MAURY USCG vessel records
← All vessels

JAMES SURVEYOR

JAMES SURVEYOR is a 1975 towing vessel. The Coast Guard has recorded 2 inspections in 2002, along with 13 deficiencies — 3 with no resolution recorded — and 1 operational control.

Records in 2002. Most recent: inspection, 7 March 2002.

Built
1975
Last inspected
7 March 2002
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

7390961
412942
Flag
UNKNOWN
Maury page id
psix-412942

Inspections, by type

…with no type recorded1
…past their stated due date3
Years with a record 1 calendar year (2002)
The 2 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2356 - Convention (Subpart B), Gross Ton
706 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 2

7 March 2002 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1492143
5 March 2002 Ballast Water Examination · MARPOL Annex V Examination · Administrative Inspection · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1492452

Deficiency record · 13

Navigation › Piloting/Steering
Issued 8 March 2002 Resolved
No corrected charts of appropriate scale LEGACY COMPONENT DESC: Marine Charts
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2002
Resolved 14 March 2002
Navigation › Piloting/Steering
Issued 8 March 2002 Resolved
item missing LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2002
Resolved 14 March 2002
Navigation › Piloting/Steering
Issued 8 March 2002 Resolved
missing Coast Pilot pub LEGACY COMPONENT DESC: US Coast Pilot
Action required: 705 - Other - as specified
Due 8 April 2002
Resolved 14 March 2002
Navigation › Piloting/Steering
Issued 8 March 2002 Resolved
no tide tables or sailing directions onboard LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2002
Navigation › Piloting/Steering
Issued 8 March 2002 Resolved
no nav rules LEGACY COMPONENT DESC: Inland Navigation Rules
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2002
Navigation › Piloting/Steering
Issued 8 March 2002 Resolved
no illumination of magnetic compass LEGACY COMPONENT DESC: Magnetic Compass
Due 6 April 2002
Resolved 14 March 2002
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 8 March 2002 No resolution recorded
missing fact sheet
Due 6 April 2002 — due date passed with no resolution recorded
Personnel › Manning/Qualifications
Issued 8 March 2002 Resolved
No assistant Engineer onbard as required by safe manning document (SOLAS 60, V/13) LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2002
Fire Fighting › Fire Main › Condition
Issued 8 March 2002 No resolution recorded
leak in firemain starboard side aft, by deckhouse (SOLAS 60, II/56)
Due 6 April 2002 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment
Issued 8 March 2002 Resolved
Sewage system open to sea. No treatment or retention (33 CFR 159). Provide temp facilities. LEGACY COMPONENT DESC: Sewage System Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2002
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 8 March 2002 No resolution recorded
No oil transfer procedures
Due 6 April 2002 — due date passed with no resolution recorded
Lifesaving › Launching Appliances
Issued 8 March 2002 Resolved
Lifeboat davit not operational. Prior to depart, vsl must test davit and provide class report. ( LEGACY COMPONENT DESC: Davit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2002
Documentation › Certificates/Documents
Issued 8 March 2002 Resolved
No COFR for vessel. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.