← All vessels
MATA RANI
MATA RANI is a 1970 freight ship. The Coast Guard has recorded 20 inspections since 1994, most recently in April 1999, along with 107 deficiencies — 7 with no resolution recorded — and 4 operational controls.
Records from 1994 to 1999. Most recent: inspection, 24 April 1999.
- Built
- 1970
- Last inspected
- 24 April 1999
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 107 recorded · 7 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7042655 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
414585
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-414585
Inspections, by type
…with no type recorded18
…past their stated due date7
Years with a record
6 calendar years (1994–1999)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it1705 - Regulatory (Subpart C or D), Gross Ton
1085 - Regulatory (Subpart C or D), Net Ton
2908 - Dead Weight, Ton
1085 - Regulatory (Subpart C or D), Net Ton
2908 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
24 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 23930
14 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 427969
14 April 1999
Port Security Assessment
Type not classified · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 600788
13 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 155227
9 February 1998
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 412767
10 June 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 207113
10 June 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 756488
9 June 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 404484
2 July 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 392857
1 May 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 717992
30 April 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 390684
13 February 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 387768
29 October 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 384233
20 June 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 712201
19 June 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 484330
23 November 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 706803
22 November 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 372628
25 October 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 706806
24 October 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 371724
24 October 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 863517
Deficiency record · 107
Documentation
Issued 14 April 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline
Issued 14 April 1999
Resolved
SEVERAL WTD'S HAVE WORN GASKETS AND ARE MISSING DOGS.
Engineering
Issued 14 April 1999
Resolved
EXHAUST LEAK ON STBD GENERATOR.
Construction/Loadline
Issued 14 April 1999
No resolution recorded
PERMANENT REPAIRS ARE TO BE COMPLETED TO CARGO HOLD STRUCTRUAL FRAMING MEMBERS.
Electrical
Issued 14 April 1999
Resolved
DEAD END WIRING ON BRIDGE, GALLEY AND CREW CABINS.
Accommodation/Occupational Safety
Issued 14 April 1999
Resolved
EMBARGATION LADDER IS NOT READY FOR IMMEDIATE USE. NOT PROPERLY SECURED TO DECK.
Fire Fighting
Issued 14 April 1999
Resolved
FIRE DRILL WAS UNSATISFACTORY.
Deck/Cargo
Issued 14 April 1999
No resolution recorded
MAKE PERMANENT REPAIRS TO HYDRAULIC PIPING IN WAY OF CEMENT PATCH & REPAIR LEAKING HYDRAULICS ON DECK.
Electrical
Issued 14 April 1999
No resolution recorded
REPAIR WIRING AND OPEN ELECTRICAL LIGHTING FIXTURES IN GALLEY LIGHTING SYSTEM.
Electrical
Issued 14 April 1999
No resolution recorded
REMOVE TEMP GENERATOR INSTALLED ON AFT DECK AND INSTALL #2 GENERATOR BACK INTO ENGINE ROOM.
Construction/Loadline
Issued 14 April 1999
No resolution recorded
MAKE PERMANENT REPAIRS TO COLLISION BULKHEAD AND FRAMING.
Construction/Loadline
Issued 14 April 1999
No resolution recorded
MAKE PERMANENT REPAIRS OF AFT CARGO HOLK DECK IN WAY OF DOUBLER PLATES OR PROVIDE CLASS APPROVAL WITH GAUGING REPORT OF AREA.
Documentation
Issued 14 April 1999
No resolution recorded
PROVIDE TWO GMDSS OPERATORS ON BOARD IAW SAFE MANNING DOC.
Construction/Loadline
Issued 14 April 1999
Resolved
HATCH COVERS ARE DETERIORATED AND DAMAGED. GASKETS ARE WORN. MUST PASS HOSETEST PRIOR TO DEPARTURE.
Construction/Loadline
Issued 14 April 1999
Resolved
STRUCTURAL MEMBERS (FRAMES) IN CARGO HOLD ARE DETERIORATED. PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Construction/Loadline
Issued 14 April 1999
Resolved
FUEL OIL IN THE VINCINITY OF #3 BALLAST TANK VENT. HAVE CLASS PRIOVIDE REPORT ON CONTENTS AND CONDITION OF TANK.
Construction/Loadline
Issued 14 April 1999
Resolved
EMERGENCY FIRE PUMP ROOM IS FILLED WITH WATER. PROVIDE CLASS REPORT ON SOURCE OF WATER.
Accommodation/Occupational Safety
Issued 14 April 1999
Resolved
POTABLE WATER IS SUSPECTED AS BEING CONTAMINATED. PROVIDE WATER QUALITY REPORT OR RENEW WATER IN TANKS.
Engineering
Issued 14 April 1999
Resolved
EMERGENCY GENERATOR MISSING GUARDS ON BELT.
Engineering
Issued 14 April 1999
Resolved
GENERATOR EXHAUST PIPE IN UPPER ENGINE ROOM IS HOT. LAGGING NEEDS TO BE REPLACED.
Engineering
Issued 14 April 1999
Resolved
PORT GENERATOR LEAKING FUEL FROM SUPPLY LINE.
Fire Fighting
Issued 14 April 1999
Resolved
AUTOMATIC CLOSURE ON ENGINE ROOM ESCAPE HATCH IS INOPERABLE.
Electrical
Issued 14 April 1999
Resolved
LIGHT COVERS MISSING THROUGHOUT VESSEL.
Lifesaving
Issued 14 April 1999
Resolved
LIFEBOAT LOWERING INSRUCTIONS ARE UNSATISFACTORY.
Lifesaving
Issued 14 April 1999
Resolved
RETO-REFLECTIVE TAPE MISSING FROM BOTTOM OF LIFEBOAT.
Construction/Loadline
Issued 14 April 1999
Resolved
HYDRALIC OIL PIPE ON FWD STBD WX DECK HAS CEMENT PATCH. PIPE IS FOR CARGO HATCH COVERS.
Lifesaving
Issued 14 April 1999
Resolved
RETO-REFLECTIVE TAPE ON BOARD VESSEL IS NOT SOLAS APPROVED.
Accommodation/Occupational Safety
Issued 14 April 1999
Resolved
MEAT LOCKER DOOR IS MISSING INSIDE HANDLE.
Lifesaving
Issued 14 April 1999
Resolved
LIFE JACKETS MISSING LIGHTS AND WHISTLES.
Fire Fighting
Issued 14 April 1999
Resolved
FIRESUITS STORED IN SAME LOCATION.
Fire Fighting
Issued 14 April 1999
Resolved
FIRE CONTROL PLAN NOT UP TO DATE.
Fire Fighting
Issued 9 February 1998
Resolved
Crew were not properly trained in firefighting.
Fire Fighting
Issued 9 February 1998
Resolved
ZIPPER WAS BROKEN ON TOP HALF OF FIREFIGHTING OUTFIT.
Accommodation/Occupational Safety
Issued 9 June 1997
Resolved
Clean grease from galley vent system to ensure proper ventilation._x001C_ SOLAS 60 REG II/47(d)
Fire Fighting
Issued 9 June 1997
Resolved
Demonstrate proper operation of emergency fire pump upon next US port call._x001C_ SOLAS 60 REG II 56/(c)
Lifesaving
Issued 9 June 1997
Resolved
Provide appropriate number of ring buoys with lights. Vessel was missing one required ring buoy with self igniting light._x001C_ SOLAS 60 REG III/21(e)
Construction/Loadline
Issued 9 June 1997
Resolved
Repair wastage to chain pipe leading to chain locker in the forepeak. _x001C_ ILLC 66 Annex I/1
Construction/Loadline
Issued 9 June 1997
Resolved
Ensure watertight skylight over engine room can be closed and secured._x001C_ ILLC 66 Annex I/12
Navigation
Issued 9 June 1997
Resolved
Replace/repair inoperable engine room telephone._x001C_ SOLAS 60 REG II/33
Accommodation/Occupational Safety
Issued 9 June 1997
Resolved
MSD certificate not on board._x001C_ 33 CFR 159/MARPOL 73/78 Annex IV REG 4-7
Accommodation/Occupational Safety
Issued 9 June 1997
Resolved
Prove proper operation of MSD. Unit was leaking and venting into engine room. Vessel also lacked appropriate chemicals to operate system. _x001C_ 33 CFR 159/MARPOL 73/78 Annex IV REG 3(1)
Electrical
Issued 2 July 1996
Resolved
Prior to return U.S. Waters provide covers for lights in main passageway, provide Class report stating all covers in place.
Engineering
Issued 30 April 1996
Resolved
Vessel personnel could not provide a weather tight cover for the # 4 fuel tank vent as required by the International Convention on Load Lines Reg 19.The vessels vent was completely uncovered exposing the 6" vent to the weather.
Electrical
Issued 30 April 1996
Resolved
Provide a cover for differential switch electrical box of the refrigerationunit.
Electrical
Issued 30 April 1996
Resolved
Provide properly installed/maintained electrical cables/conduit which wouldprevent downflooding into the watertight compartments of the forepeak.
Electrical
Issued 30 April 1996
Resolved
Provide repairs or replace electrical cables for the deck lights to remove the exposed splices to prevent electrical shock.
Electrical
Issued 30 April 1996
Resolved
Provide covers for all lights throughout the ship to prevent electrical shock.
Lifesaving
Issued 30 April 1996
Resolved
Vessel to provide Markings on the Lifeboat as required by Solas 74 Regulation 41.9. All of the life boat's markings had recently been painted over.
Navigation
Issued 30 April 1996
Resolved
Vessel personnel could not provide the boarding officers with a currently corrected chart for area transited during entrance into the Port of Savannah. The vessel did not have the required chart or a foreign equivalent. The master stated he used B.A. 2801(East Coast Of U.S.).
Navigation
Issued 13 February 1996
Resolved
PRIOR TO RETURNING TO U.S. PORT, UPDATE CHART #3848 AND PROVIDE APPROPRIATELIGHT LIST VOLUME AND COAST PILOT FOR AREA OF OPERATION.
Navigation
Issued 13 February 1996
Resolved
PRIOR TO ENTERING NEXT U. S. PORT, CONDUCT REQUIRED ENTRIES IN LOG FOR ARRIVAL IN PORT.
Fire Fighting
Issued 13 February 1996
Resolved
PRIOR TO RETURN TO U.S. PORT, LOG FIRE DRILL.
Fire Fighting
Issued 13 February 1996
Resolved
PRIOR TO RETURNING TO U.S., UPDATE FIRE CONTROL PLANS.
Lifesaving
Issued 13 February 1996
Resolved
PRIOR TO RETURNING TO U.S., PROVIDE LIFESAVING MAINTENANCE LOG.
Electrical
Issued 13 February 1996
Resolved
PRIOR TO RETURNING TO U.S., REPAIR/REMOVE LIGHT FIXTURE IN BOSN'S LOCKER POTRSIDE AFT MAIN DECK.
Engineering
Issued 13 February 1996
Resolved
PRIOR TO BUNKERING IN U.S. WATERS, CONDUCT AND DOCUMENT HYDROSTATIC TEST OFBUNKERING PIPING.
Lifesaving
Issued 29 October 1995
Resolved
RENEW/INSTALL RETRO-REFLECTIVE MATERIAL TO LIFEBOATS IN ACCORDANCE W/SOLAS 74(AMENDED) III/30.2.7.
Lifesaving
Issued 29 October 1995
Resolved
PROVIDE 3 TWO WAY RADIO APPARATUS IN ACCORDANCE WITH SOLAS 74(AMENDED) III/6.2.1.
Lifesaving
Issued 29 October 1995
Resolved
PROVIDE EVIDENCE THAT DAVIT FALLS HAVE BEEN RENEWED WITHIN THE PAST 5 YEARSAND/OR END OR ENDED WITHIN 30 MONTHS. IAW SOLAS 74(AMENDED) II/19.4
Electrical
Issued 29 October 1995
Resolved
PROVE OPERATION OF EMERGENCY GENERATOR UNDER A LOADED CONDITION. REPAIR VOLT/AMP METER FOR EMERGENCY GENERATOR INSTALLATION.
Lifesaving
Issued 29 October 1995
Resolved
RENEW/PROVIDE LIFEBOAT EQUIPMENT IN ACCORDANCE WITH SOLAS 74(AMENDED) III/11.
Electrical
Issued 29 October 1995
Resolved
PROVE OPERATION OF EMERGENCY LIGHTING THROUGHOUT VESSEL.
Lifesaving
Issued 29 October 1995
Resolved
UPDATE MUSTER LIST AND EMERGENCY INSTRUCTIONS SHOWING CREW MEMBER DUTIES AND IN THE LANGUAGE UNDERSTOOD BY THE CREW IN ACCORDANCE WITH SOLAS 74(AMENDED) III/8.
Fire Fighting
Issued 29 October 1995
Resolved
REPAIR/SERVICE SEMI-PORTABLE FIRE EXTINGUISHER LOCATED IN MACHINERY SPACE. SEE SOLAS 74(AMENDED) II-2/21.
Fire Fighting
Issued 29 October 1995
Resolved
REPAIR AND PROVE OPERATION OF EMERGENCY FIRE PUMP. SEE SOLAS 74(AMENDED) II-2/21.
Navigation
Issued 29 October 1995
Resolved
REMOVE DEBRIS FROM STEERING GEAR ROOM EMERGENCY ESCAPE. SEE SOLAS 74(AMENDED) II-2/45.
Engineering
Issued 29 October 1995
Resolved
PROVE OPERATION OF 15 PPM ALARM FOR OILY WATER SEPERATING DEVICE AS REQUIRED BY FLAG ADMINSTRATION ISSUED I.O.P.P. CERTIFICATE.
Navigation
Issued 29 October 1995
Resolved
PROVIDES OPERATING INSTRUCTIONS FOR STEERING GEAR. OPERATING INSTRUCTIONS SHALL BE POSTED ON THE NAVIGATING BRIDGE AND STEERING GEAR COMPARTMENT. SEE SOLAS 74(AMENDED) V/19-2(c),(i).
Navigation
Issued 29 October 1995
Resolved
PROVE OPERATION OF EMERGENCY STEERING FROM STEERING COMPARTMENT.
Accommodation/Occupational Safety
Issued 29 October 1995
Resolved
REPAIR/PROVE OPERATION OF MARINE SANITATION DEVICE.
Lifesaving
Issued 29 October 1995
Resolved
EMBARKATION LADDER SHALL BE PROVIDED FOR PORT AND STARBOARD SURVIVAL CRAFT OF SUFFICIENT LENGTH TO REACH FROM THE DECK TO THE WATERLINE IN THE LIGHTEST SEAGOING CONDITION UNDER UNFAVORABLE CONDITIONS OF TRIM. SEE SOLAS74(AMENDED)III/11.
Lifesaving
Issued 29 October 1995
Resolved
POSTERS OR SIGNS SHALL BE PROVIDED ON OR IN THE VINCINITY OF SURVIVAL CRAFTAND THIER LAUNCHING CONTROLS IN ACCORDANCE WITH SOLAS 74(AMENDED) III/9.
Fire Fighting
Issued 29 October 1995
Resolved
PROVIDE INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL INSTALLATIONS/ EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE. SEE SOLAS 74(AMENDED) II- 2/20.
Lifesaving
Issued 29 October 1995
Resolved
PROVIDE TRAINING MANUAL FOR LIFESAVING APPLIANCES IN ACCORDANCE WITH SOLAS 74(AMENDED) III/19.3/52.
Lifesaving
Issued 29 October 1995
Resolved
PROVE THAT SMOKE SIGNAL/LIGHT ARRANGMENT TO BRIDGE WING RING LIFE BOUY WILLQUICK RELEASE. PRESENT ARRANGEMENT DOESN'T PROVIDE A QUICK RELEASE ARRANGEMENT.
Lifesaving
Issued 29 October 1995
Resolved
RENEW EXTINGUISHED SELF-IGNITING LIGHT AND SMOKE SIGNAL TO STARBOARD BRIDGEWING RING LIFE BOUY. SEE SOLAS 60 III/21(e),(g).
Fire Fighting
Issued 29 October 1995
Resolved
PROVIDE ONE ADDITIONAL FIREMANS OUTFITS IN ACCORDANCE WITH SOLAS(AMENDED) II-2/17.3.
Lifesaving
Issued 29 October 1995
Resolved
RENEW OUTDATED HYDROSTATIC RELEASE TO E.P.I.R.B. SEE SOLAS 74(AMENDED) IV/7
Lifesaving
Issued 29 October 1995
Resolved
PROVIDE EVIDENCE OF BATTERY RENEWAL TO E.P.I.R.B. W/NEW EXPIRATION DATE. SEE SOLAS 74(AMENDED) IV/7.
Lifesaving
Issued 29 October 1995
Resolved
RENEW INOPERATIVE WATERLIGHT TO RING LIFE BOUY LOCATED ON AFT MAIN DECK._x001C_ SOLAS 60 III/21(e),(g)_x001C_ _x001C_ _x001C_
Lifesaving
Issued 29 October 1995
Resolved
RENEW RETROREFLECTIVE MATERIAL TO ALL RING LIFE BOUYS IN ACCORDANCE WITH SOLAS 74(AMENDED) III/30.2.7
Lifesaving
Issued 29 October 1995
Resolved
RENEW AND PROVE OPERATION OF SELF-IGNITING LIGHT TO PORT BRIDGE WING RING LIFE BOUY. SEE SOLAS 60 III/21(e),(g).
Construction/Loadline
Issued 29 October 1995
Resolved
INVESTIGATE CAUSE AND SOLUTION TO DETERIORATION OF AFT MAIN DECK PLATING TOTHE SATISFACTION OF THE ATTENDING GL CLASS SURVEYOR AT NEXT DRYDOCK PERIOD.
Lifesaving
Issued 29 October 1995
Resolved
PROVIDE INSTRUCTIONS FOR ON BOARD MAINTENANCE OF LIFESAVING APPLIANCE IN ACCORDANCE WITH SOLAS 74(AMENDED) III/19.3/52.
Construction/Loadline
Issued 29 October 1995
Resolved
PROVIDE GASKETS FOR WATER/WEATHERTIGHT CLOSURES ON MAIN DECK FOWARD IN WAY OF FOREPEAK.
Accommodation/Occupational Safety
Issued 29 October 1995
Resolved
REPAIR/RENEW/LUBRICATE ALL VENT/FIRE DAMPER CLOSURES FOR SMOOTH OPERATION.
Electrical
Issued 29 October 1995
Resolved
PROVE OPERATION OF STANDBY GENERATOR_x001C_ a) LOAD SHARING b) BLACKOUT PROCEDURES METHODS TO START ENGINE AUTOMATICALLY OR MANUALLY.
Fire Fighting
Issued 29 October 1995
Resolved
PROPERLY IDENTIFY PAINT LOCKER FIRE SPRINKLER SYSTEM ACTIVATION VALVES ON ADJACENT BULKHEAD.
Fire Fighting
Issued 29 October 1995
Resolved
CONDUCTED FIRE DRILL IN THE PRESENCE OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR IN ACCORDANCE WITH SOLAS 74(AMENDED) II/18.3.4-3.9.
Lifesaving
Issued 29 October 1995
Resolved
INFLATABLE LIFERAFT CONTAINERS SHALL BE MARKED IN ACCORDANCE WITH SOLAS 74(AMENDED) III/39.7.3.
Navigation
Issued 29 October 1995
Resolved
UPDATE CHARTS AND PUBLICATIONS TO LATEST REVISIONS FOR U.S. WATERS AND INTENDED VOYAGE IN ACCORDANCE W/ SOLAS 74(AMENDED) V/20.
Engineering
Issued 29 October 1995
Resolved
REMOVE OIL FROM ENGINE ROOM BILGE AND ENGINE ROOM SURFACES WHICH IS CREATING A POTENTIAL FIRE AND SAFETY HAZARD.
Engineering
Issued 29 October 1995
Resolved
REPAIR FUEL OIL LEAK ON FUEL OIL PURIFIER INBOARD LOCATED FOWARD OF #2 GENERATOR.
Navigation
Issued 29 October 1995
Resolved
REMOVE ALL OIL AND OIL RESIDUE FROM STEERING GEAR COMPARTMENT.
Navigation
Issued 29 October 1995
Resolved
REMOVE ALL FLAMMABLE MATERIAL FROM STEERING GEAR ROOM AND STORE IN PAINT LOCKER. IE: PAINT,GASOLINE,ETC.
Lifesaving
Issued 29 October 1995
Resolved
RENEW DEFECTIVE LIGHTS TO 8 LIFEJACKETS AND THREE WITH BROKEN SECURING BUCKLES LOCATED IN (2) LIFEBOAT (6) ON AFT BOAT DECK LIFEJACKET LOCKER.
Fire Fighting
Issued 29 October 1995
Resolved
UPDATE FIRE CONTROL PLAN TO REFLECTIVE ACTUAL LOCATION AND EQUIPMENT ON BOARD VESSEL IN ACCORDANCE WITH SOLAS 74(AMENDED) II-2/20.
Navigation
Issued 22 November 1994
Resolved
The vessel was in violation of 33 CFR 88 when they had no inland navigationrules onboard.
Navigation
Issued 22 November 1994
Resolved
The vessel was in violation of SOLAS V, regulation 20 when they had no local chart of the Savannah River.
Navigation
Issued 22 November 1994
Resolved
The vessel was in violation of SOLAS V, regulation 20 when they had no Coast Pilot for the area transitted.
Navigation
Issued 24 October 1994
Resolved
INLAND NAVIGATIONAL RULES NOT ONBOARD.
Accommodation/Occupational Safety
Issued 24 October 1994
Resolved
REEFER EMERGENCY ESCAPE HANDLE MISSING. BUZZARD DOES NOT FUNCTION EITHER.
Electrical
Issued 24 October 1994
Resolved
FLOURESCENT LIGHT OVER WORK BENCH IN ENGINE ROOM NEEDS PERMANENT WIRING.
Accommodation/Occupational Safety
Issued 24 October 1994
Resolved
VSL WAS OPERATING IN U.S. WATERS WITH NO MARINE SANITATION DEVICE ONBOARD. VESSEL WAS PUMPING RAW SEWAGE OVERBOARD INTO THE MISSIPPI RIVER. NAVIGABLEWATERS OF THE U.S._x001C_
Construction/Loadline
Issued 24 October 1994
Resolved
VESSELS BILGE PUMP DOES NOT OPERATE
Construction/Loadline
Issued 24 October 1994
Resolved
WATERTIGHT DOORS (PAINT LOCKER, CO2 ROOM AND EMERGENCY GENARATOR ROOM) NOT WATERTIGHT DUE TO LOOSE DOGS.
Electrical
Issued 24 October 1994
Resolved
FOUR FLOURESCENT LIGHTS IN FOWARD STOREROOM MISSING COVERS.