MAURY USCG vessel records Sign in
← All vessels

SUN TRADER

SUN TRADER is a 1981 tank ship. The Coast Guard has recorded 11 inspections since 1997, most recently in April 2002, along with 24 deficiencies and 1 operational control.

Records from 1997 to 2002. Most recent: inspection, 11 April 2002.

Built
1981
Last inspected
11 April 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8012097 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9H3151
413062
Flag
MALTA
—
Maury page id
psix-413062

Inspections, by type

…with no type recorded7
Years with a record 4 calendar years (1997–2002)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it819 - Convention (Subpart B), Net Ton
819 - Regulatory (Subpart C or D), Net Ton
3020 - Dead Weight, Metric Ton
4211 - Displacement, Metric Ton
2092 - Convention (Subpart B), Gross Ton
2092 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

11 April 2002 Deficiency Check · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1603819
9 April 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1602936
9 April 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1603783
28 March 2002 MARPOL Annex I Examination · Certificate of Compliance · Letter of Compliance (Initial/Renewal) · Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1597603
30 April 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 277276
30 April 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1048925
16 December 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 423550
16 December 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 808247
17 June 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 404731
11 June 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 404446
11 June 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1111022

Deficiency record · 24

Electrical › Electric Generation Source (service)
Issued 28 March 2002 Resolved
RELOCATE POWER TRANSFORMER FROM FRONT OF WASHER MACHINE. LEGACY COMPONENT DESC: Switch
Condition: Improper Installation
Due 27 April 2002
Resolved 10 April 2002
Resolution: Observed new location of transformer.
Electrical › Lighting (service)
Issued 28 March 2002 Resolved
MISSING LIGHT FIXTURES COVERS INSIDE SHOWER ROOM OF BERTHING ROOM 210 AND 213, AND WHERE MISSING THROUGHOUT THE SHIP. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 27 April 2002
Resolved 10 April 2002
Resolution: Check all shower room of berthing room 210 and 213. All light fixtures are satisfactory.
Pollution Prevention/Response › Prevention Equipment
Issued 28 March 2002 Resolved
REPLACE WOODEN PLUGS WITH MECHANICAL PLUGS TO ALL CONTAINMENT AROUND THE SHIP. LEGACY COMPONENT DESC: Coamings
Condition: Improper Installation
Due 27 April 2002
Resolved 10 April 2002
Resolution: All containment areas around ship have mechanical plugs.
Lifesaving › Lifeboat
Issued 28 March 2002 Resolved
REPAIR PORT LIFEBOAT ENGINE'S TRANSMISSION, ONLY WORKS AHEAD. LEGACY COMPONENT DESC: Propulsion Transmission
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 27 April 2002
Resolved 10 April 2002
Resolution: Port life boat engine works in ahead and astern operation.
Pollution Prevention/Response › Prevention Equipment
Issued 28 March 2002 Resolved
MISSING PROHIBITED DISCHARGE PLACARD BY THE OILY WATER SEPARATOR.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 27 April 2002
Resolved 10 April 2002
Resolution: Observed proper discharge placard by oily water separator.
Documentation › Certificates/Documents
Issued 28 March 2002 Resolved
IOPP HAS TO BE REVIEWED BY CLASS SOCIETY (IOPP FORM B) TO BE IN CONFORMITY WITH CERTIFICATE OF FITNESS FOR THE CARRIAGE OF DANGEROUS CHEMICALS IN BULK AND THE ISM CERTIFICATE. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 15 - Rectify deficiencies by next port
Due 27 April 2002
Resolved 10 April 2002
Resolution: All sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 March 2002 Resolved
REPAIR OR REPLACE LIFEBOUY LIGHT THAT IS INOPERABLE, LOOCATED ON THE STARDBOARD SIDE FORWARD OF THE LIFEBOAT DAVITT ASSEMBLY.
Condition: Improper/Lack of Maintenance
Due 27 April 2002
Resolved 28 March 2002
Resolution: REPLACED BEFORE BOARDINGTEAM LEFT VESSEL.
Deck/Cargo
Issued 30 April 2000 Resolved
vessel not to load cargo tank 5ps until 98% alarm is repaired.
Condition: Unknown
Due 30 April 2000
Resolved 28 March 2002
Resolution: ALARMS TESTED BY INSPECTOR, ALL SAT.
Deck/Cargo
Issued 30 April 2000 Resolved
vessel to ensure all cargo hose assemblies are IAW 33 CFR 154.500.
Condition: Unknown
Due 30 May 2000
Resolved 28 March 2002
Resolution: VISUALLY INSPECTED ALL HOSES USED FOR TRANSFERED, ALL IAW 33CFR154
Documentation
Issued 30 April 2000 Resolved
VESSEL IS ALLOWED TO CARRY ONLY VEG. OILS IN U.S. WATERS UNTIL CLASS SOCIETY PROVIDES A CURRENT UPDATED LIST OF CHEMICALS AND APPROVES P&A MANUAL AND TRANSFER PROCEDURES.
Condition: Unknown
Due 30 April 2000
Resolved 28 March 2002
Resolution: LIST CHECKED BY INSPECTOR.
Lifesaving
Issued 30 April 2000 Resolved
PROVIDE EMERGENCY LIGHTERING EQUIPMENT IAW 33 CFR 157.410.
Condition: Unknown
Due 30 May 2000
Resolved 28 March 2002
Documentation
Issued 30 April 2000 Resolved
vessel inspected this date for carriage of veg. oils. If vessel wants to carry any other cargo in u.s. waters it must be reinspected by a CG marine inspector.
Condition: Unknown
Due 30 April 2000
Resolved 28 March 2002
Resolution: VESSEL CHECKED BY INSPECTOR.
Deck/Cargo
Issued 30 April 2000 Resolved
vessel is allowed to load only the number of tanks that it has operational portable UTI sensors or a working installed gauging system.
Condition: Unknown
Due 30 April 2000
Resolved 28 March 2002
Resolution: SYSTEM TESTED BY INSPECTOR, ALL SAT.
Engineering
Issued 30 April 2000 Resolved
FIX NUMEROUS FUEL LEAKS ON ALL GENERATORS.
Condition: Unknown
Due 30 May 2000
Resolved 28 March 2002
Resolution: INSPECTOR VISUALLY INSPECTED WITH NEGRES.
Documentation
Issued 30 April 2000 Resolved
PROVIDE GARBAGE MANAGEMENT PLAN.
Condition: Unknown
Due 30 May 2000
Resolved 28 March 2002
Resolution: PROVIDED A GARBAGE PLAN.
Documentation
Issued 30 April 2000 Resolved
GARBAGE RECORD BOOK NOT PROPERLY KEPT. RECORD INFORMATION IAW MARPOL 73/78 ANNEX V REG. 9.
Condition: Unknown
Due 30 May 2000
Resolved 28 March 2002
Resolution: RECORD BOOK CHECK BY AGRICULTURE AND INSPECTOR, ALL SAT.
Documentation
Issued 30 April 2000 Resolved
OIL RECORD BOOK PART II NOT PROPERLY KEPT. FILL OUT IAW MARPOL 73/78.
Condition: Unknown
Due 30 May 2000
Resolved 28 March 2002
Resolution: RECORD VERIFIED BY CG INSPECTOR. ALL SAT.
Lifesaving
Issued 16 December 1998 Resolved
PRIOR TO DEPARTURE OF THIS U.S. PORT RENEW WATER LIGHTS ON SURVIVAL SUIT.
Condition: Unknown
Due 28 December 1998
Resolved 28 December 1998
Lifesaving
Issued 17 June 1997 Resolved
RESPIRATOR CARTRIDGES FOR CHEMICAL SUITS WERE OUT DATED, BUT VESSEL NOT CARRYING HAZMAT THIS VOYAGE. VESSEL MUST HAVE UPDATED CARTRIDGES WHEN CARRYING HAZMAT BEFORE ENTERING NEXT U.S. PORT.
Condition: Unknown
Due 30 April 2000
Resolved 30 April 2000
Lifesaving
Issued 17 June 1997 Resolved
CHEMICAL SUITS WERE MISSING THE CHEMICAL GLOVES AND FACE SHIELDS. VESSEL MUST PROVIDE THESE PROTECTIVE ITEMS BEFORE ENTERING NEXT U.S. PORT, WHEN CARRYING HAZMAT.
Condition: Unknown
Due 30 April 2000
Resolved 30 April 2000
Lifesaving
Issued 11 June 1997 Resolved
RESPIRATOR CARTRIDGES FOR CHEMICAL SUITS WERE OUT DATED
Condition: Unknown
Due 17 June 1997
Resolved 17 June 1997
Fire Fighting
Issued 11 June 1997 Resolved
THE STARTING SYSTEM WIRING WAS IN VERY POOR CONDITION, CREATING A FIRE AND ELECTRICAL SHOCK HAZZARD.
Condition: Unknown
Due 17 June 1997
Resolved 17 June 1997
Lifesaving
Issued 11 June 1997 Resolved
CHEMICAL SUITS WERE MISSING THE CHEMICAL GLOVES AND FACSE SHIELDS
Condition: Unknown
Due 17 June 1997
Resolved 17 June 1997
Fire Fighting
Issued 11 June 1997 Resolved
EMERGENCY FIRE PUMP LEAKED FUEL OIL EXCESSEIVELY AND SPARKED FROM THE HEAD IN THE AREA OF THE CAM SHAFT.
Condition: Unknown
Due 17 June 1997
Resolved 17 June 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.