SPIRIT OF LAKE MURRAY

SPIRIT OF LAKE MURRAY is a 1994 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2016, most recently in March 2026, along with 34 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 18 March 2026.

Built
1994
Last inspected
18 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

415208
Flag
UNITED STATES
Maury page id
psix-415208

Documentation record

Registered dimensions (L × B × D)72.6 ft × 20.0 ft × 5.4 ft
Registered tonnagegross 51 / net 34
ITC dimensions (L × B × D)72.6 ft × 20.0 ft × 5.4 ft
ITC tonnageNot recorded
BuilderMID CITY STEEL FABRICATING · LA CROSSE, WI, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLAKE MURRAY, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

10 inspections, each with its date, unit and type; 34 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

18 March 2026 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8326611
9 December 2024 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8045205
28 November 2023 Inclining Experiment
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7828600
4 April 2023 Initial Certification · Examination of Repairs · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7663294
8 October 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6830740
15 January 2019 Drydock Extension · COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6610388
1 August 2018 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6498948
18 July 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6570540
22 May 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6153294
20 April 2016 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5859107

Deficiency record · 34

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 March 2026 Resolved
Shutoff valves, installed so as to close against the fuel flow...shall be operable from outside the tank compartment. Remote cable missing from fuel shutoff valves. 46 CFR 182.20-40(b)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 7 April 2026
Resolution: Picture and video well received. ALL SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2026 Resolved
Flexible or portable cords such as SO, STO, and similar types cannot be used for permanently installed wiring. Temporaty wiring and power strips in multiple spaces. 46 CFR 183.10-20(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 7 April 2026
Resolution: Picture well received. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026 Resolved
Motors shall be mounted as high as practicable above the bilges. A/C Pump not mounted. 46 CFR 183.10-5(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 7 April 2026
Resolution: Picture well received. ALL SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2026 Resolved
Marine Inspector shall require that all observed unsafe practices and hazardous situations be corrected. Missing splash covers on electrical outlets in head. 46 CFR 176.25-50(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 7 April 2026
Resolution: Picture well received. ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 March 2026 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in charge, Marine Inspection. Engine Room portable fire extinguisher not mounted. 46 CFR 181.30-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 7 April 2026
Resolution: Picture well received. ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 March 2026 Resolved
Covered metal trash containers shall be provided in lounge areas. Combustible trash cans found on board. 46 CFR 177.30-7(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 16 April 2026
Resolution: Picture well received. ALL SAT
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 March 2026 Resolved
A cable may be spliced only under conditions outlined in 46 CFR Subchapter J 111.60-40. Unauthorized splices in new lighting in the spaces below deck. 46 CFR 111.60-40
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 17 April 2026
Resolution: Pictures well received. ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 December 2024 Resolved
Each floating water light must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Vsl's waterlight approved under 161.112, needs approval under 161.010 or 160.110. 46 CFR 180.70(d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2025
Resolved 16 January 2025
Resolution: New waterlight purchased and attached to ring buoy near helm station
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 December 2024 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Vsl's adult and youth lifejackets stowed together on top deck, missing quantity identification. 46 CFR 180.78(a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2025
Resolved 16 January 2025
Resolution: PFD's seperated and properly labeled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 December 2024 Resolved
Fire hose shall be 1.5 inches in diameter and 50 feet in length. Stbd side fire hose on top deck had pin hole leak. 46 CFR 181.15-10(c) (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2025
Resolved 16 January 2025
Resolution: Fire hose replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 December 2024 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from... electrical shock of personnel. Dead end wires found on port side of E/R in vicinity of entrance. 46 CFR 183.01-5(a) (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2025
Resolved 16 January 2025
Resolution: Dead end wires removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 April 2023 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Forward bilge pump failed to operate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2024
Resolved 8 January 2024
Resolution: Small hole was discovered in bilge piping for #1 void, repair was made and successfully operated.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 May 2019 Resolved
Repair steel in the following areas: F/W Space Main Deck, STBD Aft Near Sewage Tank, Port Laz Space near Ladder, STBD Side Laz Xfers BLHD, Exhaust Trunk (Vent) STBD E/R
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2021
Resolution: Superseded or corrected during a subsequent inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2019 Resolved
Repair Bilge Piping Identified in Diesel Tank Room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2021
Resolution: Superseded or corrected during a subsequent inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2019 Resolved
Provide Proof of ASME Approved Air Compressor.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 9 December 2021
Resolution: Superseded or corrected during a subsequent inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2019 Resolved
Remove Dead End Wiring Throughout Vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 9 December 2021
Resolution: Superseded or corrected during a subsequent inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2019 Resolved
Mount Battery Boxes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 9 December 2021
Resolution: Superseded or corrected during a subsequent inspection.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 May 2019 Resolved
Missing Passenger Radio Certificate and DSC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 9 December 2021
Resolution: Superseded or corrected during a subsequent inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2018 Resolved
Renew SOLAS tape and grab line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 14 August 2018
Resolution: Grab line and retro was placed on two life rings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 August 2018 Resolved
Show proper operation of engineroom bilge suction.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2018
Resolved 1 August 2018
Resolution: Vessel rep showed proper operation of the engineroom bilge suction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2018 Resolved
Provide strain relief for cable located at port and starboard engine control box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 28 August 2018
Resolution: Strain relief added to both MDE control boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2018 Resolved
Provide strain relief for shore tie cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 14 August 2018
Resolution: Strain relief was provided for shore tie cable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2018 Resolved
Provide proper mounting for electric cable, port side, in freshwater tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 14 August 2018
Resolution: Power cable was properly spliced in dehumidifier box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 August 2018 Resolved
Povide repairs to generator raw water cooling pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 14 August 2018
Resolution: Third party replaced impeller for seawater pump on generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2018 Resolved
Tighten packing glands for both shafts and/or renew packing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 14 August 2018
Resolution: Packing glands were tightened by third party.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 August 2018 Resolved
Provide professional cleaning for generator windings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 28 August 2018
Resolution: Third party company provided service to generator windings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 August 2018 Resolved
Show proper operation of engine driven bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2018
Resolved 2 August 2018
Resolution: Vessel owner showed proper operation of engine driven bilge pump.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2018 Resolved
Properly wire GPS cable for navigation bridge in junction box and stuffing tube.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 16 October 2018
Resolution: GPS cable was properly routed to the antenna.
Electrical › Electric Supply System (service) › Cable
Issued 22 May 2017 Resolved
Remove extension cords from E/R.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 5 June 2017
Resolution: All extension cords were removed from the vessel.
Electrical › Electric Generation Source (service) › Generator
Issued 22 May 2017 Resolved
Remove oil from vent and windings.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 5 June 2017
Resolution: Engine mechanic attended vessel and replaced rear main seal of prime mover.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 April 2016 Resolved
Provide copy of original COD.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 29 April 2016
Resolution: Vessel owner renewed COD.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 April 2016 Resolved
Provide replacement for expired medications.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 27 April 2016
Resolution: Epired medications were updated.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 20 April 2016 Resolved
Purchase and place in service three hose clamps for exhaust.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 27 April 2016
Resolution: New hose clamps were placed in service.
Engineering › Freshwater Generation System › Piping
Issued 20 April 2016 Resolved
Replace drain hoses for sink drain and A/C drain.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 27 April 2016
Resolution: Both hoses were replaced with wire-reindorced hose and double-clamped.