MAURY USCG vessel records Sign in
← All vessels

HOPE

HOPE is a 1980 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 2000, most recently in May 2026, along with 52 deficiencies, 1 operational control and 1 casualty investigation in 2018.

Records from 2000 to 2026. Most recent: inspection, 19 May 2026.

Built
1980
Last inspected
19 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG4356
Flag
UNITED STATES
368319110
Maury page id
psix-4155

Inspections, by type

…with no type recorded1
Years with a record 24 calendar years (2000–2026)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 4.0 ft
Registered tonnagegross 12 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIFLITE INC · BELLINGHAM, WA, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBAILEYS HARBOR, WI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9101MMSI 368319110 · active · compulsorily equipped · granted 17 April 2026, expires 17 April 2036
WDN8596MMSI 368319110 · cancelled · compulsorily equipped · granted 9 June 2023, cancelled 13 April 2026
WDG4356MMSI 367535710 · expired · compulsorily equipped · granted 19 June 2012, cancelled 20 August 2022
WDA7573MMSI 366844790 · expired · compulsorily equipped · granted 29 March 2002, cancelled 2 June 2012 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 36

19 May 2026 Vessel Attendance · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8376763
18 August 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8212919
13 March 2025 Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8095800
24 June 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7942452
10 May 2023 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7692450
17 May 2022 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7453096
21 July 2021 Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7263891
7 July 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7247930
12 April 2021 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7173700
26 May 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6960962
6 April 2020 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6936123
17 June 2019 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6717109
6 June 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6705186
3 September 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6531796
3 September 2018 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6534297
30 May 2018 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6436313
8 May 2017 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6141400
13 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6057301
16 May 2016 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5892669
3 June 2014 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4880024
28 June 2012 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4359836
10 December 2010 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3908226
24 March 2010 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3702063
3 July 2009 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3526544
5 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3227867
25 April 2008 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3189617
26 July 2007 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3015151
18 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2932338
12 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2647340
17 June 2005 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2393442
6 May 2005 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2347740
10 May 2004 Annual Inspection · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2067380
25 April 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1764464
17 May 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1608812
7 May 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1395739
29 June 2000 Hull Examination · COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1420334

Deficiency record · 52

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2026 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel had no fire buckets aboard. Provide vessel with fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 June 2026
Resolution: Owner put new labeled buckets on the vessel with appropriate lengths of lanyards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2026 Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 05 life jackets lacked full retro-reflective material. Replace retro-reflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 June 2026
Resolution: New PFDs were received, labeled, and placed on board. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 May 2026 Resolved
A visual and audible bilge high water alarm must be provided at the operating station to indicated a high water level designated space. Bilge pump activation sensors are unsecured in the space. Secure bilge high water alarm sensors.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 June 2026
Resolution: High water alarm sensors were secured. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2024 Resolved
The vessel had significant steady dripping from shaft seal and rudder packing that increased while underway.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 June 2024
Resolved 25 June 2024
Resolution: Returned to this vessel to witness adjustments. Leak is secured.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 May 2023 Resolved
Observed several items first aid kit items were expired. Renew all expired items iaw 46 CFR 184.710 & 160.041-4(b).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 6 June 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 May 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 13 June 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 23 May 2023 Resolved
Alcohol testing strips expired. Renew iaw46 CFR Part 16.240
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 6 June 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 23 May 2023 Resolved
Chemical Testing program records unavailable. Completed Chemical testing program compliance audit as required by 46 CFR Part 16.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 13 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2023 Resolved
Observed Life Jackets reflected vessels previous name. Relabel all life jackets with vessels new name. As required by 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 6 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 23 May 2023 Resolved
Observed crew members were not wearing PFD's when mooring and unmooring vessels. Recommend new O/O procure and require crew to wear CG approved Type III or V pfd's 46 CFR 185.508
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 6 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2023 Resolved
Observed adult life jacket stowage, fwd port side not labeled. Label stowage as required by 46 CFR 185.130
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 6 June 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2023 Resolved
Observed fuel oil supply shut off valve not labeled. Label valve as required by 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 6 June 2023
04 - Emergency Systems › N/A - No Subsystem › Shipboard Marine Pollution emergency operations
Issued 23 May 2023 Resolved
Second hand bilge pump not onboard. Fit vessel with a secondary bilge pump as required by 46 CFR 182.520(b).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 6 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2023 Resolved
Engine RPM tach not working. Repair and demo proper operation as required by 46 CFR 182.410(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 19 September 2023
Resolution: Lead MI verified new RPM gauge.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 23 May 2023 Resolved
Depth sounder not operational. Repair and demo operation as required by 46 CFR 176.816
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 6 June 2023
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 May 2023 Resolved
PA system not operational. Obtain mic and demo operation as required by 46 CFR 184.602.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 6 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 May 2022 Resolved
Engine Fire Boy extinguishing alarm sensor, green changed light not illuminated. During upcoming serving, service rep to investigate and correct. In addition 3rd party service rep to verify over ride switch. System last serviced June 2021. When completed O/O to provide service report in accordance with 46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2022
Resolved 20 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 20 May 2022 Resolved
Hand rail located port side near operators station fractured. Re-weld fractured hand rail as required by 46 CFR 177.900
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2022
Resolved 20 June 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 May 2022 Resolved
Great Lakes Light List and Coast Pilot publications outdated. Obtain and place new updated light list and Coast pilot onboard the vessel as required by 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2022
Resolved 20 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2022 Resolved
Life jacket stowage labels worn. Relabel life jacket stowage compartments as required by 46 CFR 185.604.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2022
Resolved 20 June 2022
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 21 July 2021 Resolved
Employee Assistance Program education program information was not displayed. Display EAP information as required by 46 CFR 16.401
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 6 August 2021
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 21 July 2021 Resolved
Employee Assistance Program HotLine Number was not displayed. Display HotLine Number as required by 46 CFR 16.401
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 6 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 July 2021 Resolved
Placards for donning PFDs are required to be displayed. Placard was not present during inspection, required O/O to produce a placard on post onboard. 46 CFR 185.516
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 21 July 2021
Resolution: PFD Donning Display posted
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 July 2021 Resolved
Vessels must carry first aid kits approved under approval series 160.041. Aspirin, ammonia inhalants, and iodine swabs were akk expired; replace items to complete first aid kit. 46 CFR 184.710 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 21 July 2021
Resolution: Observed and verified new Aspirin, Ammonia, & iodine swabs onboard
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 July 2021 Resolved
A vessel of at least 26' must have a visual and audible alarm for high water in bilge. Visual indicator was inoperable at time of inspection; require O/O to repair or replace indicator. 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 21 July 2021
Resolution: Verified high bilge water visual and audible alarms
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 July 2021 Resolved
All fittings on firehoses shall be of copper, brass or other suitable corrosive resistant metal. Plastic hose nozzle was being used on firefighting hose. O/O replaced with aluminum nozzle during inspection. OLD T 46 CFR 181.15-10(f)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 21 July 2021
Resolution: Verified brass nozzle onboard
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2020 Resolved
Vessel is overdue for its five year drydock and internal structural examination. Vessel must undergo a drydock examination and an internal examination at least once every five years. Complete drydock examination and internal structural examination. (46 CFR 176.600)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2020
Resolution: Vessel completed sat drydock and ise inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2019 Resolved
Life ring buoy was split in multiple locations. Replace life ring buoy. Ring buoy needs to be at least 24 inches in diameter and be approved in accordance with 46 CFR 160.050.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 June 2019 Resolved
Life-ring buoy waterlight battery was last replaced in 2014. Waterlight battery needs to be replaced annually or by their marked expriation date. Replace battery with a suggested battery specified on the water-light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 June 2019 Resolved
Bilges have a considerable amount of oil accumulation on surfaces posing a fire hazard. Surfaces/bilges must be sufficiently cleaned to eliminate pollution & fire hazards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 September 2018 Resolved
Vessel fowled it's prop while underway with passengers. Vessel in prohibited from carrying passengers until an in inspection is satisfactorily completed by a CG MI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2018
Resolution: Line was removed from the prop and the associated structure was inspected by a CG [name withheld] test showed no vibration or lingering effects of the incident.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 30 May 2018 Resolved
Bilges have a considerable amount of oil accumulation on surfaces posing a fire hazard. Surfaces/bilges must be sufficiently cleaned to eliminate pollution & fire hazards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 12 June 2018
Resolution: bilges cleaned.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 May 2018 Resolved
First Aid kit on board has expired items. Items are to be replaced in kind or a new CG Approved first aid kit is to be provided on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 13 June 2018
Resolution: first aid kit updated
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 30 May 2018 Resolved
Vessel does not have approved alcohol testing devices on board to meet Serious Marine Incident testing requirements. Provide a sufficient number of approved devices to be maintained on board at all times.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 13 June 2018
Resolution: approved devices were placed on board.
Navigation › Piloting/Steering › Marine Charts
Issued 30 May 2018 Resolved
Vessel does not have a new or properly corrected and up to date chart for vessel's operating area. New or corrected charts for vessel's operational areas are to be provided and maintained on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 13 June 2018
Resolution: chart updated and on board.
Electrical › Electrical Distribution System (service) › Cable
Issued 30 May 2018 Resolved
Electrical cables were found not properly supported every 24 inches and in some cases were found laying in the bilges. Ensure all cables are properly supported and raised out of the bilges. Supports should be metal and secured to a vessel structure.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 13 June 2018
Resolution: Cables/wires found properly supported.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 30 May 2018 Resolved
Fire, Man overboard & abandon ship drills are not being logged. Provide log book and properly document drills.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 13 June 2018
Resolution: Log book available and drill requirements stressed to master on importance of logging them.
Documentation › Certificates/Documents › FCC SSL
Issued 9 May 2017 Resolved
Obtain an annual Great Lakes FCC Radio Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 17 May 2017
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 May 2017 Resolved
Relabeled all lifejacket stowage compartments, to reflect the proper number of life jackets stowed within each compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 17 May 2017
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 9 May 2017 Resolved
Update companies Chemical Testing Program, to reflect all employees are covered in the companies’ consortium.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 17 May 2017
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 1 June 2016 Resolved
Life Jacket donning placards were note posted. Post the life jacket donning placard per 46 CFR 185.516
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 8 June 2016
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 1 June 2016 Resolved
Several Adult Life Jacket stowage compartments were not labeled. Where missing, with two inch high letters label the adult life jacket stowage compartments per 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 8 June 2016
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 3 June 2014 Resolved
The FE-241 Clean Agent bottle's guage is not working, repair or replace the bottle & gauge. System will need a service inspection tag from an authorized NFPA company.
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 1 July 2014
Resolution: Fixed fire extiquishing system was replaced, in stalled by Van''s Fire Safety.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 June 2014 Resolved
Vessel is required 1 Ringbuoy with light & line attached.
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 1 July 2014
Resolution: Light & Line were correctly attached to the ring buoy.
Engineering › Bilge Water Management System › Not Operational
Issued 3 June 2014 Resolved
Excessive oil was noticied in the bilges (3 total). Vessel to remove water & oil.
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 1 July 2014
Resolution: Bilges were cleaned.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 April 2008 Resolved
Cover battery to sufficiently protect from water splash and passenger access.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 5 June 2008
Resolution: Battery had terminal covers installed properly.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 26 July 2007 Resolved
Assess condition of shaft, bearings, and packing and replace as necessary, demonstrating proper operation thereafter to the satisfaction of an attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2007
Resolution: Installed new shaft bearings, new packing, and rebuilt stuffing box. Demonstrated proper fwd and aft ops to MI.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 10 May 2004 Resolved
Prove proper operation of fixed fire fighting system engine shutdown. LEGACY COMPONENT DESC: Control Valve
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2004
Resolution: Sighted this date. [name withheld]
Electrical › Electric Supply System (service)
Issued 10 May 2004 Resolved
Install covers for battery. LEGACY COMPONENT DESC: Cable
Due 10 June 2004
Resolved 17 May 2004
Resolution: Sighted this date [name withheld]
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 May 2004 Resolved
Provide double hose clamps for all raw water lines.
Due 10 June 2004
Resolved 17 May 2004
Resolution: Sighted this date [name withheld]
Construction/Loadline
Issued 7 May 2001 Resolved
Provide proposal and make permanent repairs of fiberglass, in way of hatch cover & decking at operator's station, to the satisfaction of the attendingmarine inspector and the cognizant OCMI.
Condition: Unknown
Due 17 June 2001
Resolved 23 January 2004
Documentation
Issued 7 May 2001 Resolved
Ensure original Certificate of Inspection and original Stability Letter areplaced on board vessel, prior to the carraige of passengers and to the sat-isfaction of the attending marine inspector and cognizant OCMI.
Condition: Unknown
Due 17 June 2001
Resolved 25 May 2001

Casualty record · 1

3 September 2018Routine · role: Involved in a Marine Casualty · activity 6534297
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

WATER TAXI (2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.