This record may be incomplete: the most recent inspection recorded for this vessel was 36 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
20 - Regulatory (Subpart C or D), Net Ton
20 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-41303
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 6
16 July 1990Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 904765
11 June 1990Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1216737
9 April 1990Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 909210
30 January 1990Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 920419
8 February 1989Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1194389
INSTALL VAPOR-TIGHT FILLING CONNECTION (I.E. FLANGED, APPROVED QUICK DISCONNECT) FOR DECK GAS TANK.
Condition: Unknown
Due 8 May 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 9 April 1990Resolved
INSTALL PRESSURE/VACUUM RELIEF VALVE FOR DECK GAS TANK (2 1/2" PIPE).
Condition: Unknown
Due 8 May 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 9 April 1990Resolved
REPLACE HOSE ON DECK GAS TANK.
Condition: Unknown
Due 8 May 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 9 April 1990Resolved
INSTALL EXPLOSION PROOF WIRING FOR ELECTRIC FUEL PUMP.
Condition: Unknown
Due 8 May 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 30 January 1990Resolved
HYDRO FUEL TRANSFER HOSE TO 225 PSIG. MARK HOSE WITH DATE AND PRESSURE.
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990
Deck/Cargo
Issued 30 January 1990Resolved
INSTALL 30X30 SQ/INCH FLAME SCREEN ON DECK GAS TANK VENT.
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990
Deck/Cargo
Issued 30 January 1990Resolved
INSTALL PRESSURE GAUGE ON DISCHARGE SIDE OF PUMP.
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990