← All vessels
SUN TRADER
SUN TRADER is a 1981 tank ship. The Coast Guard has recorded 11 inspections since 1997, most recently in April 2002, along with 24 deficiencies and 1 operational control.
Records from 1997 to 2002. Most recent: inspection, 11 April 2002.
- Built
- 1981
- Last inspected
- 11 April 2002
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8012097 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9H3151
413062
Flag
MALTA
—
Maury page id
psix-413062
Inspections, by type
…with no type recorded7
Years with a record
4 calendar years (1997–2002)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it819 - Convention (Subpart B), Net Ton
819 - Regulatory (Subpart C or D), Net Ton
3020 - Dead Weight, Metric Ton
4211 - Displacement, Metric Ton
2092 - Convention (Subpart B), Gross Ton
2092 - Regulatory (Subpart C or D), Gross Ton
819 - Regulatory (Subpart C or D), Net Ton
3020 - Dead Weight, Metric Ton
4211 - Displacement, Metric Ton
2092 - Convention (Subpart B), Gross Ton
2092 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
11 April 2002
Deficiency Check · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1603819
9 April 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1602936
9 April 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1603783
28 March 2002
MARPOL Annex I Examination · Certificate of Compliance · Letter of Compliance (Initial/Renewal) · Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1597603
30 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 277276
30 April 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1048925
16 December 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 423550
16 December 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 808247
17 June 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 404731
11 June 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 404446
11 June 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1111022
Deficiency record · 24
Electrical › Electric Generation Source (service)
Issued 28 March 2002
Resolved
RELOCATE POWER TRANSFORMER FROM FRONT OF WASHER MACHINE. LEGACY COMPONENT DESC: Switch
Electrical › Lighting (service)
Issued 28 March 2002
Resolved
MISSING LIGHT FIXTURES COVERS INSIDE SHOWER ROOM OF BERTHING ROOM 210 AND 213, AND WHERE MISSING THROUGHOUT THE SHIP. LEGACY COMPONENT DESC: Lighting Fixture
Pollution Prevention/Response › Prevention Equipment
Issued 28 March 2002
Resolved
REPLACE WOODEN PLUGS WITH MECHANICAL PLUGS TO ALL CONTAINMENT AROUND THE SHIP. LEGACY COMPONENT DESC: Coamings
Lifesaving › Lifeboat
Issued 28 March 2002
Resolved
REPAIR PORT LIFEBOAT ENGINE'S TRANSMISSION, ONLY WORKS AHEAD. LEGACY COMPONENT DESC: Propulsion Transmission
Pollution Prevention/Response › Prevention Equipment
Issued 28 March 2002
Resolved
MISSING PROHIBITED DISCHARGE PLACARD BY THE OILY WATER SEPARATOR.
Documentation › Certificates/Documents
Issued 28 March 2002
Resolved
IOPP HAS TO BE REVIEWED BY CLASS SOCIETY (IOPP FORM B) TO BE IN CONFORMITY WITH CERTIFICATE OF FITNESS FOR THE CARRIAGE OF DANGEROUS CHEMICALS IN BULK AND THE ISM CERTIFICATE. LEGACY COMPONENT DESC: IOPP Certificate
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 March 2002
Resolved
REPAIR OR REPLACE LIFEBOUY LIGHT THAT IS INOPERABLE, LOOCATED ON THE STARDBOARD SIDE FORWARD OF THE LIFEBOAT DAVITT ASSEMBLY.
Deck/Cargo
Issued 30 April 2000
Resolved
vessel not to load cargo tank 5ps until 98% alarm is repaired.
Deck/Cargo
Issued 30 April 2000
Resolved
vessel to ensure all cargo hose assemblies are IAW 33 CFR 154.500.
Documentation
Issued 30 April 2000
Resolved
VESSEL IS ALLOWED TO CARRY ONLY VEG. OILS IN U.S. WATERS UNTIL CLASS SOCIETY PROVIDES A CURRENT UPDATED LIST OF CHEMICALS AND APPROVES P&A MANUAL AND TRANSFER PROCEDURES.
Lifesaving
Issued 30 April 2000
Resolved
PROVIDE EMERGENCY LIGHTERING EQUIPMENT IAW 33 CFR 157.410.
Documentation
Issued 30 April 2000
Resolved
vessel inspected this date for carriage of veg. oils. If vessel wants to carry any other cargo in u.s. waters it must be reinspected by a CG marine inspector.
Deck/Cargo
Issued 30 April 2000
Resolved
vessel is allowed to load only the number of tanks that it has operational portable UTI sensors or a working installed gauging system.
Engineering
Issued 30 April 2000
Resolved
FIX NUMEROUS FUEL LEAKS ON ALL GENERATORS.
Documentation
Issued 30 April 2000
Resolved
PROVIDE GARBAGE MANAGEMENT PLAN.
Documentation
Issued 30 April 2000
Resolved
GARBAGE RECORD BOOK NOT PROPERLY KEPT. RECORD INFORMATION IAW MARPOL 73/78 ANNEX V REG. 9.
Documentation
Issued 30 April 2000
Resolved
OIL RECORD BOOK PART II NOT PROPERLY KEPT. FILL OUT IAW MARPOL 73/78.
Lifesaving
Issued 16 December 1998
Resolved
PRIOR TO DEPARTURE OF THIS U.S. PORT RENEW WATER LIGHTS ON SURVIVAL SUIT.
Lifesaving
Issued 17 June 1997
Resolved
RESPIRATOR CARTRIDGES FOR CHEMICAL SUITS WERE OUT DATED, BUT VESSEL NOT CARRYING HAZMAT THIS VOYAGE. VESSEL MUST HAVE UPDATED CARTRIDGES WHEN CARRYING HAZMAT BEFORE ENTERING NEXT U.S. PORT.
Lifesaving
Issued 17 June 1997
Resolved
CHEMICAL SUITS WERE MISSING THE CHEMICAL GLOVES AND FACE SHIELDS. VESSEL MUST PROVIDE THESE PROTECTIVE ITEMS BEFORE ENTERING NEXT U.S. PORT, WHEN CARRYING HAZMAT.
Lifesaving
Issued 11 June 1997
Resolved
RESPIRATOR CARTRIDGES FOR CHEMICAL SUITS WERE OUT DATED
Fire Fighting
Issued 11 June 1997
Resolved
THE STARTING SYSTEM WIRING WAS IN VERY POOR CONDITION, CREATING A FIRE AND ELECTRICAL SHOCK HAZZARD.
Lifesaving
Issued 11 June 1997
Resolved
CHEMICAL SUITS WERE MISSING THE CHEMICAL GLOVES AND FACSE SHIELDS
Fire Fighting
Issued 11 June 1997
Resolved
EMERGENCY FIRE PUMP LEAKED FUEL OIL EXCESSEIVELY AND SPARKED FROM THE HEAD IN THE AREA OF THE CAM SHAFT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.