MAURY USCG vessel records
← All vessels

MSC NILGUN

Built
1993
Last inspected
9 November 2017
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 November 2017
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9051492
412101
Flag
PANAMA
Maury page id
psix-412101

Documentation record

Tonnage as PSIX records it30971 - Convention (Subpart B), Gross Ton
14641 - Convention (Subpart B), Net Ton
42413 - Dead Weight, Metric Ton
54966 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 12 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

9 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6304482
31 August 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6255952
18 August 2017 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6244464
24 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6219471
28 June 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6189496
26 June 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6187912
26 June 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6188834
7 February 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6083811
4 November 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6031989
16 October 2016 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6023145
13 April 2016 ISPS III Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5853237
12 April 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5852632

Deficiency record · 9

Stability › Watertight Integrity › General
Issued 18 August 2017 Resolved
0930 Where penetrations of watertight bulkheads and internal decks are necessary for access, piping, ventilation, electrical cables, etc., arrangements are to be made to maintain the watertight integrity. PSCO found two extension cords running from a swtchboard in BOSN Store through a watertight door to portable heaters next to the bow thruster unit. 74SOLAS(2004 Cons)II-1/25-9.1
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 18 August 2017
Resolution: Vessel personnel removed two extension cords. All SAT.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 28 June 2017 Resolved
Where remote control of propulsion machinery from the navigation bridge is provided and the machinery spaces are intended to be manned, the speed, direction of thrust and, if applicable, the pitch of the propeller shall be fully controllable from the navigation bridge. Remote control of the propulsion machinery is not functional from the navigation bridge.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 July 2017
Resolved 3 July 2017
Resolution: CLASS ATTENDED THE VESSEL AND CONDUCTED SATISFACTORY REPAIRS. CLASS REPORT RECIEVED.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 16 October 2016 Resolved
74SOLAS (97cons) II-2/47.1 Class 'A' door, to engine room, deadbolt missing, creating an opening in the fire boundary.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2016
Resolution: PSC received satisfactory class report attesting to the proper repairs.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 16 October 2016 Resolved
74SOLAS(04cons) II-1/26.1 Oil steadily leaking from pipe adjacent to local control station; with multiple containers filled with dirty oil.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2016
Resolution: PSC received satisfactory class report attesting to the proper repairs.
Fire Fighting › Fire Main › Condition
Issued 16 October 2016 Resolved
74SOLAS (04 cons) II-1/ 26.1 Piping connected to the main fire pump was found to be excessively corroded and wasted to the point of creating holes on the bottom side of the piping.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 November 2016
Resolution: Received Class Report attesting to proper repairs.
Engineering › Pressure Vessel › Piping
Issued 16 October 2016 Resolved
74SOLAS(04cons) II1/ 26.1 Found leak on cooling line to #3 diesel generator.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 October 2016
Resolution: PSC received satisfactory class report attesting to the proper repairs.
Fire Fighting › Fire Pumps › Pressure
Issued 16 October 2016 Resolved
74SOLAS (14cons) II-2/ 14.2.1.1 Crew took around 90 minutes to operate main fire pump
Action required: 705 - Other - as specified
Resolved 16 October 2016
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 16 October 2016 Resolved
74SOLAS (97cons) II-2/ 11.4.1 Two vents adjacent to the #1 generator were wasted and unable to be closed.
Action required: 705 - Other - as specified
Resolved 16 October 2016
Construction/Loadline › Penetrations › Gasket
Issued 16 October 2016 Resolved
66ICLL I/12.1 Gasket on emergeny escape door from engine room was wasted.
Action required: 705 - Other - as specified
Resolved 16 October 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.