DISCOVERY is a 1992 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1994, most recently in March 2026, along with 186 deficiencies and 4 operational controls.

Records from 1994 to 2026. Most recent: inspection, 2 March 2026.

Built
1992
Last inspected
2 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF2183
414520
Flag
UNITED STATES
—
Maury page id
psix-414520

Inspections, by type

…with no type recorded6
Years with a record 24 calendar years (1994–2026)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 50

2 March 2026 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8318295
15 January 2026 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8294529
21 November 2024 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8038407
15 October 2024 Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8018852
15 January 2024 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7849549
2 October 2022 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7570173
21 October 2021 COI Inspection · Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7337489
1 September 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6999125
1 September 2020 Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7058258
20 November 2019 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6859665
25 October 2019 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6841737
27 March 2019 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6676487
25 September 2018 Drydock Exam · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6562831
29 January 2018 Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6346714
9 September 2016 Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5995044
31 August 2016 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5989134
14 July 2016 COI Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5940035
11 October 2015 Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5746468
15 August 2015 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5216378
12 June 2012 Internal Structural Exam · Examination of Repairs · Hull Examination · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4341422
11 July 2011 Deficiency Check · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4071046
15 October 2010 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3870176
11 August 2008 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3295108
22 May 2008 Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3213171
5 September 2007 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3049350
20 February 2007 Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 2877396
17 July 2006 COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2722502
3 July 2006 Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2699019
20 September 2005 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2496620
3 November 2004 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2233609
15 September 2004 Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2197765
14 July 2004 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2134768
3 July 2003 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1830547
5 September 2002 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1668079
1 July 2002 Re-Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1639103
5 September 2001 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1072088
28 June 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1362318
24 July 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361606
16 June 2000 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365844
12 July 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1095867
7 June 1999 MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1402888
29 March 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1115761
5 January 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 810726
8 December 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 809245
24 November 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 806057
17 August 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 801745
29 June 1998 MARPOL Annex V Examination · Hull Examination · Initial Certification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1368887
4 October 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 678646
15 September 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 23630
15 September 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 56494

Deficiency record · 186

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 January 2026 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Forward port and starboard side hull space do not have bilge high level alarms installed. Install alarm. 46 CFR 182.530(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2026
Resolution: New high water alarm installed. Video reviewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 January 2026 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that:(1) The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Forward port and starboard side hull space have non-UL listed bilge pumps. Install UL listed bilge pump. 46 CFR 182.520(e)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2026
Resolution: New UL pump installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 January 2026 Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Port side engine is leaking exhaust gases into the engine compartment. Determine where exhaust is stemming from and provide repair proposal. 46 CFR 182.430(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2026
Resolution: Exhaust leak was fixed. Video reviewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 22 November 2024 Resolved
FCC Radio Safety Certificate is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2024
Resolved 25 November 2024
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 November 2024 Resolved
Coast Guard Light List is out of date.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2024
Resolved 25 November 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 November 2024 Resolved
First aid kit's aspirin is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2024
Resolved 25 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 January 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. The port engine jacket water pipe broke and is leaking jacket water. 46 CFR 182.200
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 January 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 16 January 2024 Resolved
An existing vessel must comply with the watertight integrity regulations which were applicable to the vessel. The port and stbd engine room bulkhead have cables penetration that are not sealed. 46 CFR 179.115
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 January 2024
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 January 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date: Charts, U.S. Coast Pilot, CG light list and tide tables. The Coast Pilot and light list are not up to date.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 January 2024 Resolved
The vessel did not have 31 adult Type 1 life jackets as required by the COI. Only 29 adult life jackets were onboard. Reduced passenger count to 27.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 January 2023 Resolved
Ring buoy water light's line is not dark color synthetic and less than 3 feet long and missing a corrosion resistant clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 January 2023 Resolved
Lifejackets stowage markings are missing letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2023 Resolved
Port side emergency fuel shutoff handle is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 October 2021 Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose, which do not rely on the spring tension of the clamp for compression force and are installed beyond the bead or flare. Replace missing second hose clamp on electrical submersible pump in aft machinery compartments.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 October 2021 Resolved
A vessel must carry adequate and up-to- date U.S. Coast Pilot or similar publication, and adequate and up-to- date Coast Guard Light List. Update as required and maintain onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 October 2021 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel Prove operation of port jacket water discharge temperature.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2021 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions. Emergency instructions not posted. Provide instructions outlined in 46 CFR 185.512.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 October 2021 Resolved
Each vessel must be equiped with at least two operable battery lights. Replace missing flashlights and maintain on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2021 Resolved
IMO Res A.658(16) Annex 2 (3.1) The brightness of the retro-reflective material when tested should be not less than 80% of its original installation. Retroreflective material is worn. Replace with new as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 October 2021 Resolved
Waste receptacles must be constructed of non-combustible materials with no openings in the sides or bottom. Replace missing receptacle and maintain on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2021
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 21 October 2021 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Replace missing placard with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2021
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 21 October 2021 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. Replace missing thimble on eye connected to anchor chain to prevent chaffing of rope.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 October 2021 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Ring buoy and lifejackets to be wiped clean of mold and debris.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 October 2021 Resolved
Repair cracked weld on bottom of forward most vertical stanchion on port side engine room hatch cover to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 June 2021 Resolved
46 CFR 180.78 (a)(5): Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Mark designated locations where adult/children life jackets are stored.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 June 2021 Resolved
46 CFR 183.420: All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Prove proper operation of anchor and navigational lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 June 2021 Resolved
46 CFR 177.900: Deck rails must withstand a pointload of 200lbs applied in any direction. Repair portside forward rung on rail to as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 June 2021 Resolved
46 CFR 177.115: Repairs or maintenance conducted on an existing vessel, resulting in no significant changes to the original structure or arrangement of the vessel, must comply with the regulations applicable to the vessel on March 10, 1996, or, as an alternative, with the regulations in this part. However, when outfit items such as furnishings and mattresses are renewed, they must comply with the regulations in this part. Repair seating benches on main deck to as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 June 2021 Resolved
46 CFR 182.410: Gages to indicate lubricating oil pressure and cooling water discharge temperature shall be provided for all propulsion engine. Prove proper operation of port main engine oil pressure gage and water temperature gages for both main engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2021 Resolved
46 CFR 182.720(e)(3)(v)(B): Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose, which do not rely on the spring tension of the clamp for compression force and are installed beyond the bead or flare. Replace missing second hose clamp on electrical submersible pump in forward void.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 September 2020 Resolved
46 CFR 176.500: Pending completion of satisfactory annual inspection to the satisfaction of the attending Marine Inspector, vessel is prohibited from carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 October 2019 Resolved
46 CFR 185.604: Renew reflective tape on 07, life jackets for adults with USCG approved SOLAS A, tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 20 November 2019
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 25 October 2019 Resolved
46 CFR 180.70: Renew reflective tape on ring life buoy with USCG approved SOLAS A, tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 20 November 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 October 2019 Resolved
46 CFR 184.710: Mark first aid kit box with vessel’ name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 20 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 October 2019 Resolved
46 CFR 181.520: Portable fire extinguishers to be installed on main deck and all three portable fire extinguishers must have a visible placard/sign.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 20 November 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 October 2019 Resolved
46 CFR 185.604: Mark on stowage box number of life jackets for children.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 20 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 October 2019 Resolved
46 CFR 182.20-5(b): Repair and prove operation of port main engine temperature gage at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 20 November 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 October 2019 Resolved
46 CFR 185.516: Provide donning placard for different types of Type 1, lifejackets carried on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 20 November 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 28 March 2019 Resolved
Post placards for life jacket donning instructions, emergency instructions, and broadcast.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 March 2019 Resolved
Proof of inspection for pre-engineered firefighting systems.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2019 Resolved
Update company drug policy for part time employees.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 March 2019 Resolved
Replace non-watertight box for flares with a watertight box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2019 Resolved
Double clamp both ends of port and starboard aft overboard pumps in engine compartments.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2019 Resolved
Properly secure port and starboard side bilge pumps in forward compartment to deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 March 2019 Resolved
Replace battery for buoyant light with approved type per manufacturer specifications.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 March 2019 Resolved
Affix correct number for children lifejackets on stowage box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 March 2019 Resolved
Fix port side temperature gage for port main engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 28 March 2019 Resolved
Man Overboard Drills to be completed to the satisfaction of attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2019 Resolved
Replace bonding strap for port and starboard fuel tanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 March 2019 Resolved
Replace expired hand held flares with new. (Total 4).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 March 2019 Resolved
Replace adult life jackets with wasted/worn reflective tape with new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2019 Resolved
Properly secure loose clamp on starboard fill line on tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 March 2019 Resolved
Total number of fire extinguishers and type must be onboard the vessel as required per vessel's COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 February 2018 Resolved
COLREG: Replace burnt ou light bulb for all around light with new. Vessel is restricted to operating during daylight hours and good visibility pending corrective action.
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 13 February 2018
Construction/Loadline › Structures › Manhole
Issued 7 February 2018 Resolved
46 CFR 179.360: Replace missing latches (securing devices) for forward hull deck hatch covers.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 15 February 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 February 2018 Resolved
46 CFR 185.604(b): Mark life ring with vesel's name and port in clearly legible block capital letters.
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 15 February 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 February 2018 Resolved
46 CFR 160.041-4: First Aid Kit does missing multiple contents.
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 15 February 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 February 2018 Resolved
46 CFR 182.430(e): Double clamp exhaust hose on port side M/E.
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 13 February 2018
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 February 2018 Resolved
46 CFR 16: Failure to provide proof of enrollment in a random drug program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 January 2018 Resolved
46CFR176.500: Failure to conduct annual inspection for 2017.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2018
Resolution: 1st annual inspection completed on 06FEB2018. Opertional control lifted.
Engineering › Diesel Engine (propulsion-reduction gear) › Piston
Issued 31 August 2016 Resolved
Vessel owner has secured engine due to possible material failure of pistons.
Action required: 705 - Other - as specified
Resolved 28 April 2017
Resolution: Replaced main engine with inkind; got underway-all satisfactory.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 19 July 2016 Resolved
Port side wet exhaust found with crack located along underside of fiberglass before terminating at transom. Energized port main and witnessed minor leak of approximately one drop per minute. Exhaust to be replaced with new at dry dock in September 2016. 46 CFR 182.425/430.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 27 March 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 July 2016 Resolved
Reflective tape found deteriorated. 46 CFR 185.604.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2016
Resolution: Deteriorated reflective tape replaced with new.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 July 2016 Resolved
Vessel's COI expired on 11JUL16. No sail issued pending completion of COI scheduled for 19JUL2016.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2016
Resolution: COI completed this date.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 14 July 2016 Resolved
Adult and child life jackets combined in one storage. 46 CFR 180.71.
Due 19 August 2016
Resolved 19 July 2016
Resolution: Child life jackets segregated from adult life jackets.
Fire Fighting › Fire Bucket › Capacity
Issued 14 July 2016 Resolved
Replace 2.0 gallon fire buckets with 2.5 as per regulatory cite. 46 CFR 181.610.
Due 19 August 2016
Resolved 19 July 2016
Resolution: 2.0 gallon fire buckets replaced with 2.5 gallon; total of 3 fire buckets.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 14 July 2016 Resolved
Gauge covers deteriorated for port and starboard engines. To be replaced with new at dry dock scheduled on 09SEP2016. 46 CFR 182.410.
Due 9 September 2016
Resolved 27 March 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 July 2016 Resolved
Portable bilge pump not onboard at time of renewal. 46 CFR 182.510(a).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2016
Resolution: Portable bilge pump onboard at time of deficiency follow up.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 14 July 2016 Resolved
Cable for throttle linkage deteriorated. Replace with new at dry dock in September 2016. 46 CFR 182.200.
Due 9 September 2016
Resolved 27 March 2017
Engineering › Fuel Oil Service System › Filter
Issued 14 July 2016 Resolved
Replace missing starboard ME racor filter with new plug. 46 CFR 182.455.
Due 14 August 2016
Resolved 19 July 2016
Resolution: Replaced to the satisfaction of attending MI.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 July 2016 Resolved
Missing name of vessel on lifebuoy. 46 CFR 180.70.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2016
Resolution: Name marked on vessel to the satisfaction of attending MI.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 July 2016 Resolved
Replace expired battery with new. 46 CFR 180.70.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2016
Resolution: New battery installed to the satisfaction of attending MI.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 14 July 2016 Resolved
Replace missing gasket for port engine watertight hatch cover with new.
Due 19 August 2016
Resolved 19 July 2016
Resolution: Replaced with new gasket to the satisfaction of attending MI.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 July 2016 Resolved
Port side emergency fuel shut off not marked. 46 CFR 185.608.
Due 19 August 2016
Resolved 19 July 2016
Resolution: Marked to the satisfaction of attending MI.
Lifesaving › Hand Flares › Quantity
Issued 28 October 2015 Resolved
Provide 4 additional Distress Flares.
Action required: 705 - Other - as specified
Due 28 November 2015
Resolved 28 October 2015
Resolution: Purchased 4 additional flares.
Lifesaving › Hand Flares › Storage
Issued 28 October 2015 Resolved
Provide brightly colored portable watertight container with "Distress Signals" written on the outside.
Action required: 705 - Other - as specified
Due 28 November 2015
Resolved 28 October 2015
Resolution: Found proper container.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 October 2015 Resolved
Provide proper battery (with stud terminals) for Ring Life Buoy Waterlight.
Action required: 705 - Other - as specified
Due 28 November 2015
Resolved 28 October 2015
Resolution: Purchased correct battery and installed.
Engineering › Fuel Oil Service System › Valve
Issued 28 October 2015 Resolved
Properly mark remote fuel shutoff valves.
Action required: 705 - Other - as specified
Due 28 November 2015
Resolved 28 October 2015
Resolution: Corrected.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 October 2015 Resolved
Vessel is more than 90 days beyond COI date without completing an Annual Inspection. "No-Sail CG-835" issued.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2015
Resolution: Completed annual inspection.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 July 2012 Resolved
Provide tamper seals on FIREBOY manual release handles.
Due 23 July 2012
Resolved 20 July 2012
Resolution: Tamper seals installed.
Navigation › Piloting/Steering › Magnetic Compass
Issued 9 July 2012 Resolved
Provide light for compass.
Due 23 July 2012
Resolved 20 July 2012
Resolution: Light repaired.
Navigation › Piloting/Steering › Marine Charts
Issued 9 July 2012 Resolved
Provide chart for area of operation.
Due 23 July 2012
Resolved 20 July 2012
Resolution: Chart provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 9 July 2012 Resolved
Provide updated Light List and Coast Pilot.
Due 23 July 2012
Resolved 20 July 2012
Resolution: Light List and Coast Pilot updated.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 11 July 2011 Resolved
Remove wire ties from FFE manual release T-handles and install proper tamper seals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2011
Resolution: Proper tamper seals installed.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 11 July 2011 Resolved
Provide 4 hand held red flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2011
Resolution: 4 hand held red flares provided.
Fire Fighting › Fire Bucket › Availability
Issued 11 July 2011 Resolved
Provide 3 fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2011
Resolution: Fire buckets provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 July 2011 Resolved
Provide chart, coast pilot, light list, and tide information.
Due 18 July 2011
Resolved 12 July 2011
Resolution: Nautical publications provided.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 15 October 2010 Resolved
Machinery space ventilation stops lack 100 percent coverage.
Due 29 October 2010
Resolved 2 November 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 October 2010 Resolved
First Aid kit items expired. Replace as new.
Due 29 October 2010
Resolved 2 November 2010
Lifesaving › Lifebuoys › Serviceable
Issued 15 October 2010 Resolved
Replace ring buoy as new.
Due 29 October 2010
Resolved 2 November 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 October 2010 Resolved
Replace port and starboard navlights as new prior to operations in reduced visibility or at night.
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 2 November 2010
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 15 October 2010 Resolved
Port engine space Fireboy indicator light inop. Repair/replace.
Due 29 October 2010
Resolved 2 November 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 October 2010 Resolved
Aft/bow rails on port side have cracked welds. Reweld as necessary.
Due 29 October 2010
Resolved 2 November 2010
Stability › Watertight Integrity › General
Issued 15 October 2010 Resolved
Cap off starboard machinery space through-hull.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2010
Resolved 2 November 2010
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 15 October 2010 Resolved
Starboard engine RPM indicator inop.
Due 29 October 2010
Resolved 2 November 2010
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 August 2008 Resolved
Provide Coast Pilot on board vessel.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 27 August 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 August 2008 Resolved
Provide complete first aid kit. Several items expired and/or missing.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 27 August 2008
Resolution: Vessel rep purchased a new 1st aid kit o/b.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 11 August 2008 Resolved
Properly mount all three portable fire extinguishers.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 27 August 2008
Fire Fighting › Fire Bucket › Capacity
Issued 11 August 2008 Resolved
Provide three fire buckets. One missing.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 27 August 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 August 2008 Resolved
Provide metal ties to secure wiring to vessel every 24 inches.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 27 August 2008
Resolution: Vessels reps installed a metallic bracket every 24" with sat results.
Engineering › Bilge Water Management System › Pump
Issued 11 August 2008 Resolved
Properly mount/secure forward starboard side bilge pump.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 27 August 2008
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 22 May 2008 Resolved
Replace worn cutlass brg port shaft.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Resolution: Vessel reps replaced cutlas bearing, all sat.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 22 May 2008 Resolved
Repace short bolts on stdb shaft strut.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Resolution: Vessels reps replaced all the bolts on the stbd strut assmy, all sat.
Engineering › Fuel Oil Service System › Valve
Issued 22 May 2008 Resolved
Repair loose cable connector on emergency fuel shut off valve both port & stbd engines.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Resolution: Vessels reps repaired shut off, tested sat.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 22 May 2008 Resolved
Replace 1 hose clamp on stbd shaft packing gland.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Resolution: Vessels reps replaced the hose clamp, all sat.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 22 May 2008 Resolved
Replace turbo cooling line port engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Resolution: Vessels reps replaced the damaged hose, tested sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 May 2008 Resolved
Replace PVC 90 degree elbow on port engine salt water pump suction.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Resolution: Vessels reps removed plastic in the R/W circuit.
Construction/Loadline › Hull › Side Shell
Issued 22 May 2008 Resolved
Repair hull damage fwd port bow.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2008
Resolved 22 May 2008
Resolution: Vessels reps repaired damage.
Construction/Loadline › Hull › Side Shell
Issued 22 May 2008 Resolved
Repair hair line crack inboard stbd hull fwd.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Construction/Loadline › Hull › Side Shell
Issued 22 May 2008 Resolved
Repair loose rub rail fwd outboard stbd hull.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Construction/Loadline › Hull › Side Shell
Issued 22 May 2008 Resolved
Check and tighten all loose rub rail bolts.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Construction/Loadline › Structures › Manhole
Issued 22 May 2008 Resolved
Replace both fwd manhole covers hinges.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 22 May 2008 Resolved
Repair engine mount bolts on both port and stbd engines - next available dry dock.
Action required: 705 - Other - as specified
Due 6 June 2010
Resolved 4 June 2010
Resolution: Vessels rep replaced both MDE''s engine moutns and hardware with all new factory Cumming parts; all sat!
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 22 May 2008 Resolved
Replace worn engine mount fwd stbd engine - next available dry dock.
Action required: 705 - Other - as specified
Due 6 June 2010
Resolved 4 June 2010
Resolution: Vessel owner replaced all the worn stbd engine mounts with factory new islolator mounts.
Construction/Loadline › Structures › Superstructure
Issued 22 May 2008 Resolved
Repair damage bolt hole on port seat next to captain station.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Resolution: Vessels reps repaired seating surface, all sat.
Construction/Loadline › Hull › Side Shell
Issued 22 May 2008 Resolved
Repair aft railing.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 28 May 2008
Resolution: Vessel reps hired Pacific welding to repair all damaged rails.
Personnel › Training › First Aid/CPR
Issued 5 September 2007 Resolved
Provide First Aid/CPR training for al crewmembers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 19 September 2007
Lifesaving › Lifebuoys › Serviceable
Issued 5 September 2007 Resolved
Replace Life Ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 19 September 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 5 September 2007 Resolved
Replace Magnetic Compass light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 19 September 2007
Fire Fighting › Fire Bucket › Availability
Issued 5 September 2007 Resolved
Provide three fire buckets.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 19 September 2007
Construction/Loadline › Structures › Superstructure
Issued 5 September 2007 Resolved
Make mid section of vessel available for inspection (fuel tanks, bilge, etc..)
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 19 September 2007
Engineering › Bilge Water Management System › Pump
Issued 5 September 2007 Resolved
Secure bilge pumps and wires on both port and starboard engine compartments.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 20 September 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 September 2007 Resolved
Replace screws on panel against port side collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 20 September 2007
Deck/Cargo › Holds/Tanks › Coaming
Issued 5 September 2007 Resolved
Replace coaming seals on all three forward hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 19 September 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 September 2007 Resolved
Replace port and starboard navigation light lenses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2007
Resolved 19 September 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 5 September 2007 Resolved
Replace fuel filler hose in port bilge.
Due 3 October 2007
Resolved 20 September 2007
Engineering › Bilge Water Management System › Valve
Issued 5 September 2007 Resolved
Replace valve on starboard forward bilge piping.
Due 3 October 2007
Resolved 20 September 2007
Engineering › Bilge Water Management System › Pump
Issued 5 September 2007 Resolved
Secure starboard forward bilge pump.
Due 3 October 2007
Resolved 20 September 2007
Engineering › Bilge Water Management System › Pump
Issued 5 September 2007 Resolved
Secure aft port and starboard bilge pumps.
Due 3 October 2007
Resolved 20 September 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 5 September 2007 Resolved
Make bulkhead watertight where wires pass through to port/starboard engine space.
Due 3 October 2007
Resolved 20 September 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 20 September 2005 Resolved
Replace piping on air intake on stbd engine.
Due 4 October 2005
Resolved 3 October 2005
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 20 September 2005 Resolved
Demonstrate proper operation of ventilation closures.
Due 4 October 2005
Resolved 3 October 2005
Engineering › Fuel Oil Service System › Valve, Control
Issued 20 September 2005 Resolved
Show proper operation of remote fuel shutoff valves.
Due 4 October 2005
Resolved 3 October 2005
Engineering › Fuel Oil Service System › Hose
Issued 20 September 2005 Resolved
Replace fuel hoses with SAE J-1942 or equivalent.
Due 4 October 2005
Resolved 3 October 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 September 2005 Resolved
Label visual indicators on alarm panel.
Due 4 October 2005
Resolved 3 October 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 September 2005 Resolved
Replace reflective tape on ring buoy.
Due 4 October 2005
Resolved 3 October 2005
Lifesaving › Lifebuoys › Serviceable
Issued 20 September 2005 Resolved
Replace aft ring buoy.
Due 4 October 2005
Resolved 3 October 2005
Lifesaving › Hand Flares › Storage
Issued 20 September 2005 Resolved
Provide properly marked flare container.
Due 4 October 2005
Resolved 3 October 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 September 2005 Resolved
Provide complete first aid kit.
Due 4 October 2005
Resolved 3 October 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 September 2005 Resolved
Replace stern light.
Due 4 October 2005
Resolved 3 October 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 20 September 2005 Resolved
Provide proof of service of portable fire extinguishers.
Due 4 October 2005
Resolved 3 October 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 20 September 2005 Resolved
Provide proof of servicing.
Due 4 October 2005
Resolved 3 October 2005
Fire Fighting › Fire Bucket › Stenciling
Issued 20 September 2005 Resolved
Stencil fire buckets.
Due 4 October 2005
Resolved 3 October 2005
Engineering › Fuel Oil Service System › Piping
Issued 20 September 2005 Resolved
Install rigid piping on all fuel lines that penatrate water tight bulkheads.
Due 4 October 2005
Resolved 3 October 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 September 2004 Resolved
Post lifejacket donning placards.
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 29 September 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 September 2004 Resolved
Properly label vessel's lifering.
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 29 September 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 September 2004 Resolved
Place a complete first aid kit on board the vessel.
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 29 September 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 September 2004 Resolved
Demonstrate visual indicator for fixed firefighting system discharge (red light).
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 3 October 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 15 September 2004 Resolved
Place two (2) sources of portable lighting on board the vessel.
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 29 September 2004
Stability › Watertight Integrity › General
Issued 15 September 2004 Resolved
Install auto bilge pump indicator lights.
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 29 September 2004
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 15 September 2004 Resolved
Install three (3) safety lines to prevent passengers from entering dive platform unescorted.
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 29 September 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 15 September 2004 Resolved
Place an FCC Radio Safety Certificate on board.
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 29 September 2004
Communications › Alarms/Indicators › High Water Alarm
Issued 15 September 2004 Resolved
Properly label all operating switches/controls.
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 29 September 2004
Documentation › Certificates/Documents › FCC SSL
Issued 3 July 2003 Resolved
Obtain replacement FCC Station License to replace existing license stolen within past year.
Due 3 August 2003
Resolved 15 September 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 3 July 2003 Resolved
Master of vessel to obtain FCC Radio Operator's Permit.
Due 3 August 2003
Resolved 15 September 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 July 2003 Resolved
Attach working waterlight to ring buoy.
Due 3 August 2003
Resolved 15 September 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 July 2003 Resolved
Prove operation of vessel's port running light.
Due 3 August 2003
Resolved 15 September 2004
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 3 July 2003 Resolved
Provide copy of Rules of the Road and maintain on board vessel.
Due 3 August 2003
Resolved 15 September 2004
Communications › Alarms/Indicators › Fire Alarm
Issued 3 July 2003 Resolved
Prove operation of port and starboard engine space fixed gas fire extinguishing system audible alarm.
Due 3 August 2003
Resolved 15 September 2004
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 3 July 2003 Resolved
Prove operation of port and starboard engine tachometers at helm.
Due 3 August 2003
Resolved 15 September 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 July 2003 Resolved
Prove operation of starboard high water bilge indicator light.
Due 3 August 2003
Resolved 15 September 2004
Lifesaving › Buoyant Apparatus
Issued 30 July 2002 Resolved
Retro-reflective tape needs replacement. LEGACY COMPONENT DESC: Life Float
Due 31 August 2002
Resolved 5 September 2002
Resolution: replaced
Engineering › Bilge Water Management System
Issued 30 July 2002 Resolved
Repair or replace high level bilge alarms to be audible from the operator's station. LEGACY COMPONENT DESC: Alarms
Condition: Unknown
Due 31 August 2002
Resolved 5 September 2002
Resolution: alarm sat
Accommodation/Occupational Safety › Occupational Safety
Issued 30 July 2002 Resolved
Provide bolts to secure aft railings. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Due 31 August 2002
Resolved 5 September 2002
Resolution: bolts installed
Documentation › Certificates/Documents
Issued 30 July 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 31 August 2002
Resolved 5 September 2002
Resolution: license and certificate replaced, op permit onhand
Deck/Cargo › Holds/Tanks
Issued 30 July 2002 Resolved
All three forward hatch covers fractured. Repair to good marine practice. LEGACY COMPONENT DESC: Hatch Cover
Condition: Unknown
Due 31 August 2002
Resolved 5 September 2002
Resolution: repaired
Documentation › Manifests/Lists
Issued 30 July 2002 Resolved
Provide Emergency Instruction List. LEGACY COMPONENT DESC: Emergency Checkoff List
Due 31 August 2002
Resolved 5 September 2002
Resolution: posted
Fire Fighting
Issued 28 June 2001 Resolved
Prove operation of audio alarm and visual indicator for fixed fire extinguishing system.
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Navigation
Issued 24 July 2000 Resolved
Replace hydrostatic release for EPIRB that has expired.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Engineering
Issued 24 July 2000 Resolved
Mark remote fuel shut-offs.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Lifesaving
Issued 7 June 1999 Resolved
Obtain the necessary items required to bring the existing 1st aid kit into compliance with 46CFR 184.710.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Navigation
Issued 7 June 1999 Resolved
Prove operation of compass light per 46CFR 184.402(c).
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Fire Fighting
Issued 7 June 1999 Resolved
Provide proof of annual servicing of vessel's portable fire extinguishers per NFPA 10.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Engineering
Issued 7 June 1999 Resolved
Repair or replace inoperative port engine shutdown solenoid.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Fire Fighting
Issued 7 June 1999 Resolved
Mark "FIRE BUCKET" in a contrasting color on the vessel fire buckets per 46CFR 181.610.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Construction/Loadline
Issued 7 June 1999 Resolved
Install visual indicator lights at the operating station for all automatic bilge pumps per 46CFR 182.530(c).
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Construction/Loadline
Issued 29 June 1998 Resolved
Prove the opertion of the visible high level bilge alarms for both the portand starboard hulls.
Condition: Unknown
Due 18 October 1998
Resolved 18 October 1998
Fire Fighting
Issued 29 June 1998 Resolved
Obtain three 2 1/2 gallon buckets with lanyards for use as fire buckets. These buckets shall be stensiled "fire buckets."
Condition: Unknown
Due 18 October 1998
Resolved 18 October 1998
Electrical
Issued 29 June 1998 Resolved
Obtain and provide battery covers of sufficient strength to prevent accidental contact of metal objects across the battery terminals.
Condition: Unknown
Due 18 October 1998
Resolved 18 October 1998
Documentation
Issued 29 June 1998 Resolved
Obtain a valid FCC Station license for the vessel as required in 47 CFR 80.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Lifesaving
Issued 29 June 1998 Resolved
Obtain a life jacket donning placard for both syles of Type I life jackets carried on board the vessel.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Documentation
Issued 29 June 1998 Resolved
Obtain a valid FCC Safety Radiotelephony certificate for the vessel as required in 47 CFR 80.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Navigation
Issued 29 June 1998 Resolved
Prove the operation of the vessel's stern light.
Condition: Unknown
Due 18 October 1998
Resolved 18 October 1998
Documentation
Issued 29 June 1998 Resolved
Obtain a valid FCC Marine operator's permit for at least one crew member and/or licensed captain.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Lifesaving
Issued 29 June 1998 Resolved
Obtain a dry box for the storage of the vessels distress signals. The box shall be stensiled "Distress signals."_x001C_
Condition: Unknown
Due 18 October 1998
Resolved 18 October 1998
Navigation
Issued 29 June 1998 Resolved
Obtain adequate charts and tide tables for the vessel's area of operation.
Condition: Unknown
Due 18 October 1998
Resolved 18 October 1998

Ownership record