← All vessels
NEW FORTUNE
Freight Ship · Bulk Carrier class · Built 1990s · USCG Northeast District (CGD-NE) · Other hulls named NEW FORTUNE
NEW FORTUNE is a 1994 freight ship. The Coast Guard has recorded 30 inspections since 1995, most recently in September 2010, along with 28 deficiencies and 6 operational controls.
Records from 1995 to 2010. Most recent: inspection, 21 September 2010.
- Built
- 1994
- Last inspected
- 21 September 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 28 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9082946 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7OH3
415109
Flag
MARSHALL ISLANDS
—
Maury page id
psix-415109
Inspections, by type
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it26136 - Regulatory (Subpart C or D), Gross Ton
26136 - Convention (Subpart B), Gross Ton
14335 - Regulatory (Subpart C or D), Net Ton
14335 - Convention (Subpart B), Net Ton
52502 - Displacement, Ton
44820 - Dead Weight, Ton
26136 - Convention (Subpart B), Gross Ton
14335 - Regulatory (Subpart C or D), Net Ton
14335 - Convention (Subpart B), Net Ton
52502 - Displacement, Ton
44820 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 30
21 September 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3851081
14 September 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3850018
16 February 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam · ISM Exam · MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3680366
16 February 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3680814
16 February 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3681633
10 November 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3360664
31 May 2007
ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2947249
16 October 2006
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2801431
15 August 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2748412
13 April 2006
PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · Deficiency Check · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2620435
24 October 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2520718
8 June 2005
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2383556
26 May 2005
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2368595
20 May 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2363273
15 October 2004
PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2221561
11 October 2004
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2218238
4 December 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1963183
7 November 2002
Deficiency Check · Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1702469
10 October 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1687686
19 September 2002
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1677663
14 September 2002
Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1671264
16 March 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 289227
6 August 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 431697
23 January 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 424727
11 August 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 418793
5 December 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 410574
19 November 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 410165
6 November 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 397003
23 August 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 394496
23 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 382179
Deficiency record · 28
Construction/Loadline › Structures › Air Pipe
Issued 16 February 2010
Resolved
1200; Fore Peak air vent pipe in Bos'n store has a pin hole in it which is allowing water to leak into the space.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 16 February 2010
Resolved
2199; Located above the incinerator waste oil tank there is a homemade incinerator, which is not approved under MARPOL Annex VI.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 16 February 2010
Resolved
0750; Throughout the house, Engine Room there are fire doors which do not close properly or will not stay closed. All doors must be adjusted and corrected to the satisfaction of Class and the Administration.
Lifesaving › Lifeboat › Lifeline (becketed)
Issued 16 February 2010
Resolved
0600; Port / Starboard L/B Becket lines disconnected, Port L/B has a fuel and transmission leak. Launching instructions are not as per ships SOLAS Training Manual and Immersion Suits are too large for some crewmembers all items must be addressed by Class and the Administration.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 16 February 2010
Resolved
1400; The following were found in the engineering spaces and must be addressed by Class and Administration. Emergency Gen. fuel leakage, expired batteries in space, M/Engine air cooler discharge line 2cm crack, F/W cooler modification for shore supply, Sewage line leaking, M/E lube oil settling tank crack at bracket and hydraulics line forward Bos'n store for mooring and hatches leakage.
e
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 16 February 2010
Resolved
2510; It appears the Chief Engineer has not ensured pollution prevention requirements as defined in Major Conventions (SOLAS & MARPOL) and in the Company's Safety Management system. Identify and address to the satisfaction of Class / Flag the proper implementation of the Company's Environmental Protection Policy.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 February 2010
Resolved
1720; Proper operation of the Oily Water Separator is suspect. Oily Water discharge piping was removed and it appears it has not been used in a long period of time. Entries in the Oil Record Book are not consistent with the visual evidence of non-use from the discharge piping. Address the testing and proper operation to the satisfaction of Class, Flag and USCG.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 16 February 2010
Resolved
2199; Chief Engineer and 2nd Engineer appear to be unfamiliar with the use of the incinerator with regards to disposal of sludge. The incinerator does not appear to be working according to manufacturer's specifications. A portable burn barrel was found in the engine room; Address to the satisfaction of Class, Flag and USCG, MARPOL Annex VI.
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 16 February 2010
Resolved
2510; The COTP S/F questions the adequacy of the implementation of the vs. SMS specifically ISM Code Part A sections 2, 7, 9, 10 and 11 due to the number and critical nature of the deficiencies found. Evidence exist indicating that the vs. was bypassing the OWS and illegally pumping oil and oil residues directly overboard. The COTP recommends that a SM audit be performed by the RO prior to depart
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 February 2010
Resolved
1730; The vessels oil filtering equipment is not working as designed. The operation of the OWS cannot ensure that the processed effluent is less than 15ppm. The attending Classification Society Representative and Flag Representative must ensure proper operation prior to departure.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 16 February 2010
Resolved
1721; Due to the failure of both the oil filtering equipment and incinerator (Def listed pg 7 of from B DTD 16FEB10) the vessel's capability to retain oil residues and water oil mixtures are in question. The amount of oily waste oily wasted generated and capacity must be determined by Class and Flag Representatives to ensure the vessels has enough capacity of the next voyage.
Documentation › Logs/Records › Oil Record Book
Issued 16 February 2010
Resolved
1710; Sounding Notes found in the Engine Control Room do not match entries found in the Oil [name withheld] indicating that the machinery space operations are not being documented. The Master and Chief Engineer must record all machinery space oil transfer 4 operations as required by applicable regulations in the Oil Record Book.
Engineering › Bilge Water Management System › Pump
Issued 13 April 2006
Resolved
The safety guard for the bilge pump belt is missing. Replace the guard to the satisfaction of the attending classification society.
Electrical › Electric Generation Source (emergency) › Generator
Issued 13 April 2006
Resolved
The cut-off valve was not operating as designed. Vessel must repair the cut-off valve to the satisfaction of the attending classification society.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 24 October 2005
Resolved
The ship's Ballast Water Management Plan is not ship specific as required by reference 33 CFR 151.2035(a)(7)
Documentation › Logs/Records › Garbage Recordkeeping
Issued 24 October 2005
Resolved
The ship's Garbage Management Plan is not ship specific. Items authorized to be burned in the incinerator have not been identified. Disposal of ash and the location of waste receptacles has not been addressed.
Personnel › Training › Familiarization Training
Issued 24 October 2005
Resolved
According to the C/O he has held training regarding the separation, control and disposal of garbage numerous times. However, during our inspection we found mixed garbage in various parts of the vessel.
Lifesaving › Launching Appliances › Davit
Issued 24 October 2005
Resolved
Due to normal wear and tear all four of the davit arm limit switches have been renewed by the electrician. However he has relocated the switches approximately six to eight inches from where they were originally located. This location may be overstressing the cable. Class must inspect this to ascertain if damage will be or has been caused to the cable.
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 24 October 2005
Resolved
The crew was directed by the ship superintendent to install a main engine lube oil cylinder tank between the fresh water and main engine lube oil storage tank located on the starboard side of the engine room. Class has not been notified of this by the company. Class inspected this and required the company to restore the space to its original condition by April 2006.
Engineering › Shafting/Propeller Arrangements
Issued 4 December 2003
Resolved
Vessel Head Tank oil for shaft seal appears to be contaminated with water as evident by milky white appearence of oil in site glass. (SOLAS 74 I/11).
Pollution Prevention/Response › Prevention Equipment
Issued 14 September 2002
Resolved
Ship does not have a MARPOL copy of english instructions for OWS. Company to provide english copy to ship that details testing and maintance of OWS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Pollution Prevention/Response › Prevention Equipment
Issued 14 September 2002
Resolved
Does not have USCG approval placard from manufacture. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Personnel › Certificates/Documents/Licenses
Issued 14 September 2002
Resolved
Flag State STCW Endorsement for 2nd officer, 3rd officer, and 3rd engineer were tempory issue for 3 months and were found expired on 16SEP02. Full term endorsement shall be provided @ next port. LEGACY COMPONENT DESC: STCW Endorsement
Documentation › Safety Management System
Issued 14 September 2002
Resolved
Vessel Master did not have copy of external audit for issuance of full term SMC. Company shall provide copy for master to retain on board. LEGACY COMPONENT DESC: Reports and Analysis Procedures
Fire Fighting
Issued 19 November 1997
Resolved
Forward Fire Hose found unserviceable during test. Hose was replaced during the exam as per 74 SOLAS II-2/19.
Documentation
Issued 19 November 1997
Resolved
During Steering test it was found that the vessel crew was not familiar with pre-arrival test criteria as per 33 CFR 164.25 although it was logged in the ship's official logbook. Discussed criteria with vessel master and officers, item corrected during exam.
Navigation
Issued 19 November 1997
Resolved
Steering gear flat's deck covered with hydraulic fluid (slip hazard) and piping was stowed in space limiting local control areas working access. Clean deck and move piping stowed as per 74 SOLAS II-1/29.13.2 No later than 19DEC97.
Documentation
Issued 23 August 1996
Resolved
VESSEL' SOPEP DID NOT LIST NATIONAL OR LOCAL CONTACT POINTS FOR POLLUTION RESPONSE AS REQUIRED BY MARPOL ANNEX I CHAP. IV REG. 26 (2)(d). VESSEL TO PROVIDE PRIOR TO BUNKERING OPS. OR 23 OCT. 96, WHICHEVER COMES FIRST.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.