
Issued 17 November 2005 Resolved
Prove proper operation of paddle wheel engine.
Action required: 705 - Other - as specified
Resolved 21 February 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 November 2005 Resolved
Install light bulb cover on HVAC panel.
Action required: 705 - Other - as specified
Resolved 21 February 2006
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 17 November 2005 Resolved
Implement a preventive maintenance program for fire control stations.
Action required: 705 - Other - as specified
Resolved 21 February 2006
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 17 August 2005 Resolved
Properly repair the Emergency generator Main breaker.
Condition: Unknown
Due 22 August 2005
Resolved 14 October 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 August 2005 Resolved
Remove all dead ended wires from the AMR.
Condition: Improper/Lack of Maintenance
Due 19 August 2005
Resolved 14 October 2005
Fire Fighting › Fire Main › Valves
Issued 17 August 2005 Resolved
Properly repair or replace Fire main valve in aft elevator room.
Due 21 August 2005
Resolved 14 October 2005
Construction/Loadline › Structures › Door
Issued 7 March 2005 Resolved
The second access doorway to the Slot Machine Maintenance office is blocked by a workbench and the knob has been removed. Restore proper operation of the door to comply with the requirements of 46 CFR 72.10-5, two means of escape required. This requirement must be completed on or before 07APR05.
Condition: Design Flaw
Due 7 April 2005
Resolved 6 June 2005
Resolution: All items were removed and the door was repaired.
Construction/Loadline › Penetrations › Weld
Issued 11 March 2003 Resolved
Insert through bulkhead 5 not properly installed. Intially cut to allow access for grey water piping installation. Inspected during quarterly exam and found that insert did not cross / tie into vertical framing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2003
Resolved 31 May 2006
Fire Fighting › Fire Pumps › Pressure
Issued 11 March 2003 Resolved
NO. 2 firepump was being removed upon CG Inspectors arrival due to inability to create pressure. Not a severe issue at this time due to vessel being connected to shoreside firefight water. However, it still reamains an CG 835.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 March 2003
Resolved 6 June 2005
Electrical › Electric Generation Source (service)
Issued 16 December 2002 Resolved
Properly terminate unused wires in cables connected batteries to service generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2002
Resolved 9 January 2003
Electrical › Electrical Distribution System (service)
Issued 16 December 2002 Resolved
Label all breakers in electrical panel P407. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2003
Resolved 9 January 2003
Engineering
Issued 16 December 2002 Resolved
Label all valves within the engineering spaces. LEGACY COMPONENT DESC: Various valves
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2003
Resolved 11 March 2003
Resolution: Valves labled in engingeering spaces.
Engineering
Issued 16 December 2002 Resolved
Provide proper guard for paddle wheel hydraulic oil day tank sight glass. LEGACY COMPONENT DESC: Hydraulic Oil Day Tank Sight Glass Guard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 December 2002
Resolved 9 January 2003
Fire Fighting › Fire Main
Issued 16 December 2002 Resolved
Properly paint all piping in engineering spaces to the fire main and automatic sprinkler systems. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 5 March 2003
Resolved 9 January 2003
Fire Fighting › Fire Main
Issued 16 December 2002 Resolved
Label and paint fire main shore tie connections. LEGACY COMPONENT DESC: Shore ties
Action required: 705 - Other - as specified
Due 22 December 2002
Resolved 9 January 2003
Fire Fighting › Ventilation Systems
Issued 16 December 2002 Resolved
Prove proper operation of fire damper reach rods on 2nd deck stern. LEGACY COMPONENT DESC: Fire Damper
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 9 January 2003
Lifesaving › Lifejacket/PFD (General)
Issued 16 December 2002 Resolved
Properly mount stern PFD locker on 3rd deck. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 March 2003
Resolved 11 March 2003
Resolution: lockers properly secured to deck mounting brackets.
Fire Fighting › Structural - A Class Divisions
Issued 16 December 2002 Resolved
Prove proper operation of latch on fire door to offices on the 4th deck. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 9 January 2003
Accommodation/Occupational Safety › Ventilation
Issued 16 December 2002 Resolved
Remove cardboard from duct opening over 1st deck service bar. LEGACY COMPONENT DESC: Duct openings
Action required: 705 - Other - as specified
Due 22 December 2002
Resolved 9 January 2003
Stability › Watertight Integrity
Issued 16 December 2002 Resolved
Properly fasten port and starboard stern void hatches. LEGACY COMPONENT DESC: Hatch covers
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 December 2002
Resolved 9 January 2003
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 September 2002 Resolved
Remove all office furniture and lockers from the fourth deck corridor.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected.
Communications › Alarms/Indicators
Issued 5 September 2002 Resolved
Relocate the General Alarm beacon in Auxiliary space to be visible from all areas. LEGACY COMPONENT DESC: General Alarm
Condition: Placed in Improper Service
Due 5 October 2002
Resolved 9 October 2002
Resolution: Corrected. Delay from CG scheduling, not Harrah''s.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 September 2002 Resolved
Replace missing junction box cover for starboard Z drive.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 5 September 2002 Resolved
Removed dead end wires throughout engineering spaces. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 13 September 2002
Resolution: Corrected
Communications › Visual Communication
Issued 5 September 2002 Resolved
Repair beacon for Sound Powered Phone in main engine room. LEGACY COMPONENT DESC: Signalling Lamp
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Replaced in kind with a new beacon.
Electrical › Electrical Distribution System (emergency) › Junction Box
Issued 5 September 2002 Resolved
Replace packing on junction box for the sprinkler pump motor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Panelboard
Issued 5 September 2002 Resolved
Label breakers on electrical panel 3P231.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 5 September 2002 Resolved
Label electrical panel in the 3rd deck service bar.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 5 September 2002 Resolved
Label breakers in electrical panels in elevator control room. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 9 October 2002
Resolution: Corrected, delay is a result of CG scheduling, not Harrah''s.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 5 September 2002 Resolved
Label breakers in electrical panel #10P203(38).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected.
Fire Fighting › Automatic Sprinkler System › Pump
Issued 5 September 2002 Resolved
Prove proper operation of sprinkler pump in automatic mode.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 September 2002
Resolved 13 September 2002
Resolution: Resolved, initial test proved operation of sprinkler pump in automatic, but revealed that previous flow alarm test was not accurate to prove proper operation. Tested flow alarm on Friday, 13SEP and new process tested flow properly and accurately.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 5 September 2002 Resolved
Ensure elevators go to the main deck, the doors open and they are then disabled in the event of a loss of power.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 September 2002
Resolved 13 September 2002
Resolution: The doors return and open on the first deck. They do not function at all if a pull is activated inside a stair tower. First deck, main floor pull sends elevator to second deck and opens. Cleared, pends further review of system requirements.
Communications › Alarms/Indicators › General Alarm
Issued 5 September 2002 Resolved
Prove proper operation of AEVADS IAW NVIC 8-93.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 September 2002
Resolved 13 September 2002
Resolution: Corrected
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 5 September 2002 Resolved
Install adequate emergency lighting in stairtower, rest rooms and the corridor behind aft main deck bar, to ensure there is enough lighting in the event the emergency generator fails. LEGACY COMPONENT DESC: Open Deck Space
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 9 October 2002
Resolution: Corrected, delay was result of CG scheduling, not Harrah''s.
Electrical › Lighting (emergency)
Issued 5 September 2002 Resolved
Replace burned out light bulb in emergency light on the 3rd deck, port side, stern.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected
Electrical › Lighting (emergency)
Issued 5 September 2002 Resolved
Replace bulb in interior emergency light on the 2nd deck port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected
Electrical › Lighting (emergency)
Issued 5 September 2002 Resolved
Replace bulf in emergency light on the main deck, near the main entrance.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 September 2002 Resolved
Provide covers for 110V outlets in "IT" room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 5 September 2002 Resolved
Provide bracket for portable fire extinguisher #35.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected.
Electrical › Lighting (service) › Switch
Issued 5 September 2002 Resolved
Repair switch box on port side, aft spot light stantion.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 12 September 2002
Resolution: Corrected.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 5 September 2002 Resolved
Provide revised & updated gereral arrangement, structural fire protection, fire control, emergency egress and electrical one line plans approved by the USCG Marine Safety Center, NLT 2/28/2003. LEGACY COMPONENT DESC: General Arrangement Plans
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 31 May 2006
Communications › Alarms/Indicators
Issued 5 September 2002 Resolved
Repair general alarm bells on 2nd deck near high limit slots. LEGACY COMPONENT DESC: General Alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 9 October 2002
Resolution: Corrected, delay was result of CG scheduling, not Harrah''s.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 September 2002 Resolved
Inspect portable fire extinguisher #35.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 4 September 2002
Resolution: Inspected and serviced
Engineering › Non-conventional Propulsion/Steering
Issued 18 June 2002 Resolved
Port Z-drive suddenly failed while being used to wash debris from bow of continously moored casino vessel. LEGACY COMPONENT DESC: Gear Shaft (z-drive)
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2002
Resolved 11 July 2002
Resolution: Unit rebuilt, reinstalled and proper operation demonstrated this date.
Communications › Alarms/Indicators › General Alarm
Issued 18 June 2002 Resolved
Prove proper operation of AEVADS system
Condition: Improper/Lack of Maintenance
Due 18 July 2002
Resolved 8 July 2002
Resolution: Proper operation verified. Activated system with third deck fire alarm pull station and auxilary machinery space smoke detector. Background music automatically cut-off, general alarm and two distinct recorded informational messages piped throughout ship
Unknown
Issued 12 September 2001 Resolved
Submit inventory list of vessel plans with revision numbers and approval status NLT 12OCT01.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Unknown
Issued 12 September 2001 Resolved
Conduct stability tst to be witnessed by the cognizant Officer in Charge, Marine Inspection NLT 12OCT01. Submit results to the USCG Marine Safety Center for approval.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Fire Fighting
Issued 12 September 2001 Resolved
Install inspection ports in ventilation ducts on the 4th deck in the heads adjacent to the automatic fire dampers to the satisfaction of the attendingUSCG Marine Inspector NLT 12OCT01.
Condition: Unknown
Due 12 October 2001
Resolved 5 October 2001
Fire Fighting
Issued 12 September 2001 Resolved
Prove proper operation of manual fire damper for the fan room air intake inthe 1st deck fan room, port side, to the satisfaction of the attending USCGMarine Inspector NLT 12OCT01.
Condition: Unknown
Due 12 October 2001
Resolved 5 October 2001
Fire Fighting
Issued 12 September 2001 Resolved
Reinstall missing fire stops in through deck fittings for cable runs to thesatisfaction of the attending USCG Marine Inspector NLT 12OCT01.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Fire Fighting
Issued 12 September 2001 Resolved
Prove proper operation of the automatic fire damper in the overhead ductingin the starboard side fan room on the 3rd deck NLT 12OCT01 to the satisfacion of the attending USCG Marine Inspector.
Condition: Unknown
Due 12 October 2001
Resolved 5 October 2001
Fire Fighting
Issued 12 September 2001 Resolved
Replace manual reach rod in portside fan room on the 2nd deck to the satisfaction of the attending USCG Marine Inspector. Reach rod is in the deck adjacent to an electrical panel. Complete NLT 12OCT01.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Lifesaving
Issued 12 September 2001 Resolved
Provide rain covers for all exhaust vents for all internal combustion engines to the satisfaction of the attending USCG Marine Inspector NLT 12OCT01.
Condition: Unknown
Due 12 October 2001
Resolved 5 October 2001
Unknown
Issued 12 September 2001 Resolved
Submit revised General Arrangements, structural fire protection, fire control and emergency egress plans to the Marine Safety Center NLT 12OCT01.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Unknown
Issued 12 September 2001 Resolved
Submit revised one line diagram to the USCG Marine Safety Center for approval NLT 12OCT01
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Unknown
Issued 12 September 2001 Resolved
Submit revised fire load calculations to the USCG Marine Safety Center for approval NLT 12OCT01.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Electrical
Issued 12 September 2001 Resolved
Update electric panel directories in 10P203 and P211 panels NLT 12OCT01 to the satisfaction of the attending USCG Marine Inspector.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Lifesaving
Issued 12 September 2001 Resolved
Replace all inoperative bulbs on alarm panels in the Wheel House NLT 12OCT01 to the satisfaction of the attending USCG Marine Inspector
Condition: Unknown
Due 12 October 2001
Resolved 5 October 2001
Engineering
Issued 12 September 2001 Resolved
Maintain M/V Ms T as assist vsl until proper operation of propulsion is proved to the satisfaction of the attending USCG Marine Insepctor and the protective cell required by the USACOR is installed. M/V MS T must be faced up and manned continuously.
Condition: Unknown
Due 31 October 2001
Resolved 5 October 2001
Electrical
Issued 4 May 1998 Resolved
Properly mark all "E" lights and "UPS" lights in office areas of hold deck.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Engineering
Issued 4 May 1998 Resolved
Repair hydrolic oil pump and prove proper operation of paddlewheel/bow thruster pump.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Fire Fighting
Issued 4 May 1998 Resolved
Adjust the fire dampers in the following spaces: Outside air, portside, 3rddeck; Outside air, stbd side aft, 3rd deck; return air, stbd side aft, 2nd deck.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Accommodation/Occupational Safety
Issued 4 May 1998 Resolved
Clean under all air handlers in air handler rooms.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Documentation
Issued 4 May 1998 Resolved
Update Fire and Safety Plan.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Electrical
Issued 4 May 1998 Resolved
Remove or install in box, dead end wires in computer room.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Fire Fighting
Issued 17 February 1998 Resolved
Prove proper operation of tamper switch for sprinkler zone #22.
Condition: Unknown
Due 20 March 1998
Resolved 25 February 1998
Fire Fighting
Issued 18 November 1997 Resolved
ENSURE ALL DOUBLE HUNG DOORS HAVE A MAXIMUM GAP OF 1/8TH INCH.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Lifesaving
Issued 18 November 1997 Resolved
PROVE PROPER OPERATION OF THE GENERAL ALARM IWO BLACK CHERRY SIGN.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Electrical
Issued 18 November 1997 Resolved
PROVE PROPER OPERATION OF "E" LIGHTS IWO 1RST DECK SERVICE BAR
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Construction/Loadline
Issued 18 November 1997 Resolved
ENSURE THE MAIN DECK PENETRATION FROM VOID #5 PORT SIDE MEET THE A-0 SFP REQUIREMENTS.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Electrical
Issued 18 November 1997 Resolved
PROVE PROPER OPERATION OF VOID #5 PORT SIDE OVERHEAD LIGHT FIXTURE.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Electrical
Issued 18 November 1997 Resolved
REMOVE LOOSE WIRING FROM HOT WATER CIRC PUMP JUNCTION BOX IN PUMP ROOM.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Construction/Loadline
Issued 18 November 1997 Resolved
ENSURE ALL DECK PENETRATIONS IN PUMP ROOM OVERHEAD MEET A-0 SFP REQUIREMENTS.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Electrical
Issued 18 November 1997 Resolved
REPAIR OR REPLACE BROKEN SOLENOID COVER ON PORT Z DRIVE STEERING CONTROL LOCATED IN MMR
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Construction/Loadline
Issued 18 November 1997 Resolved
PROVE PROPER OPERATION OF #1 BILGE PUMP. POSSIBLE BREAKER MALFUNCTION.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Navigation
Issued 18 November 1997 Resolved
REPAIR HYDRAULIC OIL LEAK IWO PORT Z DRIVE STEERING CONTROL LOCATED IN MMR.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Fire Fighting
Issued 18 November 1997 Resolved
PROVE PROPER OPERATION OF FSD #4 (LATCH NEEDS ADJUSTMENT).
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Electrical
Issued 18 November 1997 Resolved
PROPERLY SECURE CABLE BRACE ON PORT SIDE OF EMERGENCY DIESEL GENERATOR
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Electrical
Issued 18 November 1997 Resolved
PROPERLY INSTALL WIRING IWO 2ND DECK AFT A/C SPACE OVERHEAD
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Fire Fighting
Issued 18 November 1997 Resolved
PROPERLY ADJUST VALVE STEM NUT ON FIRE STATION #5 ISOLATION VALVE
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Fire Fighting
Issued 18 November 1997 Resolved
ENSURE CABLE WAYS IWO 2ND DECK AC LOCKER AND
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Fire Fighting
Issued 18 November 1997 Resolved
PROVE PROPER OPERATION OF FIRE STATION CUT OUT VALVES IN HOLD OFFICE AREAS,3RD AND 4TH DECKS.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Construction/Loadline
Issued 18 November 1997 Resolved
ENSURE TONNAGE OPENING IWO 2ND DECK ELECTRICAL LOCKER IS PROPERLY BOLTED
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Accommodation/Occupational Safety
Issued 18 November 1997 Resolved
REMOVE ALL TRASH IN VICINITY OF SORTER MACHINES IWO ALL CASHIER CAGES.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Construction/Loadline
Issued 18 November 1997 Resolved
INSTALL GASKETS IN PUMP ROOM GOOSENECK VENTS
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Electrical
Issued 18 November 1997 Resolved
PROVE PROPER OPERATION OF 12VDC "E" LIGHT IWO AMR
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Construction/Loadline
Issued 18 November 1997 Resolved
PROPERLY SECURE HATCHES IWO VOID #3 AND #4. SCREWS MISSING IN BOTH HATCHES
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Accommodation/Occupational Safety
Issued 18 November 1997 Resolved
PROVE PROPER OPERATION OF FORWARD ELEVATOR ALARM.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Electrical
Issued 18 November 1997 Resolved
REPLACE COVER ON E/R PORT SIDE "E" LIGHT
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Electrical
Issued 3 September 1997 Resolved
Prove proper operation of emergency generator.
Condition: Unknown
Due 3 September 1997
Resolved 3 September 1997
Fire Fighting
Issued 3 September 1997 Resolved
Relocate engineroom CO2 siren to forward bulkhead midships. Currently located on after bkhd and partially concealed with overhead insulation.
Condition: Unknown
Due 3 September 1997
Resolved 3 September 1997
Fire Fighting
Issued 3 September 1997 Resolved
Adjust for proper operation, all main entrance doors on 2nd deck.
Condition: Unknown
Due 3 September 1997
Resolved 3 September 1997
Electrical
Issued 3 September 1997 Resolved
prove proper operation of main deck bar (under countertop) lighting.
Condition: Unknown
Due 3 September 1997
Resolved 3 September 1997
Lifesaving
Issued 3 September 1997 Resolved
Replace ring buoys on 3rd deck fwd, 3rd deck aft and 2nd deck aft.
Condition: Unknown
Due 3 September 1997
Resolved 3 September 1997
Electrical
Issued 3 September 1997 Resolved
Prove proper operation of "e" light system throughout the vessel. _x001C_ *Tests on "E" light system could not be completed due to the "e" generator inop.
Condition: Unknown
Due 3 September 1997
Resolved 3 September 1997
Construction/Loadline
Issued 3 September 1997 Resolved
Properly seal gaskets on void #6 hatch port side.
Condition: Unknown
Due 3 September 1997
Resolved 3 September 1997
Electrical
Issued 3 September 1997 Resolved
Replace defective light fixtures in hard count overhead.
Condition: Unknown
Due 3 September 1997
Resolved 3 September 1997
Construction/Loadline
Issued 27 May 1997 Resolved
Repair hydraulic oil leaks IWO wtd #1 cylinder and manual pump.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Install emergency lighting on third deck stbd aft interior.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Fire Fighting
Issued 27 May 1997 Resolved
Repair remote pull for 2nd deck HVAC fire dampers.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Repair exterior Aevaad speakers on forward first, second and third decks.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Engineering
Issued 27 May 1997 Resolved
Prove proper operation of propulsion plant from all modes.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Prove proper operation of #1 SSG.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Clean all battery terminals in MMR and EDG space.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Accommodation/Occupational Safety
Issued 27 May 1997 Resolved
Provide proper egress for third deck stbd aft exit.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Prove proper operation of #1 SSG RPR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Provide proper operation of UPS light in way of 2nd deck rotating sign.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Construction/Loadline
Issued 27 May 1997 Resolved
Upon completion of all vessel alternations contact USCG marine safety office to verify proper installation.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Locate and eliminate electrical grounds in main board.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Repair door on electric panel P415 in 3rd deck HVAC room.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Unknown
Issued 27 May 1997 Resolved
Repair speaker in AMR.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Install junction box covers on conveyor belt motors in hard count.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 21 February 1997 Resolved
MARK 12VDC/UPS "E" LIGHTS IWO 2ND DECK, PORT SIDE, 5TH COLUMN AFT
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Construction/Loadline
Issued 21 February 1997 Resolved
REPAIR HYDRAULIC LEAK ON #1 WTD CYLINDER.
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Accommodation/Occupational Safety
Issued 21 February 1997 Resolved
REPAIR OR REPLACE CEMENT OUTSIDE 3RD DECK STBD SIDE FORWARD DOORS.
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Electrical
Issued 21 February 1997 Resolved
INSTALL UPS/12VDC LIGHTING TO ILLUMINATE THE MAIN BOARD DURING DEAD SHIP (TOTAL LOSS OF POWER) EVOLUTIONS.
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Electrical
Issued 21 February 1997 Resolved
REPAIR 2ND AND 3RD DECK CASHIER CAGE UPS LIGHTING
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Engineering
Issued 21 February 1997 Resolved
REPAIR HYDRAULIC OIL LEAKS ON BOWTHRUSTER AND PADDLEWHEEL HYDRAULIC PUMPS.
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Lifesaving
Issued 21 February 1997 Resolved
PROVIDE ADEQUATE MEANS OF COMMUNICATIONS THROUGHOUT VESSEL.
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Lifesaving
Issued 21 February 1997 Resolved
PROVE PROPER OPERATION OF GENERAL ALARM BELL IWO FIRE STATION #3.
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Accommodation/Occupational Safety
Issued 21 February 1997 Resolved
Ensure all food service areas are thoroughly cleaned
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Engineering
Issued 21 February 1997 Resolved
Install valve handle on #1 s/s air compressor discharge line
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Electrical
Issued 20 November 1996 Resolved
REPLACE PROTECTIVE GLOBE IN BEER COOLER.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Lifesaving
Issued 20 November 1996 Resolved
FIX GENERAL ALARM PORTSIDE FWR 3RD DECK AND PROVE PROPER OPERATION.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Electrical
Issued 20 November 1996 Resolved
REPLACE L/O SENDING UNIT ON PORT SSG INBOARD SIDE.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Electrical
Issued 20 November 1996 Resolved
REPAIR/REPLACE HANDLE ON PANEL P407.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Electrical
Issued 20 November 1996 Resolved
REPAIR/REPLACE ELEVATOR DISCONNECT LATCH HANDLE. (FWR)
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Electrical
Issued 20 November 1996 Resolved
REMOVE 4 SURGE PROTECTORS IN VAULT, OR HARDWIRE AND PERMENANTLY MOUNT.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Electrical
Issued 20 November 1996 Resolved
REMOVE EXTENSION CORD FROM VAULT.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Accommodation/Occupational Safety
Issued 20 November 1996 Resolved
FWR ELEVATOR CONTROL VALVE HAS SEVERAL HYDRAULIC OIL LEAKS, REPAIR AND PROVE PROPER OPERATION.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Accommodation/Occupational Safety
Issued 20 November 1996 Resolved
LABEL VENTS (BOWTHRUSTER) ON MAIN DECK BOW.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Electrical
Issued 20 November 1996 Resolved
REMOVE ALL TEMORARY SURGE PROTECTORS IN BARS, CASHIER CAGES, AND OFFICE SPACES.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Accommodation/Occupational Safety
Issued 20 November 1996 Resolved
CLEAN VENT SCREEN 1ST DECK BEHIND STAGE.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Electrical
Issued 5 September 1996 Resolved
Properly lable sprinkler pump electrical box on aft bulkhead of MMR.
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Fire Fighting
Issued 5 September 1996 Resolved
Prove proper operation of FSD #4 and ensure gap between double doors does not exceed 1/8".
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
Hardwire or remove surge protectors on 1st, 2nd and 3rd deck cashier cage computers (port side).
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Fire Fighting
Issued 5 September 1996 Resolved
Properly mark two (2) manual fire dampers for emergency diesel generator space on 4th deck.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
Properly lable hydrolic water tight breakers on EDG switchboard.
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Unknown
Issued 5 September 1996 Resolved
Repair insulation in MMR above fire sprinkler pump.
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Electrical
Issued 5 September 1996 Resolved
Replace plug on electrical junction box IWO aft B/T hydrolic oil tank in MMR.
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Electrical
Issued 5 September 1996 Resolved
Install panal cover bolts on electrical panals 5P224 and 3P203.
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Lifesaving
Issued 5 September 1996 Resolved
Remove flammable liquids from aft elevator machinery space.
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Fire Fighting
Issued 5 September 1996 Resolved
Ensure gaps between all fire screen doors on 2nd deck leading to gangway donot exceed 1/8".
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
Install globe on light fixture in hard count room.
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Electrical
Issued 5 September 1996 Resolved
Properly lable directory card in 12V DC distribution panal on bridge.
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Electrical
Issued 5 September 1996 Resolved
Properly lable directory card in 24V DC distribution panal on Bridge.
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Electrical
Issued 5 September 1996 Resolved
Properly secure portside overhead wiring in #5 void.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Construction/Loadline
Issued 5 September 1996 Resolved
Ensure proper operation of latches on weatherdeck doors in pilothouse.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Fire Fighting
Issued 5 September 1996 Resolved
Adjust supply fire damper in 3rd deck stbd aft HVAC space and supply fire damper in 3rd deck portside HVAC space.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
Provide directory card for elecrical panal 10P203.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
Properly lable directory in electrical panal 3P231.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Fire Fighting
Issued 5 September 1996 Resolved
Provide UL19 approved hose for fire station #13.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
Properly dead end wires in first deck bar.
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Electrical
Issued 5 September 1996 Resolved
Install globe on light fixture in Z-drive void.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
Properly secure and support all wiring in 1st, 2nd and 3rd deck false ceilings.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
Place Z-drive machinery space lighting on emergency circuit.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Documentation
Issued 5 September 1996 Resolved
Provide MSDS sheets in all spaces containing chemicals & cleaning supplies.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Fire Fighting
Issued 5 September 1996 Resolved
Properly lable remote fire damper pulls to indicate name & location of damper and indicate open & closed positions.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Lifesaving
Issued 5 September 1996 Resolved
Ensure proper operation of general alarms in the following spaces; 2nd deckport HVAC space, 3rd deck stbd aft Hvac space, 2nd deck stbd aft HVAC space.
Condition: Unknown
Due 20 September 1996
Resolved 9 September 1996
Lifesaving
Issued 5 September 1996 Resolved
Ensure Master has access (keys) to all spaces, including office spaces, readily available at all times.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 20 June 1996 Resolved
Install instruction card IWO main deck, aft general alarm station.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Properly label motor controllers IWO beer cooler space compressors
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Install permanent outlets for equipment in surveillance space.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Electrical
Issued 20 June 1996 Resolved
Properly secure wire bundles in wire chases throughout vessel.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Fasten loose wire in 3rd deck ac space stbd aft.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 20 June 1996 Resolved
Repair/Replace handle No 11 fire station.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 20 June 1996 Resolved
Remove all plastic garbage cans from vessel.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Electrical
Issued 20 June 1996 Resolved
Remove or properly install wires at baseboard IWO CB 26.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Lifesaving
Issued 20 June 1996 Resolved
Remove gray metal cabinet 2nd deck aft egress route.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Construction/Loadline
Issued 20 June 1996 Resolved
Repair leaing hydraulic cylinder on #1 WTD
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Electrical
Issued 20 June 1996 Resolved
Replace electrical panel cover 1st deck aft of concession booth.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 20 June 1996 Resolved
Replace fire plan at gangway.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Accommodation/Occupational Safety
Issued 20 June 1996 Resolved
Remove all dunnage, trash and ladder from horse shoe stage.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Provide outlet for refrigerators in deli space.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Properly seal deck wire tubes return deck to A60.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Properly install electrical wiring in elevator equipment room.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 20 June 1996 Resolved
Ensure proper marking of general alarm bells and e-lights throughout the boat.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Lifesaving
Issued 20 June 1996 Resolved
Ensure proper emergency training of non-marine personnel and provide records to mso St. louis.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Fire Fighting
Issued 20 June 1996 Resolved
Adjust FSD 4, 5, 6, 7, 8, and 9 for proper closing.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Lock all electrical panels iwo service bars deck 1, 2 and 3.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Properly install all wiring in surveillance space.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Accommodation/Occupational Safety
Issued 20 June 1996 Resolved
Remove garbage and stores from behind electrical panels in survelliance space.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
repair/replace broken emergency ltg panel handle
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Repair/replace E-light in employee relations space.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Provide socket cover in employee relations space.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Accommodation/Occupational Safety
Issued 20 June 1996 Resolved
Clean all vents IWO A/C spaces throughout the vessel
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Remove/replace plastic wire ties in EDG space overhead.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 20 June 1996 Resolved
Install fire stop IWO cable way, EDG space
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Secure loose wiring bundles in EDG space.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Accommodation/Occupational Safety
Issued 20 June 1996 Resolved
Properly drain dishwasher in 2nd deck service bar.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Electrical
Issued 20 June 1996 Resolved
Repair/replace broken panel door handle on ltg pnl #5EP204
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Install covers on junction boxes in AMR overhead.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Navigation
Issued 21 March 1996 Resolved
REPLACE BULBS FOR UPPER/LOWER NOT UNDER COMMAND LIGHTS AND PROVE PROPER OPERATION.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Electrical
Issued 21 March 1996 Resolved
REPLACE MISSING BULB ON FLOOD/SEARCH LIGHT IWO PORTSIDE AFT PILOTHOUSE DECKAND PROVE PROPER OPERATION.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Navigation
Issued 21 March 1996 Resolved
SHOW PROPER OPERATION OF BOTH PORT AND STBD "Z" DRIVES, RUDDER SYSTEMS.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Fire Fighting
Issued 21 March 1996 Resolved
SHOW PROPER OPERATION OF SPRINKLER PUMP PRIOR TO 1130, 20 MAR 96.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Documentation
Issued 21 March 1996 Resolved
SHOW LOCATION OF F/O VALVE REMOTE FOR EDG SPACE ON FIRE CONTROL PLAN.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Construction/Loadline
Issued 12 December 1995 Resolved
PROVE PROPER OPERATION OF THE #1 BILGE PUMP.
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Fire Fighting
Issued 12 December 1995 Resolved
REPAIR CABLE BRACKET ON SPRINKLER PUMP.
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Navigation
Issued 12 December 1995 Resolved
MAKE AVAILABLE NAVIGATION CHART FOR THE AREA WHERE OPERATIONS ARE PERMITTED
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Fire Fighting
Issued 12 December 1995 Resolved
PROVE PROPER OPERATION OF FSD'S 12/13.
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Lifesaving
Issued 12 December 1995 Resolved
PROPERLY SECURE FOOTLOCKER LOCATED IN THE EDG SPACE.
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Electrical
Issued 12 December 1995 Resolved
REMOVE/SECURE DEAD ENDED WIRING AND PROPERLY COVER CIRCUITS IWO EDG CO2 SPACE.
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Deck/Cargo
Issued 12 December 1995 Resolved
PROVE PROPER OPERATION OF #1 S/S AIR COMPRESSOR.
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Unknown
Issued 12 December 1995 Resolved
PROPERLY COVER ALL CIRCUIT BOARDS AND REPLACE PLYWOOD BULKHEAD W/SUITABLE FIRE RETARDANT MATERIAL
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Fire Fighting
Issued 12 December 1995 Resolved
ADJUST TO FULL CLOSURE AND LATCHING, THE 4 (2 PORT, 2 STBD) A60 FIRE DOORS,IWO MAIN DECK
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Fire Fighting
Issued 12 December 1995 Resolved
REMOVE RETENTION DEVICE IWO FIRE DOOR, PORT SIDE #1 HOLD
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Electrical
Issued 12 December 1995 Resolved
PROVE PROPER OPERATION OF BOTH S/S GENERATOR REVERSE POWER RELAYS.
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Construction/Loadline
Issued 12 December 1995 Resolved
REPAIR #7 VOID HATCH
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Fire Fighting
Issued 12 December 1995 Resolved
REPLACE ALL ALUMINUM FITTINGS WITH BRONZE OR EQUIVALENT IWO ALL AFFECTED FIRE STATIONS AND HOSES.
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Unknown
Issued 12 December 1995 Resolved
PROVE PROPER OPERATION OF PA SYSTEM IWO 3RD DECK AND CORRIDOR ADJACENT TO SECURITY OFFICE.
Condition: Unknown
Due 12 January 1996
Resolved 24 January 1996
Lifesaving
Issued 8 September 1995 Resolved
REPLACE PFD PLACARDS AND PROTECT FROM MOISTURE. PLACARDS IN LOCKERS WERE DETERIORATED DUE TO THE MOISTURE IN THE LOCKER.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Fire Fighting
Issued 8 September 1995 Resolved
#5 FSD WAS DAMAGED DUE TO THE MONEY HANDLING PERSONNEL STRIKING THE DOOR WITH THE MONEY CART. THE HINGES WERE SPRUNG.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Fire Fighting
Issued 8 September 1995 Resolved
CO2 ACTIVATION STATION INSTALLED IN THE E/R ACCESS TRUNK. MUST BE REINSTALLED OUTSIDE THE E/R ACCESS TRUNK AND PROPERLY LABELED/STENCILED.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Fire Fighting
Issued 8 September 1995 Resolved
#10, 12, 13, AND 14 FSD'S WERE OUT OF ADJUSTMENT DUE TO NORMAL WEAR AND TEAR.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Electrical
Issued 8 September 1995 Resolved
FORWARD PASSENGER ELEVATOR ALARM BUTTON INOPERABLE.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Fire Fighting
Issued 8 September 1995 Resolved
SPRINKLER PUMP PIPING (DISCHARGE) WAS NOT BRACKETED/BRACED FOR APPROXIMATELY 20-25 LINEAR FEET RESULTING IN EXCESSIVE VIBRATION.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Accommodation/Occupational Safety
Issued 8 September 1995 Resolved
BOTH SHIPS SERVICE SEWAGE PUMPS HAD ISOLATION MOUNTS INSTALLED TO THE BASE OF THE PUMPS. THE ISOLATION MOUNTS WERE NOT SECURED TO THE DECK ALLOWING FOR THE PIPING TO ABSORB THE VIBRATION.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 8 September 1995 Resolved
CLEAN AND TIGHTEN ALL STARTING BATTERIES CONNECTIONS.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Unknown
Issued 8 September 1995 Resolved
REMOVE HYDRAULIC OIL FROM THE OVERHEAD, BULKHEADS, AND DECK FROM THE BOWTHRUSTER SPACE AND REMOVE OIL FROM THE BOWTHRUSTER WELL.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Engineering
Issued 8 September 1995 Resolved
INSTALL PROPER BRACKETS/CLAMPS TO PREVENT PIPING VIBRATION IN THE HYDRAULICPIPING LEADING TO THE Z DRIVE UNITS.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Engineering
Issued 8 September 1995 Resolved
PROVE PROPER OPERATION OF ALL MDE AND SSG SAFETY DEVICES.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Accommodation/Occupational Safety
Issued 8 September 1995 Resolved
FIRE DOORS NOT PROPERLY NUMBERED.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Engineering
Issued 8 September 1995 Resolved
PROPERLY LABEL ALL VALVES ON THE FUEL OIL MANIFOLD
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Electrical
Issued 8 September 1995 Resolved
REPAIR OR REPLACE ELECTRICAL JUNCTION BOX ON #1 BILGE PUMP.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Accommodation/Occupational Safety
Issued 16 June 1995 Resolved
LABEL SEWAGE FLUSHING LINE VALVE AS OUTLINED ON STATEMENT ON THE VESSEL'S COI.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Accommodation/Occupational Safety
Issued 16 June 1995 Resolved
LABEL ALL HVAC REMOTE SHUTDOWNS ON AFTER WEATHER DECKS.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Fire Fighting
Issued 16 June 1995 Resolved
LABEL CO2 CONTROL STATION FOR EDG AS FOLLOWS: "ENSURE ALL VENTILATION SECURED PRIOR TO OPERATION OF SYSTEM".
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Fire Fighting
Issued 16 June 1995 Resolved
PROVE PROPER OPERATION OF FIRE SCREEN DOORS 4,5, AND 7.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Lifesaving
Issued 6 June 1995 Resolved
PROVIDE APPROVED PRIMARY LIFESAVING DEVICES FOR 220 PERSONS (10% OF PERSONSALLOWED ON BOARD) SERVICED WITHIN THE PAST 12 MONTHS. VESSEL RESTRICTED TO OPERATION WITHIN MOORING CELL UNTIL CORRECTED.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Lifesaving
Issued 15 December 1994 Resolved
REMOVE ALL PLASTIC 5 GAL OIL CANS FROM ENGINE ROOM.
Condition: Unknown
Due 28 December 1994
Resolved 28 December 1994
Fire Fighting
Issued 15 December 1994 Resolved
READJUST TAMPER INDICATORS FOR SPRINKLER SYSTEM HEAD TANK STOP VALVES.
Condition: Unknown
Due 28 December 1994
Resolved 28 December 1994
Electrical
Issued 15 December 1994 Resolved
INSTALL BLANK IN OPENING IN ELECTRICAL PANEL 2EP204.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Fire Fighting
Issued 15 December 1994 Resolved
INSTALL BC-II PORTABLE EXTINGUISHER IN MAIN DECK DELI AND ABC-II EXTINGUISHER IN MAIN DECK GIFT SHOP.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Fire Fighting
Issued 15 December 1994 Resolved
PROVIDE PROOF OF PERIODIC SERVICING OF PORTABLE FIRE EXTINGUISHERS #16, 25,26, AND 27.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Fire Fighting
Issued 15 December 1994 Resolved
REPLACE LEAKING SEAL ENGINE ROOM FIRE PUMP.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Fire Fighting
Issued 15 December 1994 Resolved
REPLACE DEFECTIVE PRESSURE GAUGE AMR FIRE PUMP DISCHARGE LINE.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Documentation
Issued 15 December 1994 Resolved
CONTACT FCC AND OBTAIN FCC STATION LICENSE WITH CORRECT VESSEL OFFICIAL NUMBER (D1026498) LISTED.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Electrical
Issued 15 December 1994 Resolved
INSTALL ELECTRICAL "BLANK" OVER OPENING OF RELOCATED BREAKER ON MAIN SWBD.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Engineering
Issued 15 December 1994 Resolved
ARRANGE FOR QUALITATIVE FAILURE ANALYSIS (QFA) TESTING OF THE INTEGRATED PROPULSION/STEERING SYSTEM.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Lifesaving
Issued 15 December 1994 Resolved
REMOVE HYDROSTATIC RELEASES FROM ALL LIFERAFTS AND ATTACH EACH PAINTER TO THE RESPECTIVE LIFERAFT CRADLE.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Lifesaving
Issued 15 December 1994 Resolved
INSTALL 30X30 FLAME SCREEN IN GOOSENECK VENT AT SEWAGE DISCHARGE MANIFOLD ON MOORING BARGE.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Documentation
Issued 16 September 1994 Resolved
PRIOR TO CARRIAGE OF ANY PASSENGER, WETHER DOCKSIDE OR AWAY FROM SHORESIDE,SHOW PROOF OF VESSEL DOCUMENTATION.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Unknown
Issued 16 September 1994 Resolved
PROVIDE MSO ST LOUIS WITH REQUIRED INFORMATION FOR SPECIFIED EQUIPMENT AND SYSTEMS.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Documentation
Issued 16 September 1994 Resolved
PROVIDE MSO ST LOUIS WITH UPDATED FIRE/SAFETY CONTROL PLAN FOR APPROVAL.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Engineering
Issued 16 September 1994 Resolved
OBTAIN CANVAS FOR COVERS FOR ENGINE ROOM EXHAUST TRUNK AT LOUVER OPENINGS TEXAS DECK.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Documentation
Issued 16 September 1994 Resolved
POST OR MAKE AVAILABLE LISTING OF PERSONNEL IN CHARGE OF FUEL BUNKERING OPS
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995

Casualty record · 2

16 February 2010Routine · role: Involved in a Marine Casualty · 1 dead · activity 3680980
1 October 2014Routine · role: Involved in a Marine Casualty · activity 5006195
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.