← All vessels
CUB
CUB is a 1953 school ship. The Coast Guard has recorded 64 inspections since 1984, most recently in September 2025, along with 57 deficiencies and 2 operational controls.
Records from 1984 to 2025. Most recent: inspection, 24 September 2025.
- Built
- 1953
- Last inspected
- 24 September 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 57 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
WZY7370
41358
Flag
UNITED STATES
—
Maury page id
psix-41358
Inspections, by type
…with no type recorded6
Years with a record
37 calendar years (1984–2025)
The 64 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
97 - Regulatory (Subpart C or D), Gross Ton
0 - Dead Weight, Ton
97 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 64
24 September 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8250663
3 June 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8150513
25 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7939096
26 June 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7721890
10 August 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7501144
17 May 2021
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7196098
29 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7018593
23 July 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6755235
25 July 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6490723
2 August 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6226331
26 May 2016
Administrative Inspection · Drydock Exam · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5886617
12 May 2014
Examination of Repairs · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4858683
13 July 2009
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3533682
29 October 2008
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3353812
4 August 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3285194
29 May 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2939524
25 July 2006
Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2719505
31 May 2006
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2659096
26 August 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2475563
7 June 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2340745
3 December 2004
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2253004
14 June 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2098514
6 June 2003
Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1789562
27 June 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1637584
12 October 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1362488
13 June 2001
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1445823
13 March 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1410503
27 March 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1047704
17 May 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132087
29 April 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1416875
6 October 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 801664
6 April 1998
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1125684
6 March 1998
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1372149
22 April 1997
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1094636
26 March 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1414770
9 September 1996
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806278
9 September 1996
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1404232
11 June 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1400366
22 March 1996
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1371336
14 March 1995
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 865097
11 March 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 854892
25 May 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 830932
22 March 1993
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 837833
30 October 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1242960
28 October 1992
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 180260
18 October 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 962067
13 April 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 952554
18 March 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 959174
4 November 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 937909
4 September 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 940249
12 July 1991
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 936233
16 May 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1221716
13 March 1991
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 918642
21 March 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1240685
6 November 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1036799
5 September 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 898570
27 March 1989
Drydock Extension · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1348974
30 March 1988
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1300332
20 March 1987
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1021562
4 December 1986
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1331135
25 April 1986
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 999639
27 March 1986
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 998315
12 April 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 981266
28 November 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1283810
Deficiency record · 57
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2024
Resolved
If your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, twice every 5 years. No more than 3 years may elapse between any check and its immediate predecessor. UPV pressure relief valve was unable to be tested.
46 CFR 61.10-5(i)(2)
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 26 June 2023
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: (1) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.”. (2) Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. (3) Spaces into which carbon dioxide might migrate—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. DISCHARGE INTO NEARBY SPACE CAN COLLECT HERE. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED VACATE IMMEDIATELY.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. Spaces with CO2 did not have proper markings. Create signs to the satisfaction of the marine inspector. 46 CFR 185.612(g)
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 June 2023
Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate, or equivalent construction. Multiple holes found between the engine room and accommodation space. Repair vapor tight bulkhead to the satisfaction of the marine inspector. 46 CFR 182.35-1
"OLD T"
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 June 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including... Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Hole found between the accommodation space and outside (in the aft life jacket storage). Repair hole to the satisfaction of the marine inspector prior to next credit drydock. 46 CFR 176.802(a)(1)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 August 2022
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having having lounge areas below the main deck. The emergency lighting for forward lounge area was inop and needed to be repaired.
46 CFR 184.30-5(a)(OLD T)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 July 2018
Resolved
Bilge pipe piercing the collision bulkhead must be fitted with a screw down value located on the forward side of the collision bulkhead and operable from the weather deck, or, if it is readily accessible under service conditions, a screw down value without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead. Location of the valve on the bilge suction manifold is too far aft; not a sufficient substitute for a remote operated valve on the weather deck. Install new reach rods to comply with regulation.
Construction/Loadline › Structures › Door
Issued 2 August 2017
Resolved
Repair door between operating station and engine room as to not allow CO2 release into manned space. - 46 CFR 181.20-35 (Old T)
Lifesaving › Lifefloat › Serviceable
Issued 2 August 2017
Resolved
Repair or replace lifefloat (surface wear) IAW manufacturer's instructions & NVIC 2-63. - 46 CFR 185.700
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 August 2017
Resolved
Navigation lights must meet requirements as per Inland Navigation Rules. - 46 CFR 183.420
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 2 August 2017
Resolved
Vessel must provide 02 portable lights at the operating station IAW 46 CFR 183.430.
Engineering › Bilge Water Management System › Piping
Issued 21 October 2016
Resolved
Repair leaking bilge suction pipe in E/R 46CFR182.25
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 October 2016
Resolved
Provide Cover for batteries in E/R 46CFR183.350
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 October 2016
Resolved
Develop plan, then demonstrate ability to recover helpless person from the water IAW 46CFR180.210 at next annual inspection.
Lifesaving › Lifefloat › Paddle
Issued 13 July 2009
Resolved
Life float paddles must be attached to the life float.
Lifesaving › Lifefloat › Markings
Issued 13 July 2009
Resolved
Maximum allowable persons should be marked on the life float in letters at least 2" high.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 July 2009
Resolved
Radar must be operational.
Documentation › Certificates/Documents › FCC SSL
Issued 13 July 2009
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 4 August 2008
Resolved
Renew retroreflective tape material on 10 identified adult type I PFD's
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 August 2008
Resolved
Renew retroreflective material on starboard aft Lifebuoy.
Documentation › Certificates/Documents › FCC SSL
Issued 29 May 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifefloat › Markings
Issued 29 May 2007
Resolved
Write vessel name on lifefloat.
Construction/Loadline › Hull › Bottom Plating
Issued 25 July 2006
Resolved
Repair holes in hull in way of the port side of the rudderpost through hull.
Stability › Watertight Integrity › General
Issued 25 July 2006
Resolved
Repair holes in rudder post housing tube (both sides) in way of the lazarette.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 31 May 2006
Resolved
Install heat shield on Generator exhaust expansion joint.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2006
Resolved
Prove proper operation of ring buoy waterlight and stowage device.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 June 2005
Resolved
Attach waterlight lanyard to ring buoy with a corrosion resistant clip IAW 46 CFR 180.70.
Electrical › Electric Supply System (service) › Cable
Issued 7 June 2005
Resolved
Remove permanently mounted portable battery charger located in engine room.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 June 2005
Resolved
Renew broken circuit breaker switch in distribution panel located outside of the engine room entrance ladder.
Engineering › Pressure Vessel › Relief Valve
Issued 7 June 2005
Resolved
Entered in error.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 3 June 2004
Resolved
Eliminate excessive leakage from shaft log.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 June 2004
Resolved
Renew retro-reflective tape on one ring buoy.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 June 2004
Resolved
Renew retro-reflective tape on 9 adult lifejackets.
Navigation › Collision/Grounding Avoidance
Issued 6 June 2003
Resolved
Repair anchor light per 72 ColRegs. LEGACY COMPONENT DESC: Navigation Lights
Lifesaving › Lifejacket/PFD (General)
Issued 6 June 2003
Resolved
Provide placard for child PFD storage. LEGACY COMPONENT DESC: Placard
Fire Fighting › Fire Pumps
Issued 6 June 2003
Resolved
Repair excessive leak on shaft packing gland for auxillary fire/flushing pump. LEGACY COMPONENT DESC: Gland Sealing
Lifesaving › Lifebuoys
Issued 6 June 2003
Resolved
Provide non-expired battery for lifering water light. LEGACY COMPONENT DESC: Light
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 June 2003
Resolved
Repair aft light shroud for proper arc of visibilty.
Navigation
Issued 29 April 1999
Resolved
PROVE PROPER OPERATION OF PILOT HOUSE ELECTRONIC EQUIPMENT.
Lifesaving
Issued 6 March 1998
Resolved
PROPERLY STENCIL FLARE BOX WITH "DISTRESS SIGNALS".
Electrical
Issued 6 March 1998
Resolved
RETIGHTEN BATTERY CABLE CLAMPS AT ENTRANCE TO AC CABINET AND REMOVE TEMPORARY BATTERY CABLE FROM DC CHARGER TO BATTERY BANK.
Navigation
Issued 6 March 1998
Resolved
PROVE PROPER OPERATION OF DEPTH FINDER.
Lifesaving
Issued 6 March 1998
Resolved
PROVIDE LIFERAFT LAUNCHING INSTRUCTIONS AT LIFERAFT STATION.
Fire Fighting
Issued 22 March 1996
Resolved
Prior to the carriage of passengers, properly service fixed CO2 fire extinguishing system to the satisfaction of the attending CG marine inspector.
Lifesaving
Issued 18 March 1992
Resolved
PROVIDE 6 VALID ORANGE DAYLIGHT DISTRESS SIGNALS. VESSEL MAY NOT GET UNDERWAY UNTIL THIS REQUIREMENT IS ACCOMPLISHED.
Lifesaving
Issued 18 March 1992
Resolved
PROPERLY MARK DECK HATCHES WITH "EMERGENCY EXIT - KEEP CLEAR".
Navigation
Issued 18 March 1992
Resolved
DEMONSTRATE PROPER OPERATION OF RUNNING LIGHTS. UNTIL THIS ITEM IS ACCOMPLISHED, VESSEL WILL NOT OPERATE DURING TIMES OF LIMITED VISIBILTY.
Lifesaving
Issued 13 March 1991
Resolved
LABEL LIFEJACKET STOWAGE.
Accommodation/Occupational Safety
Issued 13 March 1991
Resolved
LABEL ENGINEROOM EMERGENCY EXIT ON MAIN DECK "KEEP CLEAR-EMERGENCY EXIT".
Engineering
Issued 13 March 1991
Resolved
RELABEL EMERGENCY FUEL SHUT OFF.
Fire Fighting
Issued 13 March 1991
Resolved
HYDRO PORTABLE CO2 FIRE EXTINGUISHERS. THIS ITEM TO BE COMPLETED PRIOR TO_x001C_THE CARRIAGE OF PASSENGERS.
Lifesaving
Issued 13 March 1991
Resolved
SHOW PROPER OPERATION OF THE AFT STBD WATER LIGHT FOR LIFEFLOAT.
Engineering
Issued 13 March 1991
Resolved
PLACE PROPER FLAME GUARDS ON RACOR FUEL FILTERS.
Engineering
Issued 13 March 1991
Resolved
INSTALL INSULATION ON MAIN ENGINE EXHAUST PIPES.
Lifesaving
Issued 21 March 1990
Resolved
PROCURE 6 HAND HELD ORANGE SMOKE FLARES.
Lifesaving
Issued 21 March 1990
Resolved
RENEW FORWARD RING LIFEBUOY WHERE GRAB LINES ARE DETERIORATING.
Construction/Loadline
Issued 21 March 1990
Resolved
REPAIR SCUTTLE TO CARGO HOLD WHERE DOGGING MECHANISM IS FRACTURED.
Unknown
Issued 27 March 1986
Resolved
HYDRO OR OPEN FOR INSPECTION AIR RECIEVER(P/V) IN ENGINEROOM.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.