MAURY USCG vessel records Sign in
← All vessels

GAZ BARAKA

GAZ BARAKA is a 1984 tank ship. The Coast Guard has recorded 17 inspections since 2001, most recently in May 2009, along with 6 deficiencies and 8 operational controls, 2 with no removal date recorded.

Records from 2001 to 2009. Most recent: inspection, 14 May 2009.

Built
1984
Last inspected
14 May 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
2 with no removal date recorded

Identity

8323173 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
413772
Flag
JAPAN
—
Maury page id
psix-413772

Inspections, by type

…with no type recorded7
Years with a record 7 calendar years (2001–2009)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9211 - Convention (Subpart B), Net Ton
24947 - Dead Weight, Ton
24387 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

14 May 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3469545
11 February 2008 MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3145829
10 February 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3144945
7 February 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3143335
9 February 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2869881
8 February 2007 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2870656
2 February 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2866222
1 February 2007 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2865496
12 January 2006 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2567860
6 January 2006 ISPS II Exam · Ballast Water Examination · COC-GAS Renew · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2561991
5 January 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2561251
5 July 2004 ISPS II Exam · COC-GAS Annual
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2123055
4 September 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1899696
2 July 2003 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1839441
1 July 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1833084
10 May 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 289960
10 May 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1064446

Deficiency record · 6

Lifesaving › Lifeboat › Handholds/Handrails
Issued 1 February 2007 Resolved
Both lifeboats have brackets broken on their underbody handrails used in self-righting the boats. The handrail are on the outboard side of each boat. Class must fax in report to office.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 February 2007
Resolution: Received class report stating that handrails have been satisfactorily renewed.
Construction/Loadline › Markings › Fresh Water Load Line
Issued 1 February 2007 Resolved
Vessel's fresh water load line was submerged on arrival. It was determined that this condition resulted from a disparity between actual condition (sagging) and condition calculated by a stability calculation computer program (hogging). Class to address disparity in calculations.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2007
Resolution: Received class report which identified bad information input to stability calculations as source of disparity. Inputs corrected and accurate stability calculations provided.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 1 February 2007 Resolved
Vessel's gas detection system audible high LEL alarm sounds at 35% LEL. IGC requires alarm to sound at 30% LEL.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2007
Resolution: Received class report stating that gas detection alarm point had been set to 30%LEL.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 6 January 2006 Resolved
Vessel cannot maintain inert gas levels below 8% oxygen by volume in the interbarrier spaces. To be corrected prior to allowing the vessel to enter the Port of Hampton Roads.
Action required: 705 - Other - as specified
Due 14 January 2006
Resolved 13 January 2006
Resolution: The inert gas oxygen sensor was cleaned by the crew. The attending surveyor (BV) verified the calibration of the inert gas oxygen. The content of the interbarrier void spaces was found to be within acceptable limits.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 6 January 2006 Resolved
Soft patch located at the lower right corner of doorway entrance to compressor room. Does not meet structural fire integrity in accordance with IGC 3.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2006
Resolved 13 February 2006
Resolution: Recieved class report stating that soft patch was permanently repaired with a steel plate.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 2 July 2003 Resolved
Deck water spray system had several clooged nozzles resulting in inadequate firefighting coverage, especially in superstructure area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2003
Resolved 2 July 2003
Resolution: Conducted satisfactory test of deck spray system.

Ownership record