MAURY USCG vessel records Sign in
← All vessels

IRIS K

IRIS K is a 1980 freight ship. The Coast Guard has recorded 22 inspections since 1994, most recently in November 2007, along with 42 deficiencies and 1 operational control.

Records from 1994 to 2007. Most recent: inspection, 26 November 2007.

Built
1980
Last inspected
26 November 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8031108 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
415267
Flag
CYPRUS
—
Maury page id
psix-415267

Inspections, by type

…with no type recorded19
Years with a record 6 calendar years (1994–2007)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10225 - Convention (Subpart B), Gross Ton
5416 - Convention (Subpart B), Net Ton
12665 - Dead Weight, Ton
18770 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HOLLYWOOD 1303 Tank Barge · MISLE 43389 · 22 February 1995 · activity 462546

Inspection history · 22

26 November 2007 MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3101198
1 September 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 432124
24 August 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 419572
28 February 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 413262
14 December 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 442954
7 October 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 396129
16 March 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 47381
26 February 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 388231
16 December 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 386109
20 October 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 204771
20 October 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765660
13 October 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 383688
4 May 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 377946
1 March 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 699642
22 February 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 462546
11 February 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 375096
6 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 373367
6 December 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 829630
30 November 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411051
21 November 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 867276
13 November 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 372337
13 November 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1405619

Deficiency record · 42

Accommodation/Occupational Safety
Issued 1 September 1999 Resolved
MAKE PERMANENT REPAIRS TO FRESH H/W TANK THERMOSTAT WELL.
Condition: Unknown
Due 13 September 1999
Resolved 13 September 1999
Electrical
Issued 1 September 1999 Resolved
REPLACE/RENEW LIGHT COVER ON STBD SIDE LWR LVL OF E/R.
Condition: Unknown
Due 13 September 1999
Resolved 10 September 1999
Construction/Loadline
Issued 1 September 1999 Resolved
MAKE PERMANENT REPAIRS TO HOLED AREA OF HOUSE ON STBD SIDE, AFT, UNDER DOORTO O2 STORAGE ROOM.
Condition: Unknown
Due 13 September 1999
Resolved 10 September 1999
Construction/Loadline
Issued 1 September 1999 Resolved
MAKE PERMANENT REPAIRS TO HOLED AREA OF SUPERSTRUCTURE IN WAY OF STEVADORE'S HEAD ON FWD SIDE OF HOUSE AT MAIN DECK
Condition: Unknown
Due 13 September 1999
Resolved 10 September 1999
Lifesaving
Issued 1 September 1999 Resolved
CLASS TO ATTEST TO THE CONDITION OF PORT L/B PROP SHAFT AND "U" JOINTS.
Condition: Unknown
Due 6 September 1999
Resolved 10 September 1999
Construction/Loadline
Issued 1 September 1999 Resolved
MAKE PERMANENT REPAIRS TO WASTED DECK IN EMERGENCY F/P ROOM.
Condition: Unknown
Due 13 September 1999
Resolved 10 September 1999
Lifesaving
Issued 1 September 1999 Resolved
CREW TO CONDUCT SAT ABANDONSHIP DRILL WHEN L/B ISSUES HAVE BEEN SATISFACTORILLY ADDRESSED.
Condition: Unknown
Due 6 September 1999
Resolved 10 September 1999
Lifesaving
Issued 1 September 1999 Resolved
MAKE PERMANENT REPAIRS TO F/W PIPING ABOVE OWS AND STBD SIDE LWR LVL OF E/RAFT OF MDE.
Condition: Unknown
Due 13 September 1999
Resolved 13 September 1999
Lifesaving
Issued 1 September 1999 Resolved
CLASS TO ATTEST TO CONDITION OF PORT FWD DAVIT FALL BLOCK.
Condition: Unknown
Due 13 September 1999
Resolved 10 September 1999
Lifesaving
Issued 1 September 1999 Resolved
REPLACE ALL MOORING LINES EXCEPT THE 2 NEW ONES.
Condition: Unknown
Due 6 September 1999
Resolved 10 September 1999
Lifesaving
Issued 1 September 1999 Resolved
CLASS TO ATTEST TO CONDITION OF PORT DAVIT AND FALL BLOCK SHEEVES.
Condition: Unknown
Due 6 September 1999
Resolved 10 September 1999
Lifesaving
Issued 1 September 1999 Resolved
CLASS TO ATTEST TO CONDITION OF STBD L/B DAVIT BRAKE.
Condition: Unknown
Due 6 September 1999
Resolved 10 September 1999
Navigation
Issued 7 October 1996 Resolved
FOUND NO ENTRY IN SHIPS LOG FOR A TEST OF THE GENERAL ALARM. SOLAS III/19/6.3_x001C_
Condition: Unknown
Due 16 December 1996
Resolved 16 December 1996
Navigation
Issued 7 October 1996 Resolved
NO ENTRY MADE IN SHIPS LOG FOR PRE-ARRIVAL TESTS.
Condition: Unknown
Due 16 December 1996
Resolved 16 December 1996
Documentation
Issued 7 October 1996 Resolved
FOUR COMPLETED PAGES OF THE OIL RECORD BOOK WERE NOT SIGNED BY MASTER._x001C_
Condition: Unknown
Due 16 December 1996
Resolved 16 December 1996
Construction/Loadline
Issued 7 October 1996 Resolved
THE VESSEL'S DRAFT MARKINGS WERE NOT IN CONTRASTING COLORS AND WERE DIFFICULT TO READ. ICLL 66 ANNEX 1/25._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1996
Resolved 16 December 1996
Accommodation/Occupational Safety
Issued 7 October 1996 Resolved
MARINE SANITATION DEVICE WAS NOT PROPERLY LABELED. 33 CFR 159.55_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1996
Resolved 16 December 1996
Lifesaving
Issued 7 October 1996 Resolved
FOUND NO ENTRY IN SHIPS LOG FOR FIRE/ ABANDONSHIP DRILLS. SOLAS III/18-5
Condition: Unknown
Due 16 December 1996
Resolved 16 December 1996
Fire Fighting
Issued 16 December 1995 Resolved
PROVIDE KEYS FOR FIREMANS OUTFIT LOCKER OR REMOVE LOCK._x001C_ SOLAS 74 II 2/21_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1995
Resolved 21 December 1995
Engineering
Issued 16 December 1995 Resolved
PROVIDE FLANGE BOLTS WHERE MISSING ON THE PORT AND STARBOARD BUNKERING STATIONS._x001C_ MARPOL 73/78 I/16
Condition: Unknown
Due 17 December 1995
Resolved 21 December 1995
Accommodation/Occupational Safety
Issued 16 December 1995 Resolved
MAKE REPAIRS TO THE STARBOARD WEATHER TIGHT DOOR, OUTSIDE OF THE [name withheld], SO THAT IT CLOSES CORRECTLY. _x001C_ ICLL 66 REG. 22
Condition: Unknown
Due 17 December 1995
Resolved 21 December 1995
Engineering
Issued 16 December 1995 Resolved
REPLACE MISSING FLAME SCREENS ON FUEL OIL VENTS.
Condition: Unknown
Due 17 December 1995
Resolved 21 December 1995
Accommodation/Occupational Safety
Issued 16 December 1995 Resolved
REPLACE WASTED EMBARKATION LIGHT MOUNTING BRACKET. _x001C_ SOLAS 74 III/11 4
Condition: Unknown
Due 17 December 1995
Resolved 21 December 1995
Engineering
Issued 16 December 1995 Resolved
DEMONSTRATE PROPER OPERATION OF THE OILY WATER SEPARATOR._x001C_ MARPOL 73/78 I/16_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1995
Resolved 21 December 1995
Navigation
Issued 16 December 1995 Resolved
DEMONSTRATE OPERATION OF THE LOSS OF POWER ALARM FOR THE NO. 2 STEERING GEAR UNIT._x001C_ SOLAS 74 19/2_x001C_ _x001C_
Condition: Unknown
Due 17 December 1995
Resolved 21 December 1995
Electrical
Issued 16 December 1995 Resolved
DEMONSTRATE OPERATION OF EMERGENCY FIRE PUMP._x001C_ SOLAS 74 II-2/21
Condition: Unknown
Due 17 December 1995
Resolved 21 December 1995
Lifesaving
Issued 16 December 1995 Resolved
DEMONSTRATE OPERATION OF PORT AND STARBOARD LIFEBOAT ENGINES._x001C_ SOLAS 74 111/19_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1995
Resolved 21 December 1995
Electrical
Issued 16 December 1995 Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY GENERATOR UNDER ELECTRICAL LOAD._x001C_SOLAS 74 II-1/26_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1995
Resolved 21 December 1995
Electrical
Issued 16 December 1995 Resolved
REPLACE THE MISSING FUSES FOR THE HYDRAULIC PUMPS FOR #2 AND #3 HATCH COVERS._x001C_ _x001C_
Condition: Unknown
Due 17 December 1995
Resolved 21 December 1995
Lifesaving
Issued 16 December 1995 Resolved
REPAIR JACKET WATER LEAK ON EMERGENCY GENERATOR._x001C_ SOLAS 74 II-1/26
Condition: Unknown
Due 26 February 1996
Resolved 26 February 1996
Lifesaving
Issued 13 October 1995 Resolved
A VIO OF SOLAS CHAPTER III REGULATION 19 IN THAT THE VSL'S LIFERAFTS HAD TWO HYDROSTATIC RELEASES WHICH WERE BEYOND THEIR SERVICE DATE.
Condition: Unknown
Due 13 October 1995
Resolved 18 October 1995
Lifesaving
Issued 6 December 1994 Resolved
VESSELS MAIN ENGINE HAD EXCISIVE OIL ON IT.
Condition: Unknown
Due 11 February 1995
Resolved 11 February 1995
Electrical
Issued 6 December 1994 Resolved
VESSEL MISSING PROTECTIVE LIGHT COVERS IN ENGINEERING SPACES.
Condition: Unknown
Due 11 February 1995
Resolved 11 February 1995
Lifesaving
Issued 6 December 1994 Resolved
VESSEL HAD EXCISIVE OIL ON DECK IN STEERING SPACE.
Condition: Unknown
Due 11 February 1995
Resolved 11 February 1995
Fire Fighting
Issued 13 November 1994 Resolved
CONDUCT HYDROSTATIC TEST OF ALL FIRE HOSES AND RENEW ALL LEAKING AND DEFECTIVE HOSES NOTED.
Condition: Unknown
Due 13 November 1994
Resolved 14 November 1994
Documentation
Issued 13 November 1994 Resolved
PROVIDE DOCUMENTATION THAT FLAG STATE RECOGNIZES OFFICER LICENSES ISSUED BYFOREIGN FLAG (POLAND) TO SERVE ONBOARD ST. VINCENT FLAGGED VESSELS IN ACCORDANCE WITH STCW CONVENTION.
Condition: Unknown
Due 13 November 1994
Resolved 13 November 1994
Navigation
Issued 13 November 1994 Resolved
PROVE OPERATION OF STEERING GEAR ALARMS
Condition: Unknown
Due 13 November 1994
Resolved 14 November 1994
Fire Fighting
Issued 13 November 1994 Resolved
RENEW DETERIORATED AND HOLED FIREMAIN PIPING ON MAIN DECK IN WAY OF NO.1. AND NO.4 CARGO HOLD PORT SIDE.
Condition: Unknown
Due 13 November 1994
Resolved 14 November 1994
Engineering
Issued 13 November 1994 Resolved
RENEW HOLED FLAME SCREENS TO ALL FUEL OIL TANK VENTS. ITEM SHALL BE CORRECTED PRIOR TO NEXT VOYAGE BACK TO ANY U.S. PORT.
Condition: Unknown
Due 13 November 1994
Resolved 13 November 1994
Construction/Loadline
Issued 13 November 1994 Resolved
REPAIR AND PROVE OPERATION OF ALL WATERTIGHT AND WEATHERTIGHT CLOSURES THROUGHOUT THE VESSEL. NOTED NUMEROUS CLOSURES THAT ARE EITHER FROZEN, HOLED AND OR MISSING CLOSING DEVICES. THIS ITEM SHALL BE CORRECTED NO LATERTHAN NEXT VOYAGE BACK TO ANY U.S. PORT.
Condition: Unknown
Due 13 November 1994
Resolved 13 November 1994
Fire Fighting
Issued 13 November 1994 Resolved
RENEW OR REPAIR DEFECTIVE MAIN DECK FIREMAIN ISOLATION VALVE LOCATED JUST AFT OF PAINT LOCKER ENTRANCE MIDSHIPS.
Condition: Unknown
Due 13 November 1994
Resolved 14 November 1994
Fire Fighting
Issued 13 November 1994 Resolved
PROVE OPERATION OF EMERGENCY FIRE PUMP.
Condition: Unknown
Due 13 November 1994
Resolved 14 November 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.