Records from 1993 to 2006. Most recent: inspection, 24 January 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 47
24 January 2006
In-Service Inspection · Drydock Extension
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2572331
2 November 2005
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2529974
4 October 2005
Periodic Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2506991
5 April 2005
In-Service Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2326774
5 April 2005
In-Service Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2334086
27 January 2005
In-Service Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2281614
24 September 2004
Annual Inspection · Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2173923
27 April 2004
In-Service Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2116413
11 September 2003
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1912509
2 September 2003
Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1886514
17 June 2003
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1840654
29 May 2003
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1804149
11 March 2003
Drydock Extension
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1755881
13 January 2003
Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1729457
29 October 2002
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1697730
17 September 2002
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1676723
17 September 2002
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1697587
3 April 2002
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1600520
10 September 2001
Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1384889
8 August 2001
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1395792
31 May 2001
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1066113
24 May 2001
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1065642
28 March 2001
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 188184
4 September 2000
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 822624
28 August 2000
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1410390
12 May 2000
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 817976
13 March 2000
Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1442975
3 September 1999
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1461200
6 July 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 211918
10 February 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1472966
1 September 1998
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1458560
16 September 1997
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1375111
8 September 1997
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 786524
25 August 1997
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 780247
25 August 1997
Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1446531
25 March 1997
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1101353
7 March 1997
Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1402366
22 January 1997
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1099692
22 January 1997
Drydock Extension
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1443787
9 September 1996
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1435804
13 August 1996
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1095525
9 May 1996
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1088107
1 April 1996
Initial Certification
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1409061
14 November 1995
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 881677
13 October 1995
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 879353
5 November 1993
Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1144708
12 June 1993
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 845346
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 24 January 2006
Resolved
Prove proper operation of fixed gas fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2006
Resolution: Time delay removed, new pipe section inserted, system tested - sat.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 4 October 2005
Resolved
Replace ground detection light bulbs and prove proper operation of ground detection on distribution panel board in the engine control room.
Due 4 November 2005
Resolved 2 November 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 4 October 2005
Resolved
Repair/Replace broken RPM gauge at control station.
Due 4 November 2005
Resolved 2 November 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 January 2005
Resolved
Prove proper operation of time delay.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2005
Resolution: New delay installed and tested sat.
Electrical › Electrical Distribution System (service) › Cable
Issued 24 September 2004
Resolved
Pull or propperly dead end cable in pilot house, under dash board, behind wheel.
Due 29 October 2004
Resolved 26 October 2004
Resolution: All dead end cables removed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 September 2004
Resolved
Replace electrical recptacle in engine room, in way of fuel tank, with approved type for machinery spaces.
Due 14 October 2004
Resolved 12 October 2004
Resolution: Receptacle renewed.
Engineering › Bilge Water Management System › Valve
Issued 24 September 2004
Resolved
Label bilge cut off valve for fore peak space.
Due 14 October 2004
Resolved 12 October 2004
Resolution: Valve properly labeled.
Navigation › Piloting/Steering
Issued 2 September 2003
Resolved
Provide a current light list on board the vessel. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Due 2 October 2003
Resolved 11 September 2003
Resolution: A new light list was placed on board.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 September 2003
Resolved
Renew stbd side stanchion aft side of gangway and the port side stanchion forward of the gangway. LEGACY COMPONENT DESC: Storm Rail
Condition: Improper/Lack of Maintenance
Due 2 October 2003
Resolved 6 October 2003
Resolution: Examined installation of new stanchions on railings iwo embarkation openings - all sat.
Engineering › Bilge Water Management System
Issued 2 September 2003
Resolved
Renew strainer in bilge suction of plankton lab. LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Due 2 October 2003
Resolved 17 September 2003
Resolution: New strainer properly installed.
Stability › Watertight Integrity
Issued 2 September 2003
Resolved
Prove operation of galley escape hatch dogging mechanism. (Frozen open)
Condition: Improper/Lack of Maintenance
Due 7 September 2003
Resolved 8 September 2003
Resolution: Lubricated and functioning properly.
Construction/Loadline › Structures
Issued 2 September 2003
Resolved
Mark the excape hatches in the plankton lab and galley space with the words "Emergency Exit, Keep Clear" on both the inside and outside. LEGACY COMPONENT DESC: Scuttle
Condition: Placed in Improper Service
Due 11 September 2003
Resolved 11 September 2003
Resolution: Escape hatches properly labeled.
Documentation › Manuals/Policy Documentation
Issued 2 September 2003
Resolved
Post a station billl that sets forththe special duties and duty stations of each crew member for various emergencies.
Condition: Placed in Improper Service
Due 9 October 2003
Resolved 8 October 2003
Resolution: Rcvd copy of a satisfactory station bill by fax.
Construction/Loadline › Hull
Issued 12 May 2003
Resolved
Fill in cuts at frame #18 on stringer, toe of floor frame, and frame #18 with an appropriate marine filler (epoxy). LEGACY COMPONENT DESC: Stringer
Due 26 May 2003
Resolved 29 May 2003
Resolution: These gouges in the structural members had been filled or coated with an epoxy compound (West 105/205 epoxy and filler).
Engineering › Fuel Oil Service System
Issued 12 May 2003
Resolved
Provide proof that copper tubing used in fuel line has a minimum wall thickness of 0.035". LEGACY COMPONENT DESC: Piping
Due 26 May 2003
Resolved 29 May 2003
Resolution: Received distributer documentation attesting to the wall thickness of the tubing.
Engineering › Fuel Oil Service System
Issued 12 May 2003
Resolved
Secure copper fuel piping against movement and vibration. Chafing gear installed above deck but not below deck plating. Requirement is extended to 13 Jun 03. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 13 June 2003
Resolved 17 June 2003
Resolution: Examined installation of copper fuel lines. Both lines were properly secured against movement and vibration with rubber lined copper straps.
Electrical › Electrical Distribution System (service)
Issued 12 May 2003
Resolved
Renew missing cover on junction box in bilge of officer country passageway. LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Due 26 May 2003
Resolved 29 May 2003
Resolution: A cover had been installed on the junction box.
Deck/Cargo › Mooring/Anchoring
Issued 12 May 2003
Resolved
Renew anchor chain. LEGACY COMPONENT DESC: Anchor Chain (general)
Condition: Improper/Lack of Maintenance
Due 26 June 2003
Resolved 10 July 2003
Resolution: New line and tackle installed - sat.
Lifesaving › Lifebuoys
Issued 17 September 2002
Resolved
REPLACE LINE ON LIFERING. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2002
Resolved 17 September 2002
Resolution: RENEWED LIFERING.
Engineering › Bilge Water Management System
Issued 17 September 2002
Resolved
REPAIR/REPLACE ENGINE ROOM HIGH LEVEL ALARM SENSOR. WHEN UNDERWAY WITH PASSENGERS ENGINE ROOM SHALL BE MANNED WITH DIRECT COMMUNICATIONS TO THE BRIDGE. LEGACY COMPONENT DESC: Interface Detector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2002
Resolved 17 October 2002
Resolution: RENEWED SENSOR, TESTED SAT.
Electrical › Lighting (emergency)
Issued 17 September 2002
Resolved
REPAIR/REPLACE GALLEY EMERGENCY LIGHT. PROVIDE FLASHLIGHT IN GALLEY UNTIL COMPLETED. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2002
Resolved 24 September 2002
Resolution: REPAIRED EXISTING LIGHT.
Lifesaving
Issued 8 August 2001
Resolved
PROVIDE 3 RED FLARES WITH CURRENT EXPIRATION DATES.
Condition: Unknown
Due 22 August 2001
Resolved 20 August 2001
Lifesaving
Issued 8 August 2001
Resolved
MAKE PASSENGER COUNT PERMITTED ON 2ND DECK VISIBLE.
Condition: Unknown
Due 22 August 2001
Resolved 20 August 2001
Lifesaving
Issued 8 August 2001
Resolved
INSTALL PFD DONNING PLACARD 2ND DECK.
Condition: Unknown
Due 22 August 2001
Resolved 20 August 2001
Fire Fighting
Issued 8 August 2001
Resolved
REPLACE GASKET FORWARD FIRE STATION.
Condition: Unknown
Due 22 August 2001
Resolved 20 August 2001
Electrical
Issued 8 August 2001
Resolved
REPAIR/RECHARGE BATTLE LANTERN IN ENGINE ROOM.
Condition: Unknown
Due 22 August 2001
Resolved 20 August 2001
Lifesaving
Issued 8 August 2001
Resolved
RESTENCIL PFD LOCKERS WITH COUNT.
Condition: Unknown
Due 22 August 2001
Resolved 20 August 2001
Engineering
Issued 31 May 2001
Resolved
REINSTALL SIGHT GLASS ON FUEL TANK.
Condition: Unknown
Due 14 June 2001
Resolved 11 June 2001
Engineering
Issued 24 May 2001
Resolved
CLEAN, PUMP AND VENTILATE BILGES DUE TO FUEL SPILL, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Lifesaving
Issued 28 August 2000
Resolved
PROVIDE LIFEJACKET DONNING PLACARD
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Lifesaving
Issued 28 August 2000
Resolved
PROVIDE DOCUMENTATION THAT WATER LIGHT IS A COAST GUARD APPROVED MODEL.
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Lifesaving
Issued 3 September 1999
Resolved
REPLACE ALL LIFERINGS ABOARD THE VESSEL.
Condition: Unknown
Due 10 September 1999
Resolved 14 September 1999
Construction/Loadline
Issued 22 January 1997
Resolved
REPLACED CRACKED BUTT BLOCK LOCATED AT FRAME 27, STBD SIDE, BELOW OFFICERS STATEROOM FLOOR.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Engineering
Issued 22 January 1997
Resolved
REPLACE AS NECCESSARY ANY DAMAGED WOOD AND OR FASTENERS IN VICINITY OF STBDSTRUT BACKING BLOCK, LOCATED IN LAZERETTE, AND AT THE STBD SHAFT STUFFING TUBE LOCATED IN CREWS WORK SHOP/GALLEY SPACE.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Engineering
Issued 22 January 1997
Resolved
DETERMINE THE CAUSE OF AND CORRECT THE GALVANIC CORROSION FOUND AT STBD STERN TUBE AND STBD STRUT ATTACHMENT POINT.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Construction/Loadline
Issued 1 April 1996
Resolved
IN FWD MAIN DECK AREA, REMOVE DECK COVERING AND REPLACE ANY DETERIORATED WOOD DECKING, RECOVER DECK WITH SUITABLE WATERPROOF MATERIAL.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Construction/Loadline
Issued 1 April 1996
Resolved
TEMPORARY REPAIRS TO FWD DECK AREA TO CONSIST OF WATERPROOFING THE DECK AREA AND REMOVING THE OVERHEAD INSULATION IN THE FWD CABIN TO ALLOW CLOSER INSPECTION OF DECK AND TO ALLOW IT TO DRY OUT.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996