Records from 2000 to 2008. Most recent: inspection, 27 June 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
27 June 2008
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3249662
26 April 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2916073
26 March 2007
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2895179
12 July 2006
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2674614
20 April 2005
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2339574
1 April 2005
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2324496
15 December 2004
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2259655
1 April 2004
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2035356
9 March 2004
Examination of Repairs · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1994034
9 April 2002
Hull Examination · Internal Structural Exam · Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1602633
25 July 2000
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1051500
9 March 2000
Hull Examination · Plan Review "T" Boat · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1440237
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 26 March 2007
Resolved
Provide CPR certification documentation.
Due 26 April 2007
Resolved 26 April 2007
Personnel › Certificates/Documents/Licenses › License, Master
Issued 26 March 2007
Resolved
Captain of vessel must provide license.
Due 26 April 2007
Resolved 26 April 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 March 2007
Resolved
Procure new first aid kit.
Due 26 April 2007
Resolved 26 April 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 26 March 2007
Resolved
Repair engine room's portside light fixture.
Due 26 April 2007
Resolved 26 April 2007
Fire Fighting › Fire Bucket › Availability
Issued 26 March 2007
Resolved
Procure three 2.5 gallons buckets; label and install lanyards on each bucket.
Due 26 April 2007
Resolved 26 April 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 March 2007
Resolved
Remove oil, water and trash from engine room bilges.
Due 26 April 2007
Resolved 26 April 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 March 2007
Resolved
Procure Coast Guard light list.
Due 26 April 2007
Resolved 26 April 2007
Navigation › Piloting/Steering › Marine Charts
Issued 26 March 2007
Resolved
Procure charts for area of operation.
Due 26 April 2007
Resolved 26 April 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 26 March 2007
Resolved
Procure tide/tidal current tables.
Due 26 April 2007
Resolved 26 April 2007
Lifesaving › Hand Flares › Not on Board
Issued 26 March 2007
Resolved
Procure flares (three red and three green).
Due 26 April 2007
Resolved 26 April 2007
Operations/Management › Drills/Instruction › Fire
Issued 26 March 2007
No resolution recorded
Perform fire drill in the present of US Coast Guard.
Due 26 April 2007 — due date passed with no resolution recorded
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 March 2007
Resolved
Provide service documentation for fixed system.
Due 26 April 2007
Resolved 26 April 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 March 2007
Resolved
Provide service documentation.
Due 26 April 2007
Resolved 26 April 2007
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 26 March 2007
Resolved
Double clamp hoses on fresh and raw systems.
Due 26 April 2007
Resolved 26 April 2007
Stability › Watertight Integrity › General
Issued 26 March 2007
Resolved
Replace broken windows in pilot/wheel house.
Due 26 April 2007
Resolved 26 April 2007
Electrical › Electric Generation Source (service) › Switch
Issued 26 March 2007
Resolved
Repair battery charger.
Due 26 April 2007
Resolved 26 April 2007
Electrical › Lighting (service) › Outlet Box
Issued 1 April 2005
Resolved
120V Receptacle in pilot house needs mounting.
Condition: Unknown
Due 29 April 2005
Resolved 20 April 2005
Resolution: receptacle mounted
Documentation › Certificates/Documents › FCC SSL
Issued 1 April 2005
Resolved
CPR certification not valid
Condition: Placed in Improper Service
Due 29 April 2005
Resolved 20 April 2005
Resolution: CPR Certification has been renewed
Engineering › Diesel Engine (propulsion-electric) › Bedplate
Issued 1 April 2005
Resolved
Engine mounts need double hose clamps.
Condition: Unknown
Due 29 April 2005
Resolved 20 April 2005
Resolution: Added an additional nut to engine mounts.
Engineering › Diesel Engine (propulsion-electric) › Crankcase
Issued 1 April 2005
Resolved
Replace PVC piping on crankase exhaust .
Condition: Unknown
Due 29 April 2005
Resolved 20 April 2005
Resolution: Renewed with steel nipple.
Electrical › Lighting (service) › Outlet Box
Issued 1 April 2005
Resolved
Replace 2 junction boxes in engine room with metallic boxes.
Condition: Unknown
Due 29 April 2005
Resolved 20 April 2005
Resolution: Two metal electrical junction boxes were installed to replace existing boxes.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 9 March 2004
Resolved
Replace main engines raw water hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2004
Resolved 1 April 2004
Resolution: Installed new water hose.
Engineering › Freshwater System (air cooling)
Issued 9 March 2004
Resolved
Replace PVC fitting IWO A/C water intake with metalic fitting.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2004
Resolved 1 April 2004
Resolution: New PVC fitting installed.
Personnel › Certificates/Documents/Licenses
Issued 9 March 2004
Resolved
Provide FCC operator liscence. LEGACY COMPONENT DESC: License, Radio Officer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2004
Resolved 1 April 2004
Resolution: FCC operator liscence provided.
Electrical
Issued 9 March 2000
Resolved
Provide wall mounted flashlight in way of passenger accomodation space doorto meet the intent of 46 CFR 183.432.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Engineering
Issued 9 March 2000
Resolved
Refurbish main engine and generator fuel piping to meet 46 CFR 182.455._x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 June 2000
Resolved 1 April 2004
Resolution: Fuel piping replacement completed. The area of concern was replaced with steel covered hose, all sat. Inspected the repair, all sat.
Lifesaving
Issued 9 March 2000
Resolved
Provide evidence that furniture meets 46 CFR 116.423 per 46 CFR_x001C_ 177.410(c)(5)
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Lifesaving
Issued 9 March 2000
Resolved
Provide Carbon Dioxide monitor in passenger accom space per 46 CFR 176/800
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Lifesaving
Issued 9 March 2000
Resolved
Provide evidence that all window glass is safety glass per 177.100
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Documentation
Issued 9 March 2000
Resolved
Send payment for user fees per 2.10-101.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Engineering
Issued 9 March 2000
Resolved
Provide fuel system cutoff at fuel tank per 182.455(b)(4)
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 June 2000
Resolved 1 April 2007
Resolution: Conducted repari check, all sat.
Construction/Loadline
Issued 9 March 2000
No resolution recorded
Vessel to remove 24" X 18" doubler placed on stbd side, midships at the_x001C_ next vesel drydocking not to exceed 19JAN02 provided the doubler shows no_x001C_ signs of failure or detioration.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 March 2007 — due date passed with no resolution recorded
Documentation
Issued 9 March 2000
Resolved
Complete satisfactory plan review with this office.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 August 2000
Resolved 1 April 2004
Resolution: Completed plan review.