← All vessels
FULL BEAUTY
FULL BEAUTY is a 1994 freight ship. The Coast Guard has recorded 23 inspections since 1995, most recently in July 2012, along with 9 deficiencies and 4 operational controls.
Records from 1995 to 2012. Most recent: inspection, 20 July 2012.
- Built
- 1994
- Last inspected
- 20 July 2012
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9074080 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRVX2
413046
Flag
LIBERIA
—
Maury page id
psix-413046
Inspections, by type
…with no type recorded14
Years with a record
15 calendar years (1995–2012)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it23279 - Convention (Subpart B), Net Ton
79403 - Displacement, Ton
70198 - Dead Weight, Ton
36586 - Convention (Subpart B), Gross Ton
79403 - Displacement, Ton
70198 - Dead Weight, Ton
36586 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
20 July 2012
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4379213
1 November 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3875405
2 March 2009
ISPS I Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3419200
28 February 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3419664
5 August 2008
PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3289464
29 July 2008
ISPS I Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3282312
29 July 2008
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3286018
25 July 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3278666
6 June 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2954278
6 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2955439
4 August 2006
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2735725
22 March 2005
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2317048
16 March 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2312312
15 March 2005
MARPOL Annex V Examination · NPV Safety Exam · ISPS I Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2309110
27 June 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1828195
24 January 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286162
19 February 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 275011
3 March 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426592
17 July 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 418199
3 June 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 404192
5 April 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 388891
5 February 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 375052
3 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 11167
Deficiency record · 9
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 20 July 2012
Resolved
0750-Fire prevention-External hi-press f/o lines shall be protected with jacketed piping system. 3 of M/E's hi-press f/o lines had holes in external jacketing posing a sever fire risk. PSCO questions integrity of all hi-press f/o lines due to their general condition. Provide doc from certificate issuing authority as to the integrity & acceptability of all hi-press lines. SOLAS 74a II-2
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 20 July 2012
Resolved
0750-Fire prevention-The condition of the ship and its equipment shall be maintained to ensure the ship remains fit to proceed to sea. Ship's boiler's f/o pump is leaking oil. C/E stated he has a new pump but needs time to fix it. Provide documentation from certificate issuing authority as to acceptability of leaky condition of boiler's f/o pump. SOLAS 74a I/11
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 July 2012
Resolved
1740-Oil disch mon/control system-Any ship 10,000 GT and above shall be fitted with arrangements to ensure effluent does not exceed 15 ppm. Ship's ORB & OCM do not match. PSC team verified soundings. Provide cert technician's report attesting to proper installation, functionality and recording capabilities of the OCM with concurrence from cert issuing authority. MARPOL I/11, MEPC 107(49)
Engineering › Steering Gear System › Rudder
Issued 20 July 2012
Resolved
0750-Fire prevention-The condition of the ship shall be maintained to ensure it is fit to proceed to sea. PSC team noted numerous leaks from rudder bearing lubricator at the rudder bearing. Provide documentation from certificate issuing authority as to acceptability of leaks. SOLAS 74a I/11
Personnel › Training › Familiarization Training
Issued 20 July 2012
Resolved
PSCO believes there are clear grounds for believing Master/crew are not familiar w/essential shipboard procedures relating to MEPC 107(49). Crew was unaware that OCM recorded data for 18 months and did not know how to recall information from OCM. Provide corrective action plan from company w/concurrence from Administration. MARPOL I/11, MEPC 107(49)
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 1 November 2010
Resolved
1020 Suitable instructions and component spares for testing and maintenance for Fixed Fire Detection and Fire Alarm Systems shall be provided. Vessel was unable to provide proper testing instructions for Fixed Fire Detection and Alarm Systems. SOLAS (97 Cons.) CH II-2 Reg 13.1.12 70(a)
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 November 2010
Resolved
0750 Doors required to be self closing shall not be fitted with hold back hooks. The door heading from the machinery space to the space containing the emergency fire pump is required to be self closing by SOLAS (97 Cons.) CH II-2 Reg 4.3.2.7, and has a permanent hold back fitted on the bulkhead. SOLAS (97 Cons.) CH II-2 Reg 47.2 70(a)
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 1 November 2010
Resolved
1420 Small pools of oil under the main generators and a splattering of oil on some machinery creates a fire hazard and indicates poor general housekeeping in the main engine room. SOLAS (09 Cons.) CH I/11 10(c)
Navigation
Issued 17 July 1998
Resolved
OBTAIN OR UPDATE CURRENT LIGHT LIGHT VOL III.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.