Records from 1994 to 2011. Most recent: inspection, 2 August 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
2 August 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4102180
11 January 2011
Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3918870
4 October 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 433410
10 June 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 429661
22 July 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 708435
21 July 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 418423
21 January 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 540302
18 July 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 405878
23 June 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 405115
7 May 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 756902
2 May 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 204351
9 April 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 133330
9 January 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 386886
20 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465188
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 2 August 2011
Resolved
Vessel's incinerator has not been operational for over one month, preventing vessel from disposing of sludge/trash.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2011
Resolution: Recieved class report attesting to proper repairs and operation and attended vessel and verified see class report dated 04AUG2011 in documents.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 2 August 2011
Resolved
Vessel is using old oily water separator to store sludge and bilge waste. Vessel has installed unapproved pneumatic pump and piping to discharge oily water and sludge through standard water discharge connection on main deck in 15-20 55 gallon drums via two flexible hoses permanently fixed to standard discharge connection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2011
Resolution: Recieved class report attesting to proper repairs and operation and attended vessel and verified see class report dated 04AUG2011 in documents.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 August 2011
Resolved
Vessel has an excessive amount of oil in bilge under main engines. This poses a fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2011
Resolution: Recieved class report attesting to proper repairs and operation and attended vessel and verified see class report dated 04AUG2011 in documents.
Engineering › Fuel Oil Service System › Flange
Issued 2 August 2011
Resolved
Flanges on fuel oil piping supplying fuel oil to main engine are wrapped in duct tape and strips of nylon.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2011
Resolution: Recieved class report attesting to proper repairs and operation and attended vessel and verified see class report dated 04AUG2011 in documents.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 2 August 2011
Resolved
Flanges on piping for fuel oil purifier are wrapped in duct tape and strips of nylon
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2011
Resolution: Recieved class report attesting to proper repairs and operation and attended vessel and verified see class report dated 04AUG2011 in documents.
Engineering › Diesel Engine (auxiliary) › Silencer (exhaust)
Issued 2 August 2011
Resolved
Both diesel engines for providing compressed air for seismic survey equipment leaking exhaust at all exhaust manifolds.
Action required: 705 - Other - as specified
Due 6 September 2011
Resolved 6 September 2011
Resolution: The diesel engines have been overhauled and tested, no exhaust leaks detected.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 2 August 2011
Resolved
Vessel could not provide copy of Notice of Intent from EPA for Vessel General Permit (VGP).
Action required: 705 - Other - as specified
Resolved 5 August 2011
Resolution: 02AUG11 Vessel master was given instruction on how to file Notice of Intent. 05AUG11 NOI filled out and submitted to EPA.
[name withheld], [name withheld] / [phone withheld] / [email withheld] / MSU Texas City / Texas.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 4 October 1999
Resolved
Provide an additional GMDSS operator prior to departing port.
Condition: Unknown
Due 5 October 1999
Resolved 22 November 2006
Resolution: Verified 3 crew members have GMDSS operator designation.
Electrical › Electric Generation Source (service) › Generator
Issued 4 October 1999
Resolved
Repair the excessive fuel oil leaks from #1 and 2 ship's service generators.
Condition: Unknown
Due 8 October 1999
Resolved 22 November 2006
Resolution: No fuel leaks noted around ship service generators.
Engineering › Fuel Oil Service System › Piping
Issued 4 October 1999
Resolved
Remove the excessive fuel oil from the ship's service generator space bilges.
Condition: Unknown
Due 8 October 1999
Resolved 22 November 2006
Resolution: No excessive fuel oil noted in ship service generator space bilges.
Navigation
Issued 21 July 1998
Resolved
LIGHT LIST AND COAST PILOT NOT CORRECTED AND OUT OF DATE.
Condition: Unknown
Due 22 July 1998
Resolved 22 July 1998
Accommodation/Occupational Safety
Issued 21 July 1998
Resolved
PROVE THAT MARINE SANITATION DEVICE IS COAST GUARD APPROVED. 33 CFR 159
Condition: Unknown
Due 14 June 1999
Resolved 14 June 1999
Navigation
Issued 21 July 1998
Resolved
CONDUCT PRE-ARRIVAL TEST AS PER 33 CFR 164.25
Condition: Unknown
Due 14 June 1999
Resolved 14 June 1999
Lifesaving
Issued 21 July 1998
Resolved
SMOKE SIGNAL LIFEBUOYS HAVE EXPIRED.
Condition: Unknown
Due 24 July 1998
Resolved 24 July 1998
Lifesaving
Issued 21 July 1998
Resolved
EPIRB BATTERY HAS EXPIRED.
Condition: Unknown
Due 24 July 1998
Resolved 24 July 1998
Electrical
Issued 21 July 1998
Resolved
EMERGENCY GENERATOR UNABLE TO START.
Condition: Unknown
Due 24 July 1998
Resolved 24 July 1998
Fire Fighting
Issued 21 July 1998
Resolved
INTERNATIONAL SHORE CONNECTION MISSING GASKET.
Condition: Unknown
Due 24 July 1998
Resolved 24 July 1998
Fire Fighting
Issued 21 July 1998
Resolved
UPDATE FIRE CONTROL PLAN TO SHOW INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 24 July 1998
Resolved 24 July 1998
Accommodation/Occupational Safety
Issued 21 July 1998
Resolved
PROVIDE AND MAINTAIN A PROPER HOSPITAL SPACE. ILO 147
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Documentation
Issued 21 July 1998
Resolved
PROVIDE AND MAINTAIN A PROPER GARBAGE LOG. MARPOL ANNEX V
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Documentation
Issued 21 July 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Construction/Loadline
Issued 23 June 1997
Resolved
LOADLINE NOT PAINTED IN CONTRASTING COLORS WITH HULL.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Navigation
Issued 23 June 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Navigation
Issued 23 June 1997
Resolved
VESSEL DID NOT HAVE CURRENT COPY OF INLAND NAVIGATION RULES ON BOARD.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Fire Fighting
Issued 9 January 1996
Resolved
Vessel's fire nozzle gaskets were wasted._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 January 1996
Resolved 22 January 1996
Navigation
Issued 9 January 1996
Resolved
Vessel failed to have a change over diagram for steering gear.
Condition: Unknown
Due 9 January 1996
Resolved 22 January 1996
Navigation
Issued 9 January 1996
Resolved
Vessel did not have a turning circle diagram._x001C_
Condition: Unknown
Due 10 January 1996
Resolved 22 January 1996