Records from 1994 to 2005. Most recent: inspection, 27 April 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
27 April 2005
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2344463
10 September 2003
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1901427
17 October 2002
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1691151
23 May 2002
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1620001
15 October 2001
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1429636
23 October 2000
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1391397
12 May 2000
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1456855
20 October 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1125967
6 October 1999
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1436276
3 November 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 803827
26 October 1998
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1393000
28 April 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1416694
3 December 1997
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 775771
22 October 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1364412
19 August 1997
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 784420
31 July 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 781930
15 May 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1105307
8 October 1996
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 838737
8 October 1996
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1149519
3 November 1995
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 881343
10 October 1995
Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1188472
4 January 1995
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1165671
2 November 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 862593
17 October 1994
Inclining Experiment · COI Inspection · Hull Examination · MARPOL Annex V Examination · Plan Review "T" Boat
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 865443
Construction/Loadline
Issued 23 October 2000
Resolved
Required hIGH level alarm indicating light missing for each compartment with thru hull fittings.
Condition: Unknown
Due 24 October 2000
Resolved 30 October 2000
Engineering
Issued 23 October 2000
Resolved
MDE F/O return pipe is leaking at the tank.
Condition: Unknown
Due 24 November 2000
Resolved 30 October 2000
Engineering
Issued 12 May 2000
Resolved
INSPECT SHAFT KEYWAY FOR CRACKS.
Condition: Unknown
Due 19 May 2000
Resolved 27 June 2000
Engineering
Issued 12 May 2000
Resolved
PROVIDE FLAME SHIELD ON RACOR FUEL FILTER.
Condition: Unknown
Due 19 May 2000
Resolved 23 May 2002
Construction/Loadline
Issued 12 May 2000
Resolved
REPAIR PORT AND STBD TRANSOM CORNERS.
Condition: Unknown
Due 19 May 2000
Resolved 27 June 2000
Engineering
Issued 12 May 2000
Resolved
REPAIR PROP.
Condition: Unknown
Due 19 May 2000
Resolved 27 June 2000
Construction/Loadline
Issued 12 May 2000
Resolved
CLEAN TRASH FROM BILGES.
Condition: Unknown
Due 19 May 2000
Resolved 27 June 2000
Engineering
Issued 6 October 1999
Resolved
Replace all non metalic piping on fuel system with authorized material.
Condition: Unknown
Due 20 October 1999
Resolved 21 October 1999
Navigation
Issued 6 October 1999
Resolved
Replace hydraulic line with approved SAE J-1475 flexible nonmetalic hose.
Condition: Unknown
Due 20 October 1999
Resolved 21 October 1999
Construction/Loadline
Issued 6 October 1999
Resolved
Prove proper operation of forward bilge pump and high water alarm.
Condition: Unknown
Due 20 October 1999
Resolved 21 October 1999
Lifesaving
Issued 6 October 1999
Resolved
Remount life ring and floatlight to be readily accessible and provide type II retroreflective tape for same.
Condition: Unknown
Due 20 October 1999
Resolved 21 October 1999
Fire Fighting
Issued 6 October 1999
Resolved
Remount portable fire extinguisher from compartment aft of engine room to forward, outside of engine compartment.
Condition: Unknown
Due 20 October 1999
Resolved 21 October 1999
Lifesaving
Issued 26 October 1998
Resolved
Replace grab line and life line on ring buoy with dark u/v resistant line and install missing retro tape.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Construction/Loadline
Issued 26 October 1998
Resolved
Install high level bilge alarms.
Condition: Unknown
Due 26 October 1998
Resolved 26 October 1998
Documentation
Issued 26 October 1998
Resolved
Provide proof of current vessel certificate of documentation.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Navigation
Issued 26 October 1998
Resolved
Prove proper operation of emergency steering and anchor light.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Fire Fighting
Issued 26 October 1998
Resolved
Install Coast Guard approved fixed fire fighting system.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Construction/Loadline
Issued 26 October 1998
Resolved
V and weld crack on starboard side of passenger boarding platform bracket.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Engineering
Issued 26 October 1998
Resolved
Replace missing bolt on shaft coupling.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Fire Fighting
Issued 26 October 1998
Resolved
Provide proof of servicing and suitability of mounting arrangement for fixed fire fighting system.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Engineering
Issued 26 October 1998
Resolved
Replace existing fuel vent with proper vent and flame screen IAW 46CFR182.450
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Engineering
Issued 22 October 1997
Resolved
Replace the diesel engine crank case vent hose.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Construction/Loadline
Issued 22 October 1997
Resolved
Provide a suitable hand portable bilge pump with adequate hose length.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Lifesaving
Issued 31 July 1997
Resolved
REPLACE OR RETAPE 7 ADULT PFDS. VSL LIMITED TO 42 PASSENGERS UNTLI CLEARED.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Construction/Loadline
Issued 31 July 1997
Resolved
PROVIDE HAND PUMP FOR VSL.
Condition: Unknown
Due 31 July 1997
Resolved 4 August 1997
Lifesaving
Issued 31 July 1997
Resolved
SEPERATE ADULT PFD'S FROM CHILD PFD'S.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Engineering
Issued 31 July 1997
Resolved
STENCIL HATCH TO EMERGENCY F/O SHUTOFF "KEEP UNLOCKED WHILE UNDERWAY".
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Lifesaving
Issued 31 July 1997
Resolved
POST EMERGENCY PROCEDURES.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Unknown
Issued 15 May 1997
Resolved
PROVIDE AND POST VHF BROADCAST PLACARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 May 1997
Resolved 15 May 1997
Lifesaving
Issued 15 May 1997
Resolved
APPLY REFLECTIVE TAPE TO LIFERING.
Condition: Unknown
Due 19 May 1997
Resolved 15 May 1997
Fire Fighting
Issued 10 October 1995
Resolved
Provide evidence of annual servicing IAW 46 CFR part 176.25-25 for fixed CO2 system on board.
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Unknown
Issued 17 October 1994
Resolved
POST APPROPRIATE POLLUTION PLACARDS PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Documentation
Issued 17 October 1994
Resolved
PROVIDE A VALID MARINE DOCUMENT PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Construction/Loadline
Issued 17 October 1994
Resolved
PUT PROPER MARKINGS ON VESSELS HULL IE. NAME, HAILING PORT PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Documentation
Issued 17 October 1994
Resolved
PROVIDE DRUG TESTING INFORMATION IAW 46 CFR PART 16 PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Lifesaving
Issued 17 October 1994
Resolved
PROPERLY LABEL RING BUOY PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Lifesaving
Issued 17 October 1994
Resolved
PROVIDE SUITABLE RESCUE LADDER/PLATFORM PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Construction/Loadline
Issued 17 October 1994
Resolved
HAVE VESSELS OFFICIAL NUMBER PERMANENTLY MARKED IN HULL PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Fire Fighting
Issued 17 October 1994
Resolved
PROPERLY LABEL FIRE DAMPER CLOSURES PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Lifesaving
Issued 17 October 1994
Resolved
PROPERLY LABEL ALL ADULT AND CHILD P.F.D.'S PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Fire Fighting
Issued 17 October 1994
Resolved
PROVIDE (1) B-I AND (1) B-II FIRE EXTINGUISHER PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Documentation
Issued 17 October 1994
Resolved
PROVIDE APPROPRIATE MASTERS LICENSE PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Lifesaving
Issued 17 October 1994
Resolved
POST EMERGENCY CHECK-OFF LIST PRIOR TO OPERATING.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994