Records from 1985 to 2008. Most recent: inspection, 7 April 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
7 April 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3178986
4 December 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3109435
5 October 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2794191
9 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2563338
25 August 1992
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1248407
26 June 1992
Administrative
Administrative · Commandant (CG-INV-3) · Activity 957956
13 July 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902530
18 May 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1239767
19 May 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346014
20 July 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1033707
20 May 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1044883
5 January 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994054
23 December 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301997
19 November 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332599
23 October 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1325583
23 October 1987
Permit to Proceed
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1326365
20 October 1987
Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1018758
15 October 1987
Administrative
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1018757
27 August 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342428
6 August 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006618
15 May 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336115
6 April 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019073
2 April 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1023333
26 March 1987
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327187
20 March 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018710
10 March 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319018
8 January 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005449
20 November 1986
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327949
2 November 1986
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1017421
19 May 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1296875
8 November 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 992401
17 May 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986412
27 February 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977877
27 February 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 988544
Navigation
Issued 18 May 1990
Resolved
PROVIDE PERMANENT PLANS OF EXISTING NAVIGATION LIGHTS MODIFICATIONS TO USCGMARINE INSPECTION OFFICE NEW YORK, BATTERY PARK BLDG., NEW YORK, NY 10004.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Electrical
Issued 20 May 1988
Resolved
INSTALL GUARDS FOR #1, #2, AND #3 SALT WATER CIRCULATING PUMP AT REEFER SPACE.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Electrical
Issued 20 May 1988
Resolved
REPAIR (2EA) AUTOMATIC DUMP VALVES SOLENOIDS TO THE #2 EVAPORATOR.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Electrical
Issued 20 May 1988
Resolved
INSTALL PROTECTIVE COVER TO ELECTRICAL WIRING TO THE DRAIN BOOSTER PUMP MOTOR.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Documentation
Issued 20 May 1988
Resolved
PROVIDE OIL TRANSFER PROCEDURE OF DIAGRAM AND PERMANENTLY PAST IN DESIG- NATED AREA.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Engineering
Issued 20 May 1988
Resolved
RENEWED 45(EA) SUPERHEATER TUBES ON THE SECOND PASS OF STBD BOILER AND HYDROED TO 925 PSI THE ENTIRE SUPERHEATER TUBES.
Condition: Unknown
Due 20 May 1988
Resolved 20 May 1988
Electrical
Issued 5 January 1988
Resolved
INSTALL LIGHT GUARDS TO ALL LIGHTS WHERE MISSING THROUGHOUT ENGINEERING SPACES.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Accommodation/Occupational Safety
Issued 5 January 1988
Resolved
REPAIR SANITARY PUMP.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Navigation
Issued 5 January 1988
Resolved
REMOVE ALL FIRE HAZARD ITEMS AND CLEAN WATER AND OIL IN AFTER STEERING ROOM.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Accommodation/Occupational Safety
Issued 5 January 1988
Resolved
MAKE PERMANENT REPAIR TO LEAKING CHECK VALVE IN BILGE SUCTION (STEERING GEAR ROOM).
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Accommodation/Occupational Safety
Issued 5 January 1988
Resolved
MAKE PERMANENT REPAIR TO PIPING TO BILGE SUCTION IN STEERING GEAR ROOM.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Electrical
Issued 5 January 1988
Resolved
REPAIR CIRCULATING PUMP #1, #2 AND #3 CONTROLLER AND MOTOR (AT REEFER FLATS).
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Electrical
Issued 5 January 1988
Resolved
REMOVE DEAD END CABLE IN REEFER CONTROLLER.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Deck/Cargo
Issued 5 January 1988
Resolved
PUMP OUT EXCESSIVE OIL IN BILGES.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Engineering
Issued 5 January 1988
Resolved
SIX CRACKS WERE FOUND AROUND THE CRACKED PORT BOILER SIDEWALL HEADER DRAIN PIPE. REPAIRS MADE WITH ACCEPTABLE WELDING PROCEDURE PROVIDED TO NYCMI.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Fire Fighting
Issued 5 January 1988
Resolved
MAKE TEMPORARY REPAIRS TO FIRE MAIN WHERE HOLED ON THE MAIN DECK, STARBOARDSIDE ADJACENT TO THE ENTRANCE TO THE #1 HOLD, AFT OF THE ANCHOR WINCH.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Fire Fighting
Issued 5 January 1988
Resolved
MAKE PERMANENT REPAIR TO THE FIRE MAIN WHERE HOLED ON THE MAIN DECK, STARBOARD SIDE ADJACENT TO THE ENTRANCE TO THE #1 HOLD, AFT OF THE ANCHOR WINCH.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Construction/Loadline
Issued 5 January 1988
Resolved
REALIGN THE HOUSE ACCESS DOOR FROM THE QUARTERDECK ON THE PORT SIDE.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Engineering
Issued 5 January 1988
Resolved
REPAIR AUXILIARY CONDENSATE PUMP #3.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Engineering
Issued 5 January 1988
Resolved
REPAIR COMBUSTION AIR COMPRESSOR.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Engineering
Issued 5 January 1988
Resolved
REPAIR REACH ROD ON BILGE SUCTION OF THE FOLLOWING: SHAFT ALLEY #7 HOLD SUCTION, 6 HOLD P/S, REFRIG. #3 AND 4 HOLD, DIESEL FIRE PUMP ROOM, SUCTION #2 HOLD P/S, SUCTION #3 HOLD STARBOARD, SUCTION #4 HOLD CENTER, # 4 HOLD STARBOARD, AND BILGE SUCTION VALVE CROSSOVER.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Electrical
Issued 5 January 1988
Resolved
PROVIDE COVER FOR STARTING BATTERIES IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Electrical
Issued 5 January 1988
Resolved
STENCIL "E" ON ALL EMERGENCY LIGHTS THROUGHOUT ENGINEERING SPACES.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Fire Fighting
Issued 5 January 1988
Resolved
REPAIR FORWARD AND AFT FIRE PUMP.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Fire Fighting
Issued 5 January 1988
Resolved
PROVIDE HOSES TO THE FOLLOWING STATIONS: #41, #67 AND #60.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Fire Fighting
Issued 5 January 1988
Resolved
PROVIDE MISSING PORTABLE FIRE EXTINGUISHERS TO THE FOLLOWING STATIONS: FE-1-22-1, FE3-129-2 AND FE-2-102-2.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Construction/Loadline
Issued 5 January 1988
Resolved
REPAIR SHAFT ALLEY WTD TO WORK MANUALLY.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Construction/Loadline
Issued 5 January 1988
Resolved
MAKE REPAIR TO DECK IN SHAFT ALLEY TRUNK ONE LEVEL ABOVE SHAFT ALLEY.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Fire Fighting
Issued 23 October 1987
Resolved
RENEW THROUGH HULL SPOOL PIECE FOR THE FORWARD DIESEL FIREPUMP SUCTION LINE.
Condition: Unknown
Due 30 October 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 23 October 1987
Resolved
PROVE OPERATION OF THE FOREPEAK BULKHEAD DRAIN VALVE AND REMOTE REACHROD ASSEMBLY.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
PROVE WATERTIGHT BY HOSE TESTING THE PORT AND STARBOARD MACHINERY SPACE SIDE PORT ACCESS DOORS ALONG WITH THE STARBOARD QUARTER DECK ACCESS SIDE PORT. (DOOR LOCATIONS 2-93-1, 3-132-1, 3-132-2) AS PER 46 CFR 42.15-55.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
MAKE PERMANENT REPAIR TO THE DECK DRAIN LINE WHERE RED HAND PATCHED. DRAINPIPE IS LOCATED IN THE OVERHEAD OF THE PORT EMBARKATION DECK ABOVE FIRE STATION NO. 17 (01-127-2).
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
REPAIR WHERE WASTED THE TWO DECK SUPPORT BEAMS THAT SUPPORT THE 02 DECK, SUBJECT DECK BEAM SUPPORTS ARE LOCATED JUST FORWARD OF THE #9 AND #10 LIFEBOAT DAVITS AT THE 01 DECK BULWARKS.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
REPAIR WHERE WASTED THE BULWARK AND ASSOCIATED BULWARK STAYS ON THE PORT AND STARBOARD SIDE OF THE 01 DECK FROM THE AREA OF THE GANGWAY WINCHES TO THE #9 AND #10 LIFEBOAT DAVIT CONTROLLERS.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Electrical
Issued 23 October 1987
Resolved
RENEW OR PROVIDE PERMANENT REPAIR TO THE #9 LIFEBOAT STATION EMERGENCY SWITCH ENCLOSURE BOX.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Electrical
Issued 23 October 1987
Resolved
REFIT WHERE MISSING THE ELECTRICAL WIRE CABLE RUN RETAINING CLIPS FOR THE #9 LIFEBOAT STATION MOREK BACK SYSTEM.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
MAKE PERMANENT REPAIRS TO THE DECK DRAIN LINE WHERE HOLED AND PATCHED OVER IN TWO AREAS. THE DRAIN LINE LEADS FROM ABOVE THE [name withheld] TO THE EMBARKATION DECK IN THE AREA OF THE #3 LIFEBOAT STATION.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Engineering
Issued 23 October 1987
Resolved
MAKE PERMANENT REPAIRS OR RENEW THE FUEL OIL TANK VENT RISER LOCATED ON THE MAIN CARGO DECK OUTBOARD OF THE #6 HATCH ON THE STARBOARD SIDE.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
REPAIR WHERE HOLED THE #9 LIFEBOAT DAVIT ASSEMBLY FORWARD AND AFT INBOARD DAVIT SUPPORT BEAMS.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Deck/Cargo
Issued 23 October 1987
Resolved
RENEW WHERE WASTED THE VENTILATION INTAKE ENCLOSURE HOOD LOCATED ON THE STARBOARD SIDE OF THE #6 WINCH CONTROL OPERATING STATION OUTBOARD OF THE MAST.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Deck/Cargo
Issued 23 October 1987
Resolved
REPAIR WHERE WASTED THE VENTILATION DUCT WORK (WASTED AT DECK CONNECTION) LOCATED ON THE PORT SIDE OF THE #6 WINCH CONTROL OPERATING STAND. ALSO RENEW THE COVER AND SCREENING FOR THIS VENT DUCT.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Electrical
Issued 23 October 1987
Resolved
REFIT THE ELECTRIC WIRE CABLE GUARD THAT PASSES FROM THE AFT 01 DECK TO THEMAST AT THE NO. 6 WINCH CONTROL STAND.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Accommodation/Occupational Safety
Issued 23 October 1987
Resolved
REBUILD WHERE WASTED THE MAIN CARGO DECK LADDER STRINGERS ON THE FORWARD AND AFTER DECKS.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
REBUILD WHERE WASTED THE BULWARK STAYS ON THE 02 DECK FORWARD OF THE NO. 1 & NO. 2 LIFEBOAT STATIONS. SUBJECT DECK WRAPS AROUND THE SUPERSTRUCTURE. THE TRIPPING PLATES ARE TO BE REMOVED FROM BETWEEN THE BULWARK STAYS FOR FURTHER INSPECTION.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
PRIOR TO THE REINSTALLATION OF VENTILATION EQUIPMENT, ON GOING DECKING REPAIRS ARE TO BE EXAMINED BY A COAST GUARD MARINE INSPECTOR. THE SUBJECT VENTILATION SPACE IS LOCATED INBOARD OF THE #4 LIFEBOAT DAVIT ASSEMBLY ON THE 02 LEVEL.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Fire Fighting
Issued 23 October 1987
Resolved
RENEW THE FIREHOSE SUPPORT BRACING. REFIT A HOSE RETAINING BAR TO THE FIRESTATION LOCATED ON THE 02 LEVEL INBOARD OF THE #6 LIFEBOAT DAVIT, AND PROPERLY MARK THE FIRESTATION.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
HAVE RECONDITIONED AT A COAST GUARD APPROVED REPAIR FACILITY THE NUMBER SIX LIFEBOAT.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
RENEW THE HANDWHEEL FOR THE #10 LIFEBOAT DAVIT WINCH ASSEMBLY.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
HAVE RECONDITIONED AT A COAST GUARD APPROVED REPAIR FACILITY THE NUMBER 5 LIFEBOAT.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
REPAIR WHERE WASTED THE BULWARK STRUCTURE AND ASSOCIATED BULWARK STAYS ON THE 03 DECK.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
REMOVE FROM SERVICE AND HAVE REPAIRS EFFECTED TO THE NO. 8 LIFEBOAT WHERE THE GRABRAILS HAVE PULLED AWAY FROM THE BOATS SHELL PLATING. THIS IS TO BEACCOMPLISHED BY A COAST GUARD CERTIFIED REPAIR FACILITY.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Electrical
Issued 23 October 1987
Resolved
RELAMP THE #1, #2, #6 AND #7 LOWER HOLDS. GUARDS AND GLOBE COVERS ARE TO BE PROVIDED AT ALL LIGHTING FIXTURES.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Electrical
Issued 23 October 1987
Resolved
PROVIDE COVERS FOR THE LIGHTING FIXTURES IN WAY OF THE INTERIOR HATCH COAMING ON THE 2ND DECK IN HOLDS NO. 2, 6 AND 7.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
PROVIDE LAUNCHING INSTRUCTIONS ON THE LIFERAFT CONTAINERS AS REQUIRED BY 46 CFR 160.051-8(B).
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
RENEW THE DECK DRAIN LINES WHERE WASTED AT THE DECK PENETRATIONS IN THE AREAS ABOVE THE STOWAGE LOCKERS LOCATED FORWARD OF THE #9 AND #10 LIFEBOAT DAVITS (SEE REQUIREMENT D4).
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
HAVE REPAIRS EFFECTED BY A COAST GUARD APPROVED REPAIR FACILITY OF THE #3 LIFEBOAT WHERE THE HULL JOINTS IN WAY OF BOW & STERN HAVE BEGUN TO SEPARATE.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
REMOVE FROM SERVICE AND HAVE REPAIRS EFFECTED TO THE NUMBER 9 LIFEBOAT WHERE THE SIDESHELL PLATING HAS HOLED AND DETERIORATED IN WAY OF THE MANUFACTURERS NAME PLATE AND ALONG THE CAP RAIL RIVETTED JOINT. THIS REPAIR IS TO BE ACCOMPLISHED BY AN APPROVED COAST GUARD REPAIR FACILITY.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
MAKE REPAIRS TO THE #7 LIFEBOAT WHERE THE LOWER GRABRAILS ARE PULLING AWAY FROM THE HULL PLATING.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
MAKE REPAIRS TO THE #10 LIFEBOAT WHERE THE GRABRAILS ARE PULLING AWAY FROM THE HULL PLATING.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
REMOVE THE WASTED STORES DAVIT SUPPORT MEMBER THAT IS MOUNTED AFT OF THE FORWARD BOSUN STORES/FOREPEAK ACCESS HATCH COAMING.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
PROVIDE EMBARKATION FLOOD LIGHTS FOR THE THREE LIFERAFT LAUNCHING STATIONS USING THE EMERGENCY LIGHTING SYSTEMS. (46 CFR 112.43-11)
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
RENEW THE #1 LIFERAFTS CONTAINER PLUG FOR THE SEAPAINTER.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
PROPERLY DISPLAY THE PORT/STARBOARD FREEBOARD DECK MARKS.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Fire Fighting
Issued 23 October 1987
Resolved
REPAIR WHERE HOLED THE FIREMAIN PIPING AT FIRE STATION 34.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Accommodation/Occupational Safety
Issued 23 October 1987
Resolved
REPAIR THE DAVIT SUPPORT ASSEMBLY WHERE PULLING AWAY FROM THE 02 DECK COAMING. DAVIT IS FOR THE PORT ACCOMMODATION LADDER SUPPORT.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987
Resolved
RENEW THE LOWER RUDDER PROTECTIVE SHEATING WHERE MISSING FOR THE #10 LIFEBOAT.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Accommodation/Occupational Safety
Issued 23 October 1987
Resolved
REMOVE FROM THE NUMBER SIX AND SEVEN HOLDS ALL DRUMS AND CONTAINERS OF GEAR OIL AND CORROSIVE LIQUIDS.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Accommodation/Occupational Safety
Issued 23 October 1987
Resolved
CLEAR ALL NON ESSENTIAL TRAINING EQUIPMENT AND OTHER COLLECTED MATERIALS (LOCKERS, SEATS, PORTABLE LIGHTING, NONSERVICED FIRE EXTINGUISHERS, ETC) FROM THE NUMBER SIX AND SEVEN HOLDS AND REMOVE SAME FROM VESSEL.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Accommodation/Occupational Safety
Issued 23 October 1987
Resolved
BROOM SWEEP CLEAN ALL CARGO HOLDS.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
PROPERLY MARK THE STERN WITH THE VESSEL'S HAILING PORT. (NOTE: LIFEBOATS ARE MARKED FOR NEW YORK, NY). THIS REQUIREMENT HAS BEEN RECINDED.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Electrical
Issued 23 October 1987
Resolved
REMOVE JURY RIGGED WIRING FROM ELECTRICAL OUTLET IN ELECTRICAL CLASSROOM.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 15 May 1987
Resolved
MAKE PERMANENT REPAIR TO PATCH ON #6 FUEL OIL DOUBLE BOTTOM IN SHAFT ALLEY.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Construction/Loadline
Issued 15 May 1987
Resolved
REPAIR REACH ROD FOR EDUCTOR SUPPLY VALVE IN AFTER FIRE PUMP ROOM.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Electrical
Issued 15 May 1987
Resolved
LOCATE AND STENCIL ALL EMERGENCY LIGHTS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Engineering
Issued 15 May 1987
Resolved
REPAIR SHAFT ALLEY BILGE SUCTION VALVE.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Construction/Loadline
Issued 15 May 1987
Resolved
MAKE PERMANENT REPAIRS IN WAY OF TEMPORARY REPAIR TO #6 HATCH, HATCH IS TO REMAIN IN A WATERTIGHT CONDITION TARP AND BATTENS IN PLACE.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Electrical
Issued 15 May 1987
Resolved
REPAIR FUEL LEAK ON AUXILIARY GENERATOR.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Construction/Loadline
Issued 26 March 1987
Resolved
MAKE PERMANENT REPAIRS TO THE CHAIN LINE THAT PENETRATES NOS. 3 AND 4 HOLDS
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Construction/Loadline
Issued 10 March 1987
Resolved
CROP AND RENEW TO GOOD METAL, DECK IN FAN ROOM PORTSIDE 02 DECK WHERE HOLED AND WASTED AT APPROXIMATELY FRAME 113.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Lifesaving
Issued 10 March 1987
Resolved
MAKE REPAIRS TO #6 LIFEBOAT BUOYANCY TANKS. VESSEL IS NOT TO GET UNDERWAY PRIOR TO COMPLETION AND TEST OF REPAIRS.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Lifesaving
Issued 19 May 1986
Resolved
PROVE PROPER OPERATION AND OPEN FOR INSPECTION THE AFT LIMIT SWITCH ON THE #9 LIFEBOAT.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Fire Fighting
Issued 19 May 1986
Resolved
PROVE PROPER OPERATION OF ZONITE ALARM BOX FOR ZONE #14.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Fire Fighting
Issued 19 May 1986
Resolved
MODIFY SMOKE DETECTION SYSTEM DIAGRAMS LOCATED ON THE BRIDGE AND AT THE SYSTEM'S CONTROL STATION TO REFLECT THE ACTUAL ONBOARD INSTALLATION.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Construction/Loadline
Issued 17 May 1985
Resolved
MAKE PERMANENT REPAIRS TO THE 2 PATCHED HOLES IN THE ENGINE ROOM TANKTOPS (LOCATIONS: UNDER THE STANBY FUEL OIL PUMP AND OUTBOARD AND FWD OF #3 AUX. CONDENSATE PUMP).
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Construction/Loadline
Issued 17 May 1985
Resolved
PERFORM GAGINGS OF ER TANKTOPS AFT OF BOTH BOILERS AFTER THOROUGH CLEANING OF TANKTOPS. AT LEAST 2 BELTS OF TRANSVERSE AND LONG'L GAGING SHALL BE CONDUCTED. ADD'L GAGINGS SHALL BE TAKEN IN CORRODED AREAS AND AREAS BELOW PUMPS, CONDENSATE DRAINS AND BLOWDOWNS.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Engineering
Issued 17 May 1985
Resolved
MAKE PERMANENT REPAIRS TO THE FUEL OIL LINE UNDER THE CATWALK AT THE FWD END OF THE SHAFT ALLEY.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Construction/Loadline
Issued 17 May 1985
Resolved
MAKE PERMANENT REPAIRS TO THE VOID/BALLAST TANK, VENT STBD SIDE AT THE AFT END OF SHAFT ALLEY. MARK/STENCIL IDENTITY OF VENT ON DECK (TEMP REPAIRS TO THE HOLD VENT LINE TO BE MADE IMMEDIATELY.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985