MAURY USCG vessel records Sign in
← All vessels

WATERSIDE

WATERSIDE is a 1949 tank barge. The Coast Guard has recorded 22 inspections since 1985, most recently in April 1998, along with 16 deficiencies.

Records from 1985 to 1998. Most recent: inspection, 10 April 1998.

Built
1949
Last inspected
10 April 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-41406

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (1985–1998)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it1054 - Regulatory (Subpart C or D), Gross Ton
1054 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

10 April 1998 Uninspected Other
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1364704
27 May 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1149933
27 May 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 950544
10 March 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 953923
20 June 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245251
20 June 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1248116
20 June 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249410
10 January 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 922415
1 February 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 903792
4 January 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 914986
30 May 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1038085
13 March 1989 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1343360
9 January 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1044987
19 December 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036266
22 April 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039843
15 April 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036515
4 November 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329072
17 August 1987 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030471
17 August 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339382
3 September 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 965070
21 August 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1272946
13 September 1985 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1297610

Deficiency record · 16

Construction/Loadline
Issued 27 May 1992 Resolved
MAKE PERMANENT REPAIRS TO INTERNAL STRUCTURAL SUPPORT FRAMES #1 THRU #10 INTHE #3 BOTTOM VOID. VESSEL MAY CARRY PRODUCT BUT IS NOT TO MOVE FROM ITS W59TH ST MOORING.
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Deck/Cargo
Issued 10 March 1992 Resolved
PROPERLY CLEAN ALL GOOSENECK FLAME SCREENS AND REPLACE FLAME SCREEN ON #4 STBD CARGO TANK. TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Deck/Cargo
Issued 10 March 1992 Resolved
REPAIR LEAK IN WAY OF DRESSER COUPLING IN PORT PUMP ROOM STAIRWELL. TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Deck/Cargo
Issued 10 March 1992 Resolved
PROVE PROPER OPERATION OF LOW LEVEL SUCTION VALVE REACH ROD. TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Deck/Cargo
Issued 10 March 1992 Resolved
REPLACE COVER OF AMIDSHIPS PRESSURE GAGE ON DECK. TO BE COMPLETED TO THE SATISFACTION AN THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Deck/Cargo
Issued 20 June 1991 Resolved
PROVE PROPER OPERATION OF REMOTE SHUTDOWN FOR PORT CARGO PUMP.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Deck/Cargo
Issued 10 January 1991 Resolved
PROVE PROPER OPERATION OF PORT CARGO PUMP.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Electrical
Issued 4 January 1990 Resolved
REMOVE PORTABLE ELECTRICAL WIRING FROM OPEN DECK WHICH WAS USED FOR OUT OF SERVICE CARGO LEVEL ALARMS.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Deck/Cargo
Issued 4 January 1990 Resolved
PROVE PROPER OPERATION OF REMOTE SHUTDOWNS TO PORT AND STARBOARD CARGO PUMPS.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Deck/Cargo
Issued 9 January 1989 Resolved
PROVE PROPER OPERATION OF EMERGENCY ELECTRICAL SHUTDOWN FOR PORT CARGO PUMPPUMP SHALL NOT BE USED UNTIL REPAIRED AND TEST IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Deck/Cargo
Issued 9 January 1989 Resolved
REMOVE ALL OIL AND WATER FROM BILGES IN PUMP ROOM.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Electrical
Issued 9 January 1989 Resolved
REPLACE FRAYED WIRE STARBOARD SIDE AMIDSHIPS AT ELECTRICAL JUNCTION BOX.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Accommodation/Occupational Safety
Issued 9 January 1989 Resolved
REPLACE OR REMOVE DAMAGED RAIL STANCHION AT GANGWAY ENTRANCE TO VESSEL STARBOARD SIDE.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Electrical
Issued 9 January 1989 Resolved
REPLACE NON-EXPLOSION PROOF LIGHTS IN PUMP ROOM OVERHEAD WITH EXPLOSION PROOF LIGHTS OR REMOVE LIGHTS ENTIRELY FROM SPACE.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Construction/Loadline
Issued 15 April 1988 Resolved
PRIOR TO LOADING REGULATED CARGOS CROP AND RENEW ALL BOTTOM TRANSVERSE FRAMES AND WASTED CONNECTING CORNER BRACKET LOCATED IN NUMBER 3 AND 4 DOUBLE BOTTOMS.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Deck/Cargo
Issued 17 August 1987 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY ELECTRICAL SHUTDOWN FOR BOTH CARGO PUMPS.
Condition: Unknown
Due 17 August 1987
Resolved 17 August 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.