Records from 1999 to 2022. Most recent: inspection, 3 March 2022.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 September 2003
No resolution recorded
Prove proper operation of Oil Water Separator to the satisfaction of Class IAW MARPOL 73/78 REG 16(4)
Due 25 October 2003 — due date passed with no resolution recorded
Lifesaving › Lifeboat › Markings
Issued 22 September 2003
No resolution recorded
Ensure lifesaving appliances ( lifeboat) are fitted with retro-reflective material IAW LSA CODE 1.2.7
Due 25 October 2003 — due date passed with no resolution recorded
Engineering
Issued 22 September 2003
No resolution recorded
PROVIDE PROPER OPERATION OF HIGH PRESSURE FUEL LINE FAILURE ALARM TO THE SATISFACTION OF CLASS IAW SOLAS 74/78 CH II-2 REG 15.2.9
Due 25 October 2003 — due date passed with no resolution recorded
Lifesaving
Issued 11 April 2001
Resolved
Remove paint stored in forward winch room
Condition: Unknown
Due 11 May 2001
Resolved 25 September 2003
Construction/Loadline
Issued 11 April 2001
Resolved
Free CO2 room water tight door dogs.
Condition: Unknown
Due 11 May 2001
Resolved 25 September 2003
Lifesaving
Issued 11 April 2001
Resolved
Remve excess gear stored in CO2 room, main deck fire locker and after steering.
Condition: Unknown
Due 18 April 2001
Resolved 25 September 2003
Fire Fighting
Issued 11 April 2001
Resolved
Renew holed GS piping near GS pump._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 May 2001
Resolved 25 September 2003
Documentation
Issued 11 April 2001
Resolved
Provide dangerous goods manifest for dangerous goods.
Condition: Unknown
Due 11 May 2001
Resolved 25 September 2003
Fire Fighting
Issued 11 April 2001
Resolved
Repair or replace leaking fire hose near aft crane.
Condition: Unknown
Due 11 May 2001
Resolved 25 September 2003
Lifesaving
Issued 11 April 2001
Resolved
Properly store deck cargo._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 May 2001
Resolved 25 September 2003
Lifesaving
Issued 11 April 2001
Resolved
Provide grease trap for galley.
Condition: Unknown
Due 11 May 2001
Resolved 25 September 2003
Fire Fighting
Issued 11 April 2001
Resolved
Prove proper operations of torch for fireman's outfit.
Condition: Unknown
Due 11 May 2001
Resolved 25 September 2003
Electrical
Issued 11 April 2001
Resolved
Install light cover in #2 firelocker.
Condition: Unknown
Due 11 May 2001
Resolved 25 September 2003
Lifesaving
Issued 11 April 2001
Resolved
Remove hold backs from firedoors in stairwell.
Condition: Unknown
Due 11 May 2001
Resolved 25 September 2003
Documentation
Issued 11 April 2001
Resolved
Pre-arrival tests were not logged.
Condition: Unknown
Due 11 May 2001
Resolved 25 September 2003
Fire Fighting
Issued 26 August 1999
Resolved
Conduct fire drill to satisfaction of USCG marine inspector prior to departure.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Fire Fighting
Issued 26 August 1999
Resolved
Provide fire hoses on station (hoses have been removed from fire hose boxes).
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Lifesaving
Issued 26 August 1999
Resolved
Provide lights and smoke for ring life buoys. (w/l and smokes missing from bridge wing and w/l missing throughout vessel)
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Engineering
Issued 26 August 1999
Resolved
Provide plugs for oil containment drains.
Condition: Unknown
Due 20 June 2001
Resolved 23 July 2001
Engineering
Issued 26 August 1999
Resolved
Remove garbage and other gear stored in oil containment. (garbage was found inside fuel/oil containment, gear was stored inside containment as well)
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Fire Fighting
Issued 26 August 1999
Resolved
Remove stores from CO2 room.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Navigation
Issued 26 August 1999
Resolved
Provide current light list for American Samoa.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Lifesaving
Issued 26 August 1999
Resolved
Provide two additional ring buoys for a total of ten.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Navigation
Issued 26 August 1999
Resolved
Provide current coast pilot for American Samoa.
Condition: Unknown
Due 20 June 2001
Resolved 23 July 2001
Lifesaving
Issued 26 August 1999
Resolved
Provide SOLAS training manual in crew's messroom or each crew's cabin.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Fire Fighting
Issued 26 August 1999
Resolved
Provide fixed firefighting or fire-extinguishing appliances to the satisfaction of class or administration for the paint locker.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Fire Fighting
Issued 26 August 1999
Resolved
Provide muster list in a language understandable by all crew and officers._x001C_Muster list is in English, but 2nd mate could not read English.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001