MAURY USCG vessel records Sign in
← All vessels

GRAND VICTORIA

GRAND VICTORIA is a 1994 passenger vessel (inspected). The Coast Guard has recorded 126 inspections since 1994, most recently in January 2016, along with 165 deficiencies and 10 casualty investigations between 2005 and 2007.

Records from 1994 to 2016. Most recent: inspection, 28 January 2016.

Built
1994
Last inspected
28 January 2016
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

414166
Flag
UNITED STATES
—
Maury page id
psix-414166

Inspections, by type

…with no type recorded30
Years with a record 17 calendar years (1994–2016)
The 126 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)364.8 ft × 100.0 ft × 7.8 ft
Registered tonnagegross 4,051 / net 3,986
ITC dimensions (L × B × D)364.8 ft × 100.0 ft × 7.8 ft
ITC tonnagegross 10,891 / net 3,267
BuilderWATCH CITY SHIPYARD INC. · ELGIN, IL, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portELGIN, IL
Trade endorsementsRegistry
DocumentationValid · issued 11 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4051 - Regulatory (Subpart C or D), Gross Ton
10891 - Convention (Subpart B), Gross Ton
3986 - Regulatory (Subpart C or D), Net Ton
3267 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 126

28 January 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5804974
30 December 2009 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3656630
17 December 2009 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3651676
11 December 2009 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3649770
23 July 2009 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3544671
2 April 2009 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3435013
13 January 2009 Periodic Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3393344
2 December 2008 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3372582
2 December 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3372690
10 October 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3342201
15 September 2008 DAPI Audit · MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3315800
24 July 2008 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3278004
30 June 2008 Re-Inspection · Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3238873
22 April 2008 Deficiency Check · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3189711
17 March 2008 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3164625
16 January 2008 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3130267
17 September 2007 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3054316
17 September 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3072702
2 July 2007 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2977899
6 April 2007 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2898492
1 February 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2869131
24 January 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2861098
18 January 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2880663
16 January 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2856518
21 October 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2830168
17 October 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2831482
20 September 2006 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2763885
11 July 2006 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2709299
28 June 2006 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2748789
12 June 2006 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2677308
22 May 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2656189
12 May 2006 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2647311
25 April 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2634206
12 April 2006 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2624551
2 March 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2596916
9 February 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2582921
19 January 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2582925
13 January 2006 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2566547
1 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2526480
15 October 2005 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2547030
26 September 2005 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2526412
23 September 2005 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2535037
12 July 2005 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2432282
13 April 2005 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2332336
18 February 2005 Administrative Inspection · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2295336
26 January 2005 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2281239
19 January 2005 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2283567
5 January 2005 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2268691
4 October 2004 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2212771
23 September 2004 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2198339
14 September 2004 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2195732
4 August 2004 MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2155898
23 July 2004 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2142655
16 July 2004 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2135173
7 July 2004 Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2123584
30 June 2004 Security Plan Review - VSP
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2126431
31 March 2004 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2026143
5 January 2004 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1973571
25 September 2003 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1905345
19 August 2003 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1880816
16 July 2003 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1846818
3 July 2003 Underwater Inspection in lieu of Drydock
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1833800
21 April 2003 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1830846
9 April 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1764418
2 February 2003 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1752015
13 January 2003 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1727138
25 September 2002 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1673488
8 August 2002 Deadweight Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1656755
8 July 2002 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1640690
8 April 2002 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1600171
17 January 2002 Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1479493
2 January 2002 Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1474719
26 November 2001 Drydock Extension
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1373680
26 September 2001 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1468673
9 July 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1473551
9 April 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1439220
8 March 2001 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1058198
31 January 2001 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1057606
27 September 2000 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1467239
28 June 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1050642
29 March 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1466115
24 January 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1378920
20 October 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1445536
29 September 1999 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1411977
27 September 1999 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1460343
26 July 1999 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1101556
25 May 1999 Hull Examination · Drydock Extension
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1402911
14 May 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1458641
21 April 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1434848
24 February 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1471373
25 January 1999 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1418462
28 September 1998 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1460243
13 July 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1421535
13 April 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1456601
19 March 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 40788
6 March 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1419895
4 March 1998 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1121440
5 January 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1431902
29 September 1997 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1431879
30 June 1997 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1421384
28 March 1997 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1383533
6 January 1997 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1416419
30 September 1996 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1452213
8 July 1996 Deficiency Check · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1404241
26 April 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 8837
17 April 1996 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1451076
21 March 1996 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1078186
5 March 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 514647
29 February 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 67988
3 January 1996 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1430142
11 December 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 881463
11 October 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1190133
4 October 1995 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1357370
12 September 1995 Re-Inspection · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1371251
6 June 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1192869
10 May 1995 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1358834
21 April 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 861520
10 April 1995 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1405681
5 April 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1153029
31 March 1995 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 861733
22 March 1995 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 21100
27 February 1995 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 853677
9 February 1995 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1363247
7 December 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 481258
6 October 1994 Initial Certification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1436940
16 July 1994 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1439589

Deficiency record · 165

Engineering › Generator (propulsion-electric) › Semiconductor Rectifier Circuitry
Issued 13 January 2009 Resolved
Prove proper operation of #2 SCR motor ready circuit iaw 46 CFR 62.25.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 2 April 2009
Resolution: #2 SCR circuit tested sat.
Engineering › Electric Propulsion System › Indicator Circuitry
Issued 13 January 2009 Resolved
Make repairs to #4 MDG, prove proper operation of all safety devices iaw 46 CFR 62.25.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2009
Resolved 6 October 2009
Accommodation/Occupational Safety › Ventilation › General
Issued 13 January 2009 Resolved
Provide adequate protection to garbage room ventilation linkage iaw 46 cfr 72.15-15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2009
Resolved 2 April 2009
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 January 2009 Resolved
Provide additional electrical outlets in soft count, EDR iwo toaster, behind tv in employee lounge-or remove extension cords/equipment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 2 April 2009
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 January 2009 Resolved
Attach junction box behind count machine, soft count.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 2 April 2009
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 January 2009 Resolved
Secure cover on junction box in overhead, count pit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 2 April 2009
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 13 January 2009 Resolved
Remove/replace broken grounds/plugs on vaccums/floor machines (5).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 2 April 2009
Deck/Cargo › Cargo Stowage › General
Issued 13 January 2009 Resolved
Remove slot machines from main deck passageways.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 23 July 2009
Resolution: Machines removed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 January 2009 Resolved
Update panel menus on SP205, SP206
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 2 April 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 13 January 2009 Resolved
Adjust FSD #5E to close fully.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 2 April 2009
Personnel › Training › First Aid/CPR
Issued 13 January 2009 Resolved
Ensure 50% of marine crew is currently first aid/cpr trained.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 2 April 2009
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 13 January 2009 Resolved
Clean beneath equipment in EDR Galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 2 April 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 September 2008 Resolved
Provide proof by guaging that all exterior stair treads are structurally shown with no more than 25% wastage and renew all crumbled concrete per 46 CFR 71.25-50
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 April 2009
Resolved 2 April 2009
Construction/Loadline › Structures › Ventilators
Issued 15 September 2008 Resolved
Request approval for temp A/C units on main deck or remove IAW current stability letter.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 October 2008
Resolved 2 April 2009
Deck/Cargo › Cargo Stowage › General
Issued 15 September 2008 Resolved
Provide proof of all weight changes aboard vessel since December 13, 2006 or conduct a dead weight survey.
Action required: 705 - Other - as specified
Due 1 February 2009
Resolved 2 April 2009
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 24 July 2008 Resolved
Make permanent proper repairs to the sewage pump piping in void #4, pump #3. Currently the piping has a soft patch on it.
Action required: 705 - Other - as specified
Due 24 August 2008
Resolved 2 December 2008
Fire Fighting › Structural - A Class Divisions › Doors
Issued 24 July 2008 Resolved
Properly adjust all FSD's to 1/8 gap and ensure all closures and latches operate properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2009
Resolved 10 August 2009
Resolution: FSD''s tested sat.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 30 June 2008 Resolved
Provide means to conspicously mark Passenger Safety personnel per COI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 August 2008
Resolved 24 July 2008
Fire Fighting › Structural - A Class Divisions › Doors
Issued 30 June 2008 Resolved
Provide proof of operation of FSD's 1,10,13,18, gaps at 14A, Latch and threshhold at door No. 6, threshold was rusted through, and FSD 19 which had a broken closure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 24 July 2008
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 30 June 2008 Resolved
Renew ROX blocks in the bulkhead, Starboard HVAC space and the overhead in the CO2 Space. Penitrations missing packing.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 2 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 June 2008 Resolved
Remove all wire nuts in the High Limit area, or install in suitable junction boxes per 46 CFR 116.60-17
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 24 July 2008
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 30 June 2008 Resolved
Provide key for Marine Crew access to panelboard SVP 203.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 2 December 2008
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 30 June 2008 Resolved
Prior to storing food items in the Pantry Refer, provide proof that it can maintain items between 34-40 deg f.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 24 July 2008
Fire Fighting › Combustible Materials › Facings/Mouldings/Decorations/Veneers
Issued 30 June 2008 Resolved
Remove all combustable items stored in the port HVAC space or conduct fire load calculations and submit for review.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 24 July 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 June 2008 Resolved
remove or obtain approval for the Fixed fire extinguishing system in the surveillance space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 24 July 2008
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 17 March 2008 Resolved
Adjust FSD pair #14 to meet 46 CFR 72.05-25(b)(7). Gap was large enough to see outdoor- approximately 1/4-3/8" between doors.
Due 17 April 2008
Resolved 24 July 2008
Fire Fighting › Ventilation Systems › Operating Controls
Issued 17 March 2008 Resolved
Demonstrate proper operation of fire damper AHU #3.
Due 17 April 2008
Resolved 22 April 2008
Engineering › Thrusters › Motor
Issued 17 March 2008 Resolved
Develop a plan to properly make repairs to SCR thruster #5, during vsl propulsion operational tests thruster #5 spins the entire time, iaw 46 CFR 58.05.
Due 17 April 2008
Resolved 15 April 2008
Fire Fighting › Ventilation Systems › Operating Controls
Issued 16 January 2008 Resolved
Prove proper operation of the Following Fire Dampers: IGB room, Smokers Lounge, Womens Employee hallway, Casino Managers hallway.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 February 2008
Resolved 17 March 2008
Resolution: Womens employee hallway damper connects open corridor to space with open ventillation via hallway with no doors.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 16 January 2008 Resolved
Determine cause and correct fault and trouble indication on the ships fire alarm panel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 January 2008
Resolved 17 March 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 16 January 2008 Resolved
Prove proper operation of FSD No. 14. Door release bar on left side was stuck, and double doors binding at the top.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2008
Resolved 17 March 2008
Communications › Internal Communications System › Sound-powered Telephone
Issued 16 January 2008 Resolved
Prove proper operation of the service elevator phone.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 February 2008
Resolved 16 January 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 16 January 2008 Resolved
Rivise, and submit to the Marine Safety Center for approval an updated Fire Control Plan for the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 February 2008
Resolved 16 January 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 September 2007 Resolved
Install quick releases on all waterlights/ringbuoys.
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 3 October 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 17 September 2007 Resolved
Remove ATM and slot machines on main deck, port side, forward employee area.
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 3 October 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 September 2007 Resolved
Provide additional emergency lighting iwo fwd slot carousel, casino deck, outboard sides.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 3 October 2007
Resolution: Could not verify adequacy as vsl was open for gaming.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 17 September 2007 Resolved
Relplace starboard door to forward/center thruster enclosure.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 3 October 2007
Resolution: Door procured and in construction phase- vsl awaiting delivery.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 September 2007 Resolved
Add receptacles/reduce electrical loads in Cage/Credit Director office and Asst Slot Director office.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 3 October 2007
Personnel › Training › Safety Orientation
Issued 17 September 2007 Resolved
Provide "Right to Know" center with MSDS for items in Slot Repair flam locker.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 3 October 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 September 2007 Resolved
Ensure proper labeling of distribution panels #SP 201, SP 210, SP 212.
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 3 October 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 September 2007 Resolved
Renew first aid station in Slot Repair shop.
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 3 October 2007
Engineering › Diesel Engine (propulsion-electric) › Cylinder Head
Issued 17 September 2007 Resolved
Properly make repairs to SSDG #2, discovered jacket water pump was removed and parts are on order.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 3 October 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 September 2007 Resolved
Provide servicing of CO2 system in E-Generator space to be witnessed by marine inspector.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 3 October 2007
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 17 September 2007 Resolved
Remove all plastic trash containers from vessel.
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 17 March 2008
Electrical › Electric Generation Source (service) › Switch
Issued 20 September 2006 Resolved
Replace/Renew Thermostat switch covers in BMS and Soft count room per 46 CFR 72.20-15.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 November 2006
Resolved 21 December 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 September 2006 Resolved
Prove proper operation of Emergency lighting (Battery operated) in the Egen space, and SCBA Locker per 46 CFR 111.75-15.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 1 November 2006
Resolution: Emergency lighting in E-Gen and SCBA space were installed and working properly.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 September 2006 Resolved
Update Fire Control plan per 46 CFR 78.45-1.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 1 November 2006
Resolution: Proper fire control plan was posted at entrance to vessel.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 September 2006 Resolved
Properly mark emergency lighting in Third cage per 46 CFR 78.47-33.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 1 November 2006
Resolution: Proper markings on emergency lights were installed.
Fire Fighting › Combustible Materials › Matresses
Issued 28 June 2006 Resolved
Properly remove all combustibles and flammables aerosol cans from vessel or provide approved flame locker in accordance with 46 CFR 72.03-5.
Action required: 705 - Other - as specified
Due 28 July 2006
Resolved 20 September 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 June 2006 Resolved
Properly replace nonmetallic expansion joints on the raw water piping for generators, joint show deterioration in accordance with 46 CFR 61.15-12.
Action required: 705 - Other - as specified
Due 28 July 2006
Resolved 20 September 2006
Engineering › Diesel Engine (propulsion-electric) › Crankcase
Issued 28 June 2006 Resolved
Properly replace emission return hose on #4 generator in accordance with 46 CFR 58.10-10.
Action required: 705 - Other - as specified
Due 28 July 2006
Resolved 20 September 2006
Electrical › Electrical Distribution System (emergency) › Ground Detection
Issued 28 June 2006 Resolved
Properly locate and fix ground that is indicating on emergency switchboard in accordance with 46 CFR 111.05-21.
Action required: 705 - Other - as specified
Due 28 July 2006
Resolved 20 September 2006
Operations/Management › Passenger Operations › Safety Orientation
Issued 25 April 2006 Resolved
Resubmit emergency evacuation plan (Dockside) with revisions to reflect current configuration to the Coast Guard Marine Safety Center.
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 28 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2006 Resolved
Remove all jury rigged wiring from Top Hat area including dead end wires, temp drop lighting, and properly support wires 24" on center.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 28 June 2006
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 12 April 2006 Resolved
Repair loose A-60 insulation below the wheelhouse.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 28 June 2006
Resolution: Insulation had been installed in locations that were missing.
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 12 April 2006 Resolved
Repair lock for power panel EP-202 and remove paint fire pulls and dectector in the aft pilothouse.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 28 June 2006
Fire Fighting › Fire Hydrants › Condition
Issued 12 April 2006 Resolved
Repair fire station doors for Fire stations F.S. 2 and 3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 25 April 2006
Resolution: Sighted this date. [name withheld] carie
Communications › Radio Communications › Cellular Telephone Capability
Issued 12 April 2006 Resolved
Prove proper operation of the Elevator phones and alarms in all elevators.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 28 June 2006
Fire Fighting › Means of Escape › Blocked
Issued 12 April 2006 Resolved
Vessel has relocated various casino games and is no longer in compliance with the approved emergency evacuation plan.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 25 April 2006
Resolution: Sighted this date. [name withheld]
Engineering › Diesel Engine (propulsion-electric) › Air Cleaner
Issued 12 April 2006 Resolved
Prove proper operation of the SCR #4 Tach at the local station.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 28 June 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 12 April 2006 Resolved
Properly terminate dead end wire in slot panel number SP211 in front of WTD #7.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 25 April 2006
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 12 April 2006 Resolved
Remove all Air filters and boxes from obstructing access to the Bilge and Fire pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 25 April 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 13 January 2006 Resolved
Repair #7 Harmonic Circuit Breaker.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 9 February 2006
Resolution: Sighted this date. CWO3 jeff carie
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 January 2006 Resolved
Repait or replace the #1 Z-Drive Volt Meter.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 10 February 2006
Resolution: Sighted this date. CWO3 jeff carie
Electrical › Electric Generation Source (emergency) › Generator
Issued 13 January 2006 Resolved
Vsl to remain on shore power w/ main generators as redundancy until e-gen starting batteries are replaced.
Action required: 705 - Other - as specified
Resolved 13 January 2006
Resolution: Batteries replaced and e-gen tested. See docs for Chief Engineer statement.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 January 2006 Resolved
Check and replace all worn man lines on lifebuoys.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 9 February 2006
Resolution: Sighted this date. [name withheld] carie
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 13 January 2006 Resolved
Place ice scoop holders on or near all consumable ice containers and devise a means to ensure no other objects intrude into the ice bin.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 9 February 2006
Resolution: Sighted this date. [name withheld]
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 19 January 2005 Resolved
Vessel not in compliance with minimum manning as stated on COI a Mate is needed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2005
Resolution: Additional Mate on watch.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 5 January 2005 Resolved
Properly mark engine room CO2 system IAW 46CFR76.15-10 (h), to include a schematic drawing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2005
Resolved 26 January 2005
Resolution: CO2 schematic was posted.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 5 January 2005 Resolved
Remove all plastic waste receptacles and provide type in compliance with 46CFR72.05-55(4)(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2005
Resolved 18 February 2005
Resolution: Sighted this date, replaced with steel receptacles. [name withheld]
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 5 January 2005 Resolved
Provide means of determining temps in all food coolers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2005
Resolved 18 February 2005
Resolution: Sighted this date. [name withheld]
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 5 January 2005 Resolved
Remove all combustable material from HVAC spaces. 46CFR72.03-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2005
Resolved 26 January 2005
Resolution: HVAC area has been cleaned of unnessary boxes and organized with remaining stores.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 5 January 2005 Resolved
Based on safety issues uncovered during fire drill, vessel must immediately man vessel in accordance with the underway provisions of COI to include a LIC Mate.
Action required: 705 - Other - as specified
Due 20 January 2005
Resolved 26 January 2005
Resolution: Vessel is being manned in accordance with the COI.
Electrical › Electric Generation Source (emergency) › Generator
Issued 23 September 2004 Resolved
Prove proper operation of emergency generator alarms & lights for overspeed trip indication.
Due 23 October 2004
Resolved 4 October 2004
Resolution: Cleared based on affadavit. See documents file.
Fire Fighting › Means of Escape › Number
Issued 23 September 2004 Resolved
Submit plan to install secondary means of escape from all spaces (>300 sq. foot) where crew is normally employed IAW 46 CFR 72.10-5
Due 29 October 2004
Resolved 26 January 2005
Resolution: Requirement issued in error of the regulations.
Electrical › Electric Supply System (service) › Cable
Issued 31 March 2004 Resolved
Label all unlabeled switches
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 23 September 2004
Resolution: Sighted this date.
Fire Fighting › Means of Escape
Issued 5 January 2004 Resolved
Fire Screen Doors 20 and 21 did not open and close properly. LEGACY COMPONENT DESC: Doorways
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2004
Resolved 6 January 2004
Resolution: Doors properly open and close.
Electrical › Lighting (emergency)
Issued 25 September 2003 Resolved
Ensure all emergency lights have an "E" placard on or around fixture.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Resolution: Replaced
Electrical › Lighting (emergency)
Issued 25 September 2003 Resolved
Replace all "E" placards that have been painted over.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Resolution: Replaced
Engineering › Diesel Engine (auxiliary)
Issued 25 September 2003 Resolved
Double clamp water hoses on emergency generator.
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 6 January 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 25 September 2003 Resolved
Place MSDS in both Soft Count rooms, Hard Count, and Mens and Womens Janitor Closets on the Main Deck.
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Resolution: MSDS books audited and placed where chemicals are stored.
Electrical › Electrical Distribution System (service)
Issued 25 September 2003 Resolved
Ensure all thermostat controls are covered.
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Resolution: All covered
Electrical › Electrical Distribution System (service)
Issued 25 September 2003 Resolved
Place all wires in overhead into wire cradles. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Electrical › Electrical Distribution System (service)
Issued 25 September 2003 Resolved
Knife switches in elevator hydraulic rooms need labels. LEGACY COMPONENT DESC: Switch
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Electrical › Electrical Distribution System (emergency)
Issued 25 September 2003 Resolved
Repair battery "E" lights in emergency generator room and EOS.
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Electrical › Electrical Distribution System (service)
Issued 25 September 2003 Resolved
Fix GFI outlets in Mens Head on the Main Deck. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Fire Fighting › Ventilation Systems
Issued 25 September 2003 Resolved
Ensure all remote levers for vent closures are operational and functional. LEGACY COMPONENT DESC: Ducts
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Construction/Loadline › Penetrations
Issued 25 September 2003 Resolved
Repair the through hull opening in overhead in Main Deck Main Janitors Closet where Rox Blocks have fallen LEGACY COMPONENT DESC: Gasket
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Resolution: Replaced Blocks
Fire Fighting › Miscellaneous Items
Issued 25 September 2003 Resolved
Install insulation in Main Deck Trash Closet and Service Elevator Hydrolic Room. LEGACY COMPONENT DESC: Insulation (Penetration of Oil/Oil Vapors)
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Fire Fighting › Miscellaneous Items
Issued 25 September 2003 Resolved
Ensure General Alarm Bells port fwd of amidships and port stern are operational.
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 10 October 2003
Resolution: New bells were installed and tested.
Fire Fighting › Structural - A Class Divisions
Issued 16 July 2003 Resolved
Repair fire screen doors 5 and 14 to properly close and latch. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 16 August 2003
Resolved 14 August 2003
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 16 July 2003 Resolved
Determine and correct high temps in refers in all areas.
Condition: Improper/Lack of Maintenance
Due 16 August 2003
Resolved 14 August 2003
Resolution: All refrigerators had the coils cleaned, gaskets check and/or replaced. Units are within green range.
Engineering
Issued 25 September 2002 Resolved
Provide copy of periodic automation test procedures for approval
Due 25 November 2002
Resolved 3 October 2002
Resolution: Copy for approval was located at MSO Chicago. Loss attributable to some difficulties in passing along of project material during personnel relief here.
Engineering › Thrusters
Issued 25 September 2002 Resolved
Prove proper operation of #1, 2, 3 thruster tachometers at bridge and engine room control panels.
Due 31 March 2003
Resolved 28 August 2003
Resolution: Cleared upon receipt of affadavit from [name withheld].
Engineering › Thrusters
Issued 25 September 2002 Resolved
Prove proper operatation of #2 & 4 motor ready lights at thruster control panel in e/r LEGACY COMPONENT DESC: Motor
Due 25 October 2002
Resolved 13 January 2003
Engineering
Issued 25 September 2002 Resolved
Prove proper operation of E/R vent damper #1 and all penthouse air handler fire dampers
Due 25 October 2002
Resolved 14 January 2003
Electrical › Electrical Distribution System (service)
Issued 25 September 2002 Resolved
Correct "Rox Blocks" in bulkhead penetration to AMR from E/R LEGACY COMPONENT DESC: Wiring
Due 25 October 2002
Resolved 25 September 2002
Documentation › Markings/Placards
Issued 25 September 2002 Resolved
Renew pollution placard (illegible) LEGACY COMPONENT DESC: Oil Discharge Placard
Due 14 January 2003
Resolved 14 January 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 25 September 2002 Resolved
Prove proper operation of CO2 siren in E/R (was inaudible if >15' from siren when engines running)
Due 25 October 2002
Resolved 14 January 2003
Accommodation/Occupational Safety
Issued 25 September 2002 Resolved
Properly light and mark E/R escape route. (Two void areas following AMR in route are currently unlit. Insufficient arrows to adequately direct personel from engine room, through voids, and to safe refuge.)
Due 25 October 2002
Resolved 14 January 2003
Electrical › Electric Generation Source (service)
Issued 25 September 2002 Resolved
Provide proof of proper reverse power relay time delay limitations. Adjust settings on all SSDG reverse power relays to these limits.
Due 25 October 2002
Resolved 14 January 2003
Fire Fighting › Miscellaneous Items
Issued 8 July 2002 Resolved
Make repairs to fire pump pressure gauge in pilot house. LEGACY COMPONENT DESC: Gauges
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 21 August 2002
Electrical › Electric Generation Source (emergency)
Issued 8 July 2002 Resolved
Trace and repair electrical ground as indicated on emergency generator switchboard. LEGACY COMPONENT DESC: Ground Detection
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 21 August 2002
Electrical
Issued 27 September 2000 Resolved
Prove proper operation of (battery powered) emergency lights in emergency generator room, engine room control booth, and auxiliary machinery room.
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Construction/Loadline
Issued 27 September 2000 Resolved
Prove proper operation of Fire Screen Door #13 and snack bar door leading to break room, to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Electrical
Issued 27 September 2000 Resolved
Replace missing flourescent light covers in hard count and surveillance rooms, to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Electrical
Issued 27 September 2000 Resolved
Ensure all power strips are properly mounted and all wiring neatly routed, to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Electrical
Issued 27 September 2000 Resolved
Replace missing thermostat covers in soft count pit and slots rooms, to thesatisfaction of the attending marine inspector.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Unknown
Issued 27 September 2000 Resolved
Prove proper operation of vent louver in emergency generator room (louver NOT attached to engine).
Condition: Unknown
Due 27 October 2000
Resolved 18 October 2000
Engineering
Issued 27 September 2000 Resolved
Prove proper operation of emergency generator high jacket water temperaturealarm.
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Accommodation/Occupational Safety
Issued 27 September 2000 Resolved
Remove all plastic trash cans from vessel, to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Lifesaving
Issued 27 September 2000 Resolved
Properly label oars in both rescue boats, to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Electrical
Issued 27 September 2000 Resolved
Properly label emergency lighting in surveillance room, to the satisfactionof the attending marine inspector.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Accommodation/Occupational Safety
Issued 27 September 2000 Resolved
Ensure all sewage, fuel oil and potable water hoses are properly capped andplugged, to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Construction/Loadline
Issued 27 September 2000 Resolved
Replace missing dog on forward port hatch cover on bridge deck, to the sat-isfaction of the attending marine inspector.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Engineering
Issued 27 September 2000 Resolved
Prove proper operation of #2 SS Generator overspeed trip (trip value less than 2070 RPM).
Condition: Unknown
Due 27 October 2000
Resolved 18 October 2000
Engineering
Issued 27 September 2000 Resolved
Prove proper operation of #1 SS Generator high jacket water temperature alarm sending unit (alarm works, sending unit does not)
Condition: Unknown
Due 27 October 2000
Resolved 18 October 2000
Construction/Loadline
Issued 27 September 2000 Resolved
Prove proper operation of #7 void bilge high level alarm.
Condition: Unknown
Due 27 October 2000
Resolved 18 October 2000
Lifesaving
Issued 24 January 2000 Resolved
Provide documentation that all crewmembers have participated in all required drills.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Lifesaving
Issued 24 January 2000 Resolved
Update muster list and emergency instructions i.a.w. 199.80 and provide list for approval i.a.w. 199.217
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Fire Fighting
Issued 24 January 2000 Resolved
Install a pressure relief valve in the sprinkler pressure tank that complies with 46 CFR 54.15-10
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Accommodation/Occupational Safety
Issued 24 January 2000 Resolved
Properly mark escape route from the Aux machinery room and remove old markings.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Fire Fighting
Issued 21 April 1999 Resolved
Provide plans for installation of pressure relief valves for fire pumps IAWwith 46CFR76.10-5(d).
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Fire Fighting
Issued 25 January 1999 Resolved
INSTALL SMOKE DETECTION UNITS IN MAIN DECK, CREDIT OFFICE, MAINTENANCE SPACE, NURSE'S OFFICE, AND THE TRASH ROOM
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Lifesaving
Issued 25 January 1999 Resolved
PROVIDE PLAN FOR REPLACEMENT EMERGENCY ESCAPE ROUTE FROM AUX MACHINERY ROOMAS DISCUSSED
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Construction/Loadline
Issued 25 January 1999 Resolved
PROPERLY MARK ENGINE ROOM EMERGENCY ESCAPE DOORS, INSIDE & OUT
Condition: Unknown
Due 25 February 1999
Resolved 13 April 1999
Electrical
Issued 13 April 1998 Resolved
REMOVE OR PROPERLY SECURE ALL DEAD ENDED WIRES IN WAY OF ALL LIQUOR PUMPS AT PASSENGER SERVICE BARS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1998
Resolved 22 May 1998
Lifesaving
Issued 5 January 1998 Resolved
Repair rotating red flashing light in engine room and prove proper operation of same.
Condition: Unknown
Due 12 January 1998
Resolved 7 January 1998
Accommodation/Occupational Safety
Issued 5 January 1998 Resolved
Remove items improperly stored behind starboard SCR panel.
Condition: Unknown
Due 12 January 1998
Resolved 7 January 1998
Electrical
Issued 5 January 1998 Resolved
Properly secure all installed wiring and cabling to meet the requirements of Institute of Electrical and Electronics Engineers, Standard 45 (IEEE Std45), Section 20.5, to the satisfaction of the [name withheld].
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Lifesaving
Issued 28 March 1997 Resolved
Repair loose cover on embarkation light at liferaft in way of starboard bow.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Lifesaving
Issued 28 March 1997 Resolved
Install retroreflective tape on all liferings.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Electrical
Issued 28 March 1997 Resolved
Remove extension cord from behind water fountain in casino deck service barand replace with receptacle or other permanent power connection.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Accommodation/Occupational Safety
Issued 17 April 1996 Resolved
Clean and maintain proper cleanliness standards on the following areas: forward, main deck service bar and 2nd deck, stage bar below counters.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Accommodation/Occupational Safety
Issued 11 October 1995 Resolved
Demonstrate, by satisfactory results of air quality testing by an independent test lab, that the air in inhabited spaces is reasonably free of biological contaminants.
Condition: Unknown
Due 11 December 1995
Resolved 11 December 1995
Accommodation/Occupational Safety
Issued 11 October 1995 Resolved
Clean parts and areas of air handling equipment which are subject to contact with moisture.
Condition: Unknown
Due 11 December 1995
Resolved 11 December 1995
Electrical
Issued 4 October 1995 Resolved
Install additional emergency lighting in casino deck stage and adjacent liquor locker.
Condition: Unknown
Due 10 November 1995
Resolved 10 November 1995
Accommodation/Occupational Safety
Issued 4 October 1995 Resolved
Repair latch to emergency generator door.
Condition: Unknown
Due 10 November 1995
Resolved 10 November 1995
Electrical
Issued 4 October 1995 Resolved
Provide emergency lighting in vicinity of #3 fire pump space ladder.
Condition: Unknown
Due 10 November 1995
Resolved 10 November 1995
Fire Fighting
Issued 4 October 1995 Resolved
Repair latching mechanisms of indicated Fire Screen Doors, including but not limited to, #4, 8, 10, 14A & 20.
Condition: Unknown
Due 10 November 1995
Resolved 10 November 1995
Fire Fighting
Issued 4 October 1995 Resolved
Provide 100 percent servicing and testing of pull stations, smoke, thermal and trouble alarms and provide documentation fo such.
Condition: Unknown
Due 10 November 1995
Resolved 10 November 1995
Fire Fighting
Issued 4 October 1995 Resolved
Clean all smoke detectors on main casino floor and other smoking spaces which were fouled by cigarette smoke. Cleaning and maintenance is to provide sufficient smoke detection sensitivity.
Condition: Unknown
Due 10 November 1995
Resolved 10 November 1995
Documentation
Issued 4 October 1995 Resolved
Provide proof of current Certificate of Documentation.
Condition: Unknown
Due 10 November 1995
Resolved 10 November 1995
Electrical
Issued 4 October 1995 Resolved
Remove all dead-end wires in forward elevator machinery space.
Condition: Unknown
Due 10 November 1995
Resolved 10 November 1995
Accommodation/Occupational Safety
Issued 4 October 1995 Resolved
Provide proof of safe evacuation of main deck forward office space passageway; passageway has five various computer printers and copiers.
Condition: Unknown
Due 10 November 1995
Resolved 10 November 1995
Accommodation/Occupational Safety
Issued 12 September 1995 Resolved
Renew all non-fire retardant carpet pad not later than the compliance date.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Fire Fighting
Issued 12 September 1995 Resolved
Replace 1 1/2 inch fire hose as indicated by CG Marine Inspector which failed with several pin-size holes.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Electrical
Issued 10 May 1995 Resolved
Provide plans for lighting modifications on main deck casino._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Fire Fighting
Issued 10 May 1995 Resolved
Repair and prove operation of fire screen door #10._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Electrical
Issued 10 May 1995 Resolved
Properly wire coffee pot elecric outlet in employee/crews' lounge._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Electrical
Issued 10 May 1995 Resolved
Properly seal stuffing tube in overhead of forward liquor locker.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Electrical
Issued 10 May 1995 Resolved
Remove eletrical extension cord through stuffing box on deck of forward liquor locker._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Electrical
Issued 10 May 1995 Resolved
Properly strap new wire in forward liquor locker and two new wires on forward exterior area of Casino deck._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Electrical
Issued 5 April 1995 Resolved
Provide plans, approved by the Marine Safety Center, for the integrated propulsion/steering, and monitoring and alarm systems, and qualitative failure and design verification test proceedures in accordance with MSC letter 16710 dated 23FEB95._x001C_
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 31 March 1995 Resolved
RENEW ALL NON FIRE RETARDANT CARPET PAD NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Accommodation/Occupational Safety
Issued 31 March 1995 Resolved
RENEW CARPET PAD IN THE LOCATIONS DESCRIBED IN [name withheld] 31, 1995 TO GUIDO PERLA & ASSOCIATES NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Fire Fighting
Issued 27 February 1995 Resolved
SUBMIT CORRECTED FIRE AND SAFETY PLAN TO ACCURATELY DESCRIBE ADDITIONAL INSTALLATION OF FIREFIGHTING EQUIPMENT.
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Electrical
Issued 27 February 1995 Resolved
SUBMIT TO USCG MARINE SAFETY CENTER SATISFACTORY DETAILS FOR THE INTEGRATEDPROPULSION/STEERING, AND MONITORING & ALARM SYSTEMS, QUALITATIVE FAILURE ANALYSIS AND DESIGN VERIFICATION TEST PROCEDURES IN ACCORDANCE WITH MARINE SAFETY CENTER LETTER 16710 DATED 23 FEBRUARY 1995.
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Accommodation/Occupational Safety
Issued 6 October 1994 Resolved
Provide a carpet padding installation which will meet the requirement in 46CFR 72.05-55(a)(4).
Condition: Unknown
Due 6 October 1994
Resolved 6 October 1994
Lifesaving
Issued 6 October 1994 Resolved
Provide proper stowage for personal floatation devices.
Condition: Unknown
Due 2 March 1995
Resolved 2 March 1995
Electrical
Issued 6 October 1994 Resolved
Complete installation of lower weather deck lighting.
Condition: Unknown
Due 2 March 1995
Resolved 2 March 1995
Electrical
Issued 6 October 1994 Resolved
Complete installation of metallic banding on cable raceways as indicated byattending inspector.
Condition: Unknown
Due 2 March 1995
Resolved 2 March 1995
Fire Fighting
Issued 6 October 1994 Resolved
Provide a third fire pump for fire main system as requireed in 46 CFR 76.10-5(a) for vessels over 4000 gross tons on other than international voyages.
Condition: Unknown
Due 6 October 1994
Resolved 6 October 1994
Construction/Loadline
Issued 6 October 1994 Resolved
Provide an indicating panel in the pilot house to show status of all (eight) watertight doors.
Condition: Unknown
Due 2 March 1995
Resolved 2 March 1995
Lifesaving
Issued 6 October 1994 Resolved
Properly and permanently mount ring buoy brackets._x001C_
Condition: Unknown
Due 2 March 1995
Resolved 2 March 1995

Casualty record · 10

23 September 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2535037
15 October 2005Routine · role: Involved in a Marine Casualty · 1 injured · activity 2547030
19 January 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2582925
2 March 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2596916
17 October 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2831482
21 October 2006Routine · role: Involved in a Marine Casualty · activity 2830168
14 November 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2852398
18 January 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 2880663
1 February 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2869131
17 September 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 3072702
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.