LIL'SALTY

LIL'SALTY is a 1994 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1994, most recently in July 2026, along with 87 deficiencies and 2 casualty investigations between 2011 and 2023.

Records from 1994 to 2026. Most recent: inspection, 9 July 2026.

Built
1994
Last inspected
9 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG4722
413437
Flag
UNITED STATES
367539440
Maury page id
psix-413437

Inspections, by type

…with no type recorded6
Years with a record 31 calendar years (1994–2026)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)28.2 ft × 9.6 ft × 5.0 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOATS INC · CAPE CANAVERAL, FL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST CROIX, VI
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG4722MMSI 367539440 · active · compulsorily equipped · granted 3 May 2022, expires 18 July 2032
WDC5875MMSI 367047770 · expired · voluntarily equipped · granted 7 June 2005, cancelled 8 August 2015
WCP6295MMSI not assigned · expired · voluntarily equipped · granted 12 January 1995, cancelled 19 March 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TARPONSHARK II Freight Barge · MISLE 272880 · 4 November 1999 · activity 134099

Inspection history · 67

9 July 2026 In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8434084
30 March 2026 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8328943
14 October 2025 Examination of Repairs · Internal Structural Exam · Administrative Inspection · Deficiency Check · Hull Examination · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8251357
16 July 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8185801
1 December 2024 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8043170
17 July 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7959893
29 November 2023 Drydock Exam · In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7831176
27 November 2023 Deficiency Check · In-Service Inspection · Administrative Inspection · Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7829706
22 November 2023 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7831636
23 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7701749
26 October 2022 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7584020
16 May 2022 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7445150
29 April 2021 COI Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7184491
14 December 2020 Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7109444
1 June 2020 Annual Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6965108
25 June 2019 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6719997
14 June 2019 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6713971
7 May 2019 Drydock Exam · Internal Structural Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6677765
14 May 2018 Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6692365
25 January 2018 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6343493
9 October 2017 In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6296439
27 June 2017 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6188072
7 June 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6168447
19 April 2017 Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6128909
8 March 2016 COI Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5829285
27 November 2015 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5774532
2 July 2012 Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4364220
24 July 2011 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4105119
25 January 2010 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3669280
16 April 2009 Hull Examination · Examination of Repairs
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3453923
14 October 2008 Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3344176
17 April 2008 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3183808
12 April 2007 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2906752
8 September 2006 Internal Structural Exam · Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2773182
24 April 2006 COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2632103
5 May 2005 Re-Inspection · Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2345165
28 July 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2147813
19 July 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2138499
16 July 2004 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2130861
12 February 2004 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2005522
19 August 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1880986
12 May 2003 Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1793527
27 August 2002 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1667033
24 July 2002 Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1651442
19 June 2002 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1633510
17 June 2002 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1632178
18 April 2002 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1606111
11 February 2002 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1485424
5 June 2001 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1074772
25 April 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 708008
24 April 2001 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1397629
25 July 2000 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 819874
28 June 2000 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1393472
23 December 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 22398
30 November 1999 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1456761
4 November 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 134099
30 April 1999 Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 792001
23 December 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368986
26 October 1998 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1470478
16 January 1998 Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1109484
17 November 1997 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1408000
29 October 1996 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1442476
16 November 1995 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1367560
20 September 1995 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 880002
10 February 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 840558
12 January 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1172366
18 November 1994 Plan Review "T" Boat · Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 866499

Deficiency record · 87

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 March 2026 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. The aft bilge pump was found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2026
Resolution: Vessel operators repaired the wiring for the bilge pump and proved its satisfactory operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 March 2026 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR Subchapter Q. Retroreflective tape on numerous life jackets was found to be deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 31 March 2026
Resolution: Vessel representatives applied new tape to the life jackets.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 30 March 2026 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Two penetrations into the deck were noted in the vicinity of the aft compartment hatch.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 31 March 2026
Resolution: The two deck penetrations have been repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 March 2026 Resolved
The height of top rails must be at least 39.5 inches high. Removable railings on the aft portion of the deck were found to be loose.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 31 March 2026
Resolution: All removable stern railings have been tightened.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2025 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space bilge. The vessel's bilge high level alarm system was found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2025
Resolution: Vessel captain repaired the electrical issue prohibiting the operation of the high level alarm.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2025 Resolved
The minimum number of portable fire extinguishers required on a vessel must not be fewer than the minimum number required by 46 CFR Table 181.500(b). The vessel is required to have a minimum of two portable fire extinguishers on board. At the time of inspection, the vessel only maintained one 40-B:C portable fire extinguisher on board.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2025
Resolution: A second, serviced fire extinguisher was added to the vessel's equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2025 Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. A suitable metal marine type strainer must be fitted in the fuel supply line in the engine compartment. The main diesel engine fuel filter was fitted with a plastic petcock and missing a flame shield.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2025
Resolved 13 August 2025
Resolution: The fuel filter is now fitted with a metal petcock and flame shield.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 July 2025 Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that the pump is permanently mounted. The bilge pump in the forward engine room space was found to be loose and not mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 13 August 2025
Resolution: The bilge pump has been mounted to the hull.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2025 Resolved
Each life jacket must be approved in accordance with 46 CFR Subchapter Q. Retro-reflective tape on four of the adult life jackets was found to be deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 16 July 2025
Resolution: Vessel owner provided picture of new retro-reflective tape applied to the life jackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2025 Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. The forward engine room hatch was not fitted with an attachment device.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 16 July 2025
Resolution: The hatch cover is now fitted with a securing device.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 July 2025 Resolved
A power-driven vessel underway shall exhibit a masthead light forward and a stern light. The masthead and stern navigation lights were found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 16 July 2025
Resolution: The vessel owner provided pictures with the two lights operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2025 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Letters and numbers must be at least 2 inches high. The life jacket stowage location was not marked appropriately.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 18 July 2025
Resolution: Life jacket information is labeled on the entrance to the v-berth.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 July 2025 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. The original Certificate of Documentation could not be produced.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2025
Resolved 20 October 2025
Resolution: The hard copy of the COD is now maintained on board the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 25 July 2024 Resolved
The vessel owner or operator must pay the annual vessel inspection fee each year on or before the vessel's user fee anniversary date. The user fees were found to be past due.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2024
Resolved 1 December 2024
Resolution: The vessel's current and past (balance) user fees have been paid.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 July 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The hydrostatic release unit was found to be expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 30 July 2024
Resolution: A new hydrostatic release unit has been installed and is correctly marked.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2024 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: annual maintenance and recharging of extinguishers. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel management was unable to provide evidence of servicing for the fixed extinguishing system.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 30 July 2024
Resolution: The Fireboy was serviced to ensure compliance.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 July 2024 Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets, with an attached lanyard, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. The fire buckets maintained on board were all in excess of the required size.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 30 July 2024
Resolution: The existing fire buckets were modified to meet the required capacity.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 July 2024 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke distress signals. A hand red flare distress signal may be substituted for a hand orange smoke distress signal. The vessel currently maintains a total of seven hand red flare distress signals on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 25 July 2024
Resolution: Crewmembers provided the required amount of distress signals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 July 2024 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The visual alarm was found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 30 July 2024
Resolution: The visual alarm was operationally tested satisfactorily.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 July 2024 Resolved
A power-driven vessel underway shall exhibit sidelights. The port side running light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 25 July 2024
Resolution: The port side running light was energized and confirmed operable.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 17 July 2024 Resolved
Abandon ship, man overboard, and fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the date of the drill and training and a general description of the drill scenario and training topics. Vessel management could not provide a log or documentation of drills and/or training.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 24 July 2024
Resolution: Operator e-mailed document for recording drills and detailed drills completed on 17JUL2024.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 July 2024 Resolved
Each EPIRB must be tested monthly, which shall be logged or otherwise documented. Vessel management could not provide a log or documentation of these tests.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 24 July 2024
Resolution: Operator e-mailed document for monthly EPIRB testing and showed the test conducted on 17JUL2024.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 July 2024 Resolved
A marine employer shall comply with the requirements of 46 CFR 4.06. The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a Serious Marine Incident. The vessel could not produce alcohol testing devices for all crewmembers serving on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 7 August 2024
Resolution: Vessel owner provided a second alcohol test strip.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 July 2024 Resolved
A vessel must comply with the applicable requirements for any radio installation, including the requirements for a station license and installation certificates to be issued by the FCC in 47 CFR Part 80. Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection in accordance with §80.59 once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. The certificate was found to be expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 30 July 2024
Resolution: The vessel was issued a valid FCC Radiotelephony Certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 July 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 10 August 2024
Resolution: Jake provided proof of new FCC operator permit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 November 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Vessel must prove to Marine Inspector that cause has been repaired and repairs are satisfactory following dinging prop on submerged object.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 November 2023
Resolved 28 November 2023
Resolution: Propeller was swapped and MI conducted satisfactory sea trial. No vibrations were observed. No alarms observed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 October 2022 Resolved
Upon completion of repairs to main engine, an underway sea trial to be conducted to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 October 2022
Resolved 8 November 2022
Resolution: Conducted shake down cruise ALL SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2021 Resolved
ALL VESSELS MUST HAVE NAVIGATION LIGHTS THAT ARE IN COMPLIANCE WITH THE APPLICABLE SECTIONS OF THE INTERNAITONAL AND INLAND NAVIGATION RULES. PORT NAVIGATION LIGHT AND ANCHOR LIGHT WERE INOPERABLE. 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 4 June 2021
Resolution: Rewired the navigation lights.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021 Resolved
EACH SMALL BATTERY INSTALLATION MUST BE PROTECTED FROM FALLING OBJECTS. ONE SMALL BATTERY HAD NO HARD COVERING OVER THE TOP OF IT. 46 CFR 183.540(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 4 June 2021
Resolution: Replaced battery box
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 June 2019 Resolved
T%he vessels steering gear where attached to the frame in the lazarette is loose. Requires attention to ensure it will not break.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 19 July 2019
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2019 Resolved
Life ring is beyond service life. Require replacement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2019
Resolved 25 June 2019
Resolution: New life ring purchased and installed same day.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 25 June 2019 Resolved
Vessel is required to replace the life line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 25 June 2019
Resolution: Replaced same day.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019 Resolved
Several PFDs require replacement as they are beyond service life.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 25 July 2019
Resolution: All PFDs have been purchased and installed as per COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2019 Resolved
Vessel is required to have a working water light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 25 July 2019
Resolution: Vessel purchased new battery.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 June 2019 Resolved
Vessel must undergo an annual inspection within 3 months before or after anniversary date. Vessel annual inspection was due between 08 Dec 2018 to 08 Jun 2019, and was not completed. Vessel must undergo annual inspection prior to carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2019
Resolution: Completed Annual Inspection
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 October 2017 Resolved
Replace 02 unservicable lifejackets. Vessel limited to 11 pax until resolved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2017
Resolved 6 May 2019
Resolution: Resolved
Communications › Radio Communications › EPIRB
Issued 7 June 2017 Resolved
Hydrostatic release had no marking on expiration date.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 June 2017
Resolved 26 June 2017
Resolution: Owner purchased new hydro-static realease and installed ofor EPIRB.
Navigation › Piloting/Steering › Magnetic Compass
Issued 8 March 2016 Resolved
Provide light for magnetic compass.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 15 March 2016
Resolution: Light provided and operational.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 March 2016 Resolved
Provide charts, light list, coast pilot and nav rules.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 15 March 2016
Resolution: All publications provided.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 March 2016 Resolved
Provide clip for 01 child life jacket. Clip broke during inspection.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 15 March 2016
Resolution: New clip provided on life jacket.
Lifesaving › Lifebuoys › Stowage
Issued 8 March 2016 Resolved
Provide 3 to 6 feet of live for lifebuoy.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 15 March 2016
Resolution: Line for lifebuoy added.
Fire Fighting › Fire Bucket › Stenciling
Issued 8 March 2016 Resolved
Provide stenciling and lanyard for fire buckets.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 15 March 2016
Resolution: Stenciling and lanyard provided for fire buckets.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 July 2012 Resolved
Portable and fixed fire fighting bottle servicing is expired. Provide documentation attesting to the proper servicing.
Action required: 705 - Other - as specified
Due 16 July 2012
Resolved 10 July 2012
Resolution: Observed fixed and portable fire extinguishers with servicing label affixed.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 2 July 2012 Resolved
All visual distress signals were expired. Replace prior to passenger operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2012
Resolved 2 July 2012
Resolution: 12 new red hand visual distress signals purchased say day.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 2 July 2012 Resolved
Automatic electric waterlight missing from Buoyant Apparatus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2012
Resolved 31 July 2012
Resolution: Witnessed proper installation and function of automatic electric water light for the Buoyant Apparatus.
Lifesaving › Buoyant Apparatus › Marking
Issued 2 July 2012 Resolved
Buoyant Apparatus missing vessel name and number of persons allowed aboard Bouyant Apparatus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2012
Resolved 10 July 2012
Resolution: Vessel name and number of persons allowed aboard written on Bouyant Apparatus.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 July 2012 Resolved
Retro-reflective tape missing on ring life buoy.
Action required: 705 - Other - as specified
Due 16 July 2012
Resolved 10 July 2012
Resolution: Proper amount of retro-reflective tape placed on both sides of the ring life buoy.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 July 2012 Resolved
Strap clips on 6 lifejackets were broken or otherwise unserviceable. Passenger count reduced to 7 passengers, 2 crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2012
Resolved 10 July 2012
Resolution: Vessel provided same 6 lifejackets with new clips.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 July 2012 Resolved
Safety Radiotelephony Certificate is expired. Provide valid FCC Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 16 July 2012
Resolved 31 July 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 July 2012 Resolved
Vessel has large opening in engine room forward bulkhead. According to MSC approved drawings, the bulkhead should be vapor tight. Provide repair proposal to the attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2012
Resolved 7 August 2012
Resolution: Vessel sealed opening in the upper bulkhead to the space forward to the satisfaction of the RIO St. Croix Supervisor.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 12 April 2007 Resolved
Provide evidence of compliance with 49 CFR 40.25, submission of MIS posting of EAP materials.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 12 April 2007
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 16 July 2004 Resolved
Renew toilet hose clamps
Condition: Improper/Lack of Maintenance
Due 16 July 2004
Resolved 16 July 2004
Lifesaving › Visual Distress Signals (General) › Expired
Issued 16 July 2004 Resolved
Renew distress signals
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 July 2004 Resolved
Renew first aid kit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Discharge Hose/Tube
Issued 16 July 2004 Resolved
Renew cabin portable fire extinguisher nozzle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 July 2004 Resolved
Renew fractured electrical box (2) in steering consoul.
Due 1 August 2004
Resolved 16 July 2004
Engineering › Bilge Water Management System › Hose
Issued 16 July 2004 Resolved
Renew pump hose clamp.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Lifesaving › Lifebuoys › Serviceable
Issued 16 July 2004 Resolved
Renew ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Engineering › Steering Gear System › Bracket/Clamp
Issued 16 July 2004 Resolved
Renew rudder support beam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 16 July 2004 Resolved
Provide FCC Safety Certificate. Vessel is restricted to less than 1000 feet from shore until corrected.
Action required: 705 - Other - as specified
Resolved 16 July 2004
Navigation
Issued 12 May 2003 Resolved
Renew stern light prior to operating at night.
Due 12 June 2003
Resolved 12 May 2003
Navigation
Issued 12 May 2003 Resolved
Make repairs to aft mast head light prior to operating at night.
Due 12 June 2003
Resolved 12 May 2003
Navigation
Issued 12 May 2003 Resolved
Prove proper operation of sound producing devices.
Due 12 June 2003
Resolved 12 May 2003
Lifesaving
Issued 12 May 2003 Resolved
Renew PFD retroreflective tape as needed.
Due 12 June 2003
Resolved 12 May 2003
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 12 May 2003 Resolved
Make repairs to engine tachometer.
Due 12 September 2003
Resolved 12 May 2003
Engineering
Issued 24 July 2002 Resolved
Make repairs to exhaust leak, starboard manifold
Due 24 August 2002
Resolved 24 July 2002
Engineering
Issued 24 July 2002 Resolved
Make repairs to engine room bilge alarms. Until corrected make adequate rounds/examination of engine room.
Due 24 August 2002
Resolved 24 July 2002
Deck/Cargo
Issued 24 July 2002 Resolved
Renew hatch capture devices.
Due 24 August 2002
Resolved 24 July 2002
Lifesaving
Issued 24 July 2002 Resolved
Renew retroreflective tape as needed.
Due 24 August 2002
Resolved 24 July 2002
Engineering
Issued 19 June 2002 Resolved
Make repairs to exhaust tube valve prior to carrying passengers for hire.
Due 19 July 2002
Resolved 19 June 2002
Lifesaving
Issued 24 April 2001 Resolved
RENEW PFD RETROREFLECTIVE TAPE AS NEEDED.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Documentation
Issued 24 April 2001 Resolved
Provide COI
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Navigation
Issued 24 April 2001 Resolved
PROVE OPERATION OF CONTROL REQUIRED BY 46 CFR 184.620.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Construction/Loadline
Issued 24 April 2001 Resolved
RENEW AFT HATCH CAPTURE DEVICE
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Lifesaving
Issued 24 April 2001 Resolved
PROVIDE PFD PLACARD
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Navigation
Issued 24 April 2001 Resolved
RENEW COMPASS LIGHT.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Navigation
Issued 28 June 2000 Resolved
Make repairs to the anchor light._x001C_ Vessel is restricted to daylight operations until corrected.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Navigation
Issued 28 June 2000 Resolved
Makre repairs to the nvaigation side light. Vessel is restricted to daylight operations only until corrected.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Construction/Loadline
Issued 28 June 2000 Resolved
Make repairs to the hatch gasket in the vicinity of the steering station.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Construction/Loadline
Issued 28 June 2000 Resolved
Make repairs to the forward hatch cover.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Engineering
Issued 17 November 1997 Resolved
Mark fuel shut off stations in 1 inch letters indicating the purpose of thevalve and direction of operation in accordance with 46CFR185.608.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Lifesaving
Issued 12 January 1995 Resolved
Renew the retro-reflective tape on all life preservers where deteriorated._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Lifesaving
Issued 12 January 1995 Resolved
Renew/relpace the ten (10) person lifefloat._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Navigation
Issued 18 November 1994 Resolved
PROVIDE CHARTS AND NAUTICAL PUBLICATIONS INCLUDING CHARTS, SAILING DIRECTIONS, COAST PILOT, LIGHT LIST, NOTICE TO MARINERS, TIDE TABLES, AND RULES OF THE ROAD. _x001C_ THE ABOVE DEFICIENCY IS TO BE COMPLETED PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 18 November 1994
Resolved 18 November 1994
Lifesaving
Issued 18 November 1994 Resolved
PROVIDE ALL LIFE SAVING EQUIPMENT INCLUDING A 10 PERSON LIFEFLOAT, LIFE PRESERVERS, RING BUOY, PAINTER LINES, FLOAT FREE LINK, AND WATERLIGHTS. _x001C_ _x001C_ THIS DEFICIENCY IS TO BE COMPLETED PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 18 November 1994
Resolved 18 November 1994
Documentation
Issued 18 November 1994 Resolved
PROVIDE FCC DOCUMENTATION IN WAY OF RADIO STATION LICENSE, RADIO SAFETY CERTIFICATE AND MARINE RADIO OPERATORS LICENSE. PROVIDE A VHF-FM RADIO. _x001C__x001C_ THE ABOVE DEFICIENCY IS TO BE COMPLETED PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 18 November 1994
Resolved 18 November 1994
Documentation
Issued 18 November 1994 Resolved
PROVIDE A MASTERS LICENSES FOR THE VESSEL GT AND AREA OF OPERATION._x001C_ PROVIDE DRUG TESTING DOCUMENTATION DATA. _x001C_ _x001C_ THE ABOVE DEFICIENCY IS TO BE COMPLETED PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 18 November 1994
Resolved 18 November 1994

Casualty record · 2

24 July 2011Routine · role: Involved in a Marine Casualty · activity 4105119
22 November 2023Routine · role: Involved in a Marine Casualty · activity 7831636
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

DIVE EXPERIENCE II (2011–2023). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.