← All vessels
WB 3F
WB 3F is a 1974 tank barge. The Coast Guard has recorded 28 inspections since 1985, most recently in February 2004, along with 36 deficiencies.
Records from 1985 to 2004. Most recent: inspection, 2 February 2004.
- Built
- 1974
- Last inspected
- 2 February 2004
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 36 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
36 - Regulatory (Subpart C or D), Net Ton
36 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 28
2 February 2004
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1999224
18 November 2003
COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1949989
19 October 2001
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1384900
12 September 2001
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1437948
31 August 2000
COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382022
23 August 1999
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1413591
13 November 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 805803
27 August 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1364840
27 August 1997
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 788050
22 October 1996
Re-Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 857023
13 September 1995
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 883121
19 October 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1456206
16 September 1993
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1147982
16 September 1993
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1393986
26 October 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403559
6 January 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1260842
13 November 1991
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 934582
4 October 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 933952
4 October 1991
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1245455
30 October 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1216362
28 September 1990
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 928891
21 November 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 915942
5 October 1989
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1030195
14 December 1988
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1196893
16 October 1987
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1016890
4 December 1986
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1025873
17 November 1986
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1021280
17 October 1985
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 990234
Deficiency record · 36
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 18 November 2003
Resolved
Renew tank vent screen for cargo tank 2P. Screen must be 30 x 30 corrosion-resistant, metallic material. Must be completed before the vessel loads any fuel/cargo. LEGACY COMPONENT DESC: Flame Screens
Fire Fighting
Issued 12 September 2001
Resolved
PROVIDE REQUIRED SERVICING FOR BOTH PORTABLE FIRE EXTINGUISHERS PER 46 CFR 31.10-18
Lifesaving
Issued 31 August 2000
Resolved
Re-paint both sides of warning sign. Re-paint red warning flag.
Deck/Cargo
Issued 31 August 2000
Resolved
Hydrostatically test all fuel hoses to 1.5 times maximum allowable working pressure.
Fire Fighting
Issued 31 August 2000
Resolved
Have forward portable fire extinguisher (B-2) professionally serviced.
Fire Fighting
Issued 31 August 2000
Resolved
Replace mounting bracket for aft portable fire extinguisher.
Electrical
Issued 31 August 2000
Resolved
Replace connection box covers with weather tight covers.
Deck/Cargo
Issued 31 August 2000
Resolved
Replace missing piping diagram for transfer procedures.
Deck/Cargo
Issued 31 August 2000
Resolved
Replace vent screen on stern rake vent.
Deck/Cargo
Issued 27 August 1998
Resolved
Restencil hydrostatic test date on cargo transfer piping and restencil new MAWP (downgraded).
Deck/Cargo
Issued 27 August 1998
Resolved
Replace portside flame screen (30 X 30 mesh, corrosion resist) on port cargo tank vent.
Navigation
Issued 27 August 1998
Resolved
Replace starboard nav. side light element.
Documentation
Issued 22 October 1996
Resolved
REMARK DRAFT MARKS IN CONTRASTING COLOR.
Deck/Cargo
Issued 22 October 1996
Resolved
HYDRO TEST CARGO PIPING.
Deck/Cargo
Issued 22 October 1996
Resolved
HYDRO TEST CARGO HOSE.
Fire Fighting
Issued 22 October 1996
Resolved
HAVE BOTH BII FIRE EXTINGUISHERS SERVICED.
Deck/Cargo
Issued 22 October 1996
Resolved
PROVE PROPER OPERATION OF RED TRANSFER LIGHT.
Deck/Cargo
Issued 22 October 1996
Resolved
REMARK TRANSFER WARNING PLACARD.
Documentation
Issued 22 October 1996
Resolved
REMARK VESSEL'S NAME ON BOW IN CONTRASTING COLOR, AND VESSEL'S NAME AND HAILING PORT ON STERN LOG.
Navigation
Issued 22 October 1996
Resolved
PROVE FIXTURES CURRENTLY INSTALLED FOR PORT/STBD RUNNING LIGHTS MEET INLANDBARGE NAV. RULES.
Deck/Cargo
Issued 13 September 1995
Resolved
INSTALL PERIPHERAL COMBING, AT LEAST 4 INCHES HIGH BUT NOT MORE THAN 8 INCHES HIGH, ENCLOSING THE IMMEDIATE AREA OF THE CARGO HATCHES, LOADING MANIFOLDS, AND TRANSFER CONNECTIONS. DRAIN PORTS SHALL BE PROVIDED AND MECHANICAL MEANS FOR CLOSING EACH DRAIN AND SCUPPER WITHIN THE COMBING.
Deck/Cargo
Issued 13 September 1995
Resolved
CONDUCT HYDROSTATIC TEST OF DISCHARGE PIPING AND HOSE PRIOR TO CARRYING CARGO.
Fire Fighting
Issued 13 September 1995
Resolved
PROVIDE TWO B-II FIRE EXTINGUISHERS PRIOR TO CARRYING CARGO.
Deck/Cargo
Issued 4 October 1991
Resolved
STENCIL CARGO HOSE WITH TYPE OF SERVICE, HYDRO TEST DATE AND MAWP.
Deck/Cargo
Issued 4 October 1991
Resolved
INSTALL CARGO PUMP SHUTOFF SWITCH IN WAY OF CARGO PUMP ENGINE.
Deck/Cargo
Issued 4 October 1991
Resolved
REVISE OIL TRANSFER PROCEDURES TO INDICATE TYPE OF CARGO CARRIED. 33 CFR 155.750 (A)(1).
Deck/Cargo
Issued 4 October 1991
Resolved
PROVIDE FIXED OR PORTABLE RED LIGHT TO BE USED WHEN TRANSFERRING CARGO AT NIGHTS.
Deck/Cargo
Issued 4 October 1991
Resolved
INSTALL A CONTAINMENT COAMING AROUND THE CARGO PUMP AND PUMP ENGINE AT_x001C_ LEAST 4" IN HEIGHT.
Deck/Cargo
Issued 4 October 1991
Resolved
HYDRO CARGO HOSE TO 225 PSIG OR 1 1/2 TIMES MAWP OF THE CARGO SYSTEM,_x001C_ WHICHEVER IS GREATER.
Lifesaving
Issued 4 October 1991
Resolved
STENCIL RING BUOY WITH BARGE NAME.
Deck/Cargo
Issued 4 October 1991
Resolved
INSTALL PRESSURE GAUGE ON DISCHARGE SIDE OF THE CARGO PUMP.
Deck/Cargo
Issued 28 September 1990
Resolved
HYDROSTATICALLY TEST THE CARGO HOSE.
Deck/Cargo
Issued 28 September 1990
Resolved
REPAIR OR REPLACE THE FLAME SCREEN FOR THE STARBOARD TANK OPENING.
Deck/Cargo
Issued 5 October 1989
Resolved
RENEW OR PROVIDE RECORDS OF HYDROSTATIC TESTING FOR CARGO TRANSFER HOSE.
Engineering
Issued 5 October 1989
Resolved
PROVIDE LEAD LINED BATTERY BOX FOR CARGO PUMP STARTING BATTERY.
Deck/Cargo
Issued 14 December 1988
Resolved
HYDROSTATICALLY TEST REEL HOSE AND CARGO PIPING TO 1 1/2 TIMES MAWP IN ACCORDANCE WITH 33 CFR 156.170.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National