MAURY USCG vessel records Sign in
← All vessels

AQUALAB III

AQUALAB III is a 1957 school ship. The Coast Guard has recorded 37 inspections since 1985, most recently in September 1996, along with 37 deficiencies.

Records from 1985 to 1996. Most recent: inspection, 3 September 1996.

Built
1957
Last inspected
3 September 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-41396

Inspections, by type

…with no type recorded10
Years with a record 12 calendar years (1985–1996)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it405 - Regulatory (Subpart C or D), Gross Ton
316 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 37

3 September 1996 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 940483
19 March 1996 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 886324
21 February 1996 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1192596
17 November 1995 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1185680
13 September 1995 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1385570
5 April 1995 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1148655
22 March 1995 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 826611
17 March 1995 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 867630
21 February 1995 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 846565
21 September 1994 Damage Survey
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1181343
20 September 1994 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1180229
25 April 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1168248
23 March 1994 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1167933
19 January 1994 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 850646
5 November 1993 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 831331
13 May 1993 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1140777
7 October 1992 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 940050
14 September 1992 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1253200
9 April 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 957381
30 October 1991 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 942919
24 September 1991 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1248334
19 April 1990 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1225193
16 August 1989 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1038412
27 July 1989 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1345763
16 December 1988 Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 899252
14 March 1988 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1025719
12 November 1987 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1329886
31 March 1987 Damage Survey
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1020223
16 March 1987 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1322916
4 September 1986 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1015156
31 March 1986 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1307089
28 February 1986 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 992500
28 February 1986 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 992627
3 October 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 992678
12 June 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1292118
25 March 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 979848
25 March 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1288123

Deficiency record · 37

Lifesaving
Issued 13 September 1995 Resolved
STUDENTS MAY NOT REMAIN ABOARD THE VESSEL WITHOUT THE FULL CREW AFTER NORMAL SCHOOL HOURS (1600) WITHOUT THE EXPRESSED WRITTEN PERMISSION OF OCMIPORTLAND AND CONCURRENCE FROM THE CURRICULUM MANAGER (BOSTON)
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Lifesaving
Issued 13 September 1995 Resolved
SERVICE ALL LIFERAFTS NOT LATER THAN 06 FEB 96
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Engineering
Issued 13 September 1995 Resolved
REPAIR OVERHEATING AND OIL PRESSURE PROBLEMS ON #1 M/E. THE VESSEL IS ALLOWED U/W FOR TRIALS ONLY TO TROUBLE-SHOOT AND VALIDATE REPAIRS WITHOUT STUDENTS ABOARD. STUDENTS WILL NOT BE ALLOWED ABOARD THE VESSEL IF THIS ITEM IS NOT CORRECTED PRIOR TO 10 OCT 95.
Condition: Unknown
Due 10 October 1995
Resolved 1 November 1995
Electrical
Issued 13 September 1995 Resolved
REPLACE/RENEW MISSING LIGHT GLOBE AND GUARD TO OVHD LIGHT IN MESS DECK.
Condition: Unknown
Due 10 October 1995
Resolved 21 September 1995
Navigation
Issued 13 September 1995 Resolved
EXTEND CLEVIS PIN IN STEERING SYSTEM FEED BACK LLINKAGE TO FULLY ENGAGE THROUGH BOTH SIDES OF FORK. CORRECT PRIOR TO CARRYING STUDENTS U/W.
Condition: Unknown
Due 30 September 1995
Resolved 21 September 1995
Construction/Loadline
Issued 13 September 1995 Resolved
CLEAN BILGE STRAINER IN FWD BERTHING
Condition: Unknown
Due 30 September 1995
Resolved 21 September 1995
Fire Fighting
Issued 13 September 1995 Resolved
CONDUCT FIRE AND BOAR DRILLS TO SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 October 1995
Resolved 17 November 1995
Construction/Loadline
Issued 13 September 1995 Resolved
MAKE FINAL REPAIRS TO BOTH MACHINERY SPACE HATCHES AND PROVIDE PROPER T- HANDLES. THIS VESSEL WILL NOT BE ALLOWED TO CARRY STUDENTS ABOARD IF NOT CORRECTED BY 30 SEP 95
Condition: Unknown
Due 30 September 1995
Resolved 21 September 1995
Engineering
Issued 13 September 1995 Resolved
REPAIR RELIEF VALVE ON THE LOWER AIR RECEIVER IN THE E/R.(LEAKS). THIS AIR RECEIVER IS NOT TO BE PRESSURIZED UNTIL A NEW RELIEF VALVE IS INSTALLED ANDTESTED IN PRESENCE OF THE ATTENDING MARINE INSPECTOR. THE VESSEL WILL NOT BE ALLOWED TO CARRY STUDENTS ABOARD NOT CORRECTED BY 10 OCTOBER 95.
Condition: Unknown
Due 10 October 1995
Resolved 1 November 1995
Engineering
Issued 13 September 1995 Resolved
REPLACE TWO SHORT STUDS IN THE THE UPPER AIR RECEIVER R.V. FLANGE IN E/R. CORRECT WITH LONGER STUDS, OF PROPER TYPE. THE VESSEL WILL NOT BE ALLOWED TO CARRY STUDENTS ABOARD IF NOT CORRECTED BY 10 OCT 95.
Condition: Unknown
Due 10 October 1995
Resolved 1 November 1995
Engineering
Issued 13 September 1995 Resolved
PROPERLY LAG M/E TURBO CHARGER EXHAUST VOLUTES AND DISCHARGE PIPING. THE VESSEL WILL NOT BE ALLOWED TO CARRY STUDENTS ABOARD IF NOT CORRECTED BY _x001C_ 10 OCT 95.
Condition: Unknown
Due 10 October 1995
Resolved 1 November 1995
Engineering
Issued 17 March 1995 Resolved
REMOVE EXCESSIVE FUEL/OIL FROM GENERATOR BILGES AND MAKE PERMANENT REPAIRS TO SOFT PATCHES 2" FUEL LINE UNDER SWITCHBOARD. GENERATORS AND BOILERS NOTE TO BE OPERATED UNTIL CORRECTED.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Lifesaving
Issued 17 March 1995 Resolved
REMOVE EXCESSIVE OIL FROM ENGINEROOM BILGES PRIOR TO OPERATING MAIN ENGINES, ONCE CLEANED THEN ONE STUDENT PER [name withheld] STUDENT PER LIC. ENG. WILL BE PERMITTED IN THE ENGINEROOM DURING DOCK TRIALS.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Engineering
Issued 21 September 1994 Resolved
CONDUCT SATISFACTORY U/W TEST OF OVERHAULED MAIN ENGINES. TO BE DONE PRIORTO CARRYING STUDENTS, IN THE PRESENSE OF A MARINE INSPECTOR
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Electrical
Issued 23 March 1994 Resolved
INSTALL REMOTE SHUT DOWN FOR FUEL OIL PURIFIER.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Construction/Loadline
Issued 23 March 1994 Resolved
STRIP ENGINEROOM AND GENERATOR ROOM BILGES.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Construction/Loadline
Issued 23 March 1994 Resolved
RENEW DETERIORATED GASKETS FOR WTD'S, WTS'S, WTH'S.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Electrical
Issued 23 March 1994 Resolved
INSTALL EMERGENCY LIGHTING FOR LIFE RAFTS.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Engineering
Issued 23 March 1994 Resolved
PROVIDE WELD PROCEDURES FOR BOILER REPAIRS.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Electrical
Issued 23 March 1994 Resolved
REPAIR BOW LOOKOUT SOUND POWERED PHONE CIRCUIT.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Electrical
Issued 23 March 1994 Resolved
INSTALL PERMANENT CHARGING SYSTEM FOR GENERATOR BATTERIES.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Electrical
Issued 23 March 1994 Resolved
INSTALL PERMANENT CHARGING SYSTEM FOR GENERAL ALARM BATTERIES.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Engineering
Issued 23 March 1994 Resolved
REPAIR INOPERABLE GAGES IN ENGINE ROOM.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Engineering
Issued 23 March 1994 Resolved
INSTALL FUEL OIL TANK REMOTE SHUT-OFF VALVES IAW 46 CFR 56.50-60(d)(1).
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Deck/Cargo
Issued 23 March 1994 Resolved
PROVIDE SAFE WORKING LOAD FOR STERN DAVIT AND GUARDS OVER WINCH AND PUMP.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Accommodation/Occupational Safety
Issued 23 March 1994 Resolved
INSTALL VENT SCREENS IN VENT DUCT OVER GRILL.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Accommodation/Occupational Safety
Issued 23 March 1994 Resolved
REPAIR NON-FUNCTIONING WATER CLOSET.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Documentation
Issued 23 March 1994 Resolved
PROVIDE FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Fire Fighting
Issued 23 March 1994 Resolved
CONDUCT FIRE AND BOAT DRILLS.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Navigation
Issued 23 March 1994 Resolved
REPAIR RUDDER ANGLE INDICATOR LOSS OF POWER ALARM.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Engineering
Issued 13 May 1993 Resolved
REPAIR/REPLACE VESSEL'S PROPELLERS. ENGINE RPM'S LIMITED TO 1000 UNDER NORMAL OPERATING CONDITIONS (UNDERWAY HRS LIMITED TO 250 PER YEAR).
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Engineering
Issued 13 May 1993 Resolved
MASTER OF VESSEL WILL IMMEDIATELY NOTIFY THE COGNIZANT [name withheld] PROPELLER SHAFT VIBRATION IS NOTED.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Engineering
Issued 24 September 1991 Resolved
PROVIDE PERSONNEL GUARDS FOR BELT DRIVES ON FRONT OF EACH MAIN ENGINE.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Engineering
Issued 24 September 1991 Resolved
PROVE PROPER OPERATION OF AFT SHIPS BOILER.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Electrical
Issued 24 September 1991 Resolved
PROVE MAIN ENGINE L/O AND HIGH TEMP ALARMS ARE OPERATIONAL AND FREE OF ELECTRICAL SHOCK HAZARDS.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Lifesaving
Issued 19 April 1990 Resolved
ELEVEN (11) ADULT PFD'S TO BE OBTAINED PRIOR TO CARRYING MORE THAN SIXTY- NINE (69) PERSON AND NOT LATER THANT 20 MAY 1990.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Accommodation/Occupational Safety
Issued 19 April 1990 Resolved
TYPE III MSD HOLDING TANKS TO BE INSTALLED NO LATER THAN 20 MAY 1990. VESSEL TO PROVIDE PORTA-POTTY FACILITY UNTIL NEW TANKS INSTALLED.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990

Ownership record