Records from 1996 to 2008. Most recent: inspection, 23 September 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
23 September 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3323328
26 June 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3248473
3 January 2008
MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3124055
5 August 2006
ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2737113
10 January 2006
ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2563918
13 September 2005
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2491980
16 April 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2335220
5 October 2004
Ballast Water Examination · Annual Inspection · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2213676
19 August 2003
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1881205
2 June 2003
Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1807561
1 April 2003
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1761070
29 January 2003
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1736848
12 March 2002
Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1489818
29 January 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 286072
4 January 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 423962
25 August 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 419578
26 November 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 504317
29 August 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 407243
12 May 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 453334
2 December 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 397959
Lifesaving › Lifeboat › Hull
Issued 3 January 2008
Resolved
04Jan2008: Port Lifeboat- pads on davit worn/ indent in aft portion of hull (where contacts with davit); hull worn on forward portion of hull, fiberglass appears partially worn thru (where contacts davit). Classification Society to attest seaworthiness of both lifeboats. SOLAS 74 Amend (1997 Consolidated) III/19
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2008
Resolution: Rec''d Class rpt.
Deck/Cargo › Holds/Tanks
Issued 2 June 2003
Resolved
CARGO HOLD #3 COAMING BRACKETS WASTED WHERE THEY MEET THE DECK, REPAIR AS ORIGNAL. LEGACY COMPONENT DESC: Hatch Cover
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2003
Resolved 19 August 2003
Resolution: Item was replaced
Lifesaving › Lifeboat Equipment
Issued 2 June 2003
Resolved
Replace damaged food rations, 11 port, 8 starboard for a total of 19 rations totaling not less than 10.000 kj each. FAX receipt to attending marine inspector prior to departure Port of Baltimore. LEGACY COMPONENT DESC: Food Ration
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2003
Resolved 6 June 2003
Resolution: Received FAXed invoice from agent for the replacement of 19 food rations.
Lifesaving › Lifeboat
Issued 2 June 2003
Resolved
Vessel has four (4) lifeboats, 2 port & 2 stbd. aft lifeboats are out-of-service on both port & stbd side. Remove out-of-service lifeboats from vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 July 2003
Resolved 19 August 2003
Resolution: Received ABS report dated 14JULY03 by surveyor [name withheld] attesting to lifeboats being secured in place where they can not be used and properly marked "Not to Use".
Pollution Prevention/Response › Prevention Equipment
Issued 29 January 2003
Resolved
Containment inadequate for bunkering stations port and starboard. To be fixed prior to next U.S. port call.
Site: 33 CFR 155.320 LEGACY COMPONENT DESC: Fixed Containment
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 2 April 2003
Resolution: PERMANENT CONTAINMENT ISTALLED AT ALL BUNKERING LOCATIONS.
Lifesaving › Lifeboat Equipment
Issued 12 March 2002
Resolved
STBD LIFEBOAT WILL NOT START. CLASS TO ATTEST TO PROPER OPERATION OF STBD LIFEBOAT PRIOR TO DEPARTURE. 74 SOLAS III 19.2. DUE 12MAR02 LEGACY COMPONENT DESC: Instructions (engine start/operation)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2002
Resolved 15 March 2002
Resolution: STBD LIFEBOAT FOUND SATISFACTORY BY CLASS
Lifesaving › Embarkation Appliances/Stations
Issued 12 March 2002
Resolved
PORT SIDE EMBARKATION LADDER FOR LIFEBOAT WASTED AND TORE AWAY FROM VESSEL. REPLACE EMBARKATION LADDER PORT SIDE. CLASS TO ATTEST TO SERVICABILITY OF STBD EMBARKATION LADDER PRIOR TO DEPARTURE. 74 SOLAS III 16. DUE 12MAR02. LEGACY COMPONENT DESC: Side Ropes
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2002
Resolved 15 March 2002
Resolution: BA02- PORT AND STARBOARD LIFEBOAT EMBARKATION LADDERS RENEWED AS STATED BY CLASS
Fire Fighting › Emergency Fire Pumps
Issued 12 March 2002
Resolved
EMERGENCY FIRE PUMP WULD NOT START. CLASS TO ATTEST TO PROPER OPERATION OF EMERGECY FIRE PUMP PRIOR TO DEPARTURE. 74 SOLAS II 2.4. DUE 12MAR02. LEGACY COMPONENT DESC: Pressure
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2002
Resolved 15 March 2002
Resolution: BA03- EMERGENCY FIREPUMP STARTED AND OPERATED WITH SATISFACTORY PREASURE AS STATED BY CLASS
Pollution Prevention/Response › Prevention Equipment
Issued 12 March 2002
Resolved
MSD TANK, 3 OUTBOARD FRAMERS CRACKED AND LEAKY. MAKE PERMANT REPAIRS. VENT BOX HOLED. MAKE PERMANT REPAIRS TO SATISFACTION OF ATTENDING MARINE INSPECTOR. 33CFR159.57. DUE 12MAR02. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 15 March 2002
Resolution: BA04- CLASS EXAMINED TEMPORARY REPAIRS TO MSD TANK AND FOUND SATISFACTORY. ISSUED RECOMMENDATION FOR PERMANENT REPAIRS PRIOR TO NEXT SPECIAL SURVEY DUE 28FEB03.
Documentation › Certificates/Documents
Issued 12 March 2002
Resolved
CARGO SHIP SAFETY EQUIPMENT CERTIFICATE EXPIRED. CLASS TO CONDUCT ANNUAL SURVEY AND ENDORSE SAFETY CERTIFICATE PRIOR TO DEPARTURE. HAVE CLASS FAX COPY TO USCG. 74 SOLAS I 12. DUE 12MAR02. LEGACY COMPONENT DESC: Cargo Ship Safety Equipment Certificate
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 15 March 2002
Resolution: BA05- CLAS ISSUED CONDITIONAL SLE CERT. PENDING SUPPLY OF 33 SPARE CARTRIDGES FOR DRY CHEMICAL EXTINGUISHERS.
Construction/Loadline › Markings
Issued 12 March 2002
Resolved
LOAD LINES TO BE PAINTED IN CONTRASTING COLOR PRIOR TO DEPARTURE. PORT AND STBD SIDE. ICLL66 I.5. DUE 13MAR02. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2002
Resolved 15 March 2002
Resolution: BA06- LOAD LINE MARKS PAINTED IN CONTRASTING COLORS AS STATED BY CLASS.
Accommodation/Occupational Safety
Issued 25 August 1998
Resolved
Prove the Type II MSD meets Coast Guard certification IAW 33CFR159.12.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Construction/Loadline
Issued 25 August 1998
Resolved
Paint loadline in contrasting colors._x001C_
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Documentation
Issued 25 August 1998
Resolved
Provide documentation from vsl's flag state which indicates acceptance of home flag of current officer's licences IAW STCW I/10.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Navigation
Issued 25 August 1998
Resolved
Repair soft patch on s/w supply line for steering gear IAW ICLL Reg 22._x001C_ to satisfaction of class.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Documentation
Issued 29 August 1997
Resolved
VESSEL'S SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP) DOES NOT INCLUDE A REFERENCE FOR THE UNITED STATES. (MARPOL 73/78 ANNEX 1/26.1)
Condition: Unknown
Due 26 November 1997
Resolved 26 November 1997