Inspection history · 70
17 July 2003
Administrative Inspection
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1848726
11 March 2003
Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1755781
3 September 2002
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1670172
22 October 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 439557
2 October 2001
Examination of Repairs · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1397729
6 April 2001
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 469891
2 January 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 449472
29 August 2000
Examination of Repairs · Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 821924
29 November 1999
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 461430
28 October 1999
Hull Examination · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1399209
3 November 1998
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1404635
29 December 1997
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1118533
13 December 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 501589
13 February 1997
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1105288
2 December 1996
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1433123
4 November 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 518037
8 July 1996
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1087272
8 May 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 481985
26 December 1995
Re-Inspection · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1187469
23 March 1995
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 827711
20 December 1994
COI Inspection · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1465180
21 July 1994
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1179054
6 May 1994
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 860389
19 April 1994
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1167128
18 October 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 498064
9 August 1993
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1157170
17 June 1993
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1133641
30 April 1993
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 837231
9 March 1993
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 525402
8 July 1992
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 946305
19 May 1992
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 950252
10 January 1992
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 507447
26 July 1991
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 537806
19 July 1991
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1306355
10 May 1991
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 900562
10 May 1991
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1306352
13 March 1991
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1236606
25 January 1991
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 458570
8 November 1990
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1231909
4 October 1990
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 506562
17 April 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 436509
12 April 1990
Re-Inspection · Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 909219
10 January 1990
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 907864
5 June 1989
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1352330
24 May 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 449545
23 December 1988
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1346048
1 December 1988
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 894545
16 November 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1204464
15 November 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 476037
28 June 1988
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1339894
12 May 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 477843
9 November 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 526832
2 November 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 490521
5 June 1987
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1335013
25 March 1987
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 470348
11 March 1987
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 516438
26 January 1987
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 476848
5 November 1986
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 509063
15 August 1986
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1308265
3 July 1986
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 998192
29 April 1986
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 452098
2 March 1986
Type not recorded
No type recorded · MSO CINCINNATI · Activity 436869
2 March 1986
Type not recorded
No type recorded · MSO CINCINNATI · Activity 474734
9 October 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 475279
7 August 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 511718
13 June 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291425
8 February 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 445702
25 January 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 454064
8 January 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 480406
27 August 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 440438
Construction/Loadline › Hull
Issued 11 March 2003
Resolved
CROP AND RENEW BOTTOM AND SIDESHELL PLATING WHERE HOLED OR BELOW GAUGING REQUIREMENTS OR REMOVE COI BY 11APR03 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. NO CARGO OPERATIONS. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 April 2003
Resolved 28 January 2004
Resolution: VSL DEACTIVATED.
Deck/Cargo
Issued 30 April 1993
Resolved
PRIOR TO THE TRANSFER OF THE COAL TAR LIGHT OIL PRODUCT, MAKE OPERATIONAL, THE RPM INDICATOR FOR THE CARGO PUMPS' DRIVE UNIT. THIS REQUIREMENT IS TO BE COMPLETED BY NO LATER THAN 31 MAY 1993
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Construction/Loadline
Issued 30 April 1993
Resolved
MAKE REPAIRS IN WAY OF MINOR SHELL FRACTURE THAT IS LOCATED ON THE FORWARD PORT DECK WRAPPER PLATE. REPAIRS ARE TO BE COMPLETED BY NO LATER THAN_x001C_ 31 DECEMBER 1993.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Deck/Cargo
Issued 19 July 1991
Resolved
PRIOR TO USING THE CLOSED GAUGING SYSTEM, MAKE THE SYSTEM AVAILABLE FOR TESTING/INSPECTION IN ACCORDANCE WITH A USCG-MSC APPROVED PLAN.
Condition: Unknown
Due 19 July 1991
Resolved 19 July 1991
Construction/Loadline
Issued 10 May 1991
Resolved
MAKE PERMANENT REPAIRS TO THE PORT STERN TIMBERHEAD IN WAY OF THE 14" BASE FRACTURE.
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Deck/Cargo
Issued 12 April 1990
Resolved
PRIOR TO USE OF THE VAPOR RECOVERY SYSTEM, MAKE THE SYSTEM AVAILABLE FOR TESTING AND INSPECTION IN ACCORDANCE WITH THE USCG - MSC APPROVED PLAN.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Construction/Loadline
Issued 5 June 1989
Resolved
PERMANENTLY REPAIR 4" DECK FRACTURE IN WAY OF AFT STBD TIMBERHEAD AT NEXT GAS FREE AVAILABILITY BUT NOT LATER THAN 31DEC89.
Condition: Unknown
Due 5 June 1989
Resolved 5 June 1989
Construction/Loadline
Issued 16 November 1988
Resolved
MAKE PERMANENT REPAIRS TO THE HOLE IN THE HULL PLATING LOCATED APPROXIMATELY 3" FROM THE BOTTOM IN THE PORT SIDE OF THE BOW VOID. REPAIRS ARE TO BE MADE PRIOR TO LOADING THE NEXT CARGO BUT NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 November 1988
Resolved 16 November 1988
Construction/Loadline
Issued 3 July 1986
Resolved
MAKE PERMANENT REPAIRS TO #1 TRANSVERSE RAISED DECK SUPPORT LAP WELD NOT LATER THAN 31AUG86.
Condition: Unknown
Due 3 July 1986
Resolved 3 July 1986
Accommodation/Occupational Safety
Issued 3 July 1986
Resolved
STRAIGHTEN FWD STBD RAISED DECK LADDER NOT LATER THAN 31AUG86.
Condition: Unknown
Due 3 July 1986
Resolved 3 July 1986
Deck/Cargo
Issued 3 July 1986
Resolved
CONDUCT OR PROVIDE PROOF OF CARGO PIPE HYDROSTATIC TEST NOT LATER THAN 31AUG86.
Condition: Unknown
Due 3 July 1986
Resolved 3 July 1986
Construction/Loadline
Issued 3 July 1986
Resolved
MAKE PERMANENT REPAIRS TO NUMEROUS MOORING FITTING BASE WELD FRACTURES NOT LATER THAN 31AUG86.
Condition: Unknown
Due 3 July 1986
Resolved 3 July 1986
Electrical
Issued 3 July 1986
Resolved
REPLACE STERN ELECTRICAL CAP NOT LATER THAN 31AUG86
Condition: Unknown
Due 3 July 1986
Resolved 3 July 1986
Deck/Cargo
Issued 3 July 1986
Resolved
REPACK STERN CARGO PIPE VALVE STEM REACH ROD NOT LATER THAN 31AUG86.
Condition: Unknown
Due 3 July 1986
Resolved 3 July 1986
Construction/Loadline
Issued 3 July 1986
Resolved
MAKE PERMANENT REPAIRS TO 6" VERTICAL DECK FRACTURE 7' FWD OF # 1 PORT VOID AFT HATCH NOT LATER THAN 31AUG86.
Condition: Unknown
Due 3 July 1986
Resolved 3 July 1986