← All vessels
ANDRA
ANDRA is a 1982 freight ship. The Coast Guard has recorded 23 inspections since 1994, most recently in November 2007, along with 41 deficiencies and 3 operational controls.
Records from 1994 to 2007. Most recent: inspection, 12 November 2007.
- Built
- 1982
- Last inspected
- 12 November 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 41 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8330528 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FKW8
414521
Flag
PANAMA
—
Maury page id
psix-414521
Inspections, by type
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it13575 - Convention (Subpart B), Gross Ton
4328 - Convention (Subpart B), Net Ton
12280 - Dead Weight, Ton
22287 - Displacement, Ton
4328 - Convention (Subpart B), Net Ton
12280 - Dead Weight, Ton
22287 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
12 November 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3092777
13 March 2006
NPV Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2601736
23 November 2005
ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2539986
14 March 2005
Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2303098
8 July 2004
ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2126046
14 June 2004
Annual Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2098537
13 May 2004
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2043564
10 February 2004
Re-Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1988939
24 June 2003
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1826981
21 June 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1827769
3 April 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 288762
13 January 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 285921
24 August 2000
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 281480
31 July 2000
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 280452
11 August 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 431439
14 December 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 423549
1 July 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 417481
9 December 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 496694
22 January 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 386937
20 June 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 379852
19 January 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 374249
13 October 1994
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 691084
3 October 1994
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 371157
Deficiency record · 41
Lifesaving › Lifeboat › Markings
Issued 14 March 2005
Resolved
Vessel's lifeboat launching instructions (port and starboard) do not match the actual type of lifeboat or launching arrangements onboard. Provide relevant/applicable instructions prior to to next U.S. port after sailing foreign. -SOLAS 74/78 CH.III Reg.9.2.1
Communications › Alarms/Indicators
Issued 10 February 2004
Resolved
Provide an alarm system for the Main Engine high pressure fuel piping. (Indicates fuel leak from high pressure liines.)
Documentation › Safety Management System
Issued 10 February 2004
Resolved
Provide a current GMDSS maintenance contract. LEGACY COMPONENT DESC: Company Responsibility/Authority Documentation
Pollution Prevention/Response › Prevention Equipment
Issued 10 February 2004
Resolved
Provide appropriate containment around each fuel oil or bulk lubricationg oil tank vent, overflow and fill pipe. LEGACY COMPONENT DESC: Fixed Containment
Engineering
Issued 13 January 2001
Resolved
MAKE PERMANENT REPAIRS TO ENGINE READOUTS FOR EMERGENCY GENERATOR. PRIOR TONEXT US PORT. SOLAS 74 (UNAMENDED) II-1/27/2
Electrical
Issued 13 January 2001
Resolved
PROVIDE LIGHT COVERS FOR FLOURESCENT LIGHTING AT HEAD LEVEL IN ENGINE ROOM,PRIOR TO NEXT U.S. PORT OF CALL. NOTED MOST LIGHT COVERS MISSING OR DAMAGED. SOLAS 74 (UNAMENDED) II-1/27
Navigation
Issued 13 January 2001
Resolved
NOTED GYRO COMPASS TO BE INOPERATIVE. NO NOTIFICATION MADE TO U.S.C.G. REPAIR AT SEA BUOY OR REQUEST LETTER OF DEVIATION TO ENTER FROM COTP MOBILEPRIOR TO ENTRY. 33 CFR 164.35 (d)
Engineering
Issued 13 January 2001
Resolved
Replace #1 and #6 fuel oil return lines on main engine. Noted insulation missing and worn. Correct prior to next U.S. port. SOLAS 74 (UNAMENDED)II- 1/27
Engineering
Issued 13 January 2001
Resolved
REPLACE PACKING AND SURROUNDING ADJUSTMENT BOX/GLAND AND FOUNDATION FOR MAIN SEAWATER PUMP. NOTED TO BE WASTED ALMOST TO THE POINT OF UNSERVICEABLE. REPLACE PRIOR TO NEXT U.S. PORT. SOLAS 74 (UNAMENDED) II-1/2
Lifesaving
Issued 31 July 2000
Resolved
No operable toilet in hospital. ILO 147
Deck/Cargo
Issued 31 July 2000
Resolved
Hydraulic fluid leaks on holds #3 and #4 need to be repaired.
Lifesaving
Issued 31 July 2000
Resolved
Repair port and starboard lifeboat davit brakes.
Lifesaving
Issued 31 July 2000
Resolved
Provide documentaion for weak link or replace with approved link.
Fire Fighting
Issued 31 July 2000
Resolved
Replace eight fire hoses in engine room.
Lifesaving
Issued 31 July 2000
Resolved
Perform satisfactory boat drill.
Engineering
Issued 31 July 2000
Resolved
Repair fuel leaks in engine room bilges.
Electrical
Issued 31 July 2000
Resolved
Provide light covers for open lights in Bosn's workspace, forward fire equipment room.
Electrical
Issued 31 July 2000
Resolved
Cover bare electrical board in Bosn's hole.
Electrical
Issued 31 July 2000
Resolved
Properly cover exposed wiring in fan room.
Lifesaving
Issued 31 July 2000
Resolved
Both lifeboats need to be provided with the required amount of water.
Lifesaving
Issued 31 July 2000
Resolved
Open cans of paint and thinner in paint locker need to be covered and secured.
Navigation
Issued 31 July 2000
Resolved
No current charts for area transited.
Fire Fighting
Issued 31 July 2000
Resolved
Incompetent Fire Drill. Solas 74/78 Chap. III Reg. 18.3
Navigation
Issued 31 July 2000
Resolved
No Coast Guard Light List,
Navigation
Issued 31 July 2000
Resolved
No current tide tables.
Fire Fighting
Issued 31 July 2000
Resolved
Fire hose nozzle in fire station F-39, needs to be replaced. It would not open. Solas 74/78 Chap. II-2 Reg. 21_x001C_ _x001C_ _x001C_
Fire Fighting
Issued 31 July 2000
Resolved
Middle bridge fire extinguishers, both port and starboard. Cracked hoses need to be replaced. Solas 74/78 Chap II-2 Reg. 6.5
Lifesaving
Issued 31 July 2000
Resolved
Embarkation ladder for lifeboat could not reach water.
Accommodation/Occupational Safety
Issued 31 July 2000
Resolved
Pilot ladder could not reach water with 15 degree list.
Lifesaving
Issued 31 July 2000
Resolved
Gear stowed in electrical closets 140 and 233. Solas 74/78 Chap. I Reg. 11(a). _x001C_ _x001C_
Construction/Loadline
Issued 11 August 1999
Resolved
PUMP OUT TO AN APPROVED SHORESIDE FACILITY, THE 2 FEET OF OIL/WATER SLOPS FROM THE PIPE TUNNEL, AND PROVIDE A RECIEPT PRIOR TO DEPARTURE._x001C_ MARPOL 73/78 ANNEX I/14
Documentation
Issued 11 August 1999
Resolved
HAVE CLASS OR DESIGNATED FLAG STATE CLASS REPRESENTATIVE ATTEST TO THE CORRECT ADMEASUREMENT OF THE PLIMSOLL AND LOADLINE AS INDICATED ON THE INTERNATIONAL LOAD LINE CERTIFICATE, AND PROVIDE REPORT BEFORE RETURN TO NEXT U.S. PORT. ICLL 66 REG. 6
Documentation
Issued 14 December 1998
Resolved
Provide on board vessel proper flag state licenses for all officers. See STCW 78 II/4.
Accommodation/Occupational Safety
Issued 1 July 1998
Resolved
MSD SEWAGE PUMP LEAKS EXCESSIVELY. REPAIR/RENEW BY 03 JULY 98.
Deck/Cargo
Issued 1 July 1998
Resolved
NO MARPOL CONNECTION ON BOARD. PROVIDE MARPOL CONNECTION PRIOR TO 01 AUG 98.
Electrical
Issued 1 July 1998
Resolved
FUEL LEAK, FUEL FILTERS, ON SHIP SERVICE GENERATOR. REPAIR/RENEW PRIOR TO 03 JULY 98.
Navigation
Issued 1 July 1998
Resolved
EMERGENCY STEERING SYSTEM VIBRATES AND MAKES EXCESSIVE NOICE. REPAIR/RENEW, PROVIDE CLASS REPORT PRIOR TO 03 JULY 98.
Navigation
Issued 3 October 1994
Resolved
VESSEL DID NOT HAVE THE REQUIRED STEERING GEAR CHANGE OVER PROCEDURES POSTED ON THE BRIDGE._x001C_ _x001C_ _x001C_
Documentation
Issued 3 October 1994
Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 3 October 1994
Resolved
VESSEL'S CHARTS AND PUBS WERE OUTDATED - 1993.
Navigation
Issued 3 October 1994
Resolved
VESSEL'S MANUEVERING DATA SHEET WAS NOT COMPLETE.