The 4 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for EUROPA SUPPLIER I, retrieved 18 September 2026. mauryrecords.com/v/psix-413930.html
Documentation record
Tonnage as PSIX records it1816 - Convention (Subpart B), Net Ton 6403 - Dead Weight, Ton 9029 - Displacement, Ton 4270 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 4
22 March 2006Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2607328
3 March 2006COC-TVE Renew · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2594647
2 March 2006Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2595336
1 March 2006Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2595024
The fire main pipe in the deck tunnel has a 1/2" crack near the isolation valve by P-4 temperature sensor. Make permanent repairs to the satisfaction of class.
Action required: 705 - Other - as specified
Due 10 March 2006
Resolved 22 March 2006
Resolution: Received Class report from GL satisfying requirement.
Engineering › Bilge Water Management System › Piping
Issued 3 March 2006Resolved
In the Cargo Pump Room the port and stbd ballast stripping eductor pipes near the overboard valves have temporary patches. Make repairs to the satisfaction of class.
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 22 March 2006
Resolution: Received Class report from GL satisfying requirement.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 3 March 2006Resolved
In the Cargo Pump Room the port and stbd ballast stripping eductor pipes near the overboard valves have temporary patches. Make repairs to the satisfaction of class.
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 22 March 2006
Resolution: Received Class report from GL satisfying requirement.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.