MAURY USCG vessel records Sign in
← All vessels

HEIDRUN

HEIDRUN is a 1994 public freight. The Coast Guard has recorded 27 inspections since 1996, most recently in August 2026, along with 6 deficiencies and 3 operational controls.

Records from 1996 to 2026. Most recent: inspection, 7 August 2026.

Built
1994
Last inspected
7 August 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9081320 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
414839
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-414839

Inspections, by type

…with no type recorded5
Years with a record 17 calendar years (1996–2026)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it16910 - Displacement, Metric Ton
8448 - Convention (Subpart B), Gross Ton
4651 - Convention (Subpart B), Net Ton
12730 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

7 August 2026 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8457584
2 July 2026 PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8416485
26 June 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8416632
26 July 2025 Administrative Inspection · PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8195194
4 April 2025 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8102725
2 April 2025 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8103832
30 May 2023 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7700562
27 October 2022 PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7582787
10 June 2021 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7221145
26 June 2020 PSC B
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6987439
24 June 2020 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6985458
27 January 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6897062
12 March 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6640909
6 March 2019 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6636102
19 February 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6627875
29 June 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6459420
4 July 2016 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5931917
22 June 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5915213
7 September 2010 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3844296
17 September 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3326818
5 August 2008 ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3289794
12 May 2005 Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2390350
15 October 2004 ISPS II Exam · NPV Safety Exam · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2220364
4 June 2002 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1627113
17 October 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 463845
6 October 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 408574
22 April 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 390035

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 October 2022 Resolved
The activation of any detector or manual operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. If the signals have not received attention within two minutes an audible alarm shall be automatically sounded throughout the crew accommodation and service spaces, control stations and machinery spaces of category A. PSCO observed audible and visual alarm in machinery space not activating. SOLAS 74 (1981) II-2/13.1.4, Restricted, Code 60
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 October 2022
Resolved 31 October 2022
Resolution: Received LR class report, SAT.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 27 October 2022 Resolved
All ships of 500 gross tonnage and upwards constructed on or after 01 September 1984 shall be fitted with indicator showing the rudder angle. All indicators shall be visible from the conning position. PSCO observed Port and STBD bridge wing rudder indicators 5 degrees out of parameters. SOLAS 74 (1981) V/12(m), Prior to Movement, Code 60
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 October 2022
Resolved 31 October 2022
Resolution: Received LR class report, SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Sickbay
Issued 19 February 2019 Resolved
09111-SICKBAY-HOSPITAL ACCOMODATION SHALL NOT BE USED FOR OTHER THAN MEDICAL PURPOSES. VESSEL CURRENTLY HAS 15 CREWMEMBERS ON BOARD AND MADE A VOYAGE OF OVER 3 DAYS. 15TH CREWMEMBER IS NOT NORMALLY ATTACHED AS VESSEL CREW, AND HAS BEEN ONBOARD SINCE SEPTEMBER 2018. CREW MEMBER IS CURRENTLY LIVING IN THE HOSPITAL SPACE FOR OTHER THEN MEDICAL PURPOSES.ILO-147/
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2019
Resolved 12 March 2019
Resolution: Cleared 01 deficiencies from Sector Housotn-Galveston Activity #6627875 with proper documentation from Flag State.
Operations/Management › Pollution › Control of Garbage
Issued 5 August 2008 Resolved
2120 - Garbage - The crew is not familiar with essential shipboard procedures relating to garbage. Trash is not being segregated. Mixed trash was found in recepticals labeled for segregation. Food waste was found to be mixed with all categories of trash, including plastic. 70c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 August 2008
Resolved 17 September 2008
Resolution: Coast Guard boarding team inspected the shipboard procedures and garbage management plan. All was found satisfactory.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 15 October 2004 Resolved
Remove crewmembers using Hospital Space as private berthing in accordance with ILO 147.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 October 2004
Resolution: HOSPITAL SPACE WAS CLEARED.
Navigation › Piloting/Steering › Binnacle
Issued 15 October 2004 Resolved
Provide required lumination for steering compass mounted in binnacle.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 15 October 2004
Resolution: Burned out bulb replaced and compass illuminated.

Ownership record