Records from 1996 to 1997. Most recent: inspection, 23 September 1997.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
23 September 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 408187
16 December 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 721151
15 December 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 398514
9 December 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 397995
2 December 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 62687
Accommodation/Occupational Safety
Issued 23 September 1997
No resolution recorded
Missing numerous lower and center guardrails from midship forward on main deck, port and stbd side. Repair to the satisfaction of Class Society (NKK) prior to next U.S. port.
Condition: Unknown
Due 23 October 1997 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 9 December 1996
Resolved
VESSEL DOES NOT HAVE A HOSPITAL SPACE. (ILO 147) PROVIDE/INSTALL PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 2 January 1997
Resolved 16 January 1997
Lifesaving
Issued 9 December 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 December 1996
Resolved 12 December 1996
Fire Fighting
Issued 9 December 1996
Resolved
DOOR PORT SIDE BETWEEN GALLEY AND MAIN PASSAGE WAY THAT LEADS TO ENGINE ROOM IS MISSING A DOG/HANDLE. (ILLC 66 ANNEX 1 REG. 12). CORRECT PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 9 December 1996
Resolved 12 December 1996
Engineering
Issued 9 December 1996
Resolved
BILGE PUMP LOCATED IN ENGINE ROOM STARBOARD SIDE. ROTATING GEARS IS MISSINGGUARDS. (SOLAS 74 AMENDED CHAPTER II REG. 1/26.1). INSTALL MACHINERY GUARDSPRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 9 December 1996
Resolved 12 December 1996
Accommodation/Occupational Safety
Issued 9 December 1996
Resolved
VESSEL DOES NOT HAVE A MARINE SANITATION DEVICE. (33 C.F.R. PART 159.7)_x001C_ INSTALL PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Navigation
Issued 9 December 1996
Resolved
VESSEL REQUIRED TO HAVE THREE TWO WAY VHF RADIOS. ONE EACH VHF RADIO IS MISSING. (SOLAS 74 AMENDED CHAPTER III REG. 6.2.1) CORRECT PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Navigation
Issued 9 December 1996
Resolved
VESSEL DOES NOT HAVE CURRENT NOTICE TO MARINERS. (33 C.F.R. 33.3.(c) PROVIDE CURRENT NOTICE TO MARINERS FOR TRANSITING AREA PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 9 December 1996
Resolved 12 December 1996
Lifesaving
Issued 9 December 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 December 1996
Resolved 12 December 1996
Lifesaving
Issued 9 December 1996
Resolved
VESSEL LIFE BOUYS LIGHTS PORT AND STBD SIDE NOT APPROPIATELY STOWED IN BRACKETS. (SOLAS 60 CHAPTER III REG. 21(e)(g). CORRECT PRIOR TO DEPARTURE._x001C__x001C_ _x001C_
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Fire Fighting
Issued 9 December 1996
Resolved
REPAIR DOOR THAT LEADS TO BATTERY SPACE NEAR STACK. (ILLC 66 ANNEX 1 REG. 12). CORRECT PRIOR TO DEPARTURE._x001C_
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996